• 제목/요약/키워드: Breath holding

검색결과 37건 처리시간 0.024초

외래환자에서 금연 성공의 결정요인 (Predictors of smoking Cessation in Outpatients)

  • 강윤식;장정순;황영실;홍대용;김장락
    • Journal of Preventive Medicine and Public Health
    • /
    • 제36권3호
    • /
    • pp.248-254
    • /
    • 2003
  • Objective : This study was conducted in order to investigate predictors of smoking cessation in outpatients. Method : Subjects were 40f adult smoking patients who saw their doctors in the outpatient setting at a university hospital, regardless of their willingness of otherwise in smoking cessation. Physicians delivered a brief, stop smoking prompt to all patients who smoked one or more cigarettes a day. Then they referred to on-site counselors who provided a brief, nurse assisted intervention with a survey to a randomly assigned intervention group (200 smoking patients), whom the counselors telephoned later to prevent relapse or promote the motivation to quit, or gave only a survey to a control group (201 smoking patients). After at least 5 months, self-reported current smoking cessation was confirmed later using cut-off values of 7 ppm or less in expired alveolar air after breath holding portable CO analyzer. Results : After 5 months, subjects in the intervention group were 1.56 times (95% C.I. 0.89-2.73) more likely to quit smoking than those in the non-intervention group (14.0% vs. 9.0%). Willingness to quit smoking in a month, scheduled admission in a month, self efficacy score and FTND (Fagerstrom Test for Nicotine Dependence) score were all significantly related with smoking cessation. In stepwise multiple logistic regression, previous attempts to quit smoking were significant instead of self efficacy score. In the intervention group who had willingness to quit smoking in a month (132 smoking patients), FTND score, whether quit date was today, and whether quit promise paper was submitting were all significantly related with smoking cessation. In stepwise multiple logistic regression, scheduled admission in a month and whether quit date was today were significant predictor variables, Smoking cessation treatment should be tailored to individual smoking patients considering these predictors.

Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity

  • Block, Kai Tobias;Chandarana, Hersh;Milla, Sarah;Bruno, Mary;Mulholland, Tom;Fatterpekar, Girish;Hagiwara, Mari;Grimm, Robert;Geppert, Christian;Kiefer, Berthold;Sodickson, Daniel K.
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.87-106
    • /
    • 2014
  • Purpose : To describe how a robust implementation of a radial 3D gradient-echo sequence with stack-of-stars sampling can be achieved, to review the imaging properties of radial acquisitions, and to share the experience from more than 5000 clinical patient scans. Materials and Methods: A radial stack-of-stars sequence was implemented and installed on 9 clinical MR systems operating at 1.5 and 3 Tesla. Protocols were designed for various applications in which motion artifacts frequently pose a problem with conventional Cartesian techniques. Radial scans were added to routine examinations without selection of specific patient cohorts. Results: Radial acquisitions show significantly lower sensitivity to motion and allow examinations during free breathing. Elimination of breath-holding reduces failure rates for non-compliant patients and enables imaging at higher resolution. Residual artifacts appear as streaks, which are easy to identify and rarely obscure diagnostic information. The improved robustness comes at the expense of longer scan durations, the requirement for fat suppression, and the nonexistence of a time-to-center value. Care needs to be taken during the configuration of receive coils. Conclusion: Routine clinical use of radial stack-of-stars sequences is feasible with current MR systems and may serve as substitute for conventional fat-suppressed T1-weighted protocols in applications where motion is likely to degrade the image quality.

수면 무호흡증 관리를 위한 섬유센서 기반의 슬립 모니터링 스마트 웨어 개발에 관한 연구 (A Study on the Development of Sleep Monitoring Smart Wear based on Fiber Sensor for the Management of Sleep Apnea)

  • 박진희;김주용
    • 감성과학
    • /
    • 제22권1호
    • /
    • pp.89-100
    • /
    • 2019
  • 본 연구에서는 수면무호흡증이 다양한 합병증을 유발하는 질병으로서, 이를 위한 표준화된 수면다원검사가 고가이며 측정이 불편함을 고려하여, 환자가 익숙한 환경에서 검사를 받을 수 있도록 스트레치 섬유센서를 이용한 무구속 상태의 웨어러블 모니터링 시스템을 개발하고자 한다. 또한, 의복과 일체화된 디자인으로 제품화하여 그 유용성을 제안하고자 한다. 성인 남성용 롱 슬리브 티셔츠 형태로 착용형 수면무호흡 모니터링 스마트 의류를 개발하여, 수면무호흡 진단 지표 중 섬유형 센서를 기반으로 측정하는 호흡수(breathing rate)측정용 섬유센서, 산소포화도(oxygen saturation), 호흡기류(airflow)를 실시간 측정하였다. 최적의 조합비 샘플 4가지를 통한 gauge factor를 측정한 결과, gauge factor 20.3을 확인하였고, 3회 숨을 크게 내쉴 때 호흡유량이 최대 2048ml였다. 산소포화도 69.45%로 최소 측정 가능 산소포화도 70% 정도의 결과를 나타내었다. 세탁 후 인장에 따른 센서 성능 평가 결과는 전체적으로 gauge factor 18 수준의 값으로, 세탁에 대한 내구성이 입증되었다. 본 연구를 통하여 수면무호흡증 환자의 수면효율이 떨어지고 여러 합병증을 동반하는 문제에 대해, 가정에서 쉽게 사용할 수 있는 착용형 수면무호흡 모니터링 스마트 의류를 개발하여 호흡수, 호흡유량, 산소포화도의 3가지 지표를 측정 가능함을 확인하였다.

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석 (Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan)

  • 사정호;서태석;최보영;정규회
    • 한국의학물리학회지:의학물리
    • /
    • 제11권1호
    • /
    • pp.59-71
    • /
    • 2000
  • CT검사시 선량이 각 장기에 미치는 영향을 관찰 하고자 하였으며, 선정한 3부위(뇌, 흉부, 복부) 스캔에서 주 선속 및 주 선속외에 미치는 흡수선량을 측정 제시하고, 자궁에 영향을 주는 부위 스캔을 명확히 알고자 하였다. CT기계(Somatom plus 4, Siemens co, Germany)를 이용하였으며 인체에 조직등가 물질이 비슷한 Alderson Rando phantom (Alderson Reserch Laboratories, USA)과 Harshaw chemical 사에서 제작된 열형광선량계 Thermoluminescent dosimeter (TLD)-100 과 Reader와 Oven을 이용하였다. TLD 교정시에, 6MV 선형가속기와 $30{\times}30{\times}1.5$cm의 정사각형 고체 물팬텀을 사용하였다. TLD를 팬텀의 목적장기에 삽입시키기 위하여, 여성환자 (20세~40세) 40명의 영상을 이용하였으며, 위치 측정부위는 간, 위장, 비장, 신장, 대장, 방광, 자궁을 대상으로 하였다. Brain에서의 흡수선량 분포도에서 8 : 8(피치1) 에서는 비장까지 흡수선량이 측정되었으며 10 : 10 에서는 유방까지 흡수선량이 측정되었다. 흥부(Chest)에서의 흡수선량 분포도에서 8 : 8(피치1)에서의 주 선속 흡수선량이 높았다. Abdomen의 흡수선량 분포도에서 8 : 8 과 8 : 10의 스캔을 했을 때 주 선속 부위에서는 테이블 이동이 느린 8mm에서 흡수선량이 높게 나타났다. 뇌 CT의8 : 8과 10 : 10에서 자궁에 미치는 선량은 모두 없었으며, 몸 전체에 미치는 유효선량은 10 : 10 약간 높게 나타났다. Brain CT 에서 임산부나 임신가능 여성에게는 본 논문에서 확인된 방법으로 절편 두께를 8mm-10mm범위로 적용하는 것이 바람직 하고, Chest scan에서 8 : 10(피치 1.2)방법을 선택하는 것이 좋으며, 임산부나 임신 가능 환자에게는 10 : 15(피치 1.5)를 사용하는 것이 좋은 것으로 사료된다. Abdomen scan에서 유효선량이 10.707 mSv, MSAD가 7.2인 8 : 10을 택하는 것이 주 선속에 미치는 영향뿐만 아니라 생식선 장기인 Uterus에 미치는 영향이 비교적 적게 나타나, 다른 기법보다 다소 환자에게 적게 영향을 주며 검사 할 수 있다고 사료된다.

  • PDF

진폭 기반 호흡연동 체적변조회전방사선치료의 선량학적 평가 (Dosimetric Evaluation of Amplitude-based Respiratory Gating for Delivery of Volumetric Modulated Arc Therapy)

  • 이창열;김우철;김헌정;박정훈;민철기;신동오;최상현;박승우;허현도
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.127-136
    • /
    • 2015
  • 본 연구의 목적은 진폭 기반 호흡연동 체적변조회전방사선치료의 선량학적인 평가를 하고자 한다. 이 치료를 받은 환자의 호흡 Log 파일을 획득하여 분석하였으며, 4D CT 호흡 형태의 40%~60% 위상 영상 구간 진폭을 기준으로 치료 Log 파일 호흡 진폭의 구간이 4D CT의 진폭 구간과 일치하는 호흡 형태(CBP)와 일치하지 않는 호흡 형태(IBP)로 구분하였다. 상대적인 등선량 분포는 EBT3 필름을 사용하여 측정하였으며, 절대 선량 측정은 PTW $0.6cm^3$ 이온전리함을 이용하여 측정하였다. 감마 인덱스 3%/3 mm을 적용한 환자 1, 2, 3의 CBP 호흡인 경우 각각 93.18%, 91.16%, 95.46%이며, 환자 1, 2, 3의 IBP 호흡인 경우 각각 66.77%, 48.79%, 40.36%으로 분석되었다. 또한 감마 인덱스 2%/2 mm을 적용한 환자 1, 2, 3의 CBP 호흡인 경우 각각 73.05%, 67.14%, 86.85%이며, IBP 호흡인 경우 각각 46.53%, 32.73%, 36.51%으로 분석되었다. 모든 CBP호흡인 경우의 이온전리함 측정값은 치료계획 시스템에서 계산된 값과 평균 3.5% 이내로 일치하였으며, 정적인 팬톰 조사와의 차이는 평균 2.0% 이내로 일치하였다. 환자 3의 IBP 호흡인 경우 이온전리함 측정값과 계산된 값과의 차이가 평균 56%로 큰 차이를 보였다. 이는 4D CT의 진폭 구간과 치료시의 진폭 구간의 차이가 크기 때문인 것으로 사료되며, 4D CT 모의 치료시와 환자 치료시의 진폭의 크기를 일정하게 유지하는 것이 중요하다고 판단된다.

췌담관자기공명영상에서 2D TSE(RT)와 3D GRASE(BH) 기법에 대한 영상의 질 평가 : Fast MRCP 기법 (Evaluation of Image Quality for 2D TSE(RT) and 3D GRASE in MRCP Study: Fast MRCP Method)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.983-989
    • /
    • 2021
  • 본 연구에서는 환자상태가 좋지 않은 환자에게 적용하기 위하여 Fast MRCP 검사 방법를 이용한 2D TSE(RT)와 3D GRASE(BH) 기법에 적용하여 영상의 질을 평가하고 임상에 기초자료로 제공하고자한다. MRCP 검사를 시행한 환자 30명(남자 15명, 여자 15명, 평균나이 64±4.26)을 대상으로 데이터를 분석하였다. 사용된 장비는 Ingenia CX 3.0 T 장비를 사용하였고 Data 획득은 Ds anterior Coil을 사용하였다. 정량적 분석으로 각 영상의 SNR과 CNR을 측정하고 정성적 평가를 위해 5등급으로 나누어 영상의 질을 평가하였다. 영상평가는 paired t-test와 wilcoxon 검정을 하였으며 p 값이 0.05 이하 일 때 유의성이 있는 것으로 간주하였다. SNR과 CNR에 대한 정량적 분석 결과 2D TSE(RT) MRCP 와 3D GRASE(BH) 두 기법을 비교했을 때 3D GRASE(BH)가 높게 측정되었다(p<0.05). 정성적 분석결과는 담관의 선예도: 3D GRASE(BH):4.12 ± 0.03, 전반적인 영상의 질: 3D GRASE(BH):4.21 ± 0.91로 높게 나타났다(p=0.001). 담관의 움직임 인공물은 두 기법(2D TSE(RT): 4.41 ± 0.04, 3D GRASE(BH): 4.53 ± 0.14로 유의성 있는 차이를 보이지 않았다(p=0.067). 그러나 배경소거부분은 2D TSE(RT)가 4.14 ± 0.55로 유의성 있는 결과를 얻었다(p=0.001). 결론적으로, Fast MRCP 검사방법을 이용한 결과 3D GRASE (BH)로 획득한 MRCP 영상이 2D TSE(RT)를 사용한 MRCP 영상에 비해 우위의 결과를 얻었다. 그러나, 호흡을 참기 힘든 환자의 경우 2D TSE(RT) MRCP 기법이 유용성이 있는 결과가 있을 것이다.