• Title/Summary/Keyword: Breast magnetic resonance imaging

Search Result 123, Processing Time 0.021 seconds

Infective Costochondritis after Augmentation Mammoplasty: A Rare Case Report and Review of the Literature

  • Sally Min;Jinil Choi;Kwon Joong Na;Ki Yong Hong
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.488-491
    • /
    • 2023
  • Silicone breast implant insertion is a commonly performed surgical procedure for breast augmentation or reconstruction. Among various postoperative complications, infection is one of the main causes of patient readmission and may ultimately require explantation. We report a case of infective costochondritis after augmentation mammoplasty, which has rarely been reported and is therefore difficult to diagnose. A 36-year-old female visited the clinic for persistent redness, pain, and purulent discharge around the left anteromedial chest, even after breast implant explantation. Magnetic resonance imaging showed abscess formation encircling the left fourth rib and intracartilaginous and bone marrow signal alteration at the left body of the sternum and left fourth rib. En bloc resection of partial rib and adjacent sternum were done and biopsy results confirmed infective costochondritis. Ten months postoperatively, the patient underwent chest wall reconstruction with an artificial bone graft and acellular dermal matrix. As shown in this case, early and aggressive surgical debridement of the infected costal cartilage and sternum should be performed for infective costochondritis. Furthermore, delayed chest wall reconstruction could significantly contribute to the quality of life.

Suggested Protocol for Efficient Medical Image Information Exchange in Korea: Breast MRI (효율적 의료영상정보교류를 위한 프로토콜 제안: 유방자기공명영상)

  • Park, Ji Hee;Choi, Seon-Hyeong;Kim, Sungjun;Yong, Hwan Seok;Woo, Hyunsik;Jin, Kwang Nam;Jeong, Woo Kyoung;Shin, Na-Young;Choi, Moon Hyung;Jung, Seung Eun
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.254-258
    • /
    • 2018
  • Purpose: Establishment of an appropriate protocol for breast magnetic resonance imaging (MRI) in the study of image quality standards to enhance the effectiveness of medical image information exchange, which is part of the construction and activation of clinical information exchange for healthcare informatization. Materials and Methods: The recommended protocols of breast and MRI scans were reviewed and the questionnaire was prepared by a responsible researcher. Then, a panel of 9 breast dedicated radiologists was set up in Korea. The expert panel conducted a total of three Delphi agreements to draw up a consensus on the breast MRI protocol. Results: The agreed breast MRI recommendation protocol is a 1.5 Tesla or higher device that acquires images with prone position using a breast dedicated coil and includes T2-weighted and pre-contrast T1-weighted images. Contrast enhancement images are acquired at least two times, and include 60-120 seconds between images and after 4 minutes. The contrast enhancement T1-weighted image should be less than 3 mm in thickness, less than 120 seconds in temporal resolution, and less than $1.5mm^2$ in-plane pixel resolution. Conclusion: The Delphi agreement of the domestic breast imaging specialist group has established the recommendation protocol of the effective breast MRI.

Benign Adenomyoepithelioma of the Breast: Imaging Characteristics (유방의 양성 선근상피세포종: 영상 특징)

  • So Ra Shin;Eun Young Ko;Boo-Kyung Han;Eun Sook Ko;Ji Soo Choi;Haejung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.398-408
    • /
    • 2023
  • Purpose This study aimed to evaluate the radiological and clinical characteristics of benign adenomyoepitheliomas of the breast. Materials and Methods Over the last 20 years, 120 patients were histologically diagnosed with breast adenomyoepithelioma (AME) at our institution. We excluded 43 patients who were incidentally diagnosed during mastectomy for breast cancer, 28 who underwent percutaneous biopsy without further excision, and 8 who had biopsy-confirmed benign AME and were found to have another pathology after complete excision. We retrospectively reviewed the clinical records and radiological findings of the remaining 41 patients with histologically diagnosed benign breast AMEs after complete excision. Results All 41 patients underwent US; 38 underwent mammography (MG) and US; and 18 underwent MG, US, and MRI. MG detected 38 cases with a round or oval shape (56%), and mass (89%), were non-circumscribed (62%), hyperdense (53%), and without microcalcifications (95%). Breast US revealed suspicious masses (98%) with a non-circumscribed margin (66%), hypoechogenicity (43%), and intratumoral vascularity (63%). All lesions on breast MRI showed suspicious masses (100%) with ill-defined margins (61%), and 84% showed wash-out kinetics. Benign AMEs showed suspicious features of Breast Imaging Reporting and Data System (BI-RADS) category 4 or 5 in 83%-95% of the MG, US, and MRI. Sixteen of the 41 cases were misdiagnosed on the initial core needle biopsy and two were diagnosed as malignancy. Conclusion Benign breast AME often shows suspicious radiological features mimicking a malignant mass on MG, US, and MRI. Differentiating benign AME from other pathologies might be difficult on core needle biopsy, and complete excision is needed for a correct diagnosis.

Primary Malignant Melanoma of the Breast Presenting as a Breast Abscess: A Case Report (유방 농양으로 발현한 유방의 원발성 악성 흑색종: 증례 보고)

  • Hyung In Choi;You Me Kim;Junwon Min;Yong Moon Lee;Hee Jeong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.763-769
    • /
    • 2023
  • Primary malignant melanoma in breast parenchyma (PMB) is an extremely rare disease, and the most common presentation is a palpable breast lump. To the best of our knowledge, a case of PMB presenting as a breast abscess has not been reported in English literatures. We present a case of PMB that manifested as a recurrent breast abscess in a 71-year-old woman. On MRI, an enhancing solid mass with a cystic or necrotic portion was revealed with some high signal intensities on precontrast-enhanced T1-weighted images and a dark rim on T2-weighed images. The MRI features played a pivotal role in identifying the underlying malignant condition and making an accurate diagnosis of this rare case of PMB with unusual clinical presentation.

Scoring System to Predict Malignancy for MRI-Detected Lesions in Breast Cancer Patients: Diagnostic Performance and Effect on Second-Look Ultrasonography (유방암 환자의 MRI에서 발견된 병변의 악성 예측을 위한 점수체계: 진단적 능력과 이차 초음파 결정에 미치는 영향)

  • Young Geol Kwon;Ah Young Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.379-394
    • /
    • 2020
  • Purpose To design a scoring system to predict malignancy of additional MRI-detected lesions in breast cancer patients. Materials and Methods Eighty-six lesions (64 benign and 22 malignant) detected on preoperative MRI of 68 breast cancer patients were retrospectively included. The clinico-radiologic features were correlated with the histopathologic results using the Student's t-test, Fisher's exact test, and logistic regression analysis. The scoring system was designed based on the significant predictive features of malignancy, and its diagnostic performance was compared with that of the Breast Imaging-Reporting and Data System (BI-RADS) category. Results Lesion size ≥ 8 mm (p < 0.001), location in the same quadrant as the primary cancer (p = 0.005), delayed plateau kinetics (p = 0.010), T2 isointense (p = 0.034) and hypointense (p = 0.024) signals, and irregular mass shape (p = 0.028) were associated with malignancy. In comparison with the BI-RADS category, the scoring system based on these features with suspicious non-mass internal enhancement increased the diagnostic performance (area under the receiver operating characteristic curve: 0.918 vs. 0.727) and detected three false-negative cases. With this scoring system, 22 second-look ultrasound examinations (22/66, 33.3%) could have been avoided. Conclusion The scoring system based on the lesion size, location relative to the primary cancer, delayed kinetic features, T2 signal intensity, mass shape, and non-mass internal enhancement can provide a more accurate approach to evaluate MRI-detected lesions in breast cancer patients.

Ultrafast MRI and T1 and T2 Radiomics for Predicting Invasive Components in Ductal Carcinoma in Situ Diagnosed With Percutaneous Needle Biopsy

  • Min Young Kim;Heera Yoen;Hye Ji;Sang Joon Park;Sun Mi Kim;Wonshik Han;Nariya Cho
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1190-1199
    • /
    • 2023
  • Objective: This study aimed to investigate the feasibility of ultrafast magnetic resonance imaging (MRI) and radiomic features derived from breast MRI for predicting the upstaging of ductal carcinoma in situ (DCIS) diagnosed using percutaneous needle biopsy. Materials and Methods: Between August 2018 and June 2020, 95 patients with 98 DCIS lesions who underwent preoperative breast MRI, including an ultrafast sequence, and subsequent surgery were included. Four ultrafast MRI parameters were analyzed: time-to-enhancement, maximum slope (MS), area under the curve for 60 s after enhancement, and time-to-peak enhancement. One hundred and seven radiomic features were extracted for the whole tumor on the first post-contrast T1WI and T2WI using PyRadiomics. Clinicopathological characteristics, ultrafast MRI findings, and radiomic features were compared between the pure DCIS and DCIS with invasion groups. Prediction models, incorporating clinicopathological, ultrafast MRI, and radiomic features, were developed. Receiver operating characteristic curve analysis and area under the curve (AUC) were used to evaluate model performance in distinguishing between the two groups using leave-one-out cross-validation. Results: Thirty-six of the 98 lesions (36.7%) were confirmed to have invasive components after surgery. Compared to the pure DCIS group, the DCIS with invasion group had a higher nuclear grade (P < 0.001), larger mean lesion size (P = 0.038), larger mean MS (P = 0.002), and different radiomic-related characteristics, including a more extensive tumor volume; higher maximum gray-level intensity; coarser, more complex, and heterogeneous texture; and a greater concentration of high gray-level intensity. No significant differences in AUCs were found between the model incorporating nuclear grade and lesion size (0.687) and the models integrating additional ultrafast MRI and radiomic features (0.680-0.732). Conclusion: High nuclear grade, larger lesion size, larger MS, and multiple radiomic features were associated with DCIS upstaging. However, the addition of MS and radiomic features to the prediction model did not significantly improve the prediction performance.

Functional Magnetic Resonance Imaging in the Diagnosis of Locally Recurrent Prostate Cancer: Are All Pulse Sequences Helpful?

  • Liao, Xiao-Li;Wei, Jun-Bao;Li, Yong-Qiang;Zhong, Jian-Hong;Liao, Cheng-Cheng;Wei, Chang-Yuan
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1110-1118
    • /
    • 2018
  • Objective: To perform a meta-analysis to quantitatively assess functional magnetic resonance imaging (MRI) in the diagnosis of locally recurrent prostate cancer. Materials and Methods: A comprehensive search of the PubMed, Embase, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews was conducted from January 1, 1995 to December 31, 2016. Diagnostic accuracy was quantitatively pooled for all studies by using hierarchical logistic regression modeling, including bivariate modeling and hierarchical summary receiver operating characteristic (HSROC) curves (AUCs). The Z test was used to determine whether adding functional MRI to T2-weighted imaging (T2WI) results in significantly increased diagnostic sensitivity and specificity. Results: Meta-analysis of 13 studies involving 826 patients who underwent radical prostatectomy showed a pooled sensitivity and specificity of 91%, and the AUC was 0.96. Meta-analysis of 7 studies involving 329 patients who underwent radiotherapy showed a pooled sensitivity of 80% and specificity of 81%, and the AUC was 0.88. Meta-analysis of 11 studies reporting 1669 sextant biopsies from patients who underwent radiotherapy showed a pooled sensitivity of 54% and specificity of 91%, and the AUC was 0.85. Sensitivity after radiotherapy was significantly higher when diffusion-weighted MRI data were combined with T2WI than when only T2WI results were used. This was true when meta-analysis was performed on a per-patient basis (p = 0.027) or per sextant biopsy (p = 0.046). A similar result was found when $^1H$-magnetic resonance spectroscopy ($^1H$-MRS) data were combined with T2WI and sextant biopsy was the unit of analysis (p = 0.036). Conclusion: Functional MRI data may not strengthen the ability of T2WI to detect locally recurrent prostate cancer in patients who have undergone radical prostatectomy. By contrast, diffusion-weight MRI and $^1H$-MRS data may improve the sensitivity of T2WI for patients who have undergone radiotherapy.

The clinical usefulness of fat suppression by chemical shift selective(CHESS) pulse in MRI (MRI에서 화학적 이동 선택(CHESS) pulse에 의한 지방소거의 임상적 유용성)

  • Han, Man-Seok;Yang, Hae-Sool;Jin, Kyung-Soo;Eo, Ik-Soo;Cho, Dong-Heon
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.431-436
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has chemical shift phenomenon between fat and water, and the phenomenon has influence on structure enclosed by fat. Strong signals emitted from fat often generate false artefact, which reflects the importance of fat suppression techniques. There have been a number of researches on fat suppression techniques, but using fat suppression method alone in MRI can cause difficultproblems in diagnosis. This paper aims to study a fat suppression method by Chemical Shift Selective saturation(CHESS). This research describes the theoretical background and the experiment on water and fat phantom with MR instruments. In the experiment, CHESS pulse was designed by utilising Matlap program, and the pulse diagram was generated for the Pre-saturation process. The experiment using water and fat phantom was applied to C-spine, L-spine and Breast, and produced successful fat suppression results. This experiment has proved that the CHESSpulse fat suppression is a very helpful technique in diagnosing medical imaging. This method is a robust and useful technique for both clinical and basic investigators..(Experiment with Chungnam national university hospital G.E 1.5T MR)

Multiple Primary Malignant Neoplasms: A Case Report of Breast Mucinous Carcinoma and Extramammary Diffuse Large B-Cell Lymphoma in a Male Patient (다발성 원발성 악성종양: 남성 환자에서 유방의 점액성 선암과 유방외 미만성 거대 B세포 림프종이 병발한 증례 보고)

  • Su Young Kim;Ji Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.729-736
    • /
    • 2021
  • Multiple primary malignant neoplasms refer to two or more malignancies in an individual that are not related. We report a case of a 78-year-old male with concurrent breast mucinous carcinoma and extramammary lymphoma. The patient initially presented with palpable masses in the left breast and the right groin, which were pathologically confirmed after a surgical biopsy as breast mucinous carcinoma and diffuse large B-cell lymphoma, respectively. He underwent whole-body 18-fluorine deoxyglucose PET/CT before surgery, and an enhancing nodular lesion in the left lingual tonsil was found incidentally. It was later confirmed as a diffuse large B-cell lymphoma, a pathology of the same type as the right inguinal mass. Unspecified lymphadenopathies in breast cancer patients may easily be considered as metastatic lesions. However, this case suggests that lymphomas should be included in the differential diagnoses to avoid misdiagnosis and treatment delay, especially in older adult patients.

Assessment of Detection Rate Applying the Digital Convergence Mammographic Imaging Methods(FFDM, DBT, BMRI): Based on Breast Density (디지털 융복합 유방 영상 검사기법(FFDM, DBT, BMRI)을 사용한 검출률 평가 : 유방밀도에 근거하여)

  • Jang, Eun-Hee;Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.281-291
    • /
    • 2017
  • This study aimed to assess detection rate applying the mammographic imaging methods. The evaluation of the shape and margin of tumor was conducted by score oriented to 180 patients who had undergone FFDM, DBT and BMRI scans among breast cancer patients, and the number of calcification was classified by size. There was no significant difference between DBT and BMRI for tumors larger than 1 cm in low-density breasts and for tumors larger than 2 cm in high-density breasts. Moreover, as for the detection rate of number of fine calcification, the highest rate was observed in FFDM followed by DBT and BMRI in the order named regardless of size. In conclusion, DBT was able to be detected even without BMRI if the mass was larger than 1 cm in the low-density breast and larger than 2 cm in the high-density breast. The detection rate of calcification turned out to be the highest in FFDM followed by DBT regardless of size, and calcification was not observed by BMRI. The appropriate use of FFDM, DBT and BMRI with respect to mass tumor will contribute to serving as a guide to examination methods of reducing burden of patients.