• Title/Summary/Keyword: Breast image

Search Result 287, Processing Time 0.027 seconds

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

An Analysis of Research on Postpartum Weight Retention (산후체증정체(Postpartum Weight Retention)관련 국외 연구논문 분석)

  • Lee, Seoung-Eun;Yoo, Eun-Kwang
    • Women's Health Nursing
    • /
    • v.9 no.3
    • /
    • pp.287-298
    • /
    • 2003
  • Purpose: To explain the concept of postpartum weight retention and to analyze factor effect on it. Method: A total of 20 studies related postpartum weight retention were selected in the year of 1988-2001 and analysis was done. Result: A demographic factor like parity, age, social and economic level and life style such as exercise, diet, breast feeding are influential factor on postpartum retention weight. But parts of them don't agree the same results. Meanwhile, in some studies, psychological factor like women's self esteem related to postpartum retention weight, body image change, depressing is found to be very related. As a result, postpartum overweight gain could be a bad factor of physical and mental health. In Korea, we have few studies related to them. Conclusion: It is required to do many-sided and deep studies about aspects of postpartum retention weight and the factor that effect on it. Postpartum retention weight should be approached by controling weight from the period of pregnancy. And it would rather be researched through individual approach considered women's various demographic, social-cultural and physical level than be required standardized level of weight gain.

  • PDF

A Study on 3D Surface Reconstruction for the Breast of Human Body (인체 가슴 부위의 구조물의 3D 표면 모형 재구성)

  • Lee, Sang-Tae;Jeon, Hyun-Jin;Kim, Ki-Tai;Choi, Ki-Seok;Joo, Won-Kyun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.99-102
    • /
    • 2009
  • 본 연구에서는 실제 기증받은 시체를 이용하여 인체의 각 구조물을 실제 모습 그대로 3D 이미지화하는 과정에 대해 알아보았다. 인체의 구조물을 3D 로 이미지화하는 과정은 다음과 같다. 먼저 시체를 0.2mm 간격으로 절단하여 절단면의 사진을 찍은 후, 각 절단면의 사진에서 각각의 구조물을 구역화하여 색칠을 한 후, 구역화한 이미지에서 외곽선을 추출하여 벡터 이미지를 만든다. 이 외곽선을 1mm 간격으로 쌓아 올린 후 그 표면을 재구성하여 3D 이미지로 변환하는 과정으로 진행되었다. 3D 이미지의 제작은 가슴 부위에 한정하여 이루어졌다. 인체의 해부학적인 모형을 3D 이미지로 시각화함으로써 얻는 효과는 일반인을 대상으로 인체의 내부에 대한 시각적인 호기심을 충족시켜주고 의학 상식을 넓히는데 도움을 줄 수 있을 것 이다. 또한 의대생들을 비롯한 의학 전문가들에게는 생생한 해부학 강의용으로도 활용 가능하다. 향후 Haptic 시스템을 이용한 의료 실습 어플리케이션과 접목될 수도 있을것이고, fMRI 데이터를 비롯한 타 데이터와의 융합을 통해 시각화하여 서비스 할 수도 있다. 이처럼 인체의 3D 모형은 의료분야에서 광범위하게 활용될 수 있는 데이터로써 그 가치를 지닐 것이다.

  • PDF

Microcalcification Extraction by Using Automatic Thredholding Based on Region Growing (영역 성장법을 기반으로 자동적인 임계치 설정을 이용한 미세 석회화 추출)

  • 원철호;권용준;이정현;박희준;임성운;김명남;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.235-242
    • /
    • 2004
  • In this paper, we proposed the algorithm for detection of microtalcification by automatic threshold decision based on region growing method. The region for optimal threshold is grown from local maximum pixel by increasing repeatedly threshold in microralcification candidate region. Then, the optimal threshold is automatically decided at the maximum value of the contrast and edge sharpness in this region. Microcalcifications could be efficiently detected as satisfied result that true positive ratio is 81.5% and average false positive numbers are 1.1 about total 299 microcalcifirations in real image. In a result, we showed that this algorithm can be used to aid diagnostic-radiologist for the diagnosis of the early phase of breast cancer.

Evaluation of Radiolucent Considering the Compression Paddle Materials in Mammography (유방촬영장치의 압박대 재질을 고려한 투과선량 평가)

  • Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.307-312
    • /
    • 2015
  • Mammography improves image quality that is on the increase day by day and get a picture with the pressure it is essential to reduce the dose. However, because due to the thickness of the cuff itself may increase the dose scattering lines is necessary study on the cuff material. Material that is currently being used in clinical Polycarbonate is a plastic and family. If you try to reduce the exposure of patients than itgie need to consider for the better material in this study to compare against a radiolucent line for amorphous plastic material of the plastic. results radiolucent and half layer, transmitting dose Pixel values HIPS, GPPS, ABS, Tritan, PC, PMMA showed high results in the net.

Region Segmentation of a Color Image using a Distributed Genetic Algorithm (분산 유전자 알고리즘을 이용한 컬러 이미지의 영역분할)

  • 조찬윤;김상균
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.5
    • /
    • pp.470-478
    • /
    • 2000
  • Color images from various application areas have their own characteristics. Practical segmentation systems need specialized methods to death with the characteristics. In this paper. we propose a distributed genetic algorithm based segmentation method for color breast carcinoma cell images. To extract positive nuclei and negative nuclei from the cell images, a distributed genetic algorithm with improved genetic operations and an evaluation function is used. As initial values, representative colors from images are introduced to work well with the cell images. A test to verify the validity of the proposed method shows well-segmented images. This result suggests that the method is pertinent to be but into practical use for the images haying limited objects with limited colors.

  • PDF

Chest Wall Lipogranuloma after Hydrogel Implant Rupture: Case Report

  • Park, So Yoon;Han, Boo-Kyung;Cho, Eun Yoon;Bang, Sa-Ik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.191-195
    • /
    • 2015
  • We present a 53-year-old woman with a large chest wall mass in the interpectoral space, which was eventually confirmed as a lipogranuloma resulting from hydrogel implant rupture. Ultrasonography (US) showed reduced implant volume with surrounding peri-implant fluid collection, suggesting the possibility of implant rupture. A heterogeneously hypoechoic mass was found between the pectoralis major and minor muscles adjacent to the ruptured implant. On magnetic resonance imaging (MRI), there was a large mass in the left interpectoral space of the upper inner chest wall. The mass showed slightly high signal intensity (SI) on pre-contrast T1-weighted image (WI) with mixed iso and high SI on T2-WI. The signal of the mass was suppressed using the water suppression technique but not with the fat suppression technique on T2-WI. The mass showed diffuse enhancement upon contrast enhancement. The enhancing kinetics showed persistent enhancement pattern. US-guided core needle biopsy revealed a lipogranuloma and removal confirmed a ruptured PIP hydrogel implant.

Eroticism Shown in the Fashion of Lady Gaga's Music Video (레이디 가가의 뮤직 비디오 패션에 나타난 에로티시즘)

  • Kang, Yoohee;Lee, Misook
    • Journal of Fashion Business
    • /
    • v.17 no.1
    • /
    • pp.13-29
    • /
    • 2013
  • The purpose of this study was to analyze eroticism shown in the fashion of Lady Gaga's music video. This study methods taken theoretical consideration and then was classified eroticism based on previous studies and was analyzed costumes from Lady Gaga's music video. The results of this study were as follows: Avant-garde style exaggerates shoulders, hips, a hat or uses metal and glossy material, tape, leather and it was expressed into emphasizing or baldly exposing breast. Primitive style was expressed in ethnic style and animal patterns, lingerie look with drastic, bald exposing fashion. Romantic style was expressed using rococo style costume, frill, pleats, decoration and was produces eroticism with see-through look or costume fitting to the body. Sportive style expresses a healthier and erotic image using tight costume in yellow, blue and black while exposing belly and legs. Janus-faced style was expressed by dressing up like a man or using the method of attachment and exposure in clergy's costume. Humorous style was expressed by emphasizing parts of body or costume itself. As examined in the above, Lady Gaga was expressed various eroticism images in her music video and is builds her own sexually appealing.

Stiffness Comparison of Tissue Phantoms using Optical Coherence Elastography without a Load Cell

  • Chae, Yu-Gyeong;Park, Eun-Kee;Jeon, Min Yong;Jeon, Byeong-Hwan;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.17-22
    • /
    • 2017
  • Mechanical property of tissue is closely related to diseases such as breast cancer, prostate cancer, cirrhosis of the liver, and atherosclerosis. Therefore measurement of tissue mechanical property is important for a better diagnosis. Ultrasound elastography has been developed as a diagnostic modality for a number of diseases that maps mechanical property of tissue. Optical coherence elastography (OCE) has a higher spatial resolution than ultrasound elastography. OCE, therefore, could be a great help for early diagnosis. In this study, we made tissue phantoms and measured their compressive moduli with a rheometer measuring the response to applied force. Uniaxial strain of the tissue phantom was also measured with OCE by using cross-correlation of speckles and compared with the results from the rheometer. In order to compare stiffness of tissue phantoms by OCE, the applied force should be measured in addition to the strain. We, however, did not use a load cell that directly measures the applied force for each sample. Instead, we utilized one silicone film (called as reference phantom) for all OCE measurements that indirectly indicated the amount of the applied force by deformation. Therefore, all measurements were based on displacement, which was natural and effective for image-based elastography such as OCE.

Rotation Errors of Breast Cancer on 3D-CRT in TomoDirect (토모다이렉트 3D-CRT을 이용한 유방암 환자의 회전 오차)

  • Jung, Jae Hong;Cho, Kwang Hwan;Moon, Seong Kwon;Bae, Sun Hyun;Min, Chul Kee;Kim, Eun Seog;Yeo, Seung-Gu;Choi, Jin Ho;Jung, Joo-Yong;Choe, Bo Young;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.6-11
    • /
    • 2015
  • The purpose of this study was to analyze the rotational errors of roll, pitch, and yaw in the whole breast cancer treated by the three-dimensional radiation therapy (3D-CRT) using TomoDirect (TD). Twenty-patient previously treated with TD 3D-CRT was selected. We performed a retrospective clinical analysis based on 80 images of megavoltage computed tomography (MVCT) including the systematic and random variation with patient setup errors and treatment setup margin (mm). In addition, a rotational error (degree) for each patient was analyzed using the automatic image registration. The treatment margin of X, Y, and Z directions were 4.2 mm, 6.2 mm, and 6.4 mm, respectively. The mean value of the rotational error for roll, pitch, and yaw were $0.3^{\circ}$, $0.5^{\circ}$, $0.1^{\circ}$, and all of systematic and random error was within $1.0^{\circ}$. The errors of patient positioning with the Y and Z directions have generally been mainly higher than the X direction. The percentage in treatment fractions in less than $2^{\circ}$ at roll, pitch, and yaw are 95.1%, 98.8%, and 97.5%, respectively. However, the edge of upper and lower (i.e., bottom) based on the center of therapy region (point) will quite a possibility that it is expected to twist even longer as the length of treatment region. The patient-specific characters should be considered for the accuracy and reproducibility of treatment and it is necessary to confirm periodically the rotational errors, including patient repositioning and repeating MVCT scan.