• 제목/요약/키워드: Breast dose

Search Result 537, Processing Time 0.027 seconds

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Study on Computerized Treatment Plan of Field-in-Field Intensity Modulated Radiation Therapy and Conventional Radiation Therapy according to PBC Algorithm and AAA on Breast Cancer Tangential Beam (유방암 접선조사에서 PBC 알고리즘과 AAA에 따른 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy 전산화 치료계획에 대한 고찰)

  • Yeom, Mi-Suk;Bae, Seong-Soo;Kim, Dae-Sup;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.11-14
    • /
    • 2012
  • Purpose: Anisotropic Analytical Algorithm (AAA) provides more accurate dose calculation regarding impact on scatter and tissue inhomogeneity in comparison to Pencil Beam Convolution (PBC) algorithm. This study tries to analyze the difference of dose distribution according to PBC algorithm and dose calculation algorithm of AAA on breast cancer tangential plan. Materials and Methods: Computerized medical care plan using Eclipse treatment planning system (version 8.9, VARIAN, USA) has been established for the 10 breast cancer patients using 6 MV energy of Linac (CL-6EX, VARIAN, USA). After treatment plan of Conventional Radiation Therapy plan (Conventional plan) and Field-in-Field Intensity Modulated Radiation Therapy plan (FiF plan) using PBC algorithm has been established, MU has been fixed, implemented dose calculation after changing it to AAA, and compared and analyzed treatment plan using Dose Volume Histogram (DVH). Results: Firstly, as a result of evaluating PBC algorithm of Conventional plan and the difference according to AAA, the average difference of CI value on target volume has been highly estimated by 0.295 on PBC algorithm and as a result of evaluating dose of lung, $V_{47Gy}$ and $V_{45Gy}$ has been highly evaluated by 5.83% and 4.04% each, Mean dose, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$ has been highly evaluated 0.6%, 0.29%, 6.35%, 10.23% each on AAA. Secondly, in case of FiF plan, the average difference of CI value on target volume has been highly evaluated on PBC algorithm by 0.165, and dose on ipsilateral lung, $V_{47Gy}$, $V_{45Gy}$, Mean dose has been highly evaluated 6.17%, 3.80%, 0.15% each on PBC algorithm, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$ has been highly evaluated 0.14%, 4.07%, 4.35% each on AAA. Conclusion: When calculating with AAA on breast cancer tangential plan, compared to PBC algorithm, Conformity on target volume of Conventional plan, FiF plan has been less evaluated by 0.295, 0.165 each. For the reason that dose of high dose region of ipsilateral lung has been showed little amount, and dose of low dose region has been showed much amount, features according to dose calculation algorithm need to be considered when we evaluate dose for the lungs.

  • PDF

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

Clinical Implementation of an In vivo Dose Verification System Based on a Transit Dose Calculation Tool for 3D-CRT

  • Jeong, Seonghoon;Yoon, Myonggeun;Chung, Weon Kuu;Chung, Mijoo;Kim, Dong Wook
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1571-1576
    • /
    • 2018
  • We developed and evaluated an algorithm to calculate the target radiation dose in cancer patients by measuring the transmitted dose during 3D conformal radiation treatment (3D-CRT) treatment. The patient target doses were calculated from the transit dose, which was measured using a glass dosimeter positioned 150 cm from the source. The accuracy of the transit dose algorithm was evaluated using a solid water phantom for five patient treatment plans. We performed transit dose-based patient dose verification during the actual treatment of 34 patients who underwent 3D-CRT. These included 17 patients with breast cancer, 11 with pelvic cancer, and 6 with other cancers. In the solid water phantom study, the difference between the transit dosimetry algorithm with the treatment planning system (TPS) and the measurement was $-0.10{\pm}1.93%$. In the clinical study, this difference was $0.94{\pm}4.13%$ for the patients with 17 breast cancers, $-0.11{\pm}3.50%$ for the eight with rectal cancer, $0.51{\pm}5.10%$ for the four with bone cancer, and $0.91{\pm}3.69%$ for the other five. These results suggest that transit-dosimetry-based in-room patient dose verification is a useful application for 3D-CRT. We expect that this technique will be widely applicable for patient safety in the treatment room through improvements in the transit dosimetry algorithm for complicated treatment techniques (including intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT).

The Study of Dose Variation and Change of Heart Volume Using 4D-CT in Left Breast Radiation Therapy (좌측 유방 방사선치료 시 4D-CT를 이용한 심장의 체적 및 선량변화에 대한 연구)

  • Park, Seon Mi;Cheon, Geum Seong;Heo, Gyeong Hun;Shin, Sung Pil;Kim, Kwang Seok;Kim, Chang Uk;Kim, Hoi Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.187-192
    • /
    • 2013
  • Purpose: We investigate the results of changed heart volume and heart dose in the left breast cancer patients while considering the movements of respiration. Materials and Methods: During the months of March and May in 2012, we designated the 10 patients who had tangential irradiation with left breast cancer in the department of radiation Oncology. With acquired images of free breathing pattern through 3D and 4D CT, we had planed enough treatment filed for covered up the whole left breast. It compares the results of the exposed dose and the volume of heart by DVH (Dose Volume histogram). Although total dose was 50.4 Gy (1.8 Gy/28 fraction), reirradiated 9 Gy (1.8 Gy/5 Fraction) with PTV (Planning Target Volume) if necessary. Results: It compares the results of heart volume and heart dose with the free breathing in 3D CT and 4D CT. It represents the maximum difference volume of heart is 40.5%. In addition, it indicated the difference volume of maximum and minimum, average are 8.8% and 27.9%, 37.4% in total absorbed dose of heart. Conclusion: In case of tangential irradiation (opposite beam) in left breast cancer patients, it is necessary to consider the changed heart volume by the respiration of patient and the heartbeat of patient.

  • PDF

Evaluation of the Usefulness of 3D Printed Shielding Materials Using Monte Carlo Simulation during Mammography (유방 X선 검사 시 몬테카를로 시뮬레이션을 이용한 3D 프린팅 차폐재료의 효용성 평가)

  • Cho, Yong In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.295-301
    • /
    • 2020
  • Radiation exposure exposed during mammography, which is performed for early examination of breast cancer, has also been suggested as a cause of carcinogenesis in the past, and scattered rays generated during examination may cause unnecessary radiation exposure to surrounding organs. In this study, the Monte Carlo simulation was used to evaluate the human organ doses exposed during conventional mammography, and to estimate the dose reduction effect for each organ when using 3D printing materials for radiation protection by scattered rays. As a result of organ dose evaluation, the breast on the opposite side of the examination was about 22.0% of the breast on the test side and about 58.6% on the eye, which was highly influenced by the scattering-ray. When using the 3D printing shield to protect it, the breast on the opposite side of the test showed an effective dose reduction effect at a thickness of 1 mm.

Clinical Study on Safety of Cantharidin Sodium and Shenmai Injection Combined with Chemotherapy in Treating Patients with Breast Cancer Postoperatively

  • Wang, Lin;Huang, Xin-En;Cao, Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5597-5600
    • /
    • 2014
  • Objectives: To assess side effects on Cantharidin sodium and Shenmai injection combined with chemotherapy in treating patients with breast cancer postoperatively. Method: Patients with breast cancer receiving postoperative chemotherapy were retrospectively collected, and divided into four groups: group A with cantharidin sodium injection combined with chemotherapy; group B with Shenmai injection combined with chemotherapy; group C with both cantharidin sodium and Shenmai injection combined with chemotherapy; while group D (control group) received chemotherapy alone. All patients were administered docetaxel at a dose of $75mg/m^2$ on day 1, epirubicin hydrochloride at a dose of $60mg/m^2$ on day 1, and cyclophosphamide at a dose of $500mg/m^2$ on day 1 for 3 cycles (repeated at 21 day intervals). After ${\geq}$ three courses of treatment, quality of life and side effects were evaluated. Results: There were a total of 78 patients in this study, and the incidence of leukopenia and gastrointestinal reactions in groups A and B were lower than those in the control group and lowest in group C (p<0.05). Conclusions: Thus cantharidin sodium and Shenmai injection combined with chemotherapy reduce side effects and deserve to be further investigated in randomized clinical control trials.

Effect of [6] -Gingerol on Inhibition of Cell Proliferation in MDA-MB-231 Human Breast Cancer Cells ([6]-Gingerol이 인체 유방암세포인 MDA-MB-231의 세포증식 억제에 미치는 영향)

  • Seo Eun-Young;Lee Hyun-Sook;Kim Woo-Kyung
    • Journal of Nutrition and Health
    • /
    • v.38 no.8
    • /
    • pp.656-662
    • /
    • 2005
  • Ginger (Zingiber of oficinale Roscoe, Zingiberaceae) is one of the most frequently and heavily consumed dietary condiments throughout the world. Besides its extensive use as a spice, the rhizome of ginger has also been used in traditional oriental herbal medicine for the management of symptoms such as common cold, digestive disorders, rheumatism, neurologia, colic, and motion-sickness. The oleoresin from rhizomes of ginger contains [6] -gingerol (1- [4'-hydroxy-3'-methoxyphenyl]-5-hydroxy-3-decanone) and its homologs as pungent ingredients that have been found to possess many interesting pharmacological and physiological activities, such as anti-inflammatory, analgesic, antipyretic, antiheatotoxic, and cardiotonic effects. However, the effect of [6]-gingerol on cell proliferation in breast cancer cell are not currently well known. Therefore, in this study, we examined effect of [6]-gingerol on protein and mRNA expression associated with cell proliferation in MDA-MB-231 human breast. cancer cell lines. We cultured MDA-MB-231 cells in presence of 0, 2.5, 5 and $10{\mu}M$ of [6] -gingerol. [6]-Gingerol inhibited breast cancer cell growth in a dose-depenent manner as determined by MTT assay. ErbB2 and ErbB3 protein and mRNA expression were decreased dose-dependently in cells treated with [6]-gingerol (p<0.05). In addition, phosphorylated Akt levels and total hぉ levels were markedly decreased in cells treated with $2.5{\mu}M$ [6]-gingerol (p<0.05). In conclusion, we have shown that [6]-gingerol inhibits cell proliferation through ErbB2 and ErbB3, reduction in MDA-MB-231 human breast cancer cell lines.

Efficacy of Dose Dense Doxorubicin and Cyclophosphamide Followed by Paclitaxel versus Conventional Dose Doxorubicin, Cyclophosphamide Followed by Paclitaxel or Docetaxel in Patients with Node-Positive Breast Cancer

  • Yazilitas, Dogan;Sendur, Mehmet Ali Nahit;Karaca, Halit;Ozdemir, Nuriye;Aksoy, Sercan;Berk, Veli;Yazici, Ozan;Ozturk, Banu;Ozkan, Metin;Zengin, Nurullah;Altundag, Kadri
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1471-1477
    • /
    • 2015
  • Background: Adding taxanes to adjuvant antracycline and cyclophosphamide (AC) in combination may provide significant improvement in node-positive and high risk node-negative breast cancer (BC) patients. However, the optimal dose and the role of dose-dense (DD) chemotherapy have yet to be determined. The aim of this study was to compare the efficacy of a DD paclitaxel (P)-AC combination with conventional weekly P-AC or docetaxel D-AC combinations in patients with node-positive breast cancer. Materials and Methods: Newly diagnosed 280 node-positive BC patients diagnosed from 1998 to 2013 in three clinics were retrospectively analyzed. Demographic and medical data were collected from the medical charts. Patients were categorized to 3 groups according to treatment arms: arm A, ddAC-P; arm B, weekly P and AC combination; and arm C; T and AC combination. Adjuvant trastuzumab was added for HER2-positive patients. Kaplan-Meier survival analysis was carried out for disease free survival (DFS) and overall survival (OS). The log-rank test was used to examine the statistical significance of the differences observed between the groups. Two-sided P values <0.05 were considered statistically significant. Results: Of the total of 280 patients, 101 were in arm A, 114 in arm B and 65 in arm C.The median ages were 49, 50 and 46, respectively (p=0.11). Median follow-up was 39 (3-193) months. Stage, lymphovascular and perineural invasion, receptor patern, and menopausal status were similar in the 3 treatment arms, but HER2 positivity was significantly lower in arm A, compared to arms B and C (25.7%, 53.1%, 41.5% in arms A, B and C, respectively; p<0.001). Also grade 3 tumors were significantly less frequent in treatment arm A compared to arm B and C (27.3%, 56.8% and 49.2%, respectively, p=0.01). Afterunivariate and multivariate analysis were performed, 3-year DFS rates were 89%, 81%, and 75%, respectively (p=0.12) and three year OS rates were 96.6%, 89%, and 75% (p=0.62). Conclusions: In this study, no significant difference was found between adjuvant dose dense and conventional taxane treatment regimens.

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.