• Title/Summary/Keyword: Breakdown experiment

Search Result 199, Processing Time 0.024 seconds

Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

A Study on Electrical Characteristics of Field Stop IGBT with Separated Gate Structure (분리된 게이트 구조를 갖는 필드 스톱 IGBT의 전기적 특성에 관한 연구)

  • HyeongSeong Jo;Jang Hyeon Lee;Kung Yen Lee;Ey Goo Kang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.609-613
    • /
    • 2023
  • In this paper, a 1,200 V Si-based IGBT used in electric vehicles and new energy industries was designed. A field stop IGBT with a separate gate structure, which is the proposed structure, was designed to change trench depth and split gate width variables. Then, the general trench structure and electrical characteristics were compared and analyzed. As a result of conducting the trench depth experiment, it was confirmed that the breakdown voltage was the highest at 6 ㎛, and the on-state voltage drop was the lowest at 3.5 ㎛. In the separate gate width experiment, it was confirmed that the breakdown voltage decreased as the variable increased, and the on-state voltage drop increased. Therefore, it may be seen that it is preferable not to change the width of the separate gate. In addition, experiments show that there is no difference in on-state voltage drop compared to a structure in which a general field stop structure has a separate gate structure. In other words, it is determined that adding a dummy gate with a separate gate structure to the active cell will significantly improve the on-voltage drop characteristics, while confirming that the on-voltage drop does not change, and while having excellent characteristics in terms of breakdown voltage.

A study on the A.C. breakdown characteristics of cross-linked polyethylene dielectrics subjected to the impulse fatigue (충격피로를 받은 가교폴리에틸렌 유전체의 교류절연파괴 특성에 관한 연구)

  • 곽영순;손제봉
    • 전기의세계
    • /
    • v.29 no.9
    • /
    • pp.577-583
    • /
    • 1980
  • This paper is intended to analyze the characteristics of breakdown of polyethylene dielectrics, which was caused by A.C. voltage after impulse fatigue, by using weibull distribution. The impact of impulse fatigue upon the accurance and development of tree and the impact of void upon treeing are investigated. From the results of experiment, it is found that the life of polyethylene subjected to impulse voltage is shorter than that not subjected to impulse voltage. And in the case of void existence, it's life comes to be short remarkably, and the breakdown is almost concentrated on its initiation. From the results observed by the microscope, it is found that the treeing phenomena varies according as whether impulse voltage was applied to polyethylene before being applied to A.C. voltage and whether polyethylene has void or not.

  • PDF

A Study on the Characteristics of ELB Insulating Material deteriorated by Salt water (염수에 의해 열화된 누전차단기 절연재료의 특성에 관한 연구)

  • Kim, Hyung-Rae;Kim, Dong-Ook;Kim, Hyeog-Soo;Choi, Chung-Seog;Kim, Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.878-881
    • /
    • 2001
  • In this paper, we analyzed the characteristics of insulating material with ELB(earth leakage circuit breaker) through tracking experiment and the study was carried out three different types of samples. The tracking is breakdown phenomenon of material surface that is generated on the organic insulating material. The test method applied IEC publication 587. The result of the sample breakdown by tracking was carbonized and resistance of between the electrodes is approximately 300$\Omega$. In the result of DSC analysis, the caloric peak was detected before 100$^{\circ}C$ in product of tracking. It appeared weight loss of 10.87% at 537$^{\circ}C$ on TGA. IR spectrum analysis showed carbon-hydrogen(C-H)bond on molecular structure that is the sample of tracking.

  • PDF

A THEORETICAL STUDY ON BREAKDOWN VOLTAGES IN $SF_6$ AND $N_2$ ($SF_6$$N_2$ 에서의 절연 파괴 전압에 대한 이론적 고찰)

  • 백용현;구본재;송기동;전덕규;이국중
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1989.06a
    • /
    • pp.40-42
    • /
    • 1989
  • In this paper, the theoritical breakdown characteristics of $N_2$and $SF_{6}$ in uniform field are studied by streamer criterion and the effective ionisation coefficients. Evaluation of the breakdown voltage for $N_2$and $SF_{6}$ has been done over following ranges: $N_2$: 100.0 $\leq$pd$\leq$10000.0(Torr cm) $SF_{6}$: 100.0$\leq$pd$\leq$6000.0(Torr cm) Computed values are compared with those of experiment. The results show a good agreement between the computed and the experimental values.

  • PDF

Analysis of The Electrical Characteristics of Power IGBT According to Design and Process Parameter (설계 및 공정 변수에 따른 600 V급 IGBT의 전기적 특성 분석)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.263-267
    • /
    • 2016
  • In this paper, we analyzed the electrical characteristics of NPT planar and trench gate IGBT after designing these devices according to design and process parameter. To begin with, we have designed NPT planar gate IGBT and carried out simulation with T-CAD. Therefore, we extracted design and process parameter and obtained optimal electrical characteristics. The breakdown voltage was 724 V and The on state voltage drop was 1.746 V. The next was carried out optimal design of trench gate power IGBT. We did this research by same drift thickness and resistivity of planar gate power IGBT. As a result of experiment, we obtain 720 V breakdown voltage, 1.32 V on state voltage drop and 4.077 V threshold voltage. These results were improved performance and fabrication of trench gate power IGBT and planar gate Power IGBT.

Effects of Temperature on Dielectric Breakdown Strength of Epoxy Compounds Filled with Natural Zecolite

  • Kim, You-Jeong;Park, Hyeong-Ki;Kim, Sang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.544-547
    • /
    • 1999
  • To develop the better insulants. the zeolite particle, which is aluminosilicate mineral, was filled In the DGEBA/MDA/SN epoxy resin system. Dynamic DSC curves of cured specimens with various contents of zeolite were observed and the glass transition temperature(T$_{g}$) was obtained. According to this result, we could carry out the experiment concerned with the dielectric breakdown strength around T$_{g}$ and find the limit temperature for the application of the DDEBA/MDA/SN system filled with natural zeolite. T$_{g}$ increased with the content of zeolite. As the temperature increased, the dielectric breakdown strength decreased rapidly, in the region of T$_{g}$. At the high temperature, the deterioration by electrical stress was activated. The diameter of puncture at the high temperature was larger 7han that at the room temperature.erature.

  • PDF

Electrical Properties of Liquid Insulation as a Function of Temperature (온도에 따른 액체 절연유의 전기적 특성 )

  • Tae-Hee Kim;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.280-285
    • /
    • 2024
  • In this paper, the electrical properties of liquid insulating oil were analyzed by changing the ambient temperature change at 10℃ in-tervals from 0℃ to 30℃ through an insulation breakdown experiment in order to analyze the insulation performance of liquid in-sulating oil that varies according to temperature changes. As a result, it was confirmed through experiments that the lower the am-bient temperature, the higher the insulation breakdown voltage, depending on both the electrode shape and the electrode interval, and it was determined that the lower the ambient temperature, the higher the insulation performance of the liquid insulating oil.

Varietal Variations in Physicochemical Characteristics and Amylopectin Structure of Grain in Glutinous Rice

  • Choi, Hae-Chune;Hong, Ha-Cheol;Kim, Yeon-Gyu;Nahm, Baek-Hie
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.3
    • /
    • pp.207-213
    • /
    • 1999
  • Thirty-eight glutinous rice varieties were classified into nine groups on the scatter diagram by the upper two principal components (56% contribution to the total information) based on eleven physicochemical characteristics including the viscograms and physical properties of cooked rice. The first principal component was the factor mainly associated with the viscogram characteristics of rice flour emulsion and the second was the factor chiefly related to the physical properties of cooked rice and water absorbability of rice grain. Indica glutinous rices were clearly distinguished from japonica ones by the first principal component score. Javanica glutinous rices were widely distributed on the intermediate zone between indica and japonica or on several japonica rice groups. Significant positive or negative correlations were found among water absorption rates of rice grain, physical properties of cooked rice, and viscogram characteristics of rice flour. Especially in japonica glutinous rices, the breakdown and setback viscosities of rice flour were closely associated with the alkali digestion value of milled rice and the stickiness of cooked rice. The frequency ratio of short glucose chains (A-chain) to intermediate glucose chains (B-chain), the ratio of B- chains to long glucose chains (C-chain) and the relative frequency of A- or B-chain fractions representing the amylopection structure of rice starch was closely associated with the breakdown and setback viscosities of rice flour.

  • PDF