• Title/Summary/Keyword: Breakdown experiment

Search Result 199, Processing Time 0.026 seconds

Effects of Lime and Borax on the Abscission of Tobacco Green Leaves, Yields and Quality (석회.붕사의 시용이 담배의 엽탈락과 수량, 품질에 미치는 영향)

  • 민영근;반유선;이정덕
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.26 no.1
    • /
    • pp.103-109
    • /
    • 1981
  • This experiment was carried out to study the influence on the abscission of tobacco green leaves, yields and quality by the application of lime and boras. The results obtained are as follows; 1. The breakdown of tobacco green leaves occurred from 40 to 80 days after transplanting. According to the progress of growing stage, the breakdown leaves advanced to upper leaves in stalk position. 2. The number of breakdown leaves were increased by application of lime and application of borax have a remarkable effect for the control of breakdown leaves. 3. Application of lime were decreased to total-sugar, lignin and borone but borax were increased to borone and lignin content in leaf tobacco at 50 days after transplanting time. 4. It was found that perfective prevention of breakdown leaves could not deped on annual application of borax. 5. The optimum amount of lime and borax were found that lime was 120kg/10a and borax was 1.2kg/10a for the prevention of breakdown leaves, yields and quality.

  • PDF

characteristic of breakdown voltage of electrode material in vacuum (진공에서 전극 재질에 따른 절연파괴 전압 특성 파악)

  • Lee, Seung-Su;Her, June;Yoon, Jae-Hun;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.101-102
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm. The pressure of vacuum the range of 10^-4${\sim}$10^-5torr. The diameter of a plane made of the stainless steel is 150mm. As a result of the experiment, the breakdown voltage is increased about degree of vacuum increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

Electrical properties of insulating oils for automobile ignition coil (자동차 점화코일용 절연유의 전기적 특성)

  • 신종열;홍진웅
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.172-177
    • /
    • 1999
  • In this paper, the physical and electrical properties of the synthetic fluids No. 2 class Ⅶ used the insulating oils for automobile ignition coil are studied. Also, benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of physical and electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown and the changes of conductivity by measuring volume resistivity are analyzed. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown and volume resistivity test.

  • PDF

Accurate Prediction Method of Breakdown Voltage in Air at Atmospheric Pressure

  • Kim, Nam-Kyung;Lee, Se-Hee;Georghiou, G.E.;Kim, Dong-Wook;Kim, Dong-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.97-102
    • /
    • 2012
  • To predict accurately the breakdown voltage in air at atmospheric pressure, a fully coupled finite element analysis combining the hydrodynamic diffusion-drift equations with Poisson's equation is proposed in the current paper. As three kinds of charged transport particles are nonlinearly coupled with spatial electric fields, the equations should be solved by an iterative numerical scheme, in which secondary effects, such as photoemission and photoionization, are considered. The proposed method has been successfully applied to evaluate the breakdown voltage in circular parallel-plane electrodes. Its validity has been proved through the comparison of the predicted and experimental results. The effects of numerical conditions of the initial charge, photoemission, and background ionization on the discharge phenomena are quantitatively assessed through Taguchi's design of experiment method.

Analysis of Dielectric Breakdown of Hot SF6 Gas in a Gas Circuit Breaker

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Song, Ki-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.264-269
    • /
    • 2010
  • This paper presents the analysis of the dielectric characteristics of a hot $SF_6$ gas in a gas circuit breaker. Hot gas flow is analyzed using the FVFLIC method considering the moving boundary, material properties of real $SF_6$ gas, and arc plasma. In the arc model, the re-absorption of the emitted radiation is approximated with the boundary source layer where the re-absorbed radiation energy is input as an energy source term in the energy conservation equation. The breakdown criterion of a hot gas is predicted using the critical electric field as a function of temperature and pressure. To validate the simulation method, breakdown voltage for a 145kV 40kA circuit breaker was measured for various conditions. Consistent results between the simulation and experiment were confirmed.

A study on the effect of additives in insulating oil under uniform electric field (평등전계중의 절연유에 미치는 첨가물의 영향)

  • 국상훈
    • 전기의세계
    • /
    • v.30 no.6
    • /
    • pp.357-365
    • /
    • 1981
  • When electronegative gas SF$_{6}$ is dissolved and charged with insulating oil, the effect caused in the process by electronegative characteristic is studied and also the pressure effect caused by electronegative SF$_{6}$ acting on the liquid-level is examined respectively. When inert gas Ar is used to find a pressure effect acting on the liquid-level, its effect on dielectric strength is considered in the experiment. With three kinds of impulse voltage different in the duration of wave front and wave tail, a brief experiment if carried out ot see the effects on the dielectric breakdown characteristic as the wave is changing; either if I$_{2}$ and SF$_{6}$ are added to the insulating oil, or if the oil pressure is increased by Ar the dielectric strength becomes great and the longer the duration of wave front is, the greater the increase of the breakdown voltage, because I$_{2}$ added by a small quantity brings about some hirderance in the formation of gas phase. Likewise, the greater the changed pressure is, the greater the incerase of the breakdown voltage. When SF$_{6}$ is charged, the electronegative characteristic is prevailing at the time of low balanced pressure, and the pressure effect at the time of high balanced pressure.ressure.

  • PDF

Characteristics on the Breakdown and Frequency Spectrum of High Power Microwave Pulse Propagating through the Atmosphere (고출력 마이크로파 펄스의 대기권 전파시 방전 및 주파수 스펙트럼에 관한 특성)

  • Kim, Yeong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.8
    • /
    • pp.591-597
    • /
    • 1999
  • The propagation characteristics of high power microwave pulse in an air-breakdown environment are examined. The maximum electron density produced by microwave air-breakdown is limited to $10^6cm^{-3}$ by the tail-erosion effect. Inorder to increase the electron density, the scheme using two pulses intersecting at a desired height is considered. Increasing the carrier frequency, it is shown that microwave pulse can be transferred without the serious erosion in the numerical simulation. This result is useful for the above scheme. Also, an experiment is conducted to show the tail-erosion effect and confirm that a rapidly generated lossy plasma can cause spectral breaking and frequency shift of a high-power microwave pulse. The experimental results are presented by comparing the frequency spectrum of an incident pulse with that of the pulse transmitted through a self-induced air-breakdown environment. The experimental results show that the amount of frequency upshift is co-related with the ionization rate, whereas that of frequency downshift is correlated with the energy losses from the pulse in the self-generated plasma.

  • PDF

Breakdown Characteristics of SF6 in Different State and Bubble Movements under AC High-Voltage

  • Choi, Eun-Hyeok;Lim, Chang-Ho;Yoon, Dae-Hee;Park, Kwang-Seo;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.257-262
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics by temperature change of $SF_6$ gas($GSF_6$), and $SF_6$ liquid ($LSF_6$) in model GIS (Gas Insulated Switchgear) are described. From the experiment's results, the breakdown characteristics classify the vapor stage of $SF_6$ according to Paschen's law, in which the gas & liquid coexisted stage of voltage value increases, resulting in much deviation and the breakdown of voltage ($V_B$) low stage as the interior of the chamber gets filled with a mixture of $SF_6$ that is not liquefacted and remaining air that cannot be ventilated. The ability of $LSF_6$ insulation is higher than the high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubbles caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery that will be studied and developed in the future.

A Study on Phenomena of Watertree and Dielectric Breakdown in XLPE (XLPE의 수트리와 절연파괴 현상에 관한 연구)

  • 이성일
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.4
    • /
    • pp.45-52
    • /
    • 2001
  • In order to Investigate water tree degradation behavior on XLPE cable, direct voltage of 200 to 800V has been applied to the material at 5$0^{\circ}C$~10$0^{\circ}C$, and the water tree property has been correlated with voltage and temperature. The leakage current was increase as temperature increased and the Ohm's law was generally satisfied in this experiment though some experimental errors were found. The leakage current was decreased and reached to the stable state with time. It was also shown that the time for the stabilization of leakage current was lessened as voltage increased

  • PDF

An Experimental Study on the Fire Hazard of Electric Heating Pad (전기장판의 화재위험성 실험연구)

  • Lee, Bok-Young;Park, Chan-Ho;Park, Sang-Tae;Hong, Sung-Ho;Yu, Hyun-Jong
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.113-117
    • /
    • 2006
  • This study presents analysis of fire hazard of electrical heating pad. In order to analyze fire hazard fire experimental and flammability experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition such as breakdown of thermostat. Vertical burning test(UL 94) is conducted for the fire retardant experiment. Kinds of electric heating pad used for experiment are electric mat, fabric pad, vinyl pad. The results show that fire hazard is high in case of breakdown of thermostat with the rating voltage supply. And Material of electric heating pad has not fire retardant performance.