• Title/Summary/Keyword: Breakdown experiment

Search Result 199, Processing Time 0.062 seconds

The Effect of Antistatic Agent for Streaming Electrification on the Breakdown Characteristics of Synthetic Fluids (합성절연유의 절연파괴 특성에 미치는 유동대전 억제제의 영향)

  • Song, Byung-Gi;Lee, Soo-Won;Shin, Jong-Yeol;Shin, Hyun-Teak;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1414-1416
    • /
    • 1997
  • The electrical breakdown characteristics of the synthetic fluids No.2 of KS class VII used for insulating and cooling the materials for the ignition coil are studied. Also, Benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown are analyzed. The breakdown strength of specimen by adding BTA is higher than virgin specimen in low e region, but lower than that in high region because of melting BTA. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown.

  • PDF

Study on 3.3 kV Super Junction Field Stop IGBT According to Design and Process Parameters (설계 및 공정 파라미터에 따른 3.3 kV급 Super Junction FS-IGBT에 관한 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.210-213
    • /
    • 2017
  • In this paper, we analyzed the structural design and electrical characteristics of a 3.3 kV super junction FS IGBT as a next generation power device. The device parameters were extracted by design and process simulation. To obtain optimal breakdown voltage, we researched the breakdown characteristics. Initially, we confirmed that the breakdown voltage decreased as trench depth increased. We analyzed the breakdown voltage according to p pillar dose. As a result of the experiment, we confirmed that the breakdown voltage increased as p pillar dose increased. To obtain more than 3.3 kV, the p pillar dose was $5{\times}10^{13}cm^{-2}$, and the epi layer resistance was $140{\Omega}$. We extracted design and process parameters considering the on state voltage drop.

Correlation Coefficient of Leaf Breakdown with Some Agronomic Characters in Flue- Cured Tobacco (Nicotiana tabacum L.) (황색종 연초(Nicotiana tabacum L.)에서 엽탈락과 농경적 형질과의 상관)

  • 조수헌;진정의
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.11 no.2
    • /
    • pp.149-155
    • /
    • 1989
  • This study was conducted to obtain the breeding information for the leaf breakdown, and correlation coefficients between leaf breakdown and some agronomic characters in flue-cured tobacco at Taegu Experiment Station, Korea Ginseng & Tobacco Research Institute. NC 95 and NC 2326 were used as parents. The bulk method procedure was used from the F2 to the F4 generations, 54 plants were selected among F4, and 11 lines were selected among 54 F5 which based on high resistance to bacterial wilt compared with NC2326. The entries were composed of parents and 11 F6 advanced lines, and designed in randomized block with 3 replications. Plant seedlings were transplanted in 16 April. The number of breakdown leaf were investigated at flowering stage, 18 June. There were significant difference between NC 95 and NC 2326 for the number of breakdown leaf, number and weight of ground suckers, days to flower, yield and resistance to bacterial wilt, and similar results were appeared among lines. Estimated heritability in the broad-sense ranged from 59.3% to 87.4% for all characters. Most of genetic correlations were higher than phenotypic coefficients between characters. Number of breakdown leaf was positively correlated with days to flower, the number and weight of ground suckers, while it was negative to yield. One line among 11 had few breakdown leaf, low producted ground suckers and high resistance to bacterial wilt. Above results suggest that the number and weight of ground suckers can be use as a selection criterion for leaf breakdown even under the condition without leaf breakdown.

  • PDF

Electrical Characteristics on the Interface between XLPE/EPDM (XLPE/EPOM 계면의 전기적 특성)

  • 한성구;조정형;이창종;김종석;서광석;박대희;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.235-238
    • /
    • 1996
  • In this paper, We intended to evaluate the characteristics of XLPE/EPDM interface which exists in the cable joint. The fault was mainly occurred in this interface. Thus we looked into the electrical characteristics through the conduction current and the breakdown test. Through from the experiment, we obtained the result that the conduction current in this interface flowed less than other dielectric materials, that the breakdown strength was higher and that the pressure dependance ㅐf the breakdown strength was higher.

  • PDF

Electrical breakdown properties in neon gas mixed with xenon

  • Han S. Uhm;Park, Eun H.;Guansup Cho;Ki W. Whang
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.4 no.4
    • /
    • pp.112-121
    • /
    • 2000
  • The paper investigates electrical discharge properties in neon gas mixed with xenon. The breakdown temperature T$\sub$b/ and voltage V$\sub$b/ are obtained in terms of the gas mixture ratio X. It is shown that the breakdown voltage decreases, reaches the minimum value at X=0.02 and then increases again, as the mixture ratio X increases from zero to unity. Therefore, mixing the neon gas with a few percent of xenon is the most beneficial to reduce the breakdown voltage. Plasma density at breakdown in neon gas mixed with xenon is described in terms of the gas mixture ratio. The optimum value of mixture ratio for highest plasma density is found to be Xm=0.03. A preliminary experiment of AC-PDP is carried out for neon gas mixed with a few percent of xenon to verify some of the theoretical models. The experimental data agree qualitatively well with theoretical predictions.

  • PDF

Electrical AC Insulation Breakdown Characteristics of Various Epoxy / Heterogeneous Inorganic Mixed Composite (여러 종류의 에폭시/이종무기물 혼합 콤포지트의 전기적 교류 절연파괴 특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1463-1470
    • /
    • 2018
  • In this study, 20 types of samples were prepared by mixing different kinds of inorganic materials to develop insulation materials for epoxy - based GIS substation equipment used under high voltage environmentally friendly insulation gas. One of the electrical characteristics, AC insulation breakdown experiment was performed. As mixing ratio of mixed heterogeneous inorganic materials, the dielectric breakdown strength was increased with increasing filler ratio of micro silica, micro silica : micro Alumina, 1:9, 3:7, 5:5, 7:3, 9:1, and decreased as the filling amount of micro alumina increased. The AC insulation breakdown characteristics were the best when the composition ratio was 9:1. The higher the content of silica, the better the interfacial properties, and the larger the alumina content ratio, the worse the interfacial properties.

Comparision Study Between Modeling and Experiment of the Breakdown Voltage for AC Plasma Display Panel (AC 플라즈마 디스플레이패널의 방전개시전압에 모델과 실험의 비교에 관한 연구)

  • 박장식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1039-1044
    • /
    • 2000
  • Breakdown voltage model and expertiments are compared for discharge cells of AC plasma display panel. In the model, discharge paths are assumed to be initial electric field lines and the one-dimensional continuity equation is applied to the charged particle transport at each field line. The comparisons are performed in the wide range of gas pressure (50-600torr), Xe partial pressure over total pressure (1-6%), sustain electrode gap(100-1000$\mu\textrm{m}$), wall height(130, 300$\mu\textrm{m}$), and voltage pulse width(2-6${\mu}$s). The presented breakdown voltage model well agree with experiments in the above wide range. The increase of breakdown voltage with the decrease of the width(L) of protruding electrode is also described by the model.

  • PDF

Electric Field Analysis with Imaginary Streamer Process and Insulation Characteristics on the Ribbed Spacer for GIS (GIS 립 스페이서의 가상스트리머 진전에 따른 전계해석 및 절연특성)

  • Ryu, Sung-Sic;Choi, Young-Chan;Lee, Chang-Ryong;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1649-1651
    • /
    • 2001
  • The effect of ribbed spacers having metallic particle attached to the post-type spacer on dielectric breakdown phenomena has been investigated using electric field analysis for imaginary streamer process and a breakdown experiment. It was described that the electric field analysis and the dielectric breakdown test were performed on the case that the particle was attached to the various position of the ribbed spacer having various shapes. As a result, the breakdown voltage of the spacer with two ribs was highest, and it was varied by the length and the thickness of the rib. Especially, in case of the rib with round edge, the breakdown voltage was higher than that with rectangular edge, which complied with the result through the field analysis.

  • PDF

characteristic of breakdown voltage of electrode gap in vacuum (진공에서 극간 gap에 따른 절연파괴 전압 특성 파악)

  • Yoon, Jae-Hun;Kim, Byung-Chul;Lee, Sueng-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm, 0.8mm. The pressure of vacuum the range of 10^-4-10^-5torr. The diameter of a plane made of the stainless steel is150mm. As a result of the experiment, the breakdown voltage is increased about electrode gap distance increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

Analysis of the Three-Dimentional Effects on the Breakdown Voltage in Non-reachthrough Planar Junctions (Non-reachthrough 평면 접합의 항복전압에 대한 3 차원 효과의 해석)

  • 김성동;김일중;최연익;한민구
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.111-118
    • /
    • 1995
  • The three-dimentional effects on the breakdown voltage of non-reachthrough planar junctions which have the finite lateral radius of window curvature are analytically investigated. The critical electric fields at breakdown and the breakdown voltages are expressed successfully in a form which is normalized to the parallel plane case. The analytical results are in excellent agreement with the published results of experiment and the quasi-three-dimensional device simulation by MEDICI for non-reachthrough plane junctions having different background doping and junction depth. The results may be applicable to the estimations of breakdown voltages in many practical power devices.

  • PDF