• Title/Summary/Keyword: Break-In

Search Result 3,247, Processing Time 0.029 seconds

Condition Monitoring for Coil Break Using Features of Stationary Rolling Region (정상 압연 구간의 특징을 이용한 판 파단의 상태감시)

  • Oh, J.S.;Yang, S.W.;Shim, M.C.;Caesarendra, W.;Yang, B.S.;Lee, W.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1252-1259
    • /
    • 2009
  • Due to the international competition and global pressure, the roll speed is increased. However, higher speeds increase the power density in the process as well as the plant's potential to react with vibrations. Under certain operating conditions, vibrations may occur, which again cause chattermarks, strip rupture or coil break fault. The appropriate condition monitoring is needed to improve product quality and availability. The aim of condition monitoring is to reduce maintenance costs, increase productivity and improve product quality. This paper proposes a condition monitoring tool designed for the classification of coil break fault. This method is used to cold rolling mill for faults monitoring based on vibration and motor current signals. The results show that the performance of classification has high accuracy based on experimental work.

The Relativity between Vibration of Phantom and Its Break Efficiency Due to Position of Focus Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter (압전식 충격파 체외 쇄석기 사용시 초점위치에 의한 대상물의 진동과 파쇄효율과의 상관성)

  • 장윤석
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.35-40
    • /
    • 2000
  • In this paper, the relation between the radiated sound and the vibration due to piezoelectric ESWL(Extracorporeal Shock Wave Lithotripter) is examined and the results of the experiments are represented. Next, the relation between the focal point and the vibration of the objects is examined. The same experiments with the objects that can be broken are done and the relation between the vibration and the break efficiency of the phantom is experimentally investigated. These results show that the relativity between the power of the peak frequency and the break efficiency can be confirmed.

  • PDF

A Simple Finite Element Modeling Method for Leak-Before-Break Crack Analysis of Pipe with Overlay Dissimilar Metal Weldments (이종금속 오버레이 용접 배관의 파단전누설균열 해석을 위한 단순 유한요소 모델링 방법)

  • Kim, Maan Won;Park, Young Sup
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.70-76
    • /
    • 2013
  • Several finite element models for the leak-before-break (LBB) assessment of overlay dissimilar metal weldment were constructed and analyzed to develop a simple finite element modeling method. The J-integral, crack opening displacement (COD) and J-integral distribution along the crack front in thickness direction due to the applied moment were obtained from the analysis results of the constructed finite element models, and studied compared to the previous literatures. It is concluded that the modeling with base material only is simple and produces a slightly conservative results compared to the complex modeling composed with weld metal and base metal in the calculation of J-integrals and COD values which are used for the calculation of fracture toughness and postulated leakage crack length respectively.

Numerical Simulation of Dam Break Flow using EFDC Model and Parameter Sensitivity Analysis (EFDC 모형을 이용한 댐 붕괴류 수치모의 및 매개변수 민감도 분석)

  • Jang, Chul;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.143-149
    • /
    • 2016
  • In this study, a series of numerical simulation of dam break flow was conducted using EFDC model, and input conditions including cell size, time step, and turbulent eddy viscosity were considered to analyze parameter sensitivity. In case of coarse mesh layout, the propagated length of the shock wave front was ${\Delta}_x$ longer than that of other mesh layouts, and the velocity results showed jagged edge, which can be cured by applying fine grid mesh. Turbulent eddy viscosity influenced magnitude of the maximum velocity passing through gate up to 20% and the cell Peclet number less than 2.0 ensured no numerical oscillations.

Determination of Optimal Time to Replace On-S Water Pipeline by Analyzing Water Main Failures and Economical Efficiency (수도사고 분석 및 경제성 평가를 통한 상수관로 최적 교체시기 결정)

  • Kim, Jong-Sin;Jung, Kwan-Sue;Bae, Chul-Ho;Lee, Doo-jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.279-285
    • /
    • 2009
  • In this study, applied to the industrial water service, it is verified feasibility of break-even analysis method which has not been introduced in Korea. The On-san water pipeline of 7.1km among the Ul-san industrial water service is selected and the optimal replacement time calculated by break-even analysis method is year 2033 to 2044 which will be 53 to 67 years since the pipes were buried. If indirect cost such as the value of lost water and traffic disruption, service interruption, etc. is calculated as 30 and 100% of the direct cost, the financially optimum replacement time is advanced 3 to 9 years. These ways present rational criteria to establish long-term plan for budget and to execute the limited budget efficiently.

DEVELOPMENT OF 2D DAM BREAK FLOW ANALYSIS MODEL USING FRACTIONAL STEP METHOD

  • Kim, Dae-hong;Kim, Woo-gu;Chae, Hyo-sok;Park, Sang-geun
    • Water Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.23-30
    • /
    • 2002
  • A numerical model for the solution of two-dimensional dam break problems using fractional step method is developed on unstructured grid. The model is based on second-order Weighted Averaged Flux(WAF) scheme with HLLC approximate Riemann solver. To control the nonphysical oscillations associated with second-order accuracy, TVD scheme with SUPERBEE limiter is used. The developed model is verified by comparing the computational solutions with analytic solutions in idealized test cases. Very good agreements have been achieved in the verifications.

  • PDF

Evidence of Outbreak in 2000m of water Mass in the Kuroshio Extension (일본 동북 연안 쿠로시오 속류 Warm Water Break의 발견)

  • 양찬수
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.423-428
    • /
    • 2004
  • 쿠로시오는 일본열도 동안을 북상하면서, 조오반 앞바다에서 동쪽으로 이동하게 된다. 이 해역에서 오야시오에 기인한 냉수괴의 배치에 따라 쿠로시오의 북상범위 및 유로(여기서는 구불구불한 흐름의 형상)가 크게 바뀌게 된다. 본 연구에서는 쿠로시오 속류가 진행방향과 반대되는 방향으로 짧은 주기를 갖고 발생한 ‘warm water break’ 을 발견하였다. 10일 이하의 주기를 갖는 것으로 추정되는 이 event을 상세히 이해하기 위하여 다음의 자료를 사용하였다. 1) SeaWiFS chlorophyll-a 영상, 2) AVHRR-SST 영상, 3)Topex/poseidon과 ERS-2의 해면고도정보, 4) 관측데이터: ADCP와 수온과 염분의 연직분포. 이 연구결과를 통해, 쿠로시오의 이벤트 ‘warm water break’을 확인하였으며, 이 현상은 10일 이하의 짧은 주기를 갖고 수심 2000m 정도까지 영향을 미치는 것으로 판단되었다.

  • PDF

Reliability for SF6 gas load break switch of distribution system (배전선로용 가스절연부하개폐기의 신뢰성 향상책)

  • Park, Seung-Jae;Heo, Jong-Chul;Shin, Young-June;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.452-454
    • /
    • 2003
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability. Accordingly, this paper presents the reliability testing method for $SF_6$ gas load break switch which is based on the analysis of the failure mode and the statistics.

  • PDF

Ultransonic Effect on the Break-Down Characteristics of Liquid Dielectrics (액체유도체의 절연특성에 미치는 초음파의 영향)

  • Choon Saing Jhoun;Hong Keun Kim;Bong Sik Hong
    • 전기의세계
    • /
    • v.26 no.4
    • /
    • pp.61-67
    • /
    • 1977
  • This paper treats the Ultrasonic effects on the break down characteristics of Liquid Dielectric Material 1) Relative Dielectric constant, Es of Liquid Dielectric Material at a constant temperature decreases in proportion to the irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 2) Power factor of Liquid Dielectric Material at a constant temperature increases in proportion tothe irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 3) Relative resistance of Liquid Dielectric Material at a constant temperature decrease with the irradiated time of Ultrasonic radiation, but the effect of its intensity is very irregular. 4) Break-down strength of Liquid Dielectric Material, at a constant temperature decreases with the irradiated time of Ultrasonic radiation and its intensity, and then reaches to a saturated value.

  • PDF

The Study Used Brog's Scale on the Lower Extremity Supporter (주관적 작업부하를 이용한 하체 서포터 평가에 관한 연구)

  • Kim, Yu-Chang;Chang, Eon-June
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.105-110
    • /
    • 2008
  • This study focused on the decreased effect of the work load on using the lower extremity supporter in kneeling posture. Fatigue measures included subjective discomfort ratings through the use of the Borg's CR-10 scale based parameters. The resting period and work method were considered as independent variables. The break time conditions are grouped into 10 seconds after work for 1 min and not exist break time. The method of work conditions are divided into four types. There are kneeling with the lower extremity supporter, kneeling with the knee protector, just kneeling and squatting. The result of the ANOVA of the shift value of subjective discomfort showed the followings: 1) There were differences as regards to the method of the work, the break time and the part of body($p{\leq}0.05$). 2) The lower extremity supporter showed the least subjective discomfort in other part of body except the upper leg.