• Title/Summary/Keyword: Branch-line

Search Result 389, Processing Time 0.033 seconds

Flight Model Development of Linearized Channel Amplifier (선형화 채널 증폭기 비행모델 개발)

  • Hong, Sang-Pya;Go, Yeong-Mok;Yang, Ki-Dug;Ra, Keuk-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.3
    • /
    • pp.83-90
    • /
    • 2009
  • This paper presents the design and measurement of a flight model for a Ku-Band Linearized Channel Amplifier. All MMICs, Variable Gain Amplifier (VGA), Variable Voltage Attenuator ('.IVA), Branch line Coupler and Detector for Pre-distorter are fabricated using a Thin-Film Hybrid process. The performance of the fabricated module is verified through the radio frequency circuit simulation tool and electrical function test in space environment.

  • PDF

Ananalzing fault current and Protective coordination in the underground line (지중배전선로의 고장전류 크기 및 보호협조분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

Development of a New Active Phase Shifter

  • Kim, S.J.;N.H. Myung
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.1063-1066
    • /
    • 2000
  • ln this paper, a new active phase shifter is proposed using a vector sum method, and it is shown that the proposed phase shifter is more efficient than the others in size, power, number of circuits, and gain. Also a unique digital phase control method of the circuit is suggested. The proposed scheme was designed and implemented using a Wilkinson power combiner/divider, a branch line 3dB quadrature hybrid coupler and variable gain amplifiers (VGAs) using dual gate FETs (DGFETs). Furthermore, it is also shown that the proposed scheme is more efficient and works properly with the digital phase control method.

  • PDF

A Study on the Monitoring System of Passive Filter to Improve Power Quality (전력품질 개선을 위한 수동필터 모니터 시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, we developed DSP based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100[HP] d.c. motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

  • PDF

Classification and Comparison of EMI Mitigation Techniques in Switching Power Converters - A Review

  • Yazdani, Mohammad Rouhollah;Farzanehfard, Hosein;Faiz, Jawad
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.767-777
    • /
    • 2011
  • Power electronic systems such as switching power supplies are accounted as noise sources for other sensitive circuits. EMI caused by power converters can disturb the normal operation of the converter and other adjacent systems. Major research is concentrated on EMI mitigation for power converters in which the main concern is compliance with EMC standards to ensure proper operation of converters and nearby systems. This paper reviews EMI reduction techniques related to switching power converters with emphasis on the conducted EMI. A comprehensive review of significant research works is performed and various methods are thoroughly discussed and compared. Also, a classification of methods is presented. Moreover, converter prototypes are realized which contain several EMI mitigation techniques and their effects are presented via experimental results.

Emergency Service Restoration Algorithm Considering Service Rank in Distribution System (서비스우선순위를 고려한 긴급정전복구 앨고리즘)

  • Song, Kil-Yeong;So, Min-He;Jeong, Min-Hwa;NamKung, Jae-yong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.800-803
    • /
    • 1996
  • This paper proposes the algorithm to solve emergency service restoration problems using efficient reconfiguration method in distribution system. In this algorithm, we try to avoid the blackout of important loads by considering service rank. It is possible to reconfigurate the system by using fuzzy inference results in which was reflected the expected distribution power, line capacity and service rank. A 27-bus, 32-branch model system is used to demonstrate the effectiveness of the proposed algorithm.

  • PDF

On the Lightning Induced Voltage Along Overhead Power Distribution Line

  • Izadi, Mahdi;Ab Kadir, Mohd Zainal Abidin;Hajikhani, Maryam
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1694-1703
    • /
    • 2014
  • Lightning induced voltage is a major factor that causes interruptions on distribution lines. In this paper, analytical expressions are proposed to evaluate a lightning induced voltage on power lines directly in the time domain without the need to apply any extra conversions. The proposed expressions can consider the widely used current functions and models in contrast to the earlier analytical expressions which had a number of limitations related to the simplification of the channel base current and the current along the lightning channel. The results show that the simulated values based on the proposed method are in good agreement with the previous studies and the proposed expressions can be used for optimizing the insulation and protection level of existing and new lines being designed.

Fabrication and Characterization of $High-T_c$ Superconducting Single Channel Flux Flow Transistor using the Atomic Force Microscope TiO Cantilever Tip (원자힘 주사현미경 TiO 탐침을 이용한 고온 초전도 단일채널 자속 흐름 트랜지스터의 제작 및 특성 해석)

  • Ko, Seok-Cheol;Kang, Hyeong-Gon;Lim, Sung-Hun;Lee, Jong-Hwa;Lee, Hae-Sung;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.101-104
    • /
    • 2004
  • We have fabricated a channel of superconducting flux flow transistor(SFFT) using the voltage-biased atomic force microscope(AFM) TiO tip and performed numerical simulations for the SFFT controlled by the magnetic field with a control current. The critical current density in a channel of the fabricated SFFT was decreased with the applied current by a control line. By comparing the measured with theoretical results, we showed a possibility of fabrication of an SFFT with a nano-channel using AFM anodization process technique.

  • PDF

Miscibility and Properties of cis-Polybutadiene/Ethyl-Branched Polyethylene Blends (II)

  • Cho, Ur-Ryong
    • Macromolecular Research
    • /
    • v.8 no.2
    • /
    • pp.66-72
    • /
    • 2000
  • Cis-Polybutadiene (cis-PBD) and the three polyethylenes (PE's) having different branch content were mixed to investigate crystallinity, thermodynamic interaction parameter(c), and diluents effect. Crys-tallinty of PE's decreased with increasing content of amorphous cis-PBD because of a decrease in both the degree of annealing and kinetics of diffusion of the crystallizable polymer content. The thermodynamic interaction parameter(c) for the three blend systems approximately equals to zero near the melting point. These systems were determined to be miscible on a molecular scale near or above the crystalline melting point of the crystalline PE's. From the measurement of T$\sub$m/ vs. T$\sub$c/ behavior, all the three blends showed a straight line for a plot of T$\sub$m/ vs. T$\sub$c/. This result means that the melting behavior of PE is mainly due to a diluent effect of cis-PBD component.

  • PDF

CARS Spectra of HCI, N₂, and C₂H₂ in the Gas Phase

  • 백선종;김중희;박주연;이성열;김홍래
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.9
    • /
    • pp.810-813
    • /
    • 1995
  • Coherent anti-Stokes Raman scattering (CARS) spectra of HCl, N2, and the ν1 fundamental of C2H2 have been measured in the gas phase. The measured spectra show rotational structures which originate from the Q-branch transitions. The spectra have successfully been simulated with proper selection rules, line positions, and relative intensities from room temperature Boltzmann population distributions. The vibration-rotation interaction constant α of HCl in the ground electronic state has been measured from the rotationally resolved CARS spectra which is α=0.3076 cm-1. Possibilities of optical pumping and of measuring state specific energy distributions of molecules are discussed.