• Title/Summary/Keyword: Brain magnetic resonance imaging (MRI)

Search Result 503, Processing Time 0.024 seconds

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

Acute Ischemic Stroke: Current Management and Role of the Nurse Practitioner

  • Kang, Ji-Yeon;Coleman, Patricia;Kim, Keum-Soon;Yi, Young-Hee;Choi, Eun-Jung
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.1
    • /
    • pp.26-35
    • /
    • 2009
  • Purpose: This paper reviews current diagnostic evaluation, treatment, nursing considerations, and the nurse practitioner’s (NP) role in acute ischemic stroke care. Methods: National guidelines and extensive literature on acute stroke care were reviewed and a relevant clinical case was introduced. Results: Computerized tomography (CT) of the head without contrast is the initial brain imaging procedure for patients with an acute stroke. Magnetic resonance imaging (MRI) can be an alternative test. Restoration of cerebral perfusion to the affected area is a key therapeutic strategy for ischemic stroke. A number of treatment strategies such as thrombolysis, anticoagulation, antiplatelet, and surgical treatment can be selected to improve blood flow to the ischemic region. The NP on the stroke team is involved with immediate stroke management including neurological assessment, ensuring adequate oxygenation, blood pressure management, activity, and diet. Discharge planning with the patient, family teaching and coordination of follow up care should also be implemented early in the hospitalization. Conclusion: The nurse practitioner is one of the cardinal members on the stroke team, and must be updated with current treatment and management guidelines.

  • PDF

Real-Time fMRI-Guided Functional MR Spectroscopy: The Lactate Peaks at the Motor Cortex during Hand-Grasping Tasks (실시간 기능적 자기공명영상 유도 기능적 자기공명분광법: 손운동 수행중 운동피질의 젖산변화 관찰)

  • Choi, Sun-Seob;Oh, Jong-Young;Kang, Myong-Jin;Lee, Jin-Hwa;Yoon, Seong-Kuk;Nam, Kyung-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.33-39
    • /
    • 2008
  • Purpose : There is debate concerning the observation of metabolite changes on MRS at the designated cortex during some tasks. The purpose of this study is to assess the change of the lactate content at the motor cortex during hand-grasping tasks with performing real-time fMRI-guided fMRS. Materials and Methods : Seven healthy volunteers (23-28 years old) underwent realtime fMRI during right hand grasping tasks with using a 1.5 T system. After confirming the activating area, single voxel MRS was preformed at 1) the baseline, 2) during the task and 3) after the task on the activating cortex. The three consecutive spectra were compared for observing the changes of the lactate content by the tasks. The Cho/Cr, NAA/Cr and Lac/Cr ratios were calculated manually from those spectra. Results : MRS during the tasks revealed the lactate peaks at the 1.33 ppm resonance frequency with great conspicuity at the activated area, which was identified on the real-time fMRI. After the task scan, the lactate peaks completely disappeared and the spectra recovered to the values of the baseline scan in all volunteers. At baseline, during the task and after the task, the Cho/Cr ratios were 0.81, 0.76 and 0.77, respectively, and the NAA/Cr ratios were 1.68, 1.65 and 1.72, respectively, and the Lac/Cr ratios were 0.28, 0.41 and 0.30, respectively. During the task, Lac was significantly increased by 46%. Conclusion : We observed prominent lactate peaks on MRS during hand-grasping tasks at the activated area, as was shown on the real-time fMRI. We suggest that fMRS can be used as a sensitive tool for observing the metabolite changes of the functioning brain.

  • PDF

A Study on the Tensor-Valued Median Filter Using the Modified Gradient Descent Method in DT-MRI (확산텐서자기공명영상에서 수정된 기울기강하법을 이용한 텐서 중간값 필터에 관한 연구)

  • Kim, Sung-Hee;Kwon, Ki-Woon;Park, In-Sung;Han, Bong-Soo;Kim, Dong-Youn
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.817-824
    • /
    • 2007
  • Tractography using Diffusion Tensor Magnetic Resonance Imaging (DT-MRI) is a method to determine the architecture of axonal fibers in the central nervous system by computing the direction of the principal eigenvector in the white matter of the brain. However, the fiber tracking methods suffer from the noise included in the diffusion tensor images that affects the determination of the principal eigenvector. As the fiber tracking progresses, the accumulated error creates a large deviation between the calculated fiber and the real fiber. This problem of the DT-MRI tractography is known mathematically as the ill-posed problem which means that tractography is very sensitive to perturbations by noise. To reduce the noise in DT-MRI measurements, a tensor-valued median filter which is reported to be denoising and structure-preserving in fiber tracking, is applied in the tractography. In this paper, we proposed the modified gradient descent method which converges fast and accurately to the optimal tensor-valued median filter by changing the step size. In addition, the performance of the modified gradient descent method is compared with others. We used the synthetic image which consists of 45 degree principal eigenvectors and the corticospinal tract. For the synthetic image, the proposed method achieved 4.66%, 16.66% and 15.08% less error than the conventional gradient descent method for error measures AE, AAE, AFA respectively. For the corticospinal tract, at iteration number ten the proposed method achieved 3.78%, 25.71 % and 11.54% less error than the conventional gradient descent method for error measures AE, AAE, AFA respectively.

Knee Articular Cartilage Segmentation with Priors Based On Gaussian Kernel Level Set Algorithm (사전정보를 이용한 가우시안 커널 레벨 셋 알고리즘 기반 무릎 관절 연골 자기공명영상 분할기법)

  • Ahn, Chunsoo;Bui, Toan;Lee, Yong-Woo;Shin, Jitae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.6
    • /
    • pp.490-496
    • /
    • 2014
  • The thickness of knee joint cartilage causes most diseases of knee. Therefore, an articular cartilage segmentation of knee magnetic resonance imaging (MRI) is required to diagnose a knee diagnosis correctly. In particular, fully automatic segmentation method of knee joint cartilage enables an effective diagnosis of knee disease. In this paper, we analyze a well-known level-set based segmentation method in brain MRI, and apply that method to knee MRI with solving some problems from different image characteristics. The proposed method, a fully automatic segmentation in whole process, enables to process faster than previous semi-automatic segmentation methods. Also it can make a three-dimension visualization which provides a specialist with an assistance for the diagnosis of knee disease. In addition, the proposed method provides more accurate results than the existing methods of articular cartilage segmentation in knee MRI through experiments.

The Correlation of MRI Findings to Outcome in Diffuse Axonal Injury Patients (미만성 뇌축삭손상 환자의 자기공명영상 소견과 예후와의 상관관계)

  • Oh, Kyung Seup;Ha, Sung Il;Suh, Bumn Suk;Lee, Hyun Sung;Lee, Jong Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.20-24
    • /
    • 2001
  • Object : We intended to investigate the relationship between the degree of injury on MRI and the outcome of the patients with diffuse axonal inury. Method : From january, 1995 to march, 1999, 22 patients were supposed to have diffuse axonal injuries by means of their neurologic signs and MRI. We investigated their prognosis according to CT, MRI and initial neurologic findings. Result : 1) The lesions were mainly located at white matter of cerebrum, corpus callosum, brainstem, and basal ganglia. 2) The lesions of white matter were most commonly in the frontal lobe and temporal lobe. 3) The majority of corpus callosal lesions were located in the posterior body and splenium, but anterior corpus callosal lesions combined with posterior lesions were not found. 4) Brainstem lesions, all non-hemorrhagic, were mostly located in the dorsolateral aspect, not be found on CT. 5) The brainstem lesions were found in 10 cases among total 22 cases, and corpus callosal lesions were accompanied with 8 cases of brainstem lesions. 6) The patients with brainstem lesions had worse prognosis. Conclusion : It is important and reasonable to take brain MRI to identify the brainstem lesions in any cases of suspicious diffuse axonal injury, and we should remind that the diffuse axonal injury with stem lesion has worse prognosis.

  • PDF

Magnetic resonance imagining findings of the white matter abnormalities in the brain of very-low-birth-weight infants (극소 저체중 출생아에서 뇌백질 병변의 MRI 소견)

  • Choi, Jae Hyuk;Chang, Young Pyo
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1127-1135
    • /
    • 2009
  • Purpose : To observe the abnormal white matter findings on the magnetic resonance imaging (MRI) scans of very-low- birth-weight (VLBW) infant brains at term-equivalent age and to determine the clinical risk factors for the development of periventricular leukomalacia (PVL). Methods : In all, MRI was performed in 98 VLBW infants and the white matter abnormalities were observed. Clinical risk factors for cystic and noncystic PVL were determined. Results : MRI scans of 74 infants (75.5%) showed diffuse excessive high signal intensity (DEHSI) in the periventricular white matter, 17 (17.3%) lateral ventricle dilation, 5 (5.1%) and 11 (11.2%) focal punctate lesions and cystic changes in the periventricular white matter, respectively, 9 (9.1%), germinal layer hemorrhage (GLH) or subependymal cysts 3 (3.1%) intraventricular hemorrhage (>grade 2) 2 (2.0%) posthemorrhagic hydrocephalus and 2 (2.0%) periventricular hemorrhagic infarct. Gestational age (GA), 1-minute Apgar score, Clinical Risk Index for Babies-II (CRIB-II) score, and inotrope use, and GA, CRIB-II score, postnatal steroid administration, inotrope use, and abnormal white blood cell (WBC) count at admission were related to cystic PVL and noncystic PVL development, respectively (P<0.05). However, in logistic regression analysis, CRIB-II (odds ratio, 1.63, 295% confidence interval, 1.15-2.30 P=0.006) for cystic PVL, and GA (odds ratio 0.90, 95% confidence interval, 0.82-0.99 P=0.036) for noncystic PVL were only significant independently. Conclusion : White matter abnormalities could be observed on MRI scans of the VLBW infant brains at term-equivalent age, and CRIB-II and GA were only independently significant for cystic and noncystic PVL development, respectively.

A case of hippocampal sclerosis diagnosed as cortical dysplasia due to preoperative brain MRI finding (수술 전 뇌 자기공명 영상에서 겉질 형성이상증 소견 보였으나 수술 후 병리학적으로 확인된 해마경화증 1례)

  • Lee, Jun Seok;Kim, Kyo Ryung;Kim, Jeong Tae;Choi, Min Jung;Lee, Young Mock;Kim, Heung Dong;Lee, Joon Soo;Kim, Dong Seok;Kim, Tae Seong
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.106-110
    • /
    • 2010
  • Hippocampal sclerosis (HS) is one of the most common features of intractable temporal lobe epilepsy. Generally it can be identified through brain magnetic resonance imaging (MRI) with high degree of sensitivity and specificity. Typical brain MRI findings of HS are hippocampal atrophy with hyperintense signal confined to the lesion. On the other hand cortical dysplasia exhibits blurring of the gray-white matter junction and abnormal white matter signal intensity. We present a case where preoperative brain MRI strongly suggested the presence of diffuse cortical dysplasia in the left temporal lobe but postoperative pathology revealed the temporal lesion to be unremarkable except for hippocampal sclerosis.

A study on Brain activity induced by electro-acupuncture on Taechung(LR3) and Hapkok(LI4) using functional Magnetic Resonance Imaging (태충(太衝)(LR3).합곡(合谷)(LI4) 전침자극(電鍼刺戟)이 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響) - fMRI를 이용(利用)한 연구(硏究) -)

  • Park, Tae-Gyoon;Kim, Young-Il;Hong, Kwon-Eui;Yim, Yun-Kyoung;Lee, Hyun;Lee, Byung-Ryul
    • Korean Journal of Acupuncture
    • /
    • v.21 no.2
    • /
    • pp.29-46
    • /
    • 2004
  • Objectives and Methods : This study was performed to investigate the effect of electro -acupuncture at four gates(bilateral LR3 and LI4) on brain activity in normal subjects using fMRI. Results and Conclusions : 1. fMRI signal increase by electro-acupuncture at Lt. LR3 was observed in Rt. Middle frontal gyrus in group average as well as more than half of the subjects. 2. fMRI signal decreases by electro-acupuncture at Lt. LR3 were observed in Rt. Superior frontal gyrus, Rt. Middle temporal gyrus, Rt. Cingulate gyrus in group average as well as more than half of the subjects. 3. fMRI signal increases by electro-acupuncture at Lt. LI4 were observed in Lt. Superior frontal gyrus, Lt. Middle frontal gyrus, Lt. Inf. Semi-Lunar Lobule(cerebellum), Rt. Middle frontal gyrus, Rt. Cingulate gyrus in group average as well as more than half of the subjects. 4. fMRI signal decreases by electro-acupuncture at Lt. LI4 were observed in Lt. Middle frontal gyrus, Lt. Inferior frontal gyrus, Lt. Precentral gyrus and Rt. Middle frontal gyrus, Rt. Middle temporal gyrus, Rt. Precuneus, Rt. Inferior frontal gyrus, Rt. Postcentral gyrus in group average as well as more than half of the subjects. 5. fMRI signal increase by electro-acupuncture at Lt. LR3 and Lt. LI4 in group average as well as more than half of the subjects was not observed. 6. fMRI signal decreases by electro-acupuncture at Lt. LR3 and Lt. LI4 were observed in Lt. culmen(cerebellum), Lt. Cingulate gyrus와 Rt. Middle frontal gyrus, Rt. Cingulate gyrus, Rt. Inferior frontal gyrus in group average as well as more than half of the subjects. 7. fMRI signal increases by electro-acupuncture at four gates (bilateral LR3 and LI4) were observed in Lt. Middle temporal gyrus and Lt. Postcentral gyrus in group average as well as more than half of the subjects. 8. fMRI signal decrease by electro-acupuncture at four gates (bilateral LR3 and LI4) were observed in Lt. Middle frontal gyrus, Lt. Precentral gyrus, Lt. Inferior frontal gyrus, Lt. Middle temporal gyrus, Lt. Frontal sub-gyral and Rt. Tuber(cerebellum) in group average as well as more than half of the subjects.

  • PDF