• Title/Summary/Keyword: Bragg peak

Search Result 110, Processing Time 0.022 seconds

Spectrum Characteristics and Stress Induced Birefringence of Fiber Bragg Grating Embedded into Composite Laminates (복합재 평판에 삽입된 광섬유 브래그 격자의 스펙트럼특성과 응력유도복굴절)

  • Lee, Jung-Ryul;Kim, Chun-Gon;Hong, Chang-Sun
    • Composites Research
    • /
    • v.15 no.3
    • /
    • pp.30-38
    • /
    • 2002
  • Fiber Bragg grating(FBG) like other optical fiber sensors also has the merit of embedding capability. To increase their actual value related to embedding capability, this paper reported the reliability and signal characteristics of FBGS embedded in composite laminates. The microphotographs of embedded optical fibers visualized the embedding environments of stripped optical fibers and coated optical fibers. Based on these microphotographs and cure monitoring performed using FBGs, we could understand that the main cause breaking the unique Bragg condition of low-birefrigence FBG were residual stress artier curing and reported the stale of stress/strain of optical fiber quantitatively. The cure monitoring also showed the history of splitting peak of a stripped FBG along cure processing. In addition, we could obtain a transverse insensitive grating(TIG) with ease by recoating a stripped FBG. TIG has good advantage for real-time signal processing.

Sensing characteristics of a non-dispersive infrared CO2 sensor using a Fabry-Perot filter based on distributed Bragg reflector (분산 반사경 기반 패브리-페로 필터를 이용한 비분산적외선 CO2 센서의 감지 특성)

  • Do, Nam Gon;Lee, Junyeop;Jung, Dong Geon;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.446-450
    • /
    • 2021
  • Non-dispersive infrared (NDIR) gas sensors typically use an optical filter that transmits a discriminating 4.26 ㎛ wavelength band to measure carbon dioxide (CO2), as CO2 absorbs 4.26 ㎛ infrared. The filter performance depends on the transmittance and full width at half maximum (FWHM). This paper presents the fabrication, sensitivity, and selectivity characteristics of a distributed Bragg reflector (DBR)-based Fabry-Perot filter with a simple structure for CO2 detection. Each Ge and SiO2 films were prepared using the RF magnetron sputtering technique. The transmittance characteristics were measured using Fourier-transform infrared spectroscopy (FT-IR). The fabricated filter had a peak transmittance of 59.1% at 4.26 ㎛ and a FWHM of 158 nm. In addition, sensitivity and selectivity experiments were conducted by mounting the sapphire substrate and the fabricated filter on an NDIR CO2 sensor measurement system. When measuring the sensitivity, the concentration of CO2 was observed in the range of 0-10000 ppm, and the selectivity was measured for environmental gases of 1000 ppm. The fabricated filter showed lower sensitivity to CO2 but showed higher selectivity with other gases.

Positron Annihilation Lifetime Study on the Proton-Irradiation BaSrFBr : Eu Film (양전자 소멸 수명 측정에 의한 양성자 조사된 BaSrFBr : Eu 박막 특성)

  • Im, Yu-Suk;Lee, Chong-Yong
    • Korean Journal of Materials Research
    • /
    • v.20 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • Positron annihilation lifetime spectroscopy is applied to BaSrFBr : Eu film which is used for the phosphore layer, and afterwards the reliability and self-consistency of source corrections in the positron lifetime spectroscopy is investigated using a $^{22}Na$ positron emitter covered by thin foils. The positron lifetime showed no significant change through the various proton irradiation energies. It is unusual that the measurements of the defects indicate that most of the defects were likely to have been generated by X-ray radiation. This may have resulted from the Bragg peaks of the proton characteristics. The Bragg peak does not affect the defect signals enough to distinguish the lifetimes and intensities in a material that is includes multi-grains. The lifetime ($\tau_1$) associated with positron annihilations in the Ba, Br, and Eu of the sample was about 250 ps, and due to the annihilations at F-centers or defects from the irradiated protons in sample, the lifetime ($\tau_2$) was about 500 ps.

Measurement of Transverse Strain Using Polarization Maintaining Fiber Bragg Grating Sensor (편광 유지 광섬유 브래그 격자 센서를 이용한 횡방향 변형률 측정)

  • Yoon, Hyuk-Jin;Kim, Dae-Hyun;Hong, Chang-Sun;Kim, Chun-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.30-35
    • /
    • 2003
  • In this paper, the transverse strain was measured using polarization maintaining fiber Bragg grating(PMFBG) sensor. PMFBG sensor was fabricated using phase mask and Excidmer laser. The reflected wavelength of PMFBG sensor had dual peaks due to intrinsic birefringence. To find the polarization axes, peak sensitivity was measured under compression test. The signal characteristics of PMFBG sensor were also examined in embedding condition. The embedded PMFBG sensor in epoxy block was loaded for the transverse strain measurement, The wavelength-swept fiber laser(WSFL) was used to construct the PMFBG sensor system. Experiments showed that the PMFBG sensor could successfully measure the transverse strain.

Distributed Fiber-Optic Temperature Sensor Network for Protection of Electric Power Systems (전력설비 보호를 위한 분배형 광섬유 온도센서)

  • Park, Hyoung-Jun;Lee, June-Ho;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.64-71
    • /
    • 2006
  • We developed a fiber-optic temperature sensor system, with 10 fiber Bragg gratings, for abnormal high-temperature monitoring in power systems. We used Gaussian line-fitting algorithm to compensate the spectrum distortion in the wavelength-scanned Farby-Perot filter demodulation scheme. Compared with highest-peak-detection method, the proposed algorithm substantially reduced measurement errors. The overall measurement error was less than 1[%] compared with the reference thermocouple and the linearity error was 0.37[%].

1-D photonic crystals of free-standing DBR PSi for sensing and drug delivery applications (비고정화 된 일차원 광결정의 DBR 다공성 실리콘을 이용한 센서와 Drug Delivery로의 응용)

  • Koh, Young-Dae;Kim, Ji-Hoon;Park, Jong-Sun;Kim, Sung-Gi;Kim, Dong-Su;Cho, Sung-Dong;Sohn, Hong-Lae
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.391-396
    • /
    • 2006
  • Free-standing multilayer distributed Bragg reflectors (DBR) porous silicon dielectric mirrors, prepared by electrochemical etching of crystalline silicon using square wave currents are treated with polystyrene to produce flexible, stable composite materials in which the porous silicon matrix is covered with caffeine-impregnated polystyrene. Optically encoded DBR PSi/polystyrene composite films retain the optical reflectivity. Optical characteristics of DBR PSi/polystyrene composite films are stable and robust for 2 hrs in a pH=7 aqueous buffer solution. The appearance of caffeine and change of DBR peak were simultaneously measured by UV-vis spectrometer and Ocean optics 2000 spectrometer, respectively.

A Study on the High-Temperature Characteristics of a Tunable All-Optical Filter Using Fiber Bragg Grating (FBG를 이용한 파장가변 형 전광 필터의 고온 특성에 관한 연구)

  • Son, Yong-Hwan;Yang, Se-Hoon;Kim, Hyun-Seung;Han, Sang-Kook
    • Journal of IKEEE
    • /
    • v.14 no.4
    • /
    • pp.263-269
    • /
    • 2010
  • In this paper, we present high temperature characteristics of a tunable all-optical filter using fiber Bragg grating(FBG) filter in Ge doped and Ge & B co-doped fiber, including peak reflectivity, bandwidth and various normalized refractive index change with temperature variation. The reflection spectrum of a FBG filter with refractive index change is affected by its thermal stability. Consequently Ge doped FBG tunable filter has a better thermal stability than Ge & B co-doped FBG tunable filter. Also, both FBG tunable filters show good thermal stability up to about $500^{\circ}C$.

Study on the Fluence and LET Distribution of Projectile Fragments Produced from Heavy Ion Therapeutic Beams

  • Komori, Masataka;Fukumura, Akifumi;Hirai, Masaaki;Kanai, Tatuaki;Kohno, Ryosuke;Kohno, Toshiyuki;Matsufuji, Naruhiro;Nanbu, Syuya;Nishio, Teiji
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.216-218
    • /
    • 2002
  • Fluence and LET spectrum for 290,400 MeV/u $\^$12/C and 400 MeV/u $\^$20/Ne beams have been measured by a $\Delta$E-E counter telescope. Total charge-changing cross sections are deduced from measured fluence. The measured cross sections agree with previous measurements, however, they are disagreement with a model calculation. To dose-averaged LETs, the model calculation can reproduce the measured LETs except for peak LETs at Bragg peak region.

  • PDF

Implementation of real-time optical pattern recognition system using a photorefractive correlator with improved shift-invariant property (변이불변 특성이 개선된 광굴절 상관기를 이용한 실시간 광 패턴인식 시스템 구현)

  • 김성완;김철수;김종찬;김종윤;이승희;김수중
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.3
    • /
    • pp.63-69
    • /
    • 1998
  • In this paper, a new input method is proposed to improve shift-invariant property of a photorefractive correlator andwe implemented real-time optical pattern recognition system using it. In the conventional photorefractive correlator, it is vrey difficult to satisfy the Bragg condition in the pattern recognition process. So, correlation peak is decreased heavily for the shift of input image. If a liquid crystal television(LCTV) without an anlyzer is used as input device, we can get the correlation result regardless of shift of input image because beam path is not changed during storage of holographic filter and correlation process. Also recording time of a holographic matched filter in photorefractive crystal is reduced and the correlation peak is increased because incident beam on the LCTV is transmitted completely. Therefore total optical efficiency is improved. We compared and analyzed the correlation results of proposed photorefractive correlator by computer simulation and optical experiment. We used a BaTiO$_{3}$ single crystal which has high diffraction efficiency in optical experiment.

  • PDF

Carbon-ion radiotherapy in osteosarcoma of the mandible: a case report

  • Ha, Tae-Wook;Park, Slmaro;Youn, Min Yeong;Kim, Dong Wook;Kim, Hyung Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.4
    • /
    • pp.315-320
    • /
    • 2021
  • Carbon-ion radiotherapy (CIRT) is on the rise as a treatment choice for malignant tumor. Compared to conventional radiotherapy, particle beams have different physical and biological properties. Particle beam provides a low entry dose, deposits most of the energy at the endpoint of the flight path, and forms an asymptotic dose peak (the "Bragg peak"). Compared to protons, carbon with its larger mass decreases beam scattering, resulting in a sharper dose distribution border. We report a 50-year-old male who underwent CIRT without surgical resection on osteosarcoma of the mandible. After CIRT, the patient's pain was gone, and the malignant mass remained stable with accompanying necrosis. Nine months later, however, magnetic resonance imaging demonstrated progression of the left mandibular osteosarcoma with pulmonary metastases. After multidisciplinary discussion, concurrent chemoradiotherapy was conducted. While necrotic bone segments came out of the mandible during subsequent periodic outpatient visits, the tumor itself was stable. Thirty months after his first visit and diagnosis, the patient is waiting for chemotherapy. Although CIRT is superior in treating radioresistant hypoxic disease, CIRT is in its infancy, so care must be taken for its indications and complications.