• Title/Summary/Keyword: Boost converter

Search Result 1,288, Processing Time 0.029 seconds

A Study on DSP Conrolled Photovoltaic System with Maximum Power Tracking

  • Ahn, Jeong-Joon;Kim, Jae-Mun;Kim, Yuen-Chung;Lee, Joung-Ho;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.966-971
    • /
    • 1998
  • The studies on the photovoltaic system are extensively exhaustible and broadly available resourse as a future energy supply. In this paper, a new maximum power point tracker(MPPT) using neural network theory is proposed to improve energy conversion efficiency. The boost converter and neural network controller(NNC) were employed so that the operating point of solar cell was located at the Maximum Power Point. And the back propagation algorithm with one input layer of two inputs(E, CE) and output layer(cnntrol value) was applied to train a neural network. Simulation and experimental results show that the performance of NNC in MPPT of photovoltaic array is better than that of controller based upon the Hill Climbing Method.

  • PDF

Transformer-less Boost Converter with High Gain and Low Current Ripple for Fuel Cell Applications (연료전지응용을 위한 높은 승압비와 낮은 전류리플을 갖는 무변압기형 부스트컨버터)

  • Park Chan-Ki;Yang Jin-Young;Kim Hyung-Joon;Choi Se-Wan;Ju Ri-A;Kim Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.348-351
    • /
    • 2006
  • 연료전지로부터의 낮고 변동폭이 큰 전압을 안정되게 승압시키기 위하여 부스트 컨버터가 사용되고 있으며 전기적인 절연이 요구되지 않는 응용에서는 손실, 가격 및 부피 상승의 원인이 되는 고주파변압기가 없는 무변압기형의 부스트 컨버터가 장점을 갖는다. 본 논문에서는 $6{\sim}8$배의 실제 사용 가능한 승압비를 가지며 입출력 전류리플이 매우 작은 새로운 무변압기형 부스트 컨버터를 제안하고 모의실험을 통하여 그 타당성을 검증한다.

  • PDF

Transformer-less Type Grid-Connected PV Power Conditioning System (변압기 없는 계통연계형 PV PCS고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.551-554
    • /
    • 2002
  • This paper describes a new interactive inverter between a photovoltaic(PV) array and single-phase utility that avoid the bulky input (60Hz) transformer on the AC side. The interface employs a pwm boost converter on the DC side followed by a pwm current-forced single-phase rectifier for injecting the power from the PV array into the mains. The current waveform at the AC side remains sinusoidal and exactly in phase at all time. The circuit also has the advantage of requiring fewer switching device than high-frequency link system. This paper describes modeling of PV array and new system topology. Simulation results on the performance of the connection are also presented.

  • PDF

Design of High Efficiency Boost Bidirectional DC/DC Converter Circuit and Layout For EV (EV용 고효율 승압형 양방향 DC/DC컨버터의 회로 및 구조설계)

  • Choi, Jin-Ho;Song, Sung-Geun;Choi, Mi-Seon;Kim, Dae-Kyong
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.33-34
    • /
    • 2010
  • 본 논문에서는 기 제작된 전기자동차용 고효율 승압형 양방향 DC/DC 컨버터의 소형/경량화 및 전력밀도의 상승을 위한 구조설계를 제안한다. 제안된 컨버터는 1차 측 Full-Bridge 회로와 고조파 변압기 부, 2차 측 배압회로를 구성하고 변압기에 존재하는 누설인덕턴스 성분과 배압회로의 커패시터 성분을 이용하여 직렬 L-C공진회로를 구성함으로서 모든 스위치에 ZCS (Zero Current Switching)을 구현하여 전체 사이즈 및 비용을 감소시키고자 하였다. 제안된 방식의 타당성을 입증하기 위하여 전력밀도의 비교 및 PSIM 시뮬레이션으로 본 논문에서 제안된 컨버터 구조의 타당성을 검증하고자 한다.

  • PDF

High Efficiency Boost Bidirctional DC/DC Converter For EV (EV용 고효율 승압형 양방향 DC/DC컨버터)

  • Choi, Mi-Seon;Song, Sung-Geun;Kim, Dae-Kyong;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.31-32
    • /
    • 2010
  • 본 논문에서는 에너지 순환을 위해 회생제동을 할 수 있는 전기자동차용 고효율 승압형 양방향 DC/DC 컨버터를 제안한다. 제안된 컨버터는 1차 측 Full-Bridge 회로와 고조파 변압기 부, 2차 측 배압회로를 구성하고 변압기에 존재하는 누설인덕턴스 성분과 배압회로의 커패시터 성분을 이용하여 직렬 L-C공진회로를 구성함으로서 모든 스위치에 ZCS (Zero Current Switching) 을 구현함으로서 전체 사이즈 및 비용을 감소시키고자 하였다. 제안된 방식의 타당성을 입증하기 위하여 PSIM 시뮬레이션으로 본 논문의 컨버터 구조의 타당성을 검증하고자 한다.

  • PDF

Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps (고압 나트륨 램프 구동용 전력변환장치의 역률 개선)

  • Lee, S.H.;Suh, K.Y.;Lee, H.W.;Lee, S.H.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

Fuzzy Control of a Boost Converter for Solar Cell Applications (태양전지용 승압형 컨버터의 시비율 퍼지제어)

  • Lee, Woo-Hee;Kim, Hyung-Jin;Chun, Kyung-Min;Lee, Jun-Ha;Lee, Hoong-Joo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.271-275
    • /
    • 2006
  • 본 논문에서는 태양광 발전시스템의 최대전력추종을 위해 퍼지 이론을 도입한 퍼지제어기를 설계하였다. 퍼지제어기의 디지털 설계를 위해 태양광 발전시스템의 각 부분을 구성하고, FPGA를 사용하여 제어기를 구현하였다. 구현된 제어기는 일사량의 변화에도 안정적으로 동작하며, 출력전압의 리플이 작은 결과를 보였다. 또한 FPGA의 퍼지제어기로서의 구현가능성을 발견하고 그 타당성을 입증하였다.

  • PDF

Maximum power point tracking method for building integrated PV system (건물용 태양광 컨버터의 최대전력 추종 기법 개발)

  • Yu, Byung-Gyu;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.299-303
    • /
    • 2011
  • This paper proposes a novel sensorless maximum power point tracking (11PPT) algorithm for PV systems. The method is based on dividing the operating time into several intervals in which the PV terminals are short circuited in one interval and the calculated short-current of the PV is obtained and used to determine the optimum operating point where the maximum output power can be obtained. The proposed MPPT algorithm has been introduced into a current-controlled boost converter whose duty ratio is controlled to the maintain MPP condition. The same sequence is then repeated regularly capturing the PV maximum power. The main advantage of this method is eliminating the current sensor. Meanwhile, this MPPT algorithm reduces the power oscillations around the peak power point which occurs with perturbation and observation algorithms. In addition, the total cost will decrease by removing the current sensor from the PV side. Finally, simulation results confirm the accuracy of the proposed method.

  • PDF

Soft-switching Bridgeless Boost PFC Converter with Phase-shifting Control (위상 천이 기법을 적용한 소프트 스위칭 토템폴 브리지리스 부스트 PFC 컨버터)

  • Park, Moo-Hyun;Baek, Jae-Il;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.204-206
    • /
    • 2018
  • 본 논문에서는 대용량 전력 어플리케이션에 적합한 인터리브드 토템폴 브리지리스 부스트 PFC 컨버터의 전입력전압 범위, 전부하에서 소프트 스위칭을 달성하여 높은 효율을 얻는 새로운 PFC 컨버터를 제안한다. 기존의 회로는 하드 스위칭에 의해 큰 스위칭 손실을 가져 효율이 낮을 뿐만 아니라 소자에 부담을 주어 높은 성능의 방열 시스템을 필요로 한다. 제안하는 컨버터는 하나의 인덕터가 추가되었으며, 위상 천이 기법을 통해 적절한 크기의 전류를 생성하여 소프트 스위칭을 달성하면서도 추가적인 손실을 최소화 한다. 따라서 전 부하에 걸쳐 높은 효율을 얻을 수 있다.

  • PDF

Development of Dynamic Voltage Restorer System Considering Characteristics of EDLC (EDLC의 특성을 고려한 동적전압보상시스템의 개발)

  • Lee, Sang-Cheol;Seo, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.288-292
    • /
    • 2010
  • Recently, in energy storage system, the EDLC is paid attention as a new environmentally friendly energy storage element. This capacitor has higher energy density than the electrolytic capacitor. Also, this capacitor has a lot of advantage such as no maintenance, longer life cycle and faster charge-discharge time than the battery system. But the EDLC must have a each charge-discharge controller to effectively control, an energy design method circuit to use effectively energy, and several compensation techniques to control a optimal operating. In this respect, this study suggests major parameters to effectively represent the characteristics of EDLC, the measurement methods of those parameters have been investigated with experiments, and the interpretation about the buck/boost DC/DC converter for the operation of EDLC.