• Title/Summary/Keyword: Bone screws

Search Result 185, Processing Time 0.031 seconds

CLINICAL STUDY OF RESORBABLE PLATE AND SCREW FOR TREATMENT OF MAXILLOFACIAL FRACTURES (악안면 골절 치료시 흡수성 고정판의 사용에 관한 임상 연구)

  • Jeong, Jong-Cheol;Choi, Se-Hoon;Song, Min-Soek;Jun, Chang-Hun;Kim, Hyun-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.6
    • /
    • pp.438-443
    • /
    • 2003
  • Purpose : This study evaluated the usefulness of resorbable plate and screw for treatment of maxillofacial bone fractures. Patients and methods : From july, 2000 to july, 2002, we used resorbable plates and screws($Biosorb^{(R)}$ FX, Bionix Inc, Finland) on 126 patients for treatment of maxillofacial bone fractures. Among them, 80 patients were capable of periodic following up to present season. We evaluated these patients with clinical, radiographic findings and subjective satisfaction. Results : 80 patients composed of 63 men and 17 women. Complication rates are 7.5%(6/80) recorded. 1 of bulging sensation, 3 of infection sign, 2 of the plate detachment were shown. The plates involved in such complications were removed. The other patients(92.5%) were not shown any problems. We could not find complete resorption of screw holes in the mandibular symphysis area even though two years later after surgery. Conclusion : Bioresorbable plates and screws are useful as fixation material at maxillofacial fractures although strength is thought to be weaker than titanium plate. But to reduce the possible complicaions, need to careful clinical and radiographical evaluations.

Gait Analysis and Functional Outcomes Following Pan Tarsal Arthrodesis of Tarsal Joint in a Toy Poodle

  • Song, Jaeyong;Kim, Jun-Hyung;Woo, Heung-Myoung;Kang, Byung-Jae
    • Journal of Veterinary Clinics
    • /
    • v.36 no.2
    • /
    • pp.123-125
    • /
    • 2019
  • A 12-year-old castrated Toy Poodle was referred with a continuous non-weight bearing lameness of right hind limb due to a traffic accident 9 years ago. Physical examination and radiographs revealed partial loss of right calcaneal bone, loss of Achilles tendon and disused muscular atrophy. Arthrodesis was performed to preserve the function of the right hind limb. Pan tarsal arthrodesis plate was applied medially with 2.7 mm cortical screws and 2.0 mm cortical screws. During fixation, cancellous bone chip was transplanted into the arthrodesis site. A bone union was confirmed 9 weeks after surgery. Furthermore, on the gait analysis, the weight-bearing of right hind limb was restored to 70% of the opposite hind limb. Arthrodesis can be used to treat more difficult and serious problems affecting the joints. In particular, arthrodesis is indicated in cases such as comminuted intraarticular fractures and irreparable injury of the calcaneal tendon apparatus in the hock joint. In this case, the pan tarsal arthrodesis provided stability to the hock joint and improved the gait by restoring severe chronic damage. In conclusion, we successfully treated a challenging disability of hock joint using pan tarsal arthrodesis to restore the legs that were non-weight bearing due to chronic injury by traffic accident and objectively ascertained the increased weight bearing by gait analysis.

Numerical Stress Analysis of bone plate System using 3-dimensional finite element method (3차원 유한 요소법을 이용한 골절판의 응력 해석)

  • Kim, Hyun-Su;Kwon, Young-Soo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.74-78
    • /
    • 1991
  • Conventional compression bone fracture plates sometimes cause osteoporosis under the plate due to their high rigidity which in turn transfer physiological load mostly through the plates and screws. In order to prevent the osteopenia we have designed a system which have a viscoelastic washer between plate and screw head. The washer is made of a biocompatible ploymer (untra high molecular weight polyethylene, UHMWPE). Three-dimensional finite element meshes of the human femur with the conventional and new concept bone plate ere generated and the comparative stress analyses are performed with static half-stance loading condition. The results of analyses showed that could reduce the stress shielding effect compared with the conventional plate.

  • PDF

THE TRANSMANDIBULAR IMPLANT SYSTEM (The Transmandibular Implant System)

  • Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.435-444
    • /
    • 1997
  • Many of the problems which are faced to the edentulous patients are related to a minimal amount of available mandibular bone volume and height. Most of the patients with mild atrophy of the mandible are treated using endosseous implant prosthodontics. TMI(Trans-mandibular Implant) can be used in case of severe mandibular atrophy, poor bone quality, atrophy of the mandible with exposed of inferior alveolar nerve, osteoporosis and the fracture of the atrophic mandible. Also it can eliminate the need for bone grafting and vestibuloplasty. The TMI is a rigid box frame structure which controls and distribute the masticatory force over the severely resorbed mandible. The box frame structure consist of a superstructure, baseplate, 4 transosseous posts, and 5 cortical screws. This is a case report that also describes about the transmandibular implant reconstruction system.

  • PDF

Metastasis of renal cell carcinoma around suture anchor implants

  • Baek, Samuel;Shin, Myung Ho;Kim, Tae Min;Oh, Kyung-Soo;Lee, Dong Ryun;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.110-113
    • /
    • 2021
  • We present an unusual case of bone metastases from renal cell carcinoma around orthopedic implants in a 78-year-old female with osteolytic, expansile, highly vascularized, malignant infiltration around suture anchors in the proximal humerus. The patient had undergone arthroscopic rotator cuff repair using suture anchor implants 6 years previously. After diagnosis of bone metastasis, she was successfully treated with metastasectomy and internal fixation using a plate and screws, with cement augmentation. This report is the first to document metastases around a suture anchor in a bone and suggests the vulnerability of suture anchor implants to tumor metastasis.

Study of Bio-absorbability and Bio-compatibility of Poly-L-lactic-acid Implant in Dogs (개에서 Poly-L-lactic-acid 이식물의 생분해성과 생체적합성에 관한 연구)

  • Park, Po-Young;Kim, Young-Ki;Bahk, Jong-Yoon;Park, Joung-Man;Koh, Phil-Ok;Chang, Hong-Hee;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.182-191
    • /
    • 2007
  • Bioabsorbable devices have been utilized and experimented in many aspects of orthopaedic surgery. Depending upon their constituent polymers, these materials can be tailored to provide sufficient rigidity to allow bone healing, retain mechanical strength for certain period of time, and then eventually begin to undergo degradation. The objective of this study was to estimate extent in which Poly-L-latic acid (PLLA) implants had bioabsorbability and biocompatibility with bone and soft tissue in dogs and also to develop bioabsorbable, biocompatible materials with the appropriate strength and degradation characteristics to allow for regular clinical use for treating orthopedic problems in humans as well as animals. Eighteen dogs were used as experimental animals and were inserted two types of PLLA implants. PLLA rods were inserted into subcutaneous tissue of back or the abdomen wall. And the rods were tested for material properties including viscosity, molecular weight, melting point, melting temperature, crystallinity, flexural strength, and flexural modulus over time. PLLA screws were inserted through cortical bone into bone marrow in the femur of the dogs and stainless steel screw was inserted in the same femur. Radiographs were taken after surgery to observe locations of screw. Histological variations including cortical bone response, muscular response, bone marrow response were analyzed over the time for 62weeks. The physical properties of PLLA rods had delicate balances between mechanical, thermal and viscoelastic factors. PLLA screws did not induce any harmful effects and clinical complications on bone and soft tissue for degradation period. These results suggest that PLLA implants could be suitable for clinical use.

Treatment of Open Calcaneal Fracture with Massive Bone Loss using Femoral Head Allograft and Myocutaneous Free Flap (A Case Report) (종골 외측 1/2 이상의 결손을 동반한 개방성 골절의 동종 대퇴골두 이식과 유리 피판술을 이용한 치료 (1예 보고))

  • Sung, Ki-Sun;Eun, Sang-Soo;Mun, Goo-Hyoun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.111-114
    • /
    • 2007
  • Open calcaneal fracture with more than lateral half of bone loss and soft tissue defect occurred in 17 year-old male patient due to motor vehicle accident. Soft tissue defect included heel pad, peroneal tendon. Bone loss involved mainly most part of inferior tuberosity but not subtalar joint. Open dressing and debridement were done daily in operating room and antibiotics administration was started. After granulation tissue formed, femoral head allograft was performed and fixed with 6.0 mm screws to replace bone defect. Soft tissue defect was covered with latissimus dorsi musculocutaneous free flap. No sign of infection nor major osteolysis was observed in 15 months follow up period. Soft tissue defect was covered with latissimus dorsi musculocutaneous free flap.

  • PDF

FEM Analysis of Lumbar Interbody Fusion using the Cage and Screw in Relation to Bone Mineral Density (골밀도 변화에 따른 cage와 나사를 이용한 추체간 유합술의 유한요소 해석)

  • Kim H. S.;Park J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.525-530
    • /
    • 2004
  • Three dimensional finite element models of lumbar interbody fusion using rage and screws were constructed for the simulation of stress distribution and maximum displacement. It is also performed to investigate the efforts of osteoporosis and the location of cage on the stress distribution. It is known from the results that the increase of the strength of trabecular bone causes to decrease the stress of cortical bone and to increase the stress of trabecular bone. And it is found that the trend of stress distribution is changed by the change of location of cage and proper location of cage enhances the rate of operational success.

THE EFFECT OF RIGID FIXATION ON THE FRONTONASAL SUTURE IN GROWING RABBITS (강성(剛性) 고정(固定)이 성장중(成長中)인 가토(家兎)의 전두비골봉합(前頭鼻骨封合)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Hyo-Jong;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.3
    • /
    • pp.290-302
    • /
    • 1994
  • This study was aimed to clarify the histopathological changes in the experimental animal model subjcted to rigid fixation performed across the frontonasal sutrue in growing rabbits. Sixteen rabbits aged 6 weeks used. In experimental group(n=12), rigid fixation with miniplates and screws was performed across the frontonasal suture. Control group(n=4) was those with periosteal elevation only. Experimental animals were sacrificed on the 2nd, 4th, 8th, and 12th week after operation, and frontonasal suture area was excised for light microscopic and scanning electron microscopic examination. The results obtained were as follows : 1. In control groups, collagen fiber bundles ran in the midportion of bone sutrue and cambial layers were seen at bone surface. Sutural surfaces are beveled and external and internal bony projected portions were observed. 2. In experimental groups, distance of bone suture was decreased by new bone formation on the 2nd week, while increased by bone resorption at the miniplate applied area and bone formation in the adjacent bone on the 4th week. 3. In experimental groups, the original bone surface was almost resorbed and new bone formation was found on the 8th week. Regulary-run collagen fibers, smooth and dense bone surfaces were similar to the bone patterns of control groups on the 12th week. Above results suggest that bone formation is restricted where the miniplate is applied, while compensatory growth is appeared in the adjacent bont. It is considered that rigid fixation with miniplates and acrews results in a little disturbance of sutural growth of the craniofacial bone in infancy and children when applied for short duration.

  • PDF

Stress analysis according to the vertical bone level in the implant placement (임플란트 매식 시 수직골 높이에 따른 응력분석)

  • Kim, Min-Ho;Park, Young-Rok;Kay, Kee-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.