CLINICAL STUDY OF RESORBABLE PLATE AND SCREW FOR TREATMENT OF MAXILLOFACIAL FRACTURES |
Jeong, Jong-Cheol
(Dept. of Oral and Maxillofacial Surgery, Gachon Medical School, Gil Medical Center)
Choi, Se-Hoon (Dept. of Oral and Maxillofacial Surgery, Gachon Medical School, Gil Medical Center) Song, Min-Soek (Dept. of Oral and Maxillofacial Surgery, Gachon Medical School, Gil Medical Center) Jun, Chang-Hun (Dept. of Oral and Maxillofacial Surgery, Gachon Medical School, Gil Medical Center) Kim, Hyun-Min (Dept. of Oral and Maxillofacial Surgery, Gachon Medical School, Gil Medical Center) |
1 | Alpert B, Seligson D: removal of asymptomatic bone plate used for orthognathic surgery and facial fractures. J Oral Maxillofac Surg. 1996;54(5):618-621. DOI PUBMED ScienceOn |
2 | Kim YK, Yeo HH, Lim SC: Tissue response to titanium plates; A transmitted electron microscopic study. J Oral Maxillofac Surg. 1997;55(4):322-326. DOI ScienceOn |
3 | Cutright DE, Hunsuck EE, Beasley JD: Fracture reduction using a biodegradable material, polylactic acid. J Oral Surgery 1971;29:393-7. |
4 | Bergma EJ, Rozema FR, Bos RRM: Foreign body reaction to resorbable poly(L-lactic acid) bone plates and screws used for the fixation of unstable zygomatic fractures. J Oral Maxillofac Surg 51:666-670,1993. |
5 | Landes CA, Kriener S, Menzer M, Kovacs AF: Resorbable plate osteosynthesis of dislocated or pathological mandibular fractures: A prospective clinical trial of two amorphous L-/DL-Lactide copolymer 2-mm miniplate systems. Plast Reconstr Surg 111(2):601-610, 2003. DOI ScienceOn |
6 | Suuronen R, Kallela I, Laine P, Ranta P, Iizuka T, Lindqvist C: Osteotomy site healing following mandibular sagittal split osteotomy and rigid fixation with polylactide biodegradable screws. Int J Oral Maxillofac Surg 1999 June; 28(3):166-170. DOI ScienceOn |
7 | 류동목, 박현욱, 이한주, 허원실 : 흡수성고정판이 가토 악골골절의 치유에 미치는 영향. 대한악안면성형재건외과학회지 1999;21.vol 2:131-138. |
8 | Tuovinen V, Norholt SE, Sindet-pedersen S, Jensen J: A retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium. J Oral Maxillofac Surg 1994;52:931-935. DOI PUBMED ScienceOn |
9 | Suuronen R, Ashammakhi N, Tiainen J, Tormala P, Waris T: Spotlight on Naturally Absorbable Osteofixation Devices. J Craniofac Surg 2003 March ;14(2):247-259. DOI ScienceOn |
10 | Ellis E III, Walker LR: Treatment of mandibular angle fractures using on noncompression miniplate. J Oral Maxillofac Surg 1996;54:864-872. DOI ScienceOn |
11 | Kim YK, Kim SG: Treatment of mandibular fracture using bioresorbable plates. Plast Reconstr Surg 2002;110:25-31. DOI ScienceOn |
12 | Suuronen R, Kallela I, Lindqvist C : Bioabsorbable screw: Current state of the art in facial fracture repair. J craniomaxillofac Trauma 2000;6(1):19-27. PUBMED |
13 | Ascherman J, Knowles S, Marin V, Prisant N: Cranial Reossification with absorbable plates. Plast Reconst Surg 2001;107:763-768. DOI ScienceOn |
14 | Kallela I, Iizuka T, Salo A, Lindqvist C: Lagscrew fixation of anterior mandibular fracture using biodegradable polylactide screw: a preliminary report. J Oral Maxillofac Surg 1999;57:113-118. DOI ScienceOn |
15 | Harada K, Enomoto S: Stability after surgical correction of mandibular prognathism using the sagittal split ramus osteotomy and fixation with poly-L-lactic acid screws. J Oral Maxillofac Surg 1997;55:464-468. DOI ScienceOn |
16 | Suuronen R, Ashammakhi N, Peltoniemi H, Waris E, Serlo W, Kellomaki M, Tormala P, Waris T: Developments in Craniomaxillofacial Surgery: Use of Self-Reinforced Bioabsorbable Osteofixation Devices. Plast Recon Surg 2001 July; 108(1):167-180. DOI ScienceOn |
17 | Bostman O, Hirvensalo E, Makinen J, Pokkanen P: Foreign body reactions to fracture fixation implants of biodegradable synthetic polymer. J Bone Joint Surg 1990;72-B: 592-6. DOI |
18 | Bessho KB, Ilzuka T, Murakami KI: A bioabsorbable poly-l- lactic acid miniplate and screw system for osteosynthesis in oral and maxillofacial surgery. J Oral Maxillofac Surg 55:941-945,1997. |
19 | Bostman O: Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg 1991;73-B:679-82. DOI |
20 | Shetty V, Caputo AA, Kelso I: Torsion-axial force characteristics of SR-PLLA screws. J Cranio Maxilofac Surg 1997;25:19-23. DOI ScienceOn |
21 | Edwards RC, Kiely KD, Eppley BL: The fate of resorbable poly-L-lactic/ polyglycolic acid bone fixation devices in orthognathic surgery. J Oral Maxillofac Surg 2001;59:19-25. DOI ScienceOn |
22 | Suuronen R, Manninen MJ, Pohjonen T, Laitinen O, Lindqvist C: Mandibular osteotomy fixed with biodegradable plate and screw:an animal study. Brit J Oral Maxillofac Surg 1972;4:341-347. |
23 | Suuronen R, Peltoniemi H, Ashammakhi N, Kontio R, Waris T, Salo A, Lindqvist C, Gratz K: The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Rad Endodont 2002 July; 94(1):5-14. DOI ScienceOn |
24 | Harada K, Enomoto S: Stability after surgical correction of mandibular prognathism using the sagittal split ramus osteotomy and fixation with poly-L-lactic acid screws. J Oral Maxillofac Surg 1997;55:464-468. DOI ScienceOn |