• Title/Summary/Keyword: Bone screws

Search Result 188, Processing Time 0.03 seconds

Horizontal Ridge Augmentation using Ridge Expansion and Autogenous Tooth Bone Graft: A Case Report (치조능확장술과 자가치아골이식술을 이용한 치조능 수평증대술: 증례보고)

  • Kim, Young-Kyun;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.109-115
    • /
    • 2011
  • Implants were placed after performing ridge expansion by inserting screws of gradually increasing thickness. Favorable clinical outcome was obtained. During surgery, buccal cortical plate fracture did not occur. Autogenous tooth bone graft material was grafted around the implant dehiscence defects and over the buccal cortical plate. The method involving the insertion of screws for ridge expansion is a successful and predictable technique for implant placement in narrow alveolar bone. Autogenous tooth bone graft material can be used for ridge augmentation and GBR.

Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews

  • Yun, Soon-Dong;Choi, Sung-Hwan;Cha, Jung-Yul;Yu, Hyung-Seog;Kim, Kwang-Mahn;Kim, Jin;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.238-247
    • /
    • 2017
  • Objective: The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods: Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results: Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions: These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.

The Useful Method on Temporary Fixation with Screw-wire Technique (안면골절의 정복 및 고정을 위한 나사-강선의 사용)

  • Kim, Myung Hoon;Kwon, Yong Seok;Heo, Jung;Lee, Keun Cheol;Kim, Seok Kwun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.181-186
    • /
    • 2008
  • Purpose: Until now, many kinds of treatment modalities for facial bone fractures have been proposed. Among them, the semi-rigid fixation using miniplates has become the most popular procedure due to its simplicity and good clinical results. However, achieving anatomic reduction of bone fragments with miniplates may be difficult because of inadequate instrumentation for fracture fragment stabilization. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of fractured segment. Methods: We used this method for reduction in 50 cases of facial bone fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning bony segment. Postoperative radiologic and clinical follow-ups were performed.Results: Radiologic follow-up showed correct reduction and fixation in all cases. Nonnunion and malunion were not shown. Clinical follow-up showed an satisfactory results. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the bony segment to their preinjury position is easy to perform and it enables us to make more accurate reduction, ensure wider visual field.

Biomechanical analysis of pullout strength of the pedicle screws in relation to change bone mineral density (반복 하중 후 골밀도 감소에 따른 척추경 나사못의 고정력(Pullout Strength)감소 형태 분석)

  • Jung, D.Y.;Lee, S.J.;Kim, D.S.;Shin, J.W.;Kim, W.J.;Suk, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.155-156
    • /
    • 1998
  • Screw loosening and subsequent pullout can be attributed to the reduction in bone mineral density in the vertebrae manifested by osteoporosis in which the decrease in fixation strength between the cancellous bone and screw threads are accelerated by repeated loads exerted by patients own weight and activities following the surgery. In this study, the change in pullout strength of the pedicle screws was investigated before and after repeated loads were imparted. For this purpose. Diapason pedicle screws $(6.7\times40mm)$ were inserted onto fresh porcine spine specimens (T1-L5) after bone mineral density was measured using a DEXA. With an MTS, an axial load was applied at a loading rate of 0.33mm/sec until failure to measure the maximum pullout strength. Flexion moment of 7.5N-m was then imparted at 0.5Hz for 2000 cycles. It was found that the maximum pullout strength was exponentially related to BMD regardless of load types ($107.71\;\times\;\exp^{(1.43{\times}BMD)}r^2=0.93$, P<0.0001 without repeated load; ($107.71\;\times\;\exp^{(2.19{\times}BMD)}r^2=0.78$, P<0.0001 with repeated load). The results suggest that the reduction in pullout strength for pedicle screws is far more prominent in osteoporotic spine than in normal spine especially as number of repeated load was increased. More importantly, it was demonstrated that the level of bone mineral density and the activity level of the patient should be evaluated in more detail for successful implementation of pedicle screw systems in spinal surgery.

  • PDF

Evaluation of Insertion of torque and Pull-out strength of mini-screws according to different thickness of artificial cortical bone (다양한 교정용 미니 스크류의 인공 피질골 두께에 따른 삽입 토오크와 Pull-out 강도 비교)

  • Song, Young-Youn;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.5-15
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the mechanical performance of mini-screws during insertion into artificial bone with use of the driving torque tester (Biomaterials Korea, Seoul, Korea), as well as testing of Pull-out Strength (POS). Methods: Experimental bone blocks with different cortical bone thickness were used as specimens. Three modules of commercially available drill-free type mini-screws (Type A; pure cylindrical type, Biomaterials Korea, Seoul, Korea, Type B; partially cylindrical type, Jeil Medical, Seoul, Korea, Type C; combination type of cylindrical and tapered portions, Ortholution, Seoul, Korea), were used. Results: Difference in the cortical bone thickness had little effect on the maximum insertion torque (MIT) in Type A mini-screws. But in Type B and C, MIT increased as the cortical bone thickness Increased. MIT of Type C was highest in all situations, then Type B and Type A in order. Type C showed lower POS than Type A or B in all situations. There were statistically significant correlations between cortical bone thickness and MIT, and POS for each type of the mini-screws. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the best suitable screw design should be selected according to the different cortical thicknesses at the implant sites.

Ridge Augmentation for Implant Placement Using Chin Graft;A Case Report (하악골 전방부 골이식술후 임프란트의 매식;증례보고)

  • Kim, Su-Gwan
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.943-953
    • /
    • 1999
  • Severe alveolar ridge deficiency can prevent ideal implant placement. Ridge augmentation procedures are necessary to regain lost alveolar structures. The corticocancellous block bone graft was harvested from the mandibular symphysis. This block bone was fixed to the lateral aspect of the ridge with titanium screws. Seven months later, the autogenous bone graft was reentered and sufficient bone volume was gained to allow implant placement. The fixation screws were removed and 3I implants were inserted. No complication and postoperative alteration in chin contour were observed. This report demonstrates that chin graft offers a predictable alternative in the reconstruction of ridge deficiency for implant placement.

  • PDF

Repair of Closed Bilateral Mandibular Fractures Using Bone Plate and Screw in Dogs (개에서 골판을 이용한 비개방성 양측성 하악골절의 수복)

  • 정순욱;한현정;김지선;김준영;정만복
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.138-141
    • /
    • 2003
  • First case, a one-year-old female Shih Tzu weighing 3 kg with closed transverse fractures of bilateral mandibular body between 2nd and 3rd premolar teeth were treated surgically with bone plates and screws, and cranial luxation of temporomandibular joints were reduced to closed method. Second case, a 8.4 years old male Yorkshire terrier weighing 2.6 kg with closed transverse/oblique fractures of bilateral mandibular body between premolar and molar teeth were treated surgically with bone plates and screws. Radiographic examination revealed that the fractures in two cases fixed well and temporomandibular joint was stabilized. One month after operation, jaw activity was excellent and malocclusion wasn't observed.

The Efficacy of Newly Designed Screw for Prevention of the Screw Breakage in Syndesmosis Fixation: Biomechanical Study (나사 파단 예방을 위해 새로 디자인한 경비 인대 결합 나사의 효용성: 생역학 연구)

  • Lee, Dong-Oh;Song, Sang-Heon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.94-97
    • /
    • 2020
  • Purpose: Fatigue breakage of cortical screws sometimes occurs after syndesmosis fixation, regardless of the period of screw retention. This study compared the fatigue strength of a novel screw design to conventional cortical screws in the fixed state of syndesmosis. Materials and Methods: Twelve sawbone models were tested mechanically to determine the fatigue strength of three screw designs. The first group was composed of cortical screws, while the second and third groups were newly-designed screws. The second group was composed of screws with a 2.4-mm diameter thread-free portion of the mid-shank while the third group had a 2.0-mm diameter thread-free mid-shank. A 400 N load was applied repetitively to a fibula model and the number of cycles until screw failure was recorded. Four screws from each group were tested, giving a total of 12 fatigue tests. Results: The average cycles until screw failure for groups 1, 2, and 3 were 8,134, 63,186, and 2,581, respectively. The second group showed the highest fatigue strength (p=0.018). The other two screw designs showed similar fatigue strength (p=0.401). Conclusion: New screw designs with a thread-free portion in the mid-shank could reduce the occurrence of fatigue breakage after syndesmosis fixation.

Useful Corrosion - Potential of Magnesium Alloys as Implants

  • Kaya, A. Arslan;Kaya, R. Alper;Witte, Frank;Duygulu, Ozgur
    • Corrosion Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.162-167
    • /
    • 2008
  • Degradable implants have been in use for bone surgery for decades. However, degradable metal implants are one of the new research areas of biomaterials science. Magnesium has good biocompatibility due to its low toxicity, and it is a corroding, i.e. dissolvable, metal. Furthermore, magnesium is needed in human body, and naturally found in bone tissue. There have been some published reports also asserting the potential bone cell activation or bone healing effect of high magnesium ion concentrations. The classic method for achieving intertransverse process fusion involves autogenous iliac crest bone graft. Several investigations have been performed to enhance this type of autograft fusion. However, there is no research which has been undertaken to investigate the efficiency of pure magnesium particles in posterolateral spinal fusion. In this study, corrosion behavior of magnesium metal at the bone interface, the possibility of new bone cell formation and the degree of effectiveness in producing intertransverse process lumbar fusion in a sheep model have been investigated. Cortical bone screws were machined from magnesium alloy AZ31 extruded rod and implanted to hip-bones of sheep via surgery. Three months after surgery, the bone segments carrying these screws were removed from the sacrificed animals. Samples were sectioned to reveal Mg/bone interfaces and investigated using optical microscope, SEM-EDS and radiography. Optical and SEM images showed that there was a significant amount of corrosion on the magnesium screw. The elemental mapping results indicate, due to the presence of calcium and phosphorus elements, that there exists new bone formation at the interface. Furthermore, sixteen sheep were subjected to intertransverse process spinal fusions with pedicle screw fixation at various locations along their spines. Each animal was treated with 5cc autograft bone at one fusion level and 1cc magnesium+5cc autograft bone at the other. Six months after surgery, bone formation was evaluated by gross inspection and palpation, and radiological, histological, scanning electron microscopic and x-ray diffraction analyses. It may be stated that the potential for using useful corrosion of magnesium alloys in medical applications is expected to be significant.

STABILITY OF MAXILLARY POSITION AFTER LEFORT I OSTEOTOMY USING BIODEGRADABLE PLATES AND SCREWS (생체흡수성 고정장치를 이용한 상악골 이동술 후 장기간 결과)

  • Kim, Bong-Chul;Jung, Young-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.499-503
    • /
    • 2007
  • Introduction: In orthognathic surgery, internal fixation has been usually done with titanium plates and screws. Recently, Biodegradable plates and screws have been frequently used but the reports of long term results of postoperative stability are rare, especially after maxillary reposition in orthognathic surgery. Objective: In order to clarify the clinical utility of self-reinforced bioresorbable poly-70L/30DL-Lactide miniplates & screws in maxillary fixation after LeFort I osteotomy, this study examined the postsurgical changes in maxilla and complications of biodegradable plates and screws. Study design: Nineteen patients who had undergone maxillary internal fixation using biodegradable plates and screws were evaluated radiographically and clinically. A comparison study of the changes in maxilla position after surgery in all 19 patients was performed with 1-week, 1-month, 3-months, 6-months and/or 1-year postoperative lateral cephalograms by tracing. Complication of the biodegradable plates and screws was evaluated by follow-up roentgenograms and clinical observation. And one-way ANOVA test was used for statistical analysis. Results: The position of the maxillary bone was stable after surgery and was not changed significantly from 1 week to 1 year after operation. And we could not find any complication of biodegradable plates and screws. Conclusions: Internal fixation of the maxilla after LeFort I osteotomy using self-reinforced biodegradable plates and screws is a reliable method for maintaining postoperative position of the maxilla after LeFort I osteotomy.