1 |
Haers PE, Sailer HF: Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures. J Craniomaxillofac Surg 1998;26:363-372
DOI
|
2 |
Jorgenson DS, Mayer MH, Ellenbogen RG, et al: Detection of titanium in human tissues after craniofacial surgery. Plast Reconstr Surg 1997;99:976-979
DOI
|
3 |
McManners J, Moos KF, El-Attar A: The use of biodegradable fixation in sagittal split and vertical subsigmoid osteotomy of the mandible: a preliminary report. Br J Oral Maxillofac Surg 1997;35: 401-405
DOI
ScienceOn
|
4 |
Kallela I, Tulamo RM, Hietanen J, et al: Fixation of mandibular body osteotomies using biodegradable amorphous self-reinforced (70L:30DL) polylactide or metal lag screws: an experimental study in sheep. J Craniomaxillofac Surg 1999;27:124-133
DOI
ScienceOn
|
5 |
Edwards RC, Kiely KD, Eppley BL: Fixation of bimaxillary osteotomies with resorbable plates and screws: experience in 20 consecutive cases. J Oral Maxillofac Surg 2001;59:271-276
DOI
ScienceOn
|
6 |
Shand JM, Heggie AAC: Use of a resorbable fixation system in orthognathic surgery. Br J Oral Maxillofac Surg 2000;38(4):335-337
DOI
ScienceOn
|
7 |
Messer EJ, Hayes DC, Bitbe PJ: Use of intraosseous metal appliances in fixation of mandibular fractures. J Oral Surg 1967;25:493
|
8 |
Haers PE, Sailer HF: Biodegradable self-reinforced poly-L/DLlactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures. J Craniomaxillofac Surg 1998;26:363-372
DOI
|
9 |
Kumar AV, Staffenberg DA, Petronio JA, et al: Bioabsorbable plates and screws in pediatric craniofacial surgery: a review of 22 cases. J Craniofac Surg 1997;8:97-99
DOI
ScienceOn
|
10 |
Ylikontiola L, Sundqvuist K, Sandor GKB, et al: Self-reinforced Bioresorbable poly-L / DL-Lactide (SR-P(L / DL)LA) 70 / 30 miniplates and miniscrews are reliable for fixation of anterior mandibular fractures: A pilot study. Oral Sur Oral Med Oral Pathol 2004;97:312-317
DOI
ScienceOn
|
11 |
Suuronen R, Manninen MJ, Pohjonen T, et al: Mandibular osteotomy fixed with biodegradable plates and screws: an animal study. Br J Oral Maxillofac Surg 1997;35:341-348
DOI
ScienceOn
|
12 |
Steiner M, Von Fraunhofer JA, Mascaro J: The possible role of corrosion in inhibiting the healing of a mandibular fracture : report of a case. J Oral Surg 1981;39:140
|
13 |
Shand JM, Heggie AA: Use of a resorbable fixation system in orthognathic surgery. Br J Oral Maxillofac Surg 2000;38:335-337
DOI
ScienceOn
|
14 |
Peltoniemi H, Ashammakhi N, Kontio R, et al: The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery. Oral Sur Oral Med Oral Pathol 2002;94:5-14
DOI
ScienceOn
|
15 |
Kim IH, Yi CK: architectural and structural craniofacial analysis of Korean adults. J Kor Oral Maxillofac Surg 1991;17(4):33-44
|
16 |
Iizuka T, Lindqvist C: Rigid internal fixation of mandibular fractures. An analysis of 270 fractures using the AO/ASIF method. Int J Oral Maxillofac Surg 1992;21:65-69
DOI
ScienceOn
|
17 |
Mazzonetto R, Paza AO, Spagnoli DB: A retrospective evaluation of rigid fixation in orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polyactide. Int J Oral Maxillofac Surg 2004;33:664-669
DOI
ScienceOn
|
18 |
Haers PE, Suuronen R, Lindqvist C, et al: Biodegradable polylactide plates and screws in orthognathic surgery: technical note. J Craniomaxillofac Surg 1998;26(2):87-91
DOI
ScienceOn
|
19 |
Bago-Granell J et al: Malignant fibrous histiocytoma of bone at the site of a total hip arthroplasty. J Bone Joint Surg 1984;66B:38
|
20 |
Kallela I, Laine P, Suuronen R, et al: Skeletal stability following mandibular advancement and rigid fixation with polylactide biodegradable screws. Int J Oral Maxillofac Surg 1998;27:3-8
DOI
ScienceOn
|
21 |
Turvey TA, Bell RB, Tejera TJ, et al: The use of self-reinforced biodegradable bone plates and screws in orthognathic surgery. J Oral Maxillofac Surg 2002;60(1):59-65
DOI
ScienceOn
|
22 |
Bouwman JP, Tuinzing DB, Kostense PJ: A Comparative in vitro study on fixation of sagittal split osteotoies with Wurzburg screws, Champy miniplates, and Biofix (biodegradable) rods. Int J Oral Maxillofac Surg 1994;23:46
|
23 |
Cheung LK, Chow LK, Chiu WK: A randomized trial of resorbable versus titanium fixation for orthognathic surgery. Oral Sur Oral Med Oral Pathol Oral Radio Endod 2004;98:386-397
DOI
ScienceOn
|
24 |
Yerit KC, Hainich S, Enislidis G, et al: Biodegradable fixation of mandibular fractures in children: Stability and early results. Oral Sur Oral Med Oral Pathol Oral Radiol Endod 2005;100:17-24
DOI
ScienceOn
|
25 |
Wright JK, Axon HJ: Electrolysis and stainless steel in bone. J Bone Joint Surg 1956;38B:745
|
26 |
Kulkarni RK, Pani KC, Neuman C, et al: Polylactic acid for surgical implants. Arch Surg 1966;93:839-43
DOI
ScienceOn
|
27 |
Turvey TA, Bell RB, Tejera TJ, et al: The use of selfreinforced biodegradable bone plates and screws in orthognathic surgery. J Oral Maxillofac Surg 2002;60:59-65
DOI
ScienceOn
|
28 |
Delaire J, Schendel SA, Tulasne JF: An architectural and structural craniofacial analysis: a new lateral cephalometric analysis. Oral Surg 1981;52:226
DOI
ScienceOn
|
29 |
Kim YK, Yeo Hh, Lim SC: Tissue response to titanium plates: a transmitted electron microscopic study. J Oral Maxillofac Surg 1997;55:322-326
DOI
ScienceOn
|
30 |
Park HS, Cha IH, Park HR: A study on accuracy of maxillary repositioning by external measuring techique. J Kor Maxillofac Plast Reconstr Surg 1991;13:44-51
|