• 제목/요약/키워드: Bone screw

검색결과 437건 처리시간 0.029초

골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석 (PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT)

  • 김영일;정재헌;조규종
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

다수의 임플란트발거로 임플란트 고정성 보철이 실패한 환자에서의 잔존 임플란트를 이용한 부분 가철성 국소의치 수복증례 (Case report: Application of Implant Supported Removable Partial Denture due to Multiple Dental Implant Loss of the Fixed Implant Supported Prosthesis)

  • 강정경;남기훈
    • 대한심미치과학회지
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2014
  • 부분 무치악을 수복하는 데 있어서 선택할 수 있는 치료의 옵션으로는 전통적인 국소의치와 임플란트 지지-고정성 보철물 등이 있다. 하지만, 환자의 전신적 또는 구강의 상태(수술적인 술식이 제한되는 전신병력, 지지조직의 부족 그리고 골유착에 실패한 임플란트)와 치료비용에 대한 허용 정도에 따라 모든 옵션이 항상 가능한 것은 아니다. 가철성 국소의치는 임플란트 고정성 보철물에 비해 구강위생 관리 및 상,하악 악간관계의 부조화를 수정하기에 편리한 장점이 있다. 최근에는 전략적 위치에 임플란트를 식립하여 기존 악궁 형태에서는 제한되는 국소의치 디자인의 한계를 개선할 수 있는 임플란트지지형 RPD(Implant Supported Removable Partial Denture)가 새로운 방안으로 대두되고 있다. ISRPD는 전략적 위치에 임플란트를 식립하여 역학적인 한계를 극복할 수 있을 뿐 만 아니라 전악의 임플란트지지형 고정성 보철이 제한되는 환자에서 보다 경제적이고 현실적인 보철적 해결책이 될 수 있다. 따라서, RPD를 이용한 보철계획 수립시 전략적 위치에서의 임플란트의 사용은 고전적인 가철성 국소 의치에서보다 유지력과 안정성을 증진시키고 구강위생관리 또한 용이하여 환자의 적응도를 높이는 방안으로 고려될 수 있다. 본 증례는 상악 양측 구치부의 임플란트 고정성 보철,하악의 bar-type overdenture를 사용중이던 59세 남성환자에서 상악 #15i임플란트의 abutment screw fracture와 임플란트의 골유착 실패로 인한 다수 임플란트를 발거 후 남은 #15i,24i,25,26,i의 잔존 임플란트와 #23 자연치를 활용해 상악에 ISRPD를 적용한 경우이다. #23 surveyed crown, #24i=25i=26i surveyed bridge 및 #15i에 gold coping을 제작하여 국소의치의 지지와 유지,안정을 도모하였다.최종 보철물을 장착하고 2년간 주기적인 follow up 통해 예후를 관찰중이며 지대치로 사용한 임플란트에서 screw loosening이나 파절, 골흡수 등의 증상은 현재까지 관찰되지 않았다.

미니플레이트의 골내 고정원 적용 시 초기 안정성에 영향을 주는 요인에 대한 3차원 유한요소법적 연구 (Factors influencing primary stability of miniplate anchorage: a three-dimensional finite element analysis)

  • 이남기;최동순;장인산;차봉근
    • 대한치과교정학회지
    • /
    • 제38권5호
    • /
    • pp.304-313
    • /
    • 2008
  • 본 연구는 골내 고정원으로 사용하는 미니플레이트 시스템의 초기 안정성에 영향을 주는 요인에 대해 알아보기 위해 시행하였다. 미니플레이트의 고정에 사용되는 미니스크류의 길이, 수 및 적용되는 교정력의 방향에 따른 골내 응력 분포 양상과 미니스크류의 변위 정도를 분석하기 위하여 3차원 유한요소분석을 시행하였다. 단순화한 골 모델에 6 hole의 곡선형 미니플레이트를 위치하고 직경 2 mm의 미니스크류로 고정하되 각각 6 mm와 4 mm 길이의 두 가지 종류로 세 개 또는 두 개로 고정한 총 네 개의 유한요소모델을 제작한 후 각각의 모델에서 4 N의 교정력을 미니플레이트의 고정되지 않은(unfixed) 가장 원심측 두개의 hole을 연결한 가상의 축에 대해 $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$ 방향으로 각각 적용하였다. 미니플레이트를 고정하는 미니스크류가 동일 길이일 경우 개수가 작을수록, 동일 개수일 경우 길이가 짧을수록 골에 나타나는 최대 응력과 미니스크류의 최대 변위가 증가되었다. 골에 나타나는 최대 응력은 해면골에 비해 피질골에 집중되어 응력의 대부분은 피질골에서 흡수되었다. 미니플레이트의 가상의 축에 대해 교정력의 견인 방향이 증가할수록 골내의 최대 응력과 미니스크류의 최대 변위가 증가되었다. 골내의 최대 응력과 미니스크류의 최대 변위는 적용된 견인력 지점에서 가장 가까운 미니스크류 고정 부위였다. 이상의 결과로 미니플레이트 시스템의 초기 안정성을 위해 2 mm 직경의 미니스크류를 사용 시 4 mm 보다는 6 mm 길이의 미니스크류를, 2개보다는 3개 식립하는 것이 더 유리하며, 미니플레이트의 가상의 축에 대해 적용하는 교정력의 견인방향이 가급적 일치되도록 미니플레이트를 위치시키는 것이 좋을 것으로 생각된다.

임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구 (Study of the re-osseointegration of implant fixture after mechanical unscrewing)

  • 장지훈;조진현;이청희
    • 대한치과보철학회지
    • /
    • 제48권3호
    • /
    • pp.209-214
    • /
    • 2010
  • 연구 목적: 본 연구의 목적은 골 유착된 임플란트에 인위적 비틀림을 가한 후 골 유착이 다시 일어나는지, 혹은 일어나지 않는지, 일어난다면 이전의 골유착보다 강화되는지, 약화되는지에 대해 알아보기 위함이다. 연구 재료 및 방법:상업적으로 순수한 티타늄 (commercial pure titanium 99%)으로 직경 3.75 mm, 길이 4 mm의 표면처리 없는 실험용 임플란트를 제작하였다. 3.0 kg이상의 뉴질랜드산 흰색 암컷 토끼 7마리의 좌우 경골에 제작한 임플란트를 2개씩 식립 후, 6주의 골유착 유도 기간 부여 후 비틀림 제거력을 측정한 경우를 I군으로, 다시 임플란트 고정체를 재위치시키고 봉합하여 4주간의 치유기간을 더 두고 측정한 경우를 II군으로 분류하였다. 광학현미경을 이용한 조직 형태학적 분석을 위하여, 1차 비틀림 제거력 측정 직후 1마리의 토끼를 희생시키고, 2차 비틀림 제거력 측정 직후 2마리의 토끼를 희생시켜 각각 4개, 7개의 시편을 제작하여, 광학현미경 (${\times}20$) 분석에서 골-임플란트 접촉 (Bone-Implant contact, BIC, %)비율과 치밀골 부위에 위치하는 임플란트의 나사산 수를 측정하여 CBa (Bone area in the cortical passage)비율을 측정하였다. 비틀림 제거력과 BIC및 CBa비율에서의 I군과 II군의 통계적 유의성 ($\alpha$=.05)을 평가하였다. 결과: 비틀림 제거력 측정에서 I군은 $10.8{\pm}3.6$ NCm로 측정되었으며, II군은 $20.2{\pm}9.7$ NCm로 측정되었으며, I군보다II군의 비틀림 제거력이 평균 98.1% 증가되었다 (P<.05). 조직 형태학적 분석에서 BIC와 CBa 비율은 I군과 II군 사이에 통계적 유의성을 나타내지 않았고 (P>.05), RT/BIC와 RT/CBa 값은 I군과 II군 사이에 통계적 유의성을 나타냈다 (P<.05). 결론: 임플란트 고정체에 의원성 비틀림 동요가 발생한 경우에 초기 골유착을 얻기 위해 필요로 했던 치유기간보다 짧은 기간 내에 이전보다 견고한 골유착을 얻을 수 있을 것으로 생각된다.

자가 골-슬개건-골을 이용한 관절경적 전방십자인대 재건술의 수술 중 및 수술 후 합병증 (Intraoperative and Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft)

  • 김경태;이송;정순영;김현수;박준성
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.1-6
    • /
    • 2002
  • 목적 : 자가 골-슬개건-골을 이용한 관절경적 전방십자인대 재건술시 발생하는 수술 중 및 수술 후 합병증을 비교 분석하여 그 발생 빈도와 원인 등을 규명하고자 하였다. 대상 및 방법 : 자가 골-슬개건-골을 이용하여 관절경적 전방십자인대 재건술을 시행하고 1년 이상 추시가 가능했던 85예를 대상으로 하였다. 수술 중 발생한 합병증은 발견 즉시 기록 후 교정하고자 하였으며 수술 후 합병증은 최종 추시 기간에 따라 수술 후 1년에서 2년 사이(I군), 2년에서 3년 사이(II군), 3년 이상(III군)의 3군으로 나누어 비교 분석하였다. 결과 : 수술 중 발생한 합병증은 슬개골 골절 1예, 채취한 이식건의 오염 1예, 이식건의 충돌 2예, 대퇴터널 후방 피질골 골절 1예, 간섭나사의 관절강내 후퇴가 1예였다. 수술 후 최종 추시 시 남아있던 합병증을 추시 기간에 따라 비교 분석한 결과, 슬개골 주위 합병증 중 슬관절 전방부 동통, 이식건 공여부 동통 및 슬개골 주위 탄발음은 I군과 II군, I군과 III군간의 비교에서는 각각 유의한 감소를 보였으나, II군과 III군간에는 유의한 차이가 없었다. 관절운동 제한과 피부 절개부위의 감각이상은 3군간에 모두 유의한 차이가 없었다. 결론 : 자가 골-슬개건-골을 이용한 전방 십자인대 재건술 시 발생한 수술 중 합병증은 수술 수기의 부정확 및 수술 팀의 부주의 등으로 발생하는 것으로 수술 수기의 향상과 경험의 누적 등으로 예방이 가능한 것으로 생각되며 수술 후 발생한 슬개 대퇴관절 주위의 합병증은 어느 정도 불가피한 면이 있으나 시간 경과에 따라 점차 호전되는 양상도 보이는 바 이식건의 선택 시 참고하여야 할 것으로 사료된다.

  • PDF

분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구 (Effects of surface treatment on the osseointegration potential of orthodontic mini-implant)

  • 전미선;강윤구;모성서;이근혜;국윤아;김성훈
    • 대한치과교정학회지
    • /
    • 제38권5호
    • /
    • pp.328-336
    • /
    • 2008
  • 본 연구에서는 교정 치료 시 골내 고정원으로 사용되는 교정용 임플랜트의 표면처리 여부가 골유착능에 있어서 어떠한 효과를 보이는지 제거회전력의 측정을 통해 알아보고자 하였으며, 그에 따른 교정력 적용의 확장과 임상적 의의를 알아보고자 하였다. 실험군은 분사처리 후 산부식(Sand-blasted Large grit, and Acid etched, SLA) 표면 처리된 교정용 미니 임플랜트인 C-implant (Cimplant, Seoul, Korea)를 사용하였으며 대조군은 같은 디자인이지만 표면 처리를 하지 않은 평활면 C-implant를 사용하였다. 실험군과 대조군을 각각 2개씩 11마리의 가토 경골에 식립하였고 식립 후 6주에 가토를 희생시켜 제거회전력을 측정하여 t-test를 통하여 두 군의 제거회전력 차이의 통계적 유의성을 알아보았으며 조직표본을 만들어 조직소견을 관찰하였다. 실험결과 제거회전력은 SLA 처리한 C-implant 군이 평활면 C-implant 군보다 통계적으로 유의성 있게 높은 결과를 보였다 (p < 0.05). 평활면 C-implant 군의 평균 제거회전력 값은 4.614 Ncm이고, SLA C-implant 군의 평균 제거회전력 값은 6.286 Ncm로, SLA 군이 평활면 군보다 73% 더 높은 제거회전력에 대한 저항성을 나타내었다. 이상의 연구 결과에서 SLA표면처리가 C-implant의 골유착능을 증가시켰음을 알 수 있었다. 따라서 표면 처리된 교정용 미니 임플랜트는 기존의 임플랜트에 비해 좀 더 강한 힘에 저항할 수 있으며 탈락률을 낮출 수 있을 것으로 생각된다.

전위성 관절내 종골 골절에서 최소 침습적 족근동 도달법 및 압박나사 내고정술을 이용한 수술적 치료 (The Operative Treatment using Mini-open Sinus Tarsi Approach for Displaced Intraarticular Calcaneal Fractures)

  • 김용민;조병기;손현철;박지강;정호승
    • 대한족부족관절학회지
    • /
    • 제16권4호
    • /
    • pp.247-256
    • /
    • 2012
  • Purpose: This study was performed to evaluate the clinical outcomes of operative treatment using mini-open sinus tarsi approach for displaced intraarticular calcaneal fractures. Materials and Methods: We studied 18 cases (16 patients) of intraarticular calcaneal fractures who were treated with sinus tarsi approach by same surgeon. The mean age of patients was 44.8 years, and mean follow-up period was 17.2 months. The measurement of B$\ddot{o}$hler angle, Gissane angle, the degree of articular surface depression, and the period to union were performed through preoperative and postoperative radiographs. The clinical evaluation was performed according to hindfoot score of the American Orthopaedic Foot and Ankle Society (AOFAS) and scale of the Creighton-Nebraska health foundation (CNHF). Results: B$\ddot{o}$hler angle and Gissane angle had improved significantly from preoperative average $9.8^{\circ}$, $117.6^{\circ}$to average $22.4^{\circ}$, $113.4^{\circ}$ immediate postoperatively, and had maintained to average $21.8^{\circ}$and $114.2^{\circ}$ at the last follow-up. The degree of articular surface depression had improved significantly from preoperative average 5.2 mm to 1.2 mm at the last follow-up. All cases achieved bone union, and the period to union was average 10.5 weeks. AOFAS score was average 86.2 points at the last follow-up. There were 7 excellent, 9 good, and 2 fair results according to the CNHF scale. Therefore, 16 cases (88.8%) achieved satisfactory results. Conclusion: The minimally invasive sinus tarsi approach using headless compression screw seems to be an effective surgical method for displaced intraarticular calcaneal fractures, because of the possibility of accurate restoration of articular surface and the low risk of postoperative soft tissue complications.

티타늄과 탄소 섬유 강화 PEEK로 구성된 요추 유합술용 연결봉의 의공학적 영향에 대한 비교 분석 (Comparative Analysis of Biomechanical Behaviors on Lumbar with Titanium and Carbon Fiber Reinforced PEEK Connecting Rods for Fusion Surgery)

  • 서혜성;강해성;전흥재
    • Composites Research
    • /
    • 제34권3호
    • /
    • pp.186-191
    • /
    • 2021
  • 요추에 퇴행이 발생하였을 때 이를 치료하기 위해 요추 유합술이 시행된다. 유합술은 척추체 사이의 추간판을 제거하고 뼈 그래프트 등을 삽입하여 굳혀 하나 이상의 분절을 완전히 고정시켜 척추의 안정성을 복원한다. 둘 이상의 척추체가 단단히 유합될 수 있게끔 척추체를 고정하는 수단으로 척추경 나사못과 연결봉이 환자의 체내에 삽입된다. 본 연구에서는 중증 요추 퇴행성 질환의 치료에 쓰이는 척추 유합술에서 사용하는 척추경 나사못 구조물이 적용된 총 7개의 환자 맞춤형 요추 유한 요소 모델을 생성하였다. 생성한 모델에 각각 티타늄과 CFR-PEEK로 구성된 연결봉을 구성하였다. 척추의 4가지 대표적 거동에 대해 유한요소해석과 통계적 분석을 진행하여 연결봉의 재질이 척추 상태에 미치는 의공학적 영향을 조사하였다. 인접 분절의 추간판 내 압력과 각 분절의 관절 구동 범위가 의공학적 영향을 확인하기 위한 지표로 사용되었다. 연결봉에 CFR-PEEK를 사용한 경우 Ti 연결봉에 비해 인접 분절의 추간판 내 압력은 감소하였고 각 분절의 관절 구동 범위는 증가하였다. 그러나 모든 하중조건에서 통계학적으로 유의미한 경향성 차이는 관찰되지 않았다.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

임플란트 나사선 경사각과 식립 각도에 따른 3차원 유한요소 응력분석 (Three-dimensional finite element analysis of stress distribution for different implant thread slope and implant angulation)

  • 서영훈;임현필;윤귀덕;윤숙자;방몽숙
    • 대한치과보철학회지
    • /
    • 제51권1호
    • /
    • pp.1-10
    • /
    • 2013
  • 연구 목적: 임플란트 나사선 경사각이 치조골의 응력분포에 미치는 영향을 검토하여 어떤 임플란트가 응력분산에 유리한 지 알아보고자 하였다. 연구 재료 및 방법: 피치는 0.8 mm로 일정하게 하고 나사선의 줄(thread) 수를 다르게 하여 나사선 경사각의 변화를 준 1줄 나사선 임플란트(single thread type: 경사각 $3.8^{\circ}$)와 2줄 나사선 임플란트(double thread type: 경사각 $7.7^{\circ}$) 그리고 3줄 나사선 임플란트(triple thread type: 경사각 $11.5^{\circ}$)의 세 가지 모델을 통해 3차원 유한요소 응력분석을 시행하였다. 임플란트가 치조골의 치아 장축에 대하여 $0^{\circ}$, $10^{\circ}$, $15^{\circ}$ 경사지게 식립된 것으로 가정하여 9 가지 모델을 만들었다. 200 N의 수직 방향의 하중과, 200 N의 임의의 $15^{\circ}$ 경사 하중을 가한 경우에 임플란트와 치조골에서 발생된 응력분포를 3차원 유한요소법으로 분석하였다. 결과:1. 임플란트의 경사 식립 각도가 클수록 치조골과 임플란트의 등가응력(von-Mises stress)과 최대주응력이 높게 나타났다. 2. 수직하중보다 경사하중을 가할 경우 치조골과 임플란트의 등가응력과 최대주응력이 높게 나타났다. 3. 임플란트의 나사선 줄 수가 증가할수록 응력분산 효과가 커서 등가응력과 최대주응력의 크기가 감소되었다. 4. 치조골에 작용하는 최대주응력의 크기는 수직하중 시에나 경사하중 시에 3줄 나사선을 가진 임플란트가 가장 작고 다음으로 2줄 또는 1줄 나사선의 순으로 나타나 3줄 나사선의 경우가 가장 우수한 결과를 보였다. 결론: 이상의 결과는 3줄 나사선 임플란트가 1줄 및 2줄 나사선 임틀란트보다 응력분산 효과 면에서 우수하며, $10^{\circ}$ 이상 경사지게 식립된 경우에라도 나사선 경사각이 커지면서 줄 수가 증가할수록 치조골에서 발생하는 최대 주응력 값이 감소하므로 임플란트 나사선 줄 수와 경사각을 최적화함으로써 임플란트 응력분산에 도움이 될 수 있음을 시사하였다.