• Title/Summary/Keyword: Bone screw

Search Result 437, Processing Time 0.023 seconds

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Treatment of Osteochonritis Dissecans of Femoral Condyle (대퇴골과 박리성 골연골염의 치료)

  • Lee Dong-Chul;Kwon Soon;Son Wook-Jin
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.49-54
    • /
    • 2002
  • Purpose : To analyze the clinical results of treatment for the osteochondritis dissecans of femoral condyle by age, the type of lesion and method of treatment. Methods : From March 1991 to February 2000, 17 patients (20 cases) with osteochondritis dissecans of the femoral condyle were followed up over 1 year. Three patients had bilateral lesion. There were 12 cases with trauma history (9 cases with sports injury and 3 cases with direct trauma). The initial symptoms were pain, clicking, locking, giving way in the order of frequency, pain was revealed in all cases. Clinical evaluation of IKDC and Hughston method were used for subjective and objective function. Results : The number of male patient was 12, and the mean age was 19.8 year old (11$\~$50). The location of the lesion was 14 cases in medial femoral condyle and 6 cases in lateral femoral condyle. The arthroscopic findings of the lesion in 15 cases were as follows, early separation in 6 cases, partially detachment in 4 cases, and crators and complete detachment in 5 cases. 5 cases were treated with mutiple drilling and 5 cases with Herbert screw fixation, 3 cases with Herbert screw fixation and bone graft. In early stage, 7 cases were treated with conservative method. In the grading of Hughston score, 6 cases were graded as excellent, 9 cases as good, 15 cases were graded as good to excellent. Based on the IKDC scale, 1 case was graded as normal, 6 as nearly normal, and 10 as abnormal. Conclusions : The trauma seemed to be important factor in occurrence of osteochondritis dissecans of the femoral condyle. The clinical results of juvenile period showed better than adolescence and adult period, it is necessary to detect the lesion as soon as possible. The result of subjective evaluation was worse than the Hughston evaluation. It was caused by limiting involvement of sports activity and limited activity in the adolescence.

  • PDF

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS ACCORDING TO IMPLANT THREAD DESIGN UNDER THE AXIAL LOAD (수직력하에서 임프란트 나사형태에 따른 응력의 3차원 유한요소법적 분석)

  • Kim, Woo-Taek;Cha, Yong-Doo;Oh, Se-Jong;Park, Sang-Soo;Kim, Hyun-Woo;Park, Yang-Ho;Park, Jun-Woo;Rhee, Gun-Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.2
    • /
    • pp.111-117
    • /
    • 2001
  • There are three designs of thread form in screw type implants: V-thread, Reverse buttress thread and Square thread. The purpose of this study was to find out how thread form designs have an influence on the equivalent stress, equivalent strain, maximum shear stress and maximum shear strain and which design of thread form generates more maximum equivalent stress and strain. 3-D finite element analysis was used to evaluate the stress and strain patterns of three tread types. The results of this study were as follow. 1. Under the 200N of axial load, the value of maximum equivalent stress is smallest in square thread and there is no significant difference between that of V thread and reverse buttress thread. 2. Under the 200N of axial load, the value of maximum equivalent strain is largest in V thread and smallest in square thread. 3. Under the 200N of axial load, the value of maximum shear stress is smallest in square thread and there is no significant difference between that of V thread and reverse buttress thread. 4. Under the 200N of axial load, the value of maximum equivalent strain is largest in V thread and there is no significant difference between that of square thread and reverse buttress thread. 5. Above results show that the square thread has special advantages in stress and strain compared with other thread types, especially in shear stess which is most determinant to implant-bone interface. Considering the superior biomechanical properties of square form implant, we presume that square form implant has better clinical results than the other types of implants in the same clinical conditions.

  • PDF

Simultaneous Reduction of Contralateral Malar Complex in Cases of Unilateral Zygoma Bone Fracture (편측 관골 골절에서 동시 반대측 관골 축소술)

  • Kim, Peter Chan-Woo;Lee, Byung-Kwon;Bae, Ji-Suk
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.851-860
    • /
    • 2011
  • Purpose: Reduction by simply assembling bones is recognized as treatment for a zygoma fracture. However, in patients who originally had a protruding zygoma, the fractured parts look like malarplasty after the edema subsides, giving a soft impression which patients notice. Thus, we created symmetry through simultaneous contralateral malar reduction in a unilateral zygoma fracture. Methods: In this study, the patients who had surgery between July, 2008 and December, 2009 with admission were object. In 76 patients with a zygoma fracture, the patients with bilateral zygoma fractures were excluded. Among 48 patients who had a reduction only after a unilateral zygoma fracture, the patients hoping for a reduction of their rough protruding zygoma were analyzed with front cephalometry. The study progressed on 22 patients who had simultaneous contralateral malar reduction in a unilateral zygoma fracture with consent. After fixing the fracture, we did a straight zygoma osteotomy through a 1.5 cm intraoral incision. After that, we created symmetry with a special ruler and fixed the broken zygomatic arch with a screw and plate. We evaluated the facial index and satisfaction with a statistical analysis before and after the surgery. Results: In 22 patients, there was no reoperation except for 1 patient who had a zygoma fracture. None of the patients were treated for infection or hematoma. Two patients complained of paresthesia after the malar reduction operation, but this subsided in 4 months. Most of them were satisfied with the malar reduction, especially the women, and we obtained a better mid facial contour with decreased facial width ($p$ <0.05). Conclusion: Existing zygoma fracture surgery focuses on anatomical reduction. However, we need to have a cosmetic viewpoint in fractures as interests of face contour arise. Thus, contralateral malar reduction got a 4.7 (range 0~5) from patients who had malar reduction surgery in our hospital. Although adjusting to all zygoma fractures has limitations, it can be a new method in zygoma fractures when there are limited indications of protruding zygoma and careful attention is given to patients' high demands.

Burnt-out Metastatic Prostate Cancer

  • Shin, Dong Suk;Koo, Dong Hoe;Yoo, Suhyeon;Ju, Deok Yun;Jang, Cheol Min;Joo, Kwan Joong;Shin, Hyun Chul;Chae, Seoung Wan
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.116-119
    • /
    • 2013
  • A burnt-out prostate cancer tumor is a very rare clinical entity. The term 'burnt-out' refers to a primary tumor that has spontaneously and nearly completely regressed without treatment. Since metastasis of prostate cancer is usually encountered in the presence of advanced disease, distant metastasis with an undetectable primary tumor is very rare. We report herein a case of a burnt-out prostate cancer tumor that metastasized to the thoracic (T) spine and caused cord compression. A 66-year-old man visited the Emergency Department due to weakness of both legs for the past two days. His blood and urine tests were normal at the time. His spine magnetic resonance imaging (MRI) scans looked like bone metastasis that involved the T-7 vertebral body and a posterior element, and caused spinal cord compression. Other images, including from the brain MRI, neck/chest/abdomino-pelvic computed tomography (CT) scan and 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) and endoscopy, revealed no lesions that suggested malignancy. After total corpectomy T-7 and screw fixation/fusion at T5 to T10, the pathology report revealed a metastatic carcinoma that was strongly positive for prostate-specific antigen (PSA). The serum PSA value was 1.5 ng/mL. The transrectal 12-core prostate biopsy and ultrasonography showed no definitive hypoechoic lesion, but one specimen had slight (only 1%) adenocarcinoma with a Gleason score of 6 (3+3). The final diagnosis was burned-out prostate cancer with an initial normal PSA value. Although metastatic disease with an unknown primary origin was confirmed, a more aggressive approach in seeking the primary origin could provide a more specific treatment strategy and greater clinical benefit to patients.

The Safety and Efficacy of Cadaveric Allografts and Titanium Cage as a Fusion Substitutes in Pyogenic Osteomyelitis

  • Kim, Hyun-Woo;Ryu, Je-Il;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.348-356
    • /
    • 2011
  • Objective : The safety and efficacy of various fusion substitutes in pyogenic osteomyelitis has not been investigated. We evaluated and compared the cadaveric allograft and titanium cages used to reconstruct, maintain alignment and achieve fusion in the management of pyogenic spinal infection. Methods : There were 33 patients with pyogenic osteomyelitis underwent fusion in this study. Fifteen of the 33 patients were operated on by fusion with allografts (cadaveric patella bones) and 18 of those were operated with titanium mesh cages filled with autologous cancellous iliac bone. After the affected disc and vertebral body resection with pus drainage, cadaveric allograft or titanium cages were inserted into the resected space. Posterior transpedicular screw fixation and rod compression in resected space, where cadaveric allograft or titanium cages were inserted, was performed to prevent the malposition in all patients except in 1 case. Recurrent infection was identified by serial erythrocyte sedimentation rate and cross reactive protein follow-up. Osseous union and recurred infection available at a minimum of 2 years following operation was identified. The amount of kyphosis correction and the subsidence were measured radiographically. Results : Spinal fusion was achieved in 29 of 33 patients. In the cadaveric allograft group, 93.3% of patient (14 of 15) showed the osseous union while 83.3% of patient (15 of 18) in the titanium cage group showed union. Subsidence was noted in 12 of the patients. Twelve patients (36.3%) showed unsettling amounts of subsidence postoperatively whereas 46.6% of patients in the cadaveric allograft group and 37.7% of patients in the titanium cage group showed similar subsidence, respectively. There were statistical difference in the fusion rate (p=0.397) and subsidence rate (p=0.276) between the two groups. There was significant statistical difference in the postoperative improvement of segmental kyphosis between the two groups (p=0.022), that is the improvement in sagittal alignment was greater in the titanium cage group than in the cadaveric allograft group. There was no case of recurred infection. Conclusion : The cadaveric allograft and titanium cages are effective and safe in restoring and maintaining sagittal plane alignment without increased incidence in infection recurrence in pyogenic osteomyelitis. The postoperative improvement of segmental kyphosis was better in the cage group.

Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report (Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례)

  • Hong, Jun-Tae;Choi, Yu-Sung;Han, Se-Jin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.253-268
    • /
    • 2012
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption, since this includes the gingival area and restricts the position of the implants. however, hard- and soft-tissue grafting may allow the implants to be placed into the desired position. Although it is possible to regenerate lost tissues, an alternative is to use fixed detachable prostheses that restore the function and the esthetics of the gingiva and teeth. Various material combinations including metal/acrylic, metal/ceramic, and zirconia/ceramic have been used for constructing this type of restoration. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. With virtually unbreakable, chip-proof, life-like nature, monolithic zirconia frameworks can prospectively replace other framework materials. This clinical report describes the restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with dental implants. The occluding surfaces were made of monolithic zirconia, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Retrospective Study of Sandblasted, Large-grit and Acid-etched Implant (Sandblasted, Large-grit and Acid-etched Implant에 대한 후향적 임상 연구)

  • Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Park, Jin-Ju;Jung, Jong-Won;Yoon, Dae-Woong;Yang, Seong-Su;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.352-358
    • /
    • 2011
  • Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

A photoelastic Stress Analysis of Implant Prosthesis According to Fitness of Super structure (불량 적합 임플란트 보철물의 광탄성 응력 분석)

  • Lim, Hyun-Pil;Heo, Shin-Ok;Kim, Hong-Joo;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • To assess the stress distribution of implant prosthesis induced by intentional misfit using photoelastic model. Stress was measured at the surrounding bone after applying vertical load to the implant. Three implants were placed in each of three photoelastic resin blocks. No misfits were used for the control group, while for the experimental group $100{\mu}m$ misfit after cutting the crown was used. The photoelastic stress analysis was performed. In control group, stress concentration was not shown when the load was not applied, whereas stress concentration was shown only in the loaded part even when load was applied and the stress was distributed in anterior-posterior direction when applying a load in the middle. When intentional misfits were given, stress around the fixture was incurred when tightening the screw even if load was not applied. If the load was applied, stress was concentrated around the implants including areas where the load was applied. In particular, the prosthesis made of UCLA showed more stress concentration as compared with a conical abutment. In the UCLA case, concentration was shown from the apex following through the axis to the cervical area. Prosthesis with misfit makes the stress concentrated though the load was not applied and it induces even more severe stress concentration when the load was applied. This founding demonstrates the importance of the correct prosthesis production.