• 제목/요약/키워드: Bone contact

검색결과 379건 처리시간 0.03초

HA, TPS 및 $Al_2O_3$ 인공치근 매식체의 조직반응에 관한 실험적 연구 (EXPERIMENTAL STUDIES ON THE TISSUE RESPONSE OF HA COATED, TPS AND $Al_2O_3$ ARTIFICIAL ROOT IMPLANTS)

  • 김선영;김영수
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.267-284
    • /
    • 1991
  • Since the concept of a direct contact between bone and implants, without interposed soft- tissue layers, was reported by Dr. $Br{\aa}nemark$, there has been increasing necessity for correct under-standing of bone-implant interface and surrounding tissue response. Beside quality of bone, surgical technique, load applied to implants, one must consider implant materials, design and surface characteristics to obtain osseointegration. In this study HA plasma-sprayed implants, TPS implants and $Al_2O_3$ implants were inserted into the alveolar bone of dog and tissue response was observed with radiograph, stereoscope, light microscope, and scanning electron microscope. Results were as follows : 1. There was rapid and active bone formation in the region adjacent to HA plasma-sprayed implants but in the deep supporting bone only slight bone formation was seen. 2. There was considerable lamella bone formation in the region adjacent to TPS implants and the deep supporting bone became more compact. 3. There was some gap and sclerosing bone formation in the adjacent region of $Al_2O_3$ implants, but there was irregular new bone formation in the deep supporting bone. Therefore, it seems that $Al_2O_3$ is not adequate for osseointegrated implants.

  • PDF

부분 무치악의 고정성 임플랜트 보철의 저위교합에 관한 3차원 유한요소법적 연구 (3-DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE INFRAOCCLUSION OF FIXED IMPLANT PROSTHESIS FOR PARTIAL EDENTULISM)

  • 김인섭;최충국;정재헌
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.632-649
    • /
    • 1996
  • The purpose of this study was to examine, by the method of 3-dimentional finite element analysis. how infraocclusion affected the stress distribution in surrounding bone and osseointegrated prosthesis. The 3-dimentional finite element mandibular models were made, in which the first and second molars were removed and the two osseointegrated implants were placed in the first and second molar sites and implant supported fixed prostheses were constructed. Analysis of equivalent stress and displacement induced by strong occlusion or infraocclusion was performed under vertical or inclined distributed loads. The results were as follows; 1. Under vertical load of 50N or 500N, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. 2. In the model in which infraocclusion of $30{\mu}m$ had been allowed, implant-prosthesis on the molars had no contact with opposing teeth under vertical load of 50N, However with the same allowed infraocclusion and the model under vertical load of 500N, implant prosthesis on the second molar had contact with opposing teeth, and stress distribution occured properly on natural teeth and implants. 3. Under $45^{\circ}$ inclined load, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. There was greater stress in the case of $45^{\circ}$ inclined load than in the case of vertical load. 4. Under $45^{\circ}$ inclined load of 50N or 500N, the model in which infraocclusion of $30{\mu}m$, had been allowed showed no occlusal contact on the implants and occlusal contact on the natural teeth. 5. In partially edentulous cases with implant supported prosthesis, we can prevent excessive load on implants by allowing infraocclusion.

  • PDF

하악골 Malunion에 따른 Transverse Mandibular Deficiency에 대하여 split and Replantation of Corticocancellous Bone Graft를 이용한 외과적 교정술의 증례보고 (Surgical Treatment of Transverse Mandibular Deficiency by using Split and Replantation of Corticocancellous Bone Graft)

  • 김진수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제11권1호
    • /
    • pp.249-254
    • /
    • 1989
  • Transverse mandibular deficiency is rare maxillomandibular malrelationship. Most of this malrelationship is considered to be caused by loss of bone substances. This can be corrected by subapical osteotomy, midsagittal vertical osteotomy, midline horizontal L sliding osteotomy, etc., case by case. In these cases, malrelationship after malunion of mandibular fracture, combination of vertical osteotomy and sliding autogenous cortical bone graft was used and favorable results were obtained. Advantages over previous traditional surgical methods were as follows : 1. This method provided easy access and good visibility. 2. It provided broad bone contact area, thus no other operation to obtain bone graft was needed. 3. There were little circumstances to extract teeth. 4. There were no difficulty in tongue movement after operation.

  • PDF

치조골 높이가 다른 2개 임플란트 금관의 고정연결 조건에 따른 응력분석 (Stress Analysis on the Splinted Conditions of the Two Implant Crowns with the Different Vertical Bone Level)

  • 전창식;정신영;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.169-182
    • /
    • 2005
  • The purpose of this study was to compare the stress distribution around the surrounding bone according to the splinted and non-splinted conditions on the finite element models of the two implant crowns with the different vertical bone level. The finite element model was designed with the parallel placement of the two fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st and 2nd molars. As the bone quality, the inner cancellous bone and the outer 2 mm cortical bone were designed, and the cortical and cancellous bone were assumed to be perfectly bonded to the implant fixture. The splinted model(Model 1) had 2 mm contact surface and the non-splinted model(Model 2) had $8{\mu}m$ gap between two implant crowns. Two group (Splinted and non-splinted) was loaded with 200 N magnitude in the vertical and oblique directions on the loading point position on the central position of the crown, the 2 mm and 4 mm buccal offset point from the central position. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual and mesio-distal sections. The results were as follows; 1. In the vertical loading condition of central position, the stress was distributed on the cortical bone and the cancellous bone around the thread of the fixture in the splinted and non-splinted models. In the oblique loading condition, the stress was concentrated toward the cortical bone of the fixture neck, and the neck portion of 2nd molar in the non-splinted model was concentrated higher than that of 1st molar compared to the splinted model. 2. In the 2 mm buccal offset position of the vertical loading compared to the central vertical loading, stress pattern was shifted from apical third portion of the fixture to upper third portion of that. In the oblique loading condition, the stress was distributed over the fixture-bone interface. 3. In the 4 mm buccal offset position of the vertical loading, stress pattern was concentrated on the cortical bone around the buccal side of the fixture thread and shifted from apical third portion of the fixture to upper third portion of that in the splinted and non-splinted models. In the oblique loading, stresses pattern was distributed to the outer position of the neck portion of the fixture thread on the mesio-distal section in the splinted and non-splinted models. Above the results, it was concluded that the direction of loading condition was a key factor to effect the pattern and magnitude of stress over the surrounding bone of the fixture under the vertical and oblique loading conditions, although the type with or without proximal contact did not effect to the stress distribution.

표면처리가 다른 5종 임플랜트의 안정성에 관한 연구 (A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS)

  • 김선종;신상완;정성민;류재준
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

A histomorphometric study of dental implants with different surface characteristics

  • Pak, Hyun-Soon;Yeo, In-Sung;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.142-147
    • /
    • 2010
  • PURPOSE. One of the major keys to achieve successful osseointegration of the implant is its surface properties. The aim of this study was to investigate the bone response to dental implants with different surface characteristics using the rabbit tibia model. Tricalcium phosphate (TCP) coated, anodic oxidized and turned (control) surfaces were compared. MATERIALS AND METHODS. Seventy two implants were placed in the tibia of eighteen rabbits. Nine rabbits were sacrificed at 3 weeks of healing and the remaining nine were sacrificed at 6 weeks of healing. The bone-to-implant contact (BIC) and the bone volume density (BVD) were assessed by light microscope after 3 and 6 weeks of healing. RESULTS. Statistical analysis showed that no significant differences in the BIC and BVD were observed between the different implant surfaces and the control group at 3 weeks and 6 weeks of healing. Data also suggested that the BVD of all the surfaces showed significant difference at 3 and 6 weeks. CONCLUSION. The present study has showed that osseointegration occurred in all investigated types of surface-treated implants. In the current study all of the threads of the implants were observed to calculate BIC and BVD values (instead of choosing some of the threads from the bone cortex for example), which didn't make BIC or BVD percentage values better than in the control group, therefore the clinical relevance of these results remains to be shown.

비글견 경골에서 임플란트 식립 시 혈소판 농축 혈장이 골형성에 미치는 영향 (The effect of platelet rich plasma in bone formation on implant installation in the tibia of beagle dogs)

  • 국민석;정승곤;심경미;강성수;박홍주;유선열;오희균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.71-77
    • /
    • 2010
  • Introduction: The purpose of this study is to evaluate the effect of platelet rich plasma in bone formation and osseointegration of implant installed in the bone marrow space. Materials and Methods: Five beagle dogs were used as experimental animals. Two implants were installed on each tibia in the dogs. Implants of the control group were installed with no additional graft. Those of the experimental group 1 were installed with autogenous bone graft from the ilium autogenous bone. Platelet rich plasma (PRP) alone was used in experimental group 2 and the mixture of PRP and autogenous bone was used in experimental group 3. The animals were sacrificed at 8 weeks after implantation. The parts of tibia containing implant were harvested and radiographs were taken for radiographic examination. The specimens were prepared for histological examination and histomorphometric analysis of implant-bone contact ratios. Results: 1. All implants showed sufficient osseointegration in the cortical bone radiographically and histologically, but osseointergration in the marrow space was not satisfactory. 2. Histomorphometrically, the implant-bone contact ratios in the bone marrow was sequentially high in the experimental group 3 (autogenous bone + PRP group), group 1 (autogenous bone group), group 2 (PRP group), and control group (non-additive). 3. It was verified that there was statistical significance between two experimental groups (group 1 and 3) and the other groups (group 2 and control group). (P<0.005) 4. However, there was no statistical significance between group 3 and group 1, also group 2 and control group respectively. Conclusion: These results suggest that platelet rich plasma is effective to osseointegration in the implant installation but there is no statistical significance.

Early bone healing onto implant surface treated by fibronectin/oxysterol for cell adhesion/osteogenic differentiation: in vivo experimental study in dogs

  • Lee, Jung-Seok;Yang, Jin-Hyuk;Hong, Ji-Youn;Jung, Ui-Won;Yang, Hyeong-Cheol;Lee, In-Seop;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제44권5호
    • /
    • pp.242-250
    • /
    • 2014
  • Purpose: This study aimed to evaluate the effects of fibronectin and oxysterol immobilized on machined-surface dental implants for the enhancement of cell attachment and osteogenic differentiation, on peri-implant bone healing in the early healing phase using an experimental model in dogs. Methods: Five types of dental implants were installed at a healed alveolar ridge in five dogs: a machined-surface implant (MI), apatite-coated MI (AMI), fibronectin-loaded AMI (FAMI), oxysterol-loaded AMI (OAMI), and sand-blasted, large-grit, acid-etched surface implant (SLAI). A randomly selected unilateral ridge was observed for 2 weeks, and the contralateral ridge for a 4-week period. Histologic and histometric analyses were performed for the bone-to-implant contact proportion (BIC) and bone density around the dental implant surface. Results: Different bone healing patterns were observed according to the type of implant surface 2 weeks after installation; newly formed bone continuously lined the entire surfaces in specimens of the FAMI and SLAI groups, whereas bony trabecula from adjacent bone tissue appeared with minimal new bone lining onto the surface in the MI, AMI, and OAMI groups. Histometric results revealed a significant reduction in the BIC in MI, AMI, and OAMI compared to SLAI, but FAMI demonstrated a comparable BIC with SLAI. Although both the BIC and bone density increased from a 2- to 4-week healing period, bone density showed no significant difference among any of the experimental and control groups. Conclusions: A fibronectin-coated implant surface designed for cell adhesion could increase contact osteogenesis in the early bone healing phase, but an oxysterol-coated implant surface designed for osteoinductivity could not modify early bone healing around implants in normal bone physiology.

의도적으로 연조직에 노출시킨 수산화인회석 코팅 임플란트의 골유착과 안정성에 대한 실험적 연구 (Experimental Study of Osseointegration and Stability of Intentionally Exposed Hydroxyapatite Coating Implants)

  • 정경인;김수관;문성용;오지수;조지호;임형섭;김정선;임성철;정미애
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권1호
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose: The purpose of this study is to evaluate the effect of exposure of hydroxyapatite coating on the amount of bone formation and stability in the dogs. Methods: In this study, hydroxyapatite coated implants (HAPTITE) was placed over the femur bone surface of four dogs about 1 mm. The experimental group was divided into 4 weeks group of 8 implants and 8 weeks group of 8 implants, and then they were sacrificed. The stability of implants was evaluated twice with Osstell$^{TM}$ mentor (Osstell AB, Goteborg, Sweden) at right after placement and sacrifice. The amount of bone formation was evaluated through histomorphometric examination. Results: The stability of implants was in normal range, and tended to increase as time goes by. Mean percentages of new bone formation rates were $90.5{\pm}6.6$ at uppermost 1 mm bone level adjacent to soft tissues (level 1) and $92.9{\pm}4.1$ at next 1 mm bone level (level 2) in 4 weeks group, $90.1{\pm}11.5$ at level 1 and $95.9{\pm}2.3$ at level 2 in 8 weeks group. Mean percentages of bone-implant contact rates were $85.1{\pm}10.8$ at level 1 and $88.1{\pm}13.8$ at level 2 in 4 weeks group, $88.5{\pm}14.4$ at level 1 and $95.3{\pm}3.1$ at level 2 in 8 weeks group. There was no statistically significant difference of new bone formation rate and bone-implant contact rate between uppermost 1 mm bone level adjacent to soft tissues and next 1 mm bone level. However, there was no significant difference in bone formation between 4 and 8 weeks groups. Conclusion: These results suggested that exposed hydroxyapatite coated implants to soft tissue showed favorable bone formation and implant stability.

임플랜트-지대주의 연결방법에 따른 임플랜트 보철의 유한요소 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO CONNECTION TYPES OF IMPLANT-ABUTMENT)

  • 허진경;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.544-561
    • /
    • 2005
  • Purpose : This study was to assess the loading distributing characteristics of implant systems with internal connection or external connection under vertical and inclined loading using finite element analysis. Materials and methods : Two finite element models were designed according to type of internal connection or external connection The crown for mandibular first molar was made using cemented abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the centric cusp tip in a 15$^{\circ}$ inward inclined direction (loading condition B), or 200N at the centric cusp tip in a 30$^{\circ}$ outward inclined direction (loading condition C) respectively. Von Mises stresses were recorded and compared in the supporting bone, fixture, abutment and abutment screw. Results : 1. In comparison with the whole stress or the model 1 and model 2, the stress pattern was shown through th contact of the abutment and the implant fixture in the model 1, while the stress pattern was shown through the abutment screw mainly in the model 2. 2. Without regard to the loading condition, greater stress was taken at the cortical bone, and lower stress was taken at the cancellous bone. The stress taken at the cortical bone was greater at the model 1 than at the model 2, but the stress taken at the cortical bone was much less than the stress taken at the abutment, the implant fixture, and the abutment screw in case of both model 1 and model 2. 3. Without regard to the loading condition, the stress pattern of the abutment was greater at the model 1 than at the model 2. 4. In comparison with the stress distribution of model 1 and model 2, the maximum stress was taken at the abutment in the model 1. while the maximum stress was taken at the abutment screw in the model 2. 5. The magnitude of the maximum stress taken at the supporting bone, the implant fixture, the abutment, and the abutment screw was greater in the order of loading condition A, B and C. Conclusion : The stress distribution pattern of the internal connection system was mostly distributed widely to the lower part along the inner surface of the implant fixture contacting the abutment core through its contact portion because of the intimate contact of the abutment and the implant fixture and so the less stress was taken at the abutment screw, while the abutment screw can be the weakest portion clinically because the greater stress was taken at the abutment screw in case of the external connection system, and therefore the further clinical study about this problem is needed.