• Title/Summary/Keyword: Bone Structure

Search Result 541, Processing Time 0.027 seconds

ENGINEERING GEOLOGICAL STUDIES ON THE SUBMERGED TOMB OF KING MUNMU, SHILLA DYNASTY, KOREA (문무대왕 수증릉에 대한 지질공학적 연구)

  • HoWoongShon;SeongBeomKim
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.139-153
    • /
    • 2003
  • Subsurface information is one of the most important factors in the archaeological excavation. To obtain the information on the underground, geophysical prospecting is becoming a popular method. This study is on the small rocky islands located 200m away from the shoreline of Gampo, Gyeongju city, Korea. According to the historical records and field surveys, it was revealed as the tomb of King Munmu of Shilla Dynasty. However, the questions and debates, such as whether it is really the tomb of King Moonmu or not, and whether it is a buried place or not, are still remains, in addition to the incompletion of precise surveying and scientific studies. The scope of this study contains the researches on the above problems and debates using the geophysical and geological methods and techniques. The rocky islands around the submerged Tomb of King Moonmu is composed of granite, and sag exists inside of the islands. Sea water enters through the east groove by wave and is drained to the west slot by hydraulic gradient, since west slot is 15cm lower than the east. Sag inside of the islands is believed to be extended and widened from pre-existed sinkage by applying tools like chisel in the joints and cracks. It is concluded that the submerged megalith inside of sag was from the rock block which was developed by joints. Geophysical surveys reveal that there is no artificial structure or stone/china/steel chest, under the m egalith and rocky island. Researches show that the tomb of King Moonmu was constructed in the small rocky island artificially. However, the evidences show that planners and constructors of the tomb made every possible effort to preserve the natural environment and condition. It is strongly believed that the megalith was sort of alter to sprinkle bone-ash rather than buried place.

  • PDF

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

A photoelastic Stress Analysis of Implant Prosthesis According to Fitness of Super structure (불량 적합 임플란트 보철물의 광탄성 응력 분석)

  • Lim, Hyun-Pil;Heo, Shin-Ok;Kim, Hong-Joo;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • To assess the stress distribution of implant prosthesis induced by intentional misfit using photoelastic model. Stress was measured at the surrounding bone after applying vertical load to the implant. Three implants were placed in each of three photoelastic resin blocks. No misfits were used for the control group, while for the experimental group $100{\mu}m$ misfit after cutting the crown was used. The photoelastic stress analysis was performed. In control group, stress concentration was not shown when the load was not applied, whereas stress concentration was shown only in the loaded part even when load was applied and the stress was distributed in anterior-posterior direction when applying a load in the middle. When intentional misfits were given, stress around the fixture was incurred when tightening the screw even if load was not applied. If the load was applied, stress was concentrated around the implants including areas where the load was applied. In particular, the prosthesis made of UCLA showed more stress concentration as compared with a conical abutment. In the UCLA case, concentration was shown from the apex following through the axis to the cervical area. Prosthesis with misfit makes the stress concentrated though the load was not applied and it induces even more severe stress concentration when the load was applied. This founding demonstrates the importance of the correct prosthesis production.

Ag Impregnated HAp Coatings on Alumina Substrate by IBAD and Its Biological Test (IBAD를 이용하여 알루미나 위에 HAp를 Coating하는 연구와 이의 항균력 시험)

  • Park, Eui-Seo;Kim, Taik-Nam;Yim, Hyuk-Jun;Kim, Yun-Jong;Hwang, Deuk-Soo;Kim, Jung-Woo;Kim, Sun-Ok
    • The Journal of Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.181-187
    • /
    • 1998
  • Hydroxyapatite was used as implant materials, because it has a good biocompatibility and is similar to human bone. However it is not expected to have a high strength as implant materials because of a low fracture strength after sintering of HAp. Alumina ($\alpha$-alumina) shows a stable chemical properties and high strength in physiological environments. Thus it was tried to use a HAp coatings on Alumina substrate as implant materials. In this study, HAp was coated on Alumina substrate by lon Beam Assisted Deposition(IBAD). Then Ag was impregnated on HAp coating layer, which showed antimicrobial effects. To carry out the ion exchange of $Ag^+$ with $Ca^{2+}$ in HAp on the surface, HAp coated alumina substrate was immersed in 20ppm, 100ppm $AgNO_3$ solution at room temperature for 48 hours. Antimicrobial test was studied by using bacteria, which normally caused periprosthetic infections. The follwing bacteria was used in antimicrobial test. Escherichia coli, Pseudomonas aeruginosa (gram negative) and staphylococcus epidermidis (gram positive). Ag impregnated HAp shows very good antimicrobial effects against these bacteria. The surface structure of sample, which was treated in $AgNO_3$ solution was studied by SEM, XRD. Ag release curve was studied in Simulated Body Fluid (SBF) solution.

  • PDF

Inflammatory Myofibroblastic Tumor of Extremities (사지에 발생한 염증성 근섬유모세포성 종양)

  • Kong, Chang-Bae;Lee, Jeong-Dong;Lee, Jung Uk;Song, Won-Seok;Cho, Wan-Hyeong;Koh, Jae-Soo;Jeon, Dae-Geun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.19 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • Purpose: We analyzed the oncologic characteristics and outcome of patients with inflammatory myofibroblastic tumor of extremities. Materials and Methods: Among the soft tissue tumor patients who were treated between 1999 and 2012, 5 patients who were pathologically confirmed as the inflammatory myofibroblastic tumor of extremities were analyzed retrospectively. Results: There were 1 man and 4 women with mean age of 44 years (37-55 years). The average follow up was 34.6 months (8-87 months). All patients underwent surgical treatment. Only 1 patient had wide resection margin and remaining 4 had marginal (3) or intralesional (1) resection margin. All of 4 patients without wide resection margin developed local recurrence at 10.3 months (8-19 months). Malignant transformation to fibrosarcoma was occurred in 2 patients who developed local recurrence, and 1 patient developed multiple metastases to lung, liver and lymph nodes and expired at 37 months. Three of 5 patients had tumor location abutted to or invasion to major arteries and 1 patient had tumor invading sciatic nerve. Conclusion: It is observed that inflammatory myofibroblastic tumor of extremities is usually located near the major neurovascular structure. Wide resection should be considered as the initial surgical treatment because this tumor showed a high local recurrence rate and possibility of malignant transformation.

Full mouth rehabilitation of the patient with severely worn dentition using monolithic zirconia prosthesis: A clinical report (치아 마모 환자에서 단일 구조 지르코니아를 이용한 완전 구강 회복 증례)

  • Kim, Tae-Yeon;Han, Jung-Suk;Kim, Sung-Hun;Yeo, In-Sung;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.140-145
    • /
    • 2016
  • Excessive occlusal wear causes loss of tooth structure, occlusal plane disharmony, impaired function and esthetic problems. Although the decrease of occlusal vertical dimension may be compensated by the growth of alveolar bone and tooth eruption, minimal increase of occlusal vertical dimension may be required for esthetics and retention of prosthesis. In this case, a 44-year-old male patient visited Seoul National University Dental Hospital with chief complaint of severe tooth wear and shade disharmony. Based on assessment of diagnostic wax-up, 3 mm increase of occlusal vertical dimension was determined. Removable occlusal splint and interim prosthesis was used to ascertain patient's comfort and adaptation. After the adaptation period, definitive prosthesis fabricated with full-contour monolithic zirconia were delivered and the patient was recommended to wear a nightguard device for prosthesis protection. This report presents a case of full mouth rehabilitation with the elevation of patient's occlusal vertical height, resulting in satisfactory esthetics and functions.

A STUDY ON AMALGAM CAVITY FRACTURE WITH THREE DIMENSIONAL FINITE ELEMENT METHOD (아말감 와동의 파절에 관한 3차원 유한요소법적 연구)

  • Kim, Han-Wook;Um, Chung-Moon;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.345-371
    • /
    • 1994
  • Restorative procedures can lead to weakening tooth due to reduction and alteraton of tooth structure. It is essential to prevent fractures to conserve tooth. Among the several parameters in cavity designs, cavity isthmus and depth are very important. In this study, MO amalgam cavity was prepared on maxillary first premolar. Three dimensional. finite element models were made by serial photographic method and cavity depth(1.7mm, 2.4mm) and isthmus (11 4, 1/3, 1/2 of intercuspal distance) were varied. linear, eight and six-nodal, isoparametric brick elements were used for the three dimensional finite element model. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. Three types model(B, G and R model) were developed. B model was assumed perfect bonding between the restoration and cavity wall. Both compressive and tensile forces were distributed directly to the adjacent regions. G model(Gap Distance: 0.000001mm) was assumed the possibility of play at the interface simulated the lack of real bonding between the amalgam and cavity wall (enamel and dentin). When compression occurred along the interface, the forces were transferred to the adjacent regions. However, tensile forces perpendicular to the interface were excluded. R model was assumed non-connection between the restoration and cavity wall. No force was transferred to the adjacent regions. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, von Mises stress, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as follows: 1. G model showed stress and strain patterns between Band R model. 2. B model and G model showed the bending phenomenon in the displacement. 3. R model showed the greatest amount of the displacement of the buccal cusp followed by G and B model in descending order. G model showed the greatest amount of the displacement of the lingual cusp followed by B and R model in descending order. 4. B model showed no change of the displacement as increasing depth and width of the cavity. G and R model showed greater displacement of the buccal cusp as increasing depth and width of the cavity, but no change in the displacement of the lingual cusp. 5. As increasing of the width of the cavity, stress and strain were not changed in B model. Stress and strain were increased on the distal marginal ridge and buccopulpal line angle in G and R model. The possibility of the tooth fracture was increased. 6. As increasing of the depth of the cavity, stress and strain were not changed in B and G model. Stress and strain were increased on the distal marginal ridge and buccopulpal line angle in R model. The possibility of the tooth fracture was increased.

  • PDF

Cost Effective Remote Subscription scheme for Ubiquitous Convergence IP-based Network (유비쿼터스 컨버젼스 IP 기반 대용량 네트워크에서 비용 절감형 리모트-서브스크립션 기법)

  • Shin, Soo-Young;Yoon, Young-Muk;Park, Soo-Hyun
    • The KIPS Transactions:PartC
    • /
    • v.14C no.1 s.111
    • /
    • pp.95-104
    • /
    • 2007
  • Mobile multimedia services such as TV-call or video streaming are gradually becoming popular in the 3rd or more generation mobile network (IMT-2000). Multimedia traffic is expected to continue increasing into the coming years, and IP technology is considered to be the efficient way of transporting such huge volumes of multimedia traffic. IP-based IMT network platform represents an evolution from IMT-2000. The structure of IP-based IMT network as ubiquitous platform is three-layered model : Middleware including Network Control PlatForm (NCPF) and Service Support PlatForm (SSPF), IP-BackBone (IP-BB), access network including sensor network. Mobility Management (MM) architecture in NCPF is proposed for IP-based IMT network in order to manage routing information and location information separately. The generous existing method of multicast control in IP-based IMT network is Remote Subscription. But Remote Subscription has problem that should be reconstructed whole multicast tree when sender in multicast tree moves to another area. To solve this problem, we propose the way to put Multicast-manager in NCPF.

Development and Evaluation of Natural Hydroxyapatite Ceramics Produced by the Heat Treatment of Pig Bones

  • Lim, Ki-Taek;Kim, Jin-Woo;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.227-234
    • /
    • 2014
  • Purpose: The aim of this research was to develop and evaluate natural hydroxyapatite (HA) ceramics produced from the heat treatment of pig bones. Methods: The properties of natural HA ceramics produced from pig bones were assessed in two parts. Firstly, the raw materials were characterized. A temperature of $1,200^{\circ}C$ was chosen as the calcination temperature. Fine bone powders (BPs) were produced via calcinations and a milling process. Sintered BPs were then characterized using field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), energy dispersive X-ray spectroscopy (EDX), Fourier transform infrared (FTIR) spectroscopy, and a 2-year in vitro degradability test. Secondly, an indirect cytotoxicity test was conducted on human osteoblast-like cells, MG63, treated with the BPs. Results: The average particle size of the BPs was $20{\pm}5{\mu}m$. FE-SEM showed a non-uniform distribution of the particle size. The phase obtained from XRD analysis confirmed the structure of HA. Elemental analysis using XRF detected phosphorus (P) and calcium (Ca) with the Ca/P ratio of 1.6. Functional groups examined by FTIR detected phosphate ($PO{_4}^{3-}$), hydroxyl ($OH^-$), and carbonate ($CO{_3}^{2-}$). The EDX, XRF, and FTIR analysis of BPs indicated the absence of organic compounds, which were completely removed after annealing at $1,200^{\circ}C$. The BPs were mostly stable in a simulated body fluid (SBF) solution for 2 years. An indirect cytotoxicity test on natural HA ceramics showed no threat to the cells. Conclusions: In conclusion, the sintering temperature of $1,200^{\circ}C$ affected the microstructure, phase, and biological characteristics of natural HA ceramics consisting of calcium phosphate. The Ca-P-based natural ceramics are bioactive materials with good biocompatibility; our results indicate that the prepared HA ceramics have great potential for agricultural and biological applications.

Hemopoiesis in Human Fetal Spleen (사람 태아 지라에서 혈구형성에 관한 연구)

  • Kim, Dae-Jin;Sim, Kyu-Min;Kim, Sung-Su;Lee, Won-Bok;Kim, Kyung-Yong
    • Applied Microscopy
    • /
    • v.33 no.1
    • /
    • pp.41-48
    • /
    • 2003
  • The hemopoiesis in human fetal spleen was studied with transmission electron microscope. There were undifferentiated proerythroblast, basophilic erythroblast, polychromatophilic erythroblast, and acidophilic erythroblast. Besides, enucleated nuclei and mitoses were present. Groups of erythroblastic cells were surrounded by certain cell. The structure was identical to erythropoietic island found in fetal liver. So, erythropoisis in spleen was developing in a pattern similar to fetal liver. Megakaryobalst were found in spleen, but there was no mature cells, cells in mitosis nor platelet formation. It was not clear whether megakaryoblast in circulation was trapped in spleen or participated in megakaryopoiesis. In summary, erythropoiesis took place in fetal spleen in a pattern similar to fetal liver and bone marrow. But it was not certain whether megakaryopoiesis took place in fetal spleen.