• Title/Summary/Keyword: Bone Plate

Search Result 557, Processing Time 0.021 seconds

Leukocyte platelet-rich fibrin in endodontic microsurgery: a report of 2 cases

  • Mariana Domingos Pires;Jorge N.R. Martins;Abayomi Omokeji Baruwa;Beatriz Pereira;Antonio Ginjeira
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.17.1-17.8
    • /
    • 2022
  • Endodontic microsurgery is a predictable treatment option when orthograde treatment or retreatment is unsuccessful or unfeasible. However, when there is a gross compromise of periapical bone, achievement of bone regeneration after the surgical procedure may be hampered. In such cases, the application of guided tissue regeneration principles, with adjunctive use of leukocyte platelet-rich fibrin to fill the bone defect as a bone substitute and as a membrane to cover the site, provides a cost-effective solution with the benefits of accelerated physiological healing and reduced post-surgical pain and discomfort. This case report presents 2 cases of endodontic microsurgery of the upper lateral incisors with loss of buccal cortical plate, where platelet-rich fibrin was successfully applied.

Mechanical Properties Characteristics according to Heat Treatment Conditions of Medical Bone Plates by 3D Printing (3D프린팅 제조기반 골절합용 금속판의 열처리 조건에 따른 기계적 성능 특성)

  • Jung, Hyunwoo;Park, Sung Jun;Woo, Heon
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.116-123
    • /
    • 2022
  • This study analyzes the Mechanical properties of a medical bone plate by 3D printing. With the recent development of 3D printing technology, it is being applied in various fields. In particular, in the medical field, the use of 3D printing technology, which was limited to the existing orthosis and surgical simulation, has recently been used to replacement bones lost due to orthopedic implants using metal 3D printing. The field of application is increasing, such as replacement. However, due to the manufacturing characteristics of 3D printing, micro pores are generated inside the metal printing output, and it is necessary to reduce the pores and the loss of mechanical properties through post-processing such as heat treatment. Accordingly, the purpose of this study is to analyze the change in mechanical performance characteristics of medical metal plates manufactured by metal 3D printing under various conditions and to find efficient metal printing results. The specimen to be used in the experiment is a metal plate for trauma fixation applied to the human phalanx, and it was manufactured using the 'DMP Flex 100(3D Systems, USA), a metal 3D printer of DMLS (Direct Metal Laser Sintering) method. It was manufactured using the PBF(Powder Bed Fusion) method using Ti6Al4V ELI powder material.

Pattern of microimplant displacement during maxillary skeletal expander treatment: A cone-beam computed tomography study

  • Ney Paredes;Ausama Gargoum;Ramon Dominguez-Mompell;Ozge Colak;Joseph Bui;Tam Duong;Maya Giannetti;Fernanda Silva;Kendra Brooks;Won Moon
    • The korean journal of orthodontics
    • /
    • v.53 no.5
    • /
    • pp.289-297
    • /
    • 2023
  • Objective: To analyze the microimplant (MI) displacement pattern on treatment with a maxillary skeletal expander (MSE) using cone-beam computed tomography (CBCT). Methods: Thirty-nine participants (12 males and 27 females; mean age, 18.2 ± 4.2 years) were treated successfully with the MSE II appliance. Their pre- and post-expansion CBCT data were superimposed. The pre- and post-expansion anterior and posterior inter-MI angles, neck and apical inter-MI distance, plate angle, palatal bone thickness at the MI positions, and suture opening at the MI positions were measured and compared. Results: The jackscrew plate was slightly bent in both anterior and posterior areas. There was no significant difference in the extent of suture opening between the anterior and posterior MIs (P > 0.05). The posterior MI to hemiplate line was greater than that anteriorly (P < 0.05). The apical distance between the posterior MIs was greater than that anteriorly (P < 0.05). The palatal thickness at the anterior MIs was significantly greater than that posteriorly (P > 0.01). Conclusions: In the coronal plane, the angulation between the anterior MIs in relation to the jackscrew plate was greater than that between the posterior MIs owing to the differential palatal bone thickness.

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

REGIONAL THICKNESS OF PARIETAL BONE IN KOREAN ADULTS (한국인 성인에서 두정골의 부위별 두께에 대한 연구)

  • Cha, In-Ho;Kim, Hee-Jin;Jeong, Young-Soo;Yi, Choong-Kook;Chung, In-Hyuk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.3
    • /
    • pp.269-273
    • /
    • 1998
  • To clarify the clinical utility of the calvarial bone graft in the maxillofacial reconstruction, we performed on anatomical study by measuring the regional thickness of the parietal bone on 17 Korean adult dry skulls. Before the sectioning the calvarium, the anatomical landmarks were marked on each specimens. And then we measured the total thickness of the parietal bone, the thickness of the outer and inner cortical plates on various points in each sections of parietal bones using a digital caliper under the stereomicroscope. The total thickness of the parietal bone was ranged from 5.17mm to 7.50mm, and there were no statistical difference in the total thickness of the parietal bone on the same points bilaterally. But there was a tendency that the thickness of the parietal bone was thicker toward to the lambda point than the coronal suture area. At the other hand, the thickness of the outer and inner plate of the parietal bone was the thickest at the first point of the right aspect on the line 1, the first point of the left aspect on the line 5, respectively. In conclusion, this study showed that the donor site of the parietal bone for the maxillofacial reconstruction should be located at more posterior and medial area of the parietal bone than the prevalent known donor site.

  • PDF

QUANTITATIVE ANALYSIS OF THE ALVEOLAR BONE CHANGE BY THE DIGITAL SUBTRACTION RADIOGRAPHY (Digital subtraction radiography를 이용한 치조골 변화의 정략적 분석)

  • Ryue, Myung-Girl;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.67-75
    • /
    • 1995
  • The progress of periodontal disease and the wound healing process after treatment result in alveolar bone bone change. So, detection of it is very important in the diagnosis and the radiograph of periodontal disease. Various effects have been made to assess the subtle alveolar bone change and digital subtraction radiography (DSR) has been reported to be the best method in evaluating it qualitatively and quantitatively. The present study was performed to estimate the detectable alveolar bone change qualitatively with digital subtraction radiography. For the in vitro study, 10 intraoral standard radiographs were taken from porcine dry mandible which a rectangular cortical bone chip of 0.1mm to 1.0mm thickness with 0.1mm increment was attached on the buccal surface. The radiographs without and with bone plates were reviewed at the same time by 10 observers and requested to detect the presence of cortical bone plates. Digital Subtraction radiograph was reviewed subsequently by using the DSR system(digital converter-256 grey-levels,DT 2851,Data Translation Co., U.S.A;IBM 386 ; CCD camera, FOTOVIX, Tamrom Co., Japan). The detectable thickness of cortical bone plate was O.4mm on the intraoral radiograph and 0.2mm on the subtaction images. For the human study, radiographs were taken from patients by using intraoral film holding device and aluminum reference wedge before and 3 month after bone graft and 1 week after osteoplasty. The grey level change was estimated in the subtraction images and calculated to aluminum equivalent thickness. The grey level of the grafted site was higher that that of healthy controls. Average grey levels of change on healthy controls were O.48mm aluminum equivalent. However, the amount of changes in grafted sites were 1.87mm aluminum thickness equivalent and in the site of osteoplasty were -1.49mm aluminum thickness equivalent. In conclusion, digital subtraction radiography was more effective in detecting as subtle change of alveolar bone than intraoral standard radiography. With the aid of quantitative analysis of digital subtraction radiography, alveolar bone resorption of apposition can be estimated during diagnosis and treatment of periodontally diseased patients.

  • PDF

HORIZONTAL AUGMENTATION WITH AUTOGENOUS BLOCK BONE AND IMPLANT PLACEMENT (자가 블록골을 이용한 치조골수평증강술과 임프란트 식립)

  • Ahn, Ji-Yeon;Kim, Young-Kyun;Yun, Pil-Young;Hwang, Jung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.5
    • /
    • pp.444-450
    • /
    • 2007
  • In general, labiolingual or buccolingual widths of residual alveolar bone are insufficient in edentulous area, because of alveolar resorption. Horizontal augmentation is bone graft procedure with a view to reinforcing horizontally insufficient bone quantity for installation of implants. The standard method is taking appropriate amount of block bone from intraoral or extraoral autogenous bone, and solid fixation with screws or mini-plate on labial or buccal side of residual alveolar bone. The purpose of this study is to discuss clinical usefulness of horizontal augmentation with autogenous block bone by observation and analysis of course of 41 implants installed to 12 patients by horizontal augmentation in Seoul National University Bundang Hospital from July, 2002 to December, 2005. The mean age of patients is 52.7, from 19 to 70, and the number of men and women is each 2 and 10. Block bone was taken from symphysis, body, ramus of mandible or iliac bone. And 6 types of implants were installed simultaneously or not, the diameters of implants are from 3.3 to 5.5mm, the lengths are from 8 to 15mm. The operator added artificial bone grafting material and optionally covered with membrane. The mean periods of observation after operation and final prosthetics were 28.6 and 17.0 months. As a result, 40 among 41 implants survived, the survival rate was 97.6%. Average 0.9mm crestal resorption was observed at final point of time by periapical view of each patients. Major complication related to the procedure was numbness in 7 patients.

Diagnostic imaging of nasal malignant melanoma in a dog (개 비강에서 발생한 악성 흑색종의 영상 진단 증례)

  • Jung, Joohyun;Kwon, Jungkook;Chang, Jinhwa;Oh, Sunkyoung;You, Mi-Hyeon;Kim, Dae-Yong;Yoon, Junghee;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.3
    • /
    • pp.369-374
    • /
    • 2008
  • A neutered male, 8-year-old, Pekingese, weighing 4.3 kg with a history of anorexia, sneezing, nasal discharge, and epistaxis for one month was referred. Soft tissue swelling around the nasal bone and small defects of the hard palate with a tiny round dark red mass were found on physical examination. The laboratory tests represented mild leukocytosis. On skull radiographs, soft tissue swelling and osteolytic change of the incisor bone, nasal bone, and maxilla were found. On computed tomography scan images, there was soft tissue attenuating opacity with calcified spots in the bilateral nasal cavities and frontal sinuses. Loss of nasal turbinate pattern and nasal septum was found. And destruction of the insicor bone, nasal bone, maxilla, hard palate, perpendicular palatine bone, and cribriform plate were identified. Nasal malignant melanoma was confirmed by nasal biopsy.

Modified Anterior Craniofacial Osteotomy Using Partial Nasal Bone Division and Reconstruction in Frontoethmoidal Sinus Meningioma

  • Park, Eon Ju;Kim, Hong Il;Park, Jin Hyung;Yi, Hyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.117-121
    • /
    • 2017
  • Typical transcranial approaches are insufficient for adequate visualization and resection of skull base tumors. Different approaches with multiple modifications have been attempted. Here, we describe a new approach for a lesion that is central and hard to treat by conventional craniotomy and successful reconstruction with calvarial bone graft and titanium mesh plate. A 69-year-old female patient presented with recurrent meningioma. The tumor had invaded the frontal lobe, right supraorbital rim, and ethmoidal bone. We performed a modified anterior craniofacial approach that fully exposed the tumor and invaded bone. In consideration of the patient's age and cosmetic result, the tumor and invaded bone was resected and the defect area was reconstructed with titanium mesh and calvarial bone graft. At 6 months postoperative the patient had no complications and was satisfied with the esthetic result. We report this case to demonstrate the successful approach and reconstruction using this technique.