• 제목/요약/키워드: Bone Characteristics

Search Result 949, Processing Time 0.029 seconds

Angiogenesis in newly regenerated bone by secretomes of human mesenchymal stem cells

  • Katagiri, Wataru;Kawai, Takamasa;Osugi, Masashi;Sugimura-Wakayama, Yukiko;Sakaguchi, Kohei;Kojima, Taku;Kobayashi, Tadaharu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.8.1-8.8
    • /
    • 2017
  • Background: For an effective bone graft for reconstruction of the maxillofacial region, an adequate vascular network will be required to supply blood, osteoprogenitor cells, and growth factors. We previously reported that the secretomes of bone marrow-derived mesenchymal stem cells (MSC-CM) contain numerous growth factors such as insulin-like growth factor (IGF)-1, transforming growth factor $(TGF)-{\beta}1$, and vascular endothelial growth factor (VEGF), which can affect the cellular characteristics and behavior of regenerating bone cells. We hypothesized that angiogenesis is an important step for bone regeneration, and VEGF is one of the crucial factors in MSC-CM that would enhance its osteogenic potential. In the present study, we focused on VEGF in MSC-CM and evaluated the angiogenic and osteogenic potentials of MSC-CM for bone regeneration. Methods: Cytokines in MSC-CM were measured by enzyme-linked immunosorbent assay (ELISA). Human umbilical vein endothelial cells (HUVECs) were cultured with MSC-CM or MSC-CM with anti-VEGF antibody (MSC-CM + anti-VEGF) for neutralization, and tube formation was evaluated. For the evaluation of bone and blood vessel formation with micro-computed tomography (micro-CT) and for the histological and immunohistochemical analyses, a rat calvarial bone defect model was used. Results: The concentrations of IGF-1, VEGF, and $TGF-{\beta}1$ in MSC-CM were $1515.6{\pm}211.8pg/mL$, $465.8{\pm}108.8pg/mL$, and $339.8{\pm}14.4pg/mL$, respectively. Tube formation of HUVECs, bone formation, and blood vessel formation were increased in the MSC-CM group but decreased in the MSC-CM + anti-VEGF group. Histological findings suggested that new bone formation in the entire defect was observed in the MSC-CM group although it was decreased in the MSC-CM + anti-VEGF group. Immunohistochemistry indicated that angiogenesis and migration of endogenous stem cells were much more abundant in the MSC-CM group than in the MSC-CM + anti-VEGF group. Conclusions: VEGF is considered a crucial factor in MSC-CM, and MSC-CM is proposed to be an adequate therapeutic agent for bone regeneration with angiogenesis.

The Effects of the Thera Band Exercise Program on Bone Mineral Density and Health Promotion Behaviors in Elderly Women (세라밴드 운동 프로그램이 여성노인의 골밀도와 건강증진행위에 미치는 효과)

  • Kim, Joo Hyun;Hyun, Hye Jin;Ahn, Mi Hyang;Choi, Eun Young;Ko, Ga Yeon;Park, Bock Soon
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.3
    • /
    • pp.147-153
    • /
    • 2013
  • Purpose: This study was conducted in order to closely examine the effects on bone mineral density and health promotion behaviors following the intervention of a 20-week Thera band exercise program targeting elderly women. Methods: This study is a pseudo-experimental research with a pre-and-post design in a single group that examined the effects after the intervention of Thera Band Exercise for 20 weeks targeting 31 elderly women over 60 years of age who visit a Senior Welfare Center located in K city. It analyzed subjects' general characteristics using error and percentage, health promotion behavior, and a bone density aspect using the mean and standard deviation, as well as a change in the health promotion behavior and bone density, before and after exercise with Paired t-test by using the SPSS 18.0 program. Results: The effect of the Thera band exercise program on bone mineral density was reduced (t=8.140, p<.001) gradually after 20 weeks of exercise compared to the pre-exercise period. The health promotion behavior before and after exercise showed the significantly increasing outcomes (t=3.26, p=.003). Conclusion: There is a limitation to a direct rise in bone mineral density with the use of Thera band exercise intervention in the elderly. A change in health promotion behavior before and after exercise increased significantly. Thus, it was confirmed that taking exercise leads to a gradual rise in health promotion behavior. Hence, it understood that continuous exercise is useful and brings about a positive change in promoting health maintenance in elderly women.

Geometric and mechanical properties evaluation of scaffolds for bone tissue applications designing by a reaction-diffusion models and manufactured with a material jetting system

  • Velasco, Marco A.;Lancheros, Yadira;Garzon-Alvarado, Diego A.
    • Journal of Computational Design and Engineering
    • /
    • v.3 no.4
    • /
    • pp.385-397
    • /
    • 2016
  • Scaffolds are essential in bone tissue engineering, as they provide support to cells and growth factors necessary to regenerate tissue. In addition, they meet the mechanical function of the bone while it regenerates. Currently, the multiple methods for designing and manufacturing scaffolds are based on regular structures from a unit cell that repeats in a given domain. However, these methods do not resemble the actual structure of the trabecular bone which may work against osseous tissue regeneration. To explore the design of porous structures with similar mechanical properties to native bone, a geometric generation scheme from a reaction-diffusion model and its manufacturing via a material jetting system is proposed. This article presents the methodology used, the geometric characteristics and the modulus of elasticity of the scaffolds designed and manufactured. The method proposed shows its potential to generate structures that allow to control the basic scaffold properties for bone tissue engineering such as the width of the channels and porosity. The mechanical properties of our scaffolds are similar to trabecular tissue present in vertebrae and tibia bones. Tests on the manufactured scaffolds show that it is necessary to consider the orientation of the object relative to the printing system because the channel geometry, mechanical properties and roughness are heavily influenced by the position of the surface analyzed with respect to the printing axis. A possible line for future work may be the establishment of a set of guidelines to consider the effects of manufacturing processes in designing stages.

Characteristics and response of mouse bone marrow derived novel low adherent mesenchymal stem cells acquired by quantification of extracellular matrix

  • Zheng, Ri-Cheng;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.351-360
    • /
    • 2014
  • PURPOSE. The aim of present study was to identify characteristic and response of mouse bone marrow (BM) derived low-adherent bone marrow mesenchymal stem cells (BMMSCs) obtained by quantification of extracellular matrix (ECM). MATERIALS AND METHODS. Non-adherent cells acquired by ECM coated dishes were termed low-adherent BMMSCs and these cells were analyzed by in vitro and in vivo methods, including colony forming unit fibroblast (CFU-f), bromodeoxyuridine (BrdU), multi-potential differentiation, flow cytometry and transplantation into nude mouse to measure the bone formation ability of these low-adherent BMMSCs. Titanium (Ti) discs with machined and anodized surfaces were prepared. Adherent and low-adherent BMMSCs were cultured on the Ti discs for testing their proliferation. RESULTS. The amount of CFU-f cells was significantly higher when non-adherent cells were cultured on ECM coated dishes, which was made by 7 days culturing of adherent BMMSCs. Low-adherent BMMSCs had proliferation and differentiation potential as adherent BMMSCs in vitro. The mean amount bone formation of adherent and low-adherent BMMSCs was also investigated in vivo. There was higher cell proliferation appearance in adherent and low-adherent BMMSCs seeded on anodized Ti discs than machined Ti discs by time. CONCLUSION. Low-adherent BMMSCs acquired by ECM from non-adherent cell populations maintained potential characteristic similar to those of the adherent BMMSCs and therefore could be used effectively as adherent BMMSCs in clinic.

A HISTOLOGIC COMPARATIVE STUDY OF LOADED AND UNLOADED TITANIUM IMPLANTS (LOADED IMPLANT와 UNLOADED IMPLANT의 조직학적 비교 연구)

  • Kim, Yung-Soo;Ko, Jea-Seung;Hwang, Sung-Myung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.1-16
    • /
    • 1991
  • In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants were inserted. Some implants were functionally loaded through fixed detachable prosthesis and some are isolated and unloaded. The dog was sacrificed four months later and bone sections with implants were processed for histologic evaluation and the results were as follows ; (1) The bone to implant interface after four months of load bearing presented no mobility and no marginal bone loss radiographically and histologically. (2) The interface zone between compact bone and implant revealed a direct bone to implant contact and in some areas marrow tissue contacts were examined at the light microscopic level. (3) At the ultrastructural level the interface of surrounding compact bone matrix and implant, three types of superficial layers were found ; one with moderate electron dense amorphous granular substance layer, other with high electron dense fine granular substance layer, and another type of amorphous granular substance covered with high electron dense line of minute granules. (4) The osteoblasts in the marrow tissue neighboring implants and osteocytes in compact bone showed typical normal characteristics and in the marrow tissues some of lymphocytes and mast cells were observed. (5) The abscence of abnormal tissue reactions at a cellular level indicates a high degree of biocompatibility for the experimental titanium implant and basically no difference was found between functionally loaded and unloaded implants.

  • PDF

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

Study of bony trabecular characteristics using bone morphometry and micro-CT (골형태분석법과 micro-CT를 이용한 골소주 특성에 대한 연구)

  • Song, Young-Han;Lee, Wan;Lee, Chang-Jin;Ji, Jung-Hyun;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose : The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Materials and Methods : Twenty-one female (Newzealand, about 16 weeks old, 2.9-3.4kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Baseline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1, 2, 3, 5, 6 months respectively, BMD tests were performed on the proximal femur by using PIXlmus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custome computer program and 2D/3D bone structure analysis by micro-CT (Skyscan 1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD Result : BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp, Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Conclusion : Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change.

  • PDF

In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing

  • Lee, Hyo-Jung;Yang, Il-Hyung;Kim, Seong-Kyun;Yeo, In-Sung;Kwon, Taek-Ka
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.94-100
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the combined effects of physical and chemical surface factors on in vivo bone responses by comparing chemically modified hydrophilic sandblasted, large-grit, acid-etched (modSLA) and anodically oxidized hydrophobic implant surfaces. Methods: Five modSLA implants and five anodized implants were inserted into the tibiae of five New Zealand white rabbits (one implant for each tibia). The characteristics of each surface were determined using field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy before the installation. The experimental animals were sacrificed after 1 week of healing and histologic slides were prepared from the implant-tibial bone blocks removed from the animals. Histomorphometric analyses were performed on the light microscopic images, and bone-to-implant contact (BIC) and bone area (BA) ratios were measured. Nonparametric comparison tests were applied to find any significant differences (P<0.05) between the modSLA and anodized surfaces. Results: The roughness of the anodized surface was $1.22{\pm}0.17{\mu}m$ in Sa, which was within the optimal range of $1.0-2.0{\mu}m$ for a bone response. The modSLA surface was significantly rougher at $2.53{\pm}0.07{\mu}m$ in Sa. However, the modSLA implant had significantly higher BIC than the anodized implant (P=0.02). Furthermore, BA ratios did not significantly differ between the two implants, although the anodized implant had a higher mean value of BA (P>0.05). Conclusions: Within the limitations of this study, the hydrophilicity of the modSLA surface may have a stronger effect on in vivo bone healing than optimal surface roughness and surface chemistry of the anodized surface.

The Study of Relation among Serum Leptin, Lipids, Bone Metabolism Marker and Nutrient Intakes of Middle-school Girls (일부 사춘기 여중생의 혈청 렙틴, 지질, 골대사 지표 및 영양 섭취 상태와의 관계)

  • Lee, Da-Hong;Bae, Yun-Jung;Sung, Chung-Ja
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.17 no.2
    • /
    • pp.183-191
    • /
    • 2007
  • The purpose of this study was to investigate the relationship between serum leptin, lipids, bone metabolism markers and nutrient intakes of obese middle-school girls compared to those of normal subjects. Each subject was assigned to either the normal(n=22) or obese groups(n=25) according to their BMI. The subjects were asked for their general characteristics and nutrient intakes using a questionnaire and 24-hr recall method. The serum leptin, lipids and osteocalcin(bone metabolism marker) were measured using blood analyses. The average ages of the subjects in the normal and obese groups were 13.9 and 14.0 years, respectively. The average weight(p<0.001) and BMI(p<0.001) of normal group were significantly lower than those of the obese group. The plant protein intake of the girls in the obese group was lower than that of the normal group(p<0.01). The levels of serum leptin in the obese and normal groups were 18.0 and 10.0 ng/mL, respectively(p<0.001). The serum LDL-cholesterol(p<0.01) and triacylgeride(p<0.05) of the obese girls were higher than those in the normal group. Also, the serum osteocalcin(bone formation marker) in the obese group was lower than that in the normal group(p<0.001). The BMI was negatively correlated to osteocalcin(p<0.001), but positively correlated to the serum leptin(p<0.001). The serum osteocalcin was also positively correlated to the plant protein intake(p<0.05). In conclusion, the excessive increase in weight and % body fat in middle-school students appeared to have a negative impact on bone health. Based on these results, further studies will be needed on the effects of bone metabolism markers, obesity and nutrient intakes for proper bone health.

  • PDF

Detection of bone marrow involvement with FDG PET/CT in patients with newly diagnosed lymphoma

  • Ozpolat, H. Tahsin;Yilmaz, Ebru;Goksoy, Hasan Sami;Ozpolat, Sahre;Dogan, Oner;Unal, Seher Nilgun;Nalcaci, Meliha
    • BLOOD RESEARCH
    • /
    • v.53 no.4
    • /
    • pp.281-287
    • /
    • 2018
  • Background Bone marrow involvement (BMI) affects the lymphoma stage, survival, and treatment. Bone marrow biopsy (BMB) and fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET/CT) are useful techniques to detect BMI. Both have advantages and disadvantages. We aimed to identify factors that could be used to predict BMI with positive and negative results on PET/CT compare them with BMB in newly diagnosed patients with lymphoma. Methods We included 22 non-Hodgkin and 16 Hodgkin lymphoma patients in this single center study. All patients had PET/CT examination and BMB before treatment. BMI in BMB was reported as negative or positive. Bone marrow was classified into 3 types by FDG uptake on PT/CT; diffuse involvement, focal involvement, and normal bone marrow. Results PET/CT and BMB results were concordant (7 positive, 15 negative) in 22 patients (57%). We evaluated concordant and discordant patient characteristics and risk-stratified patients for BMI. Our findings suggest that patients with diffuse FDG uptake on PET/CT, especially patients with advanced age and low platelet and white blood cell counts, are likely to have BMI and could potentially forego BMB. Patients with negative PET/CT findings and no significant laboratory abnormalities are very unlikely to have BMI. Conclusion Our results suggest that BMI should not be decided solely based PET/CT or BMB findings. It is reasonable to use both diagnostic assays along with clinical and laboratory findings. PET/CT result, clinical and laboratory findings could be useful for predicting BMI in patient for whom BMB is contraindicated.