• 제목/요약/키워드: Bond test

검색결과 1,567건 처리시간 0.025초

Efficient Pre-Bond Testing of TSV Defects Based on IEEE std. 1500 Wrapper Cells

  • Jung, Jihun;Ansari, Muhammad Adil;Kim, Dooyoung;Park, Sungju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권2호
    • /
    • pp.226-235
    • /
    • 2016
  • The yield of 3D stacked IC manufacturing improves with the pre-bond integrity testing of through silicon vias (TSVs). In this paper, an efficient pre-bond test method is presented based on IEEE std. 1500, which can precisely diagnose any happening of TSV defects. The IEEE std. 1500 wrapper cells are augmented for the proposed method. The pre-bond TSV test can be performed by adjusting the driving strength of TSV drivers and the test clock frequency. The experimental results show the advantages of the proposed approach.

GFRP Rebar의 부착성능에 관한 실험적 연구 (An Experimental Study on the Bond Characteristics of Glass Fiber Reinforced Polymer Rebar)

  • 박지선;유영찬;박영환;최기선;김형열;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.124-127
    • /
    • 2004
  • This study is to investigate the bond characteristics of glass fiber reinforced polymer(GFRP) reinforcing bars in concrete by pullout test experimentally. Three different types of GFRP bars with different surface deformations were considered in this study. Also, standard deformed steel reinforcing bar with or without epoxy-coating were included for the comparisons of bond strength. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendation of CSA(Canadian Standards Association) Standard S806-02. From the test results, it was found that small surface indentations contributed to increase the bond strength of GFRP bar significantly. Based on the limited test results till now, the bond strength of GFRP bar with sand-coated deformation commercially available in foreign market is around $80\%$ of that of steel deformed bars.

  • PDF

FRP or steel plate-to-concrete bonded joints: Effect of test methods on experimental bond strength

  • Chen, J.F.;Yang, Z.J.;Holt, G.D.
    • Steel and Composite Structures
    • /
    • 제1권2호
    • /
    • pp.231-244
    • /
    • 2001
  • The strengthening of reinforced concrete structures using externally bonded steel or advanced fibre reinforced plastic (FRP) composites is becoming increasingly common. A key factor affecting the behaviour and reliability of such strengthened structures is the bond strength between the steel or FRP plate and the concrete substrate. Several different experimental set-ups have previously been used to determine bond strength. This paper presents a careful finite element analysis of the stress distributions in these test set-ups. Results show that stress distributions can be significantly different for different set-ups, for similar materials and geometry.

직접인장 및 간접인장 실험방법에 따른 접착식 콘크리트 덧씌우기의 부착강도 비교 고찰 (Comparative Study on the Bond Strength between Direct Tensile Test and Indirect Tensile Test for Bonded Concrete Overlay)

  • 김영규;이승우
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.1153-1163
    • /
    • 2013
  • 접착식 콘크리트 덧씌우기는 기존 콘크리트 포장과의 재료물성이 유사하여 적절한 유지보수 공법으로 제시되고 있으며, 덧씌우기층과 기존 포장층이 완전부착을 통한 일체화 거동을 하여 우수한 구조적 성능을 확보할 수 있다. 따라서 접착식 콘크리트 덧씌우기의 장기 공용성을 위하여 적절한 부착강도 기준을 확보하는 것이 매우 중요하다. 본 연구에서는 다양한 부착 특성이 부착강도에 미치는 영향을 고찰하고자 하였으며, 덧씌우기 재료, 기존 포장의 압축강도 및 휨강도 변화, 기존 포장의 열화상태 등 다양한 부착조건에 대한 직접인장 및 간접인장 실험을 실시하여 도출되는 부착강도를 비교 분석하고자 하였다. 연구 결과, 직접인장실험에 의한 부착강도가 간접인장실험에 의한 부착강도보다 상대적으로 높게 분포하는 경향을 나타내고 있으나, 결정계수 0.75 및 P-value 0.002의 높은 부착강도 상관관계를 확보하였다. 이를 통하여 접착식 콘크리트 덧씌우기의 실제 현장 거동을 모사할 수 있는 반복하중에 의한 부착 피로 특성 분석 시 직접인장 및 간접인장 실험의 상관관계를 활용할 수 있을 것으로 판단된다.

라텍스 개질 콘크리트의 부착강도 특성 (Bond Strength Properties of Latex Modified Concrete)

  • 윤경구;이주형;최상릉;김기헌
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.507-515
    • /
    • 2001
  • 신.구 콘크리트 부착계면의 부착강도는 신 콘크리트에 라텍스를 이용하여 개선할 수 있다. 그러나, 현재까지 신.구 콘크리트 사이의 부착강도를 측정하기 위해 표준으로 채택되어진 실험은 아직 없다. 일축인장시험에서, 신.구 콘크리트 계면의 부착강도는 시험체의 파단 시 인장에 의해 실제적으로 구해진다. 본 연구에서 새로이 제시한 직접인장 부착강도 실험으로 라텍스 개질 콘크리트의 부착특성을 평가하고자 하였다. 새로이 제시되는 직접인발 부착강도 실험을 위하여 현장과 같은 조건의 슬래브를 제작하여 pull-out 실험을 실시하였으며, 기존의 시편을 이용한 직접인장 실험 시편을 제작하여 본 연구에서 사용하였다. 실험결과는 다음과 같다: 라텍스 혼입율 증가에 따라 부착강도는 증가하는 것으로 나타났다. 이를 통해 라텍스에 의한 부착력증진을 확인할 수 있었다. 또한, 기존 콘크리트의 표면처리에 따른 라텍스 개질 콘크리트의 부착특성을 평가한 결과, 표면처리에 따라 라텍스 개질 콘크리트의 부착강도가 개선되는 것으로 나타났다. 기존 콘크리트의 표면함수상태에 따른 라텍스 개질 콘크리트의 부착특성을 평가하기 위해서 다양한 표면함수상태에서 부착강도를 평가한 결과, 표면건조포화상태가 가장 이상적인 조건임을 알 수 있었다.

철근 콘크리트 부재의 부착거동에 관한 실험적 연구 (An Experimental Investigation on the Bond Characteristics of Reinforced Concrete Structure)

  • 오병환;이성로;방기성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.122-127
    • /
    • 1990
  • The transfer of forces across the interface by bond between concrete and steel is of fundamental importance to many aspects of reinforced concrete behavior. Bond stress - slip relationships were studied using a symmetrical tension test specimen. This type of test is intented to simulate conditions in the tension zone of a concrete beam between primary cracks and below the neutral axis. These relationships between local bond stress and local slip are quite different at different locations along the bar. The present study allows more accurate analysis of reinforced concrete structures by employing more realistic bond stress-slip relations.

  • PDF

프리텐션공법의 프리스트레스트 콘크리트 부재의 정착길이 산정에 관한 실험 및 이론연구 (Derivation of Development Length in Pretensioned Prestressed Concrete Members)

  • 오병환;김의성;최영철
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.3-11
    • /
    • 2000
  • In pretensioned concrete structures, bond between prestressing steel and concrete is an essential component to ensure the integrity of a pretensioned member. The anchorage and development of the prestressing force depend exclusively on bond. The purpose of this study is to investigate the characteristics of bond and development length between pretensioned steel and concrete. To resolve the controversy over the adequacy of the current code provision on development length of prestressing strands, a comprehensive test program has been scheduled and twenty four rectangular prestressed concrete beams have been tested to determine development length. Major test variables include diameter of strands (12.7mm, 15.2mm) and concrete covers (3cm, 4cm, 5cm). The test results indicate that the development length based on the bond stress-slip relation. The proposed model can evaluate realistically the development length of pretensioned prestressed concrete members and can be the good basis for the future basis of code equations on development length of PSC members.

Residual bond behavior of high strength concrete-filled square steel tube after elevated temperatures

  • Chen, Zongping;Liu, Xiang;Zhou, Wenxiang
    • Steel and Composite Structures
    • /
    • 제27권4호
    • /
    • pp.509-523
    • /
    • 2018
  • This paper presents experimental results on the residual bond-slip behavior of high strength concrete-filled square steel tube (HSCFST) after elevated temperatures. Three parameters were considered in this test: (a) temperature (i.e., $20^{\circ}C$, $200^{\circ}C$, $400^{\circ}C$, $600^{\circ}C$, $800^{\circ}C$); (b) concrete strength (i.e., C60, C70, C80); (c) anchorage length (i.e., 250 mm, 400 mm). A total of 17 HSCFST specimens were designed for push-out test after elevated temperatures. The load-slip curves at the loading end and free end were obtained, in addition, the distribution of steel tube strain and the bond stress along the anchorage length were analyzed. Test results show that the shape of load-slip curves at loading ends and free ends are similar. With the temperature constantly increasing, the bond strength of HSCFST increases first and then decreases; furthermore, the bond strength of HSCFCT proportionally increases with the anchoring length growing. Additionally, the higher the temperature is, the smaller and lower the bond damage develops. The energy dissipation capacity enhances with the concrete strength rasing, while, decreases with the temperature growing. What is more, the strain and stress of steel tubes are exponentially distributed, and decrease from the free end to loading end. According to experimental findings, constitutive formula of the bond slip of HSCFST experienced elevated temperatures is proposed, which fills well with test data.

Bond Analysis of Ribbed Reinforcing Bars

  • Park, Oan-Chul
    • KCI Concrete Journal
    • /
    • 제13권2호
    • /
    • pp.19-25
    • /
    • 2001
  • A simple expression to predict bond strength of reinforcing bars with rib deformation to the surrounding is derived for the case of splitting bond failure. Finite element analysis is used to model the confining behavior of concrete cover. The roles of the interfacial properties, specifically, the friction coefficient, cohesion, the relative rib area and the rib face angle are examined. Values of bond strength obtained using the analytical model are in good agreement with the bond test results from the previous studies. The analytical model provides insight into interfacial bond mechanisms and the effects of the key variables on the bond strength of deformed bars to concrete. Based on the comparison between the analytical results and the test results, the values of cohesion, coefficient of friction, and the effective rib face angle are proposed.

  • PDF

보 단부 부착시험체에 의한 높은마디 철근의 부착성능 (Evaluate Bond strength of high Relative Rib Area Bars Using Beam-end test specimens)

  • 서동민;양승열;홍기섭;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.112-115
    • /
    • 2004
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force has a limitation. Thus, the only variable is the bearing angle corresponding to the change of bond force. Higher rib height bars possessing higher shearing resistance can maintain higher bearing angle and higher splitting resistance when bars are highly confined, and consequently higher bond strength, than lower rib higher bars. In this study, from the evaluate bond strength of high Relative Rib Area Bars Using beam-end test specimens are compared with the current provisions for development of reinforcement, and the improved design method of bond strength is proposed.

  • PDF