• 제목/요약/키워드: Bond test

검색결과 1,567건 처리시간 0.03초

Ag-Ti계 합금을 사용한 SiC/SiC 및 SiC/연강 브레이징에 대한 연구 (A Study on SiC/SiC and SiC/Mild steel brazing by the Ag-Ti based alloys)

  • 이형근;이재영
    • Journal of Welding and Joining
    • /
    • 제14권4호
    • /
    • pp.99-108
    • /
    • 1996
  • The microstructure and bond strength are examined on the SiC/SiC and SiC/mild steel joints brazed by the Ag-Ti based alloys with different Ti contents. In the SiC/SiC brazed joints, the thickness of the reaction layers at the bond interface and the Ti particles in the brazing alloy matrices increase with Ti contents. When Ti is added up to 9 at% in the brazing alloy. $Ti_3SiC_2$ phase in addition to TiC and $Ti_5Si_3$ phase is newly created at the bond interface and TiAg phase is produced from peritectic reaction in the brazing alloy matrix. In the SiC/mild steel joints brazed with different Ti contents, the microstructure at the bond interface and in the brazing alloy matrix near SiC varies similarly to the case of SiC/SiC brazed joints. But, in the brazing alloy matrix near the mild steel, Fe-Ti intermetallic compounds are produced and increased with Ti contents. The bond strengths of the SiC/SiC and SiC/mild steel brazed joints are independent on Ti contents in the brazing alloy. There are no large differences of the bond strength between SiC/SiC and SiC/mild steel brazed joints. In the SiC/mild steel brazed joints, Fe dissolved from the mild steel does not affect on the bond strength of the joints. Thermal contraction of the mild steel has nearly no effects on the bond strength due to the wide brazing gap of specimens used in the four-point bend test. The brazed joints has the average bond strength of about 200 MPa independently on Ti contents, Fe dissolution and joint type. Fracture in four-point bend test initiates at the interface between SiC and TiC reaction layer and propagates through SiC bulk. The adhesive strength between SiC and TiC reaction layer seems to mainly control the bond strength of the brazed joints.

  • PDF

고강도 횡보강근을 사용한 철근콘크리트 보의 부착 거동 평가 (Evaluation of Bond Behavior of Reinforced Concrete Beams with High-Strength Transverse Reinforcement)

  • 김상우;김영식;백승철;김길희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권5호
    • /
    • pp.102-109
    • /
    • 2010
  • 이 논문에서는 고강도 횡보강근을 가진 철근콘크리트 보의 부착 거동을 연구하였다. 제안된 비폐쇄형 U자 보강근의 부착 성능을 평가하기 위하여 총 4개의 철근콘크리트 보를 실험하였다. 제안된 비폐쇄형 U자 보강근은 쉽게 설치할 수 있는 구조를 가졌을 뿐만 아니라 부착 균열을 억제함으로써 철근콘크리트 보의 부착 성능을 증가시킬 수 있다. 이 연구에서는 실험체의 부착 응력과 미끄러짐을 구하기 위하여 Ichinose가 제안한 실험방법을 따랐다. 주요 실험변수는 횡보강근의 항복강도와 보강근비 및 구속의 형태로 하였다. 실험결과, 제안된 비폐쇄형 U자 보강근은 고강도 횡보강근을 사용한 철근콘크리트 보의 부착 성능을 효과적으로 향상시켰음을 확인할 수 있었다.

배합 및 접합면 처리에 따른 신·구 콘크리트의 부착특성 평가 (Assessment of Bond Characteristics between New and Old Concrete in Various Mixtures and Joint Conditions)

  • 조병두;김상현;전세진
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.507-515
    • /
    • 2014
  • 콘크리트 구조물의 시공이음부는 적절한 처리에도 불구하고 누수되는 사례가 빈번히 발생되고 있다. 이 연구에서는 이러한 누수 현상이 신 구 콘크리트 간의 부착특성과도 관련이 있을 것으로 보고 이에 대한 실험을 실시하였다. 여러가지 조건하에서 부착특성을 평가하기 위해 신 구 콘크리트의 접합부를 모사하는 시편들을 제작하여 접합부의 접착강도, 휨강도 및 쪼갬인장강도를 측정하였다. 주요 실험 변수는 혼화재의 종류 및 혼입률, 접합면의 처리 방법, 지수판의 종류였다. 그 외 신 구 콘크리트 타설 간격의 영향, 강도시험 재령에 따른 영향도 고찰하였다. 실험 결과 혼화재 사용에 따라 부착강도가 어느정도 증가하는 것으로 나타났는데, 이는 포졸란 반응에 의해 생성되는 칼슘실리케이트 수화물이 접합부의 공극을 메우기 때문으로 생각된다. 한편, 접합면이 거칠고 건조할수록 부착성능이 향상되었으며, 지수판의 표면 거칠기는 지수판의 부착성능에 영향을 미치는 것으로 나타났다. 또한 시험 방법에 따른 부착강도의 차이가 발생하므로 이를 고려한 평가가 요망된다.

Effect of Titanium Surface Treatments Bond Strength and Cytotoxicity in Titanium-Porcelain System

  • 정인성
    • 대한의생명과학회지
    • /
    • 제14권2호
    • /
    • pp.105-113
    • /
    • 2008
  • The objective of this study was to evaluate the influence of surface modifications on the bonding characteristics and cytotoxicity of specific titanium porcelain bonded to milling titanium and cast titanium. Milling titanium and cast titanium samples were divided into 8 test groups. These groups are as follow: i) sandblasted with particles of different size of $220{\mu}m\;and\;50{\mu}m$, ii) different sequences of sandblasting treatment and etching treatment, iii) etched with different etching solutions, and iv) preheated or not. The surface characteristics of specimens were characterized by the test of mean roughness of surface and SEM. The bond strength of titanium-ceramic systems was measured by using three-point bending test and SEM. The results show that the mean roughness of surface of sample sandblasted with $220{\mu}m$ aluminum oxide increased and bond strength were higher than sample sandblasted with $50{\mu}m$ aluminum oxide. The mean roughness of surface decreased, but the bond strength increased when the samples sandblasted with $220{\mu}m$ aluminum oxide were preheated. The sample sandblasted with $220{\mu}m$ aluminum oxide after oxidized with occupational corrosive agent I (50% NaOH, 10% $CuSO_4{\cdot}5H_2O$) and II (35% $HNO_3$, 5% HF) showed higher bond strength than sample oxidized with 30% $HNO_3$ after sandblasted with $220{\mu}m$ aluminum oxide. Group NaCuNF220SP (milling Ti: 35.3985 MPa, casting Ti: 37.2306 MPa) which was treated with occupational corrosive agent I (50% NaOH, 10% $CuSO_4{\cdot}5H_2O$) and II (35% $HNO_3$, 5% HF), followed by sandblasting with $220{\mu}m$ aluminum oxide and preheating at $750^{\circ}C$ for 1 hour showed the highest bond strength and significant differences (P<0.05). The method for modifying surface of titanium showed excellent stability of cells.

  • PDF

New emerging surface treatment of GFRP Hybrid bar for stronger durability of concrete structures

  • Park, Cheolwoo;Park, Younghwan;Kim, Seungwon;Ju, Minkwan
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.593-610
    • /
    • 2016
  • In this study, an innovative and smart glass fiber-reinforced polymer (GFRP) hybrid bar was developed for stronger durability of concrete structures. As comparing with the conventional GFRP bar, the smart GFRP Hybrid bar can promise to enhance the modulus of elasticity so that it makes the cracking reduced than the case when the conventional GFRP bar is used. Besides, the GFRP Hybrid bar can effectively resist the corrosion of conventional steel bar by the GFRP outer surface on the steel bar. In order to verify the bond performance of the GFRP hybrid bar for structural reinforcement, uniaxial pull-out test was conducted. The variables were the bar diameter and the number of strands and pitch of the fiber ribs. Tensile tests showed a excellent increase in the modulus of elasticity, 152.1 GPa, as compared to that of the pure GFRP bar (50 GPa). The stress-strain curve was bi-linear, so that the ductile performance could be obtained. For the bond test, the entire GFRP hybrid bar test specimens failed in concrete splitting due to higher shear strength resulting in concrete crushing as a function of bar deformation. Investigation revealed that an increase in the number of strands of fiber ribs enhanced the bond strength, and the pitch guaranteed the bond strength of 19.1 mm diameter hybrid bar with 15.9 mm diameter of core section of deformed steel the ACI 440 1R-15 equation is regarded as more suitable for predicting the bond strength of GFRP hybrid bars, whereas the CSA S806-12 prediction is considered too conservative and is largely influenced by the bar diameter. For further study, various geometrical and material properties such as concrete cover, cross-sectional ratio, and surface treatment should be considered.

지압각 감소이론을 이용한 높은마디면적 철근의 부착강도 해석 (Bond Strength Analysis of High Relative Rib Area Bars Using Decreasing Bearing Angle Theory)

  • 양승열;서동민;박영수;홍건호;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.185-188
    • /
    • 2005
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond strength of ribbed reinforcing bars tends to split concrete cover, by wedging action, or shear the concrete in front of the ribs. In this study, using a reducing bearing angle theory, bond strengths of beam end specimen are predicted. Values of bond strength obtained using the analytical model are in good agreement with the bond test results. The analytical model provides insight into bond mechanism and the effects of bearing angle on the bond strength of deformed bars to concrete.

  • PDF

수중 불분리성 콘크리트의 부착 강도 특성에 관한 연구 (Bond Strength Properties of Antiwashout Underwater Concrete)

  • 김명식;김기동;윤재범
    • 콘크리트학회논문집
    • /
    • 제12권1호
    • /
    • pp.89-99
    • /
    • 2000
  • The objective of this study is to investigate the bond strength properties of antiwashout underwater concrete. The arrangement of bars (vertical bar, horizontal upper bar, horizontal lower bar), condition of casting and curing (fresh water, sea water), type of fine aggregate (river sand, blended sand(river sand : sea sand = 1:1), and proportioning strength of concrete (210, 240, 270, 300, 330kgf/$\textrm{cm}^2$)are chosen as the experimental parameters. The test results(ultimate bond stress) are compared with bond and development provisions of the ACI Building Code(ACI 318-89) and proposed equations from previous research(which was proposed by Orangun et. al). The experimental results show that ultimate bond stress of antiwashout underwater concrete which arranged bar on the horizontal lower, used the blend sand, and was cast and cured in the fresh water are higher that other conditions. The ultimate bond stress were increased in proportion to {{{{( SQRT {fcu }) }}3 2. From this study, rational analytic formula for the ultimate bond stress are to be from compressive strength of concrete.

Experimental investigation on steel-concrete bond in lightweight and normal weight concrete

  • Chen, How-Ji;Huang, Chung-Ho;Kao, Zhang-Yu
    • Structural Engineering and Mechanics
    • /
    • 제17권2호
    • /
    • pp.141-152
    • /
    • 2004
  • The bonding behaviors of Lightweight Aggregate Concrete (LWAC) and normal weight concrete were investigated experimentally. Pull-out tests were carried out to measure the bond strengths of three groups of specimens with compressive strength levels of 60, 40, and 20 MPa, respectively. Test results showed that the difference in the bond failure pattern between LWAC and normal weight concrete was significant as the concrete compressive strength became lower than 40 MPa. The corresponding bond strengths of LWAC were lower than that for normal weight concrete. As the compressive strength of concrete became relatively high (> 40 MPa), a bond failure pattern in normal weight concrete occurred that was similar to that in LWAC. The bond strength of LWAC is higher than that for normal weight concrete because it possesses higher mortar strength. Stirrup use leads to an increase of approximately 20% in nominal bond strength for both types of concrete at any strength level.

실리카퓸 및 메타카올린 치환률에 따른 고강도 콘크리트와 탄소섬유보강 폴리머 보강근의 부착거동 (Bond Behavior of Carbon Fiber Polymer Reinforced Polymer Rebar in High Strength Concrete with Replacement Ratio of Silica Fume and Metakaolin)

  • 박찬기;원종필;김종옥
    • 한국농공학회논문집
    • /
    • 제50권5호
    • /
    • pp.51-60
    • /
    • 2008
  • This study is to relate the bond characteristics of CFRP rebar in high strength concrete incorporated with silica fume(SF) and metakaolin(MK). An direct bond test were performed to evaluate the effect of SF and MK on bond properties of high-strength concrete and CFRP rebar. The high strength concrete mix included four SF and MK mixes with 0%, 5%, 10% and 15%. Results of bond performance experiment in relation to pullout vs slip behavior of FRP rebar and high strength showed better performance of SF than MK. Also, the results showed the improved bond strength as replacement ratio of SF and MK increased. The relative bond strength in which $1.3{\sim}3.2$ of estimated values were obtained.

지각과민억제제 적용이 수종 접착제의 미세인장결합강도에 미치는 영향 (EFFECT OF A DESENSITIZER ON MICROTENSILE BOND STRENGTH OF DIFFERENT ADHESIVES)

  • 황성연;이경하;유미경;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.378-384
    • /
    • 2003
  • This study evaluated the influence of a desensitizer(MS coat) on microtensile bond strength of different adhesives:a three-step adhesive(All-Bond 2), a two-step adhesive(Single Bond), a one-step adhesive(One-up Bond F). Non-caries extracted human molars were used. Dentin surface was obtained by horizontal section on mid-portion of crown using a water-cooled low speed diamond saw. Teeth were randomly divided into 6 group. AMO(MS coat + All Bond), SMO(MS coat + Single Bond)- and OMO(MS coat + One-up Bond F)-dentin surface were treated with 17% EDTA before bonded adhesive. AMX-, SMX- and OMX-dentin surface were bonded with All-Bond 2, Single Bond and One-up Bond F, respectively. with no previous treatment with MS coat and 17% EDTA. About 1cm high resin composite($Z-250^{TM}$) were incrementally build-up on the treated surface. The specimens for the microtensile test were serially sectioned perpendicular to the adhesive layer to obtain $0.7{\times}0.7mm$ sticks. 30 sticks were prepared from each group. After that. tensile bond strength for each stick was measured with Microtensile Tester at a 1mm/min crosshead speed. Fractured dentin surfaces were observed under the SEM. The results were statistically analysed by using a One-way ANOVA and Tukey's test(p<0.05). Value in MPa were: $AMO-44.35{\pm}13.21;{\;}SMO-39.35{\pm}13.32;{\;}OMO-31.07{\pm}10.25;{\;}AMX-49.22{\pm}16.38;{\;}SMX-56.02{\pm}13.35;{\;}OMX-72.93{\pm}16.19$. Application of MS coat reduced microtensile bond strengths of both Single Bond and One-up Bond F, whereas microtensile bond strengths of All-Bond 2 were not affected significantly.