• Title/Summary/Keyword: Boiler room

Search Result 38, Processing Time 0.023 seconds

Simulation of the hot water ONDOL heating system by response factor method (應答係數法에 의한 溫水 溫室 暖房 시스템의 Simulation)

  • 조상준;민만기;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.409-424
    • /
    • 1987
  • Simulation on the hot water ONDOL heating system was made in order to investigate the variation of room temperature and specific fuel consumption of boiler. Heat balance equation was derived by response factors and solved implicitly. Variation of room temperature and specific fuel consumption of boiler were calculated with respect to the thickness of room floor, the absorptivity of wall for solar radiation, on-off temperature range of boiler and air exchange. The results show that specific fuel consumption of boiler is independent of the thickness of room floor and decreases with increasing the absorptivity of wall and on-off temperature range of boiler. However, it increases with increasing the air exchange. They also show that, when the absorptivity and on-off temperature range of boiler are increased, the amplitudes of room temperature variation increase.

A Study on the Thermal Pump of the Hot Water Boiler (온수 보일러용 열구동 펌프에 관한 연구)

  • Yeom, Han-Gil;Kim, Uk-Joong;Kim, Chang-Ju
    • 연구논문집
    • /
    • s.30
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

A Study on the mitigation method of explosion and fire accidents in the Boiler room (보일러실 화재.폭발사고 경감방안에 관한 연구)

  • Son, Eun-Soo;Baek, Myoung-Gi;Song, Jae-Su;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.405-409
    • /
    • 2007
  • This paper focused on the way of prevention of disaster in the accident of explosion when the fire broke out in the boiler room where installed the basement of the building, and showed the effective ways for sustaining people and property safely in the view of problems and improvement of the law and safety awareness of people.

  • PDF

Ondol Heating System Using Heat Pump - Comparison of Energy Consumption between the Heat Pump and the Oil Boiler - (열펌프를 이용한 온돌 난방 시스템 - 열펌프와 석유보일러의 소요에너지 비교 -)

  • 김현철;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.351-358
    • /
    • 1999
  • In these days, we are faced to a couple of difficult problems, the one is the unstable price of the energy due to the shortage of fossil fuel resources and the other is the serious environmental pollution from the excessive consumption of fossil fuel. In order to save the thermal energy for the house heating, in this study the heat pump using the natural thermal energy resources was provided for Ondol heating and the thermal energy consumption of the heat was compared to that of oil boiler. The results could be summarized as follows: 1. In the Ondol room the temperature difference between the Ondol surface and room air was about 5∼$10^{\circ}C$ in accordance with the ambient temperature. 2. The Ondol room heating efficiency of the heat pump with compressor of 2PS was the highest at the water flow rate of 200 l/h. 3. The energy saving rate of the heat pump to the oil boiler for heating the Ondol system was 19.3%. 4. The Ondol heating cost of the heat pump was less 20.6% than that of oil boiler when oil price was 478 won/l.

  • PDF

Prediction of Possibility of Indoor Pipe Freezing in Heat Only Boiler Room through Thermal Analysis (열분석을 통한 열전용 보일러동 실내배관의 동파 가능성 예측)

  • Lim, Byoung-Ik;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.19-28
    • /
    • 2012
  • In a heat only boiler system of a steam power plant, outdoor air required for combustion is made to pass through indoor space for increasing the boiler efficiency. Due to heat generated by various equipments, temperature of the air that enters the boiler will increase resulting in combustion efficiency. If the outdoor air temperature is low, however, this will cause freezing and bursting of pipes which are filled with water. It is especially fatal to small diameter pipes and pipes connected to measuring instruments. The purpose of this study is find operation and outdoor conditions where this phenomena can happen and also establish preventive measures to avoid this problem.

Thermal Stress Evaluation by Elastic-Creep Analysis during Start-up of Boiler Header (보일러 헤더 기동시의 탄성 크리프 해석에 의한 열응력 평가)

  • Shin, Kyu-In;Yoon, Kee-Bong
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.17-22
    • /
    • 2009
  • Thermal stress and elastic creeping stress analysis was conducted by finite element method to simulate start-up process of a boiler header of 500MW standard fossil power plant. Start-up temperature and operating pressure history were simplified from the real field data and they were used for the thermal stress analysis. Two kinds of thermal stress analysis were considered. In the first case only temperature increase was considered and in the second case both of temperature and operating pressure histories were considered. In the first analysis peak stress was occurred during the temperature increase from the room temperature. Hence cracking or fracture may occur at the temperature far below the operating maximum temperature. In the results of the second analysis von Mises stress appeared to be higher after the second temperature increase. This is due to internal pressure increase not due to the thermal stress. When the stress components of radial(r), hoop($\theta$) and longitudinal(z) stress were investigated, compression hoop stress was occurred at inner surface of the stub tube when the temperature increased from room temperature to elevated temperature. Then it was changed to tension hoop stress and increased because of the operating pressure. It was expected that frequent start-up and shut-down operations could cause thermal fatigue damage and cracking at the stub tube hole in the header. Elastic-creeping analysis was also carried out to investigate the stress relaxation due to creep and stabilized stress after considerable elapsed time. The results could be used for assessing the creep damage and the residual life of the boiler header during the long-tenn service.

Development of an Anti-Freezing Heating Cable Temperature Controller and Its Power Saving Effects Analysis (동파방지 발열선용 온도제어기 개발 및 전기에너지 절감 효과 분석)

  • Lee, Kihong;Lee, Jaejin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.101-106
    • /
    • 2014
  • Although anti-freezing heating cable has been widely installed in most residential boiler pipe, there were excessive energy consumption and fire risk due to inadequate temperature control. In this paper, a new energy saving fire risk-free controller was developed by using microprocessing operation which include detection of not only boiler room temperature but also pipe surface one. Its actual effect has been verified to save more than a half of the energy consumption comparing to conventional controller through temperature and humidity chamber experiment.

Development of the simulator for marine auxiliary boiler system (선박용 보조 보일러 시스템 시뮬레이터 개발)

  • Kim, Myoung-Hwan;So, Myung-Ok;Jung, Byung-Gun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.236-241
    • /
    • 2013
  • It requires long time and high cost for an apprentice engineer to reach the level of getting various experiences of engine space machinery and preparing for emergency situations. Therefore reducing the time and cost, several types of simulator that give the very similar surroundings to the ship engine room, relevant to STCW-95 are used for systematic education and training to get many experiences and good judgement in emergency. Since most simulators that are operated in Korea were imported from foreign countries, it is difficult to directly implant the amendments of STCW Convention and reflect International Maritime Organization (IMO) model courses. This study describe a development of marine auxiliary boiler simulator that makes the apprentice engineer easier to understand the relationship between equipments in steam system such as auxiliary boiler, exhaust gas boiler, and steam turbine.

A Study on the Mechanical Property and Microstructure of SA213 P92 Boiler Pipe Steel (보일러 배관용 P92 파이프강의 기계적 특성 및 미세조직에 관한 연구)

  • Kim, Beom Soo;Son, Tae Ha;Min, Taek Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.777-783
    • /
    • 2012
  • The hardness and strength test was performed to make the manufacturing process of SA213 P92 boiler pipe steel. And the microstructure change was studied to find out the cause of room temperature property of P92 steel, ie, low hardness and strength property. The room temperature property of P92 steel depends on the improper normalizing and cooling rate. Especially, Ferrite was formed and the steel had low hardness when the temperature was decreased slowly under the cooling rate $1^{\circ}C$/min after normalizing at the temperature around $A_{c1}$ to $A_{c3}$. The critical heat treatment temperature and cooling rate was over $900^{\circ}C$ and over $10^{\circ}C$/min to satisfy the minimum yield and tensile stress which was laid down by ASME Code.

Heating Characteristics of Ondol using Heat Pump-Latent Heat Storage System (열펌프-잠열축열시스템을 이용한 온돌의 난방특성)

  • Kim, M.H.;Song, H.K.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2000
  • In these days the hot water circulating Ondol using the fossil fuel boiler is the heating system for the most of the Korean residents. Then it is installed without the heat storage medium in the Ondol heating layer, but the Korean traditional Ondol had been composed with the heat storage medium. The Ondol room without heat storage medium could not be comfortable because the room air temperature is not only changed unstably but also it has a defect too much fuel consumption. Therefore in this study the heat pump-latent heat storage Ondol as the new type of Ondol system was developed to solve these problems mentioned above, and the COP of the heat pump (Coefficient Of Performance), the latent heat storage characteristics in the new type of Ondol system and the temperature variation in the Ondol room with the ambient temperature were analyzed.

  • PDF