• Title/Summary/Keyword: Boiler Performance

Search Result 258, Processing Time 0.025 seconds

A study of SO2 Removal Efficiency from Traditional Herbal Medicine Using Traditional & Electronic Medicine Boilers (전통약탕기와 전자약탕기를 이용한 이산화황 제거효율 연구)

  • Yang, Seung-Hee;Ryu, Seok-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1133-1140
    • /
    • 2009
  • The purpose of this study is to determine the most efficient method of removing sulfur dioxide from traditional herbal medicine (hanyak) by slow boiling using a traditional pipkin and an electronic slow boiler. By boiling a hanyak batch containing] 56.4ppm of sulfur dioxide for one hour using a traditional pipkin, 96.7 percent of the sulfur dioxide was removed, while two hours of slow boiling removed ]00 percent. Among different cover materials placed over the pipkin during the slow boiling process including the traditional Korean paper (hanji), regular hanji, filter paper and regular paper, the traditional hanji produced the best performance of sulfur dioxide removal. The initial pH level of the traditional hanji was] 0.03. After one hour of slow boiling hanyak batches in a traditional pipkin covered with traditional hanji, where each batch contained sulfur dioxide of 48ppm, 193ppm, 753ppm and 1,506ppm respectively, the pH level of the hanji cover material was reduced to 9.37, 9.14, 8.9 and 8.03 in respective cases. Our experiment using an electronic medicine slow boiler showed 82.8 percent removal of sulfur dioxide after one hour of slow boiling a hanyak batch containing 753ppm of sulfur dioxide. When hanyak batches were boiled by placing traditional hanji, filter paper, active carbon and hardwood charcoal separately in the middle area within the electronic slow boiler, the sulfur dioxide removal rate was 73.6 percent, 72.8 percent, 73.9 percent and 69.5 percent, respectively. When charcoal was added so as to remove toxic materials from the hanyak, its presence impeded the sulfur dioxide flow and thus reduced the removal efficiency contrary to our anticipation.

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

A Study on Optimal Operation for Soot Blower of Power Plant (발전용 Soot Blower 최적운전에 관한 연구)

  • Kim, Sung-Ho;Jung, Hae-Won;Yook, Sim-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.541-543
    • /
    • 2004
  • An optimal soot blowing system has been developed for an optimal operation of power utility boilers by both minimization of the use of steam and the number of soot blowers worked during soot blowing. Traditionally, the soot blowing system has been operated manually by operators. However, it causes the reduction of power and thermal performance degradation because all soot blowers installed in the plant should be worked simultaneously even there are lots of tubes those are not contaminated by slagging or fouling. Heat transfer area is divided into four groups, furnace, convection area including superheater, reheater and economizer, and air preheater in the present study. The condition of cleanness of the tubes is calculated by several parameters obtained by sensors. Then, a part of soot blowers works automatically where boiler tubes are contaminated. This system has been applied in a practical power plant. Therefore, comparison has been done between this system and manual operation and the results are discussed.

  • PDF

A Study on Low Emission Pulverized Coal Combustion in the 2 Staged Coaxial Cyclone Combustor (2단 동축형 Cyclone 연소기를 이용한 저공해 미분탄 연소특성 연구)

  • Choi, Sang-Il;Park, Chu-Sik;Kim, Sung-One;Kim, Ho-Young
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.67-83
    • /
    • 1999
  • The objective of this study is development of low emission pulverized coal combustor for reducing pollutant emission generated from coal combustion. Low emission combustion technology for reducing NOx and fly ash was investigated by using 2 stage coaxial cyclone combustor. Staged combustion was employed for NOx reduction and high temperature slagging combustion was also studied for fly ash removal in the combustor. The result of this study shows that the low emission combustion system can reduce the amount of atmospheric pollutions with improved boiler efficiency and performance.

  • PDF

Numerical Simulation for Flow Optimization of De-NOx Selective Catalytic Reactor (배가스 탈질 설비의 유동해석 사례)

  • Go, Young-Gun;Ryu, Chang-Kook;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.99-105
    • /
    • 2001
  • For the design of selective catalytic reactors of NOx by $NH_3$, engineering approach can be performed to determine the reactor shape, mixing device and $NH_3$ injection system. This study shows the optimization of guide vanes to improve the flow pattern near the catalyst layer of SCR in a untility boiler. By varying their spacings and shapes, flow performance of guide vanes was analyzed to achieve an uniform velocity distribution which increases the NOx convesion efficiency, and a flow direction normal to the layer which minimises the erosion by the dust in the flue gas. Including these results, experimental and numerical studies for the SCR design were discussed.

  • PDF

Fuzzy self-organizing controller for the industrial boiler system (보일러 제어를 위한 퍼지 자기구성 제어기의 설계)

  • 박태홍;배상욱;박귀태;이기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.737-741
    • /
    • 1993
  • In this paper, we design the fuzzy logic controller(FLC) for a nonlinear multivariable steam generating unit. Based on the knowledges of operator, the self-organizing controller(SOC) - a kind of FLC - is developed and tested. Both FLC and SOC based on linguistic rules have the advantages of not needing of some exact mathematical model for plant to be controlled. Beside, the SOC modifies the existing control rules by monitoring the control performance. The computer simulations have been carried out for the 200MW steam generating unit to show the usefulness of the proposed method and the effects of disturbances and parameter variations are considered.

  • PDF

An Experimental Study on the Load Delivery Characteristics of Hybrid Energy System with Geothermal and Solar Heat Sources (지열-태양열원 복합시스템의 부하추종특성에 관한 실험 연구)

  • Hwang, In-Ju;Woo, Nam-Sub
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.2 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of the present study is to investigate the load delivery characteristics of a hybrid-renewable energy system with geothermal and solar heat sources for hot water, heating and cooling of a residential house in Korea. The hybrid energy system consists of ground source heat pump of 2 RT for cooling with a 150 m vertical U-bend ground heat exchanger, solar collectors of 4.8 m2 and gas fired backup boiler. The averaged coefficient of performance of geothermal module during cooling and heating seasons are evaluated as about 4.5 and 3.8, respectively.

  • PDF

LCC Analysis of a Heat Pump System Using River Water (하천수 열원 이용 열펌프 시스템의 LCC 분석)

  • Han, Sang-Soo;Park, Cha-Sik;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1424-1428
    • /
    • 2009
  • The performance of a heat pump using river water as a heat source was compared with that of a conventional air-conditioner for cooling and a boiler system for heating. The heat pump system using river water considered the 1-stage cycle for cooling and the 2-stage cycle for heating. The COPs of the river water source heat pump were $0.5{\sim}1.1$ higher than those of the conventional system in the cooling season. The LCC of the river water source heat pump system was lower 13.5% and 32.4% than that of the conventional system I and II. In addition, when the initial cost ratios of the river water source heat pump system to the conventional system I and II were less than 1.2 and 1.4, respectively, an acceptable payback was found to be less than 5 years.

  • PDF

Improvement of a PID Function Block of a Domestic DCS (국산 분산 제어 시스템의 PID 기능 블럭 개선)

  • 변승현;마복렬
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.151-154
    • /
    • 2000
  • Used analog control systems have been converted into digital control systems due to performance degradation and difficulty of maintenance. There are few domestic DCS (Distribued Control System)s that have been applied to Bower plant. To apply a demestic DCS to power plant, the reliability, redundacny, and fault tolerance of DCS is important. Besides those items, the control action of control function block is also important. In this paper, we describe the requirements that PID control function block has to have, and implement a PID control function block that satisfies those requirements. Finally. simulation result using digital simulator for boiler system in thermal power plant shows the validity of a implemented PID control function block.

  • PDF

The Development of monitoring system for demonstration research of solar hot water heater for dwellings (실증연구를 위한 주택용 태양열 온수기 모니터링 시스템 개발)

  • 양동조;김재열;한재호;송경석;김우진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.156-161
    • /
    • 2004
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF