• Title/Summary/Keyword: Body surface scan

Search Result 70, Processing Time 0.025 seconds

Analysis of Body Surface Area by Fitness Motion Using 3D Scan Data of Korean Elderly Female (한국 여성 노인 3D 스캔 데이터를 활용한 피트니스 동작별 체표면적 분석)

  • Jeon, Eun-Jin;Jung, Ha-young;Kim, Hee-Eun;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.650-659
    • /
    • 2020
  • The present study provides reference data required for the design of clothing for the elderly by analyzing the body surface area during fitness motion based on 3D scan data of Korean elderly women. This study was conducted with the procedures of (1) survey of motions and main muscles for fitness, (2) acquisition of 3D scan data, and (3) analysis of rate of change for body surface area during fitness motion. Acquisition of 3D body scan data was obtained from seven elderly females (age: 64-77). We selected 66 anatomical landmarks (40 upper body and 22 lower body) by referring to previous studies. Body surface was segmented by connecting the landmarks marked on the 3D scan data acquired. Analysis of body surface area was conducted in terms of the change rate of surface area in 9 postures of elbow 0°, 90° and 180° for flexion, shoulder 90°, 180° for flexion, shoulder 0°, 180° for abduction, hip 90° for flexion, and knee 90° for flexion compared to the those in the standing posture. The amount of changes in body surface area were 12%-62% in the upper body, 15%-77% in the arm, and 10%-51% in the lower body. A future study on the rate of change of body surface length is needed; in addition, a study on how to apply the results of body surface area and body surface length analysis to clothing pattern design is also necessary.

A study of the variations by motion of the Lower body Using 3D Body Surface Scan Data of a man in his early twenties (3차원 스캐너를 이용한 20대 남성의 하반신 신축량 분석)

  • Sohn, Boo-Hyun;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.18 no.3
    • /
    • pp.729-740
    • /
    • 2009
  • This study is to research on the rate of expansion or contraction according to movement of the lower body of the man their twenties using Rapid Form software. And aim of this study is to get information of ease allowance in developing slacks pattern using 3D body surface scan data through comparison with existing slacks patterns. Considering on the contraction and expansion according to movement, it need to set the more ease allowance in hip circumference than waist circumference, and the more ease allowance in back hip width than front hip width in slacks. In crotch length, the length of front crotch is revealed contraction but the length of back crotch is revealed expansion. It is desirable lowering front waist line and raising back waist line to possess ease allowance in back crotch area. The length of side seam is revealed a little expansion but the length of inseam is showed a great expansion. To develop slacks pattern of scientific approach using 3D body surface scan data, it need to analysis the rate of expansion and contraction of the lower body based on the movement, shear deformation, slip in fabrics and skin, or in fabrics and fabrics, and slip down from waist line.

2D Pattern Development of Body Surface from 3D Human Scan Data Using Standing and Cycling Postures (3D 스캔을 이용한 사이클 동작 전후 체표 변화 고찰 및 2D 전개 패턴의 비교)

  • Jeong, Yeonhee;Lee, Yejin
    • Korean Journal of Human Ecology
    • /
    • v.21 no.5
    • /
    • pp.975-988
    • /
    • 2012
  • Although the pattern development for tight-fitting clothing has been carried out using 3D data on humans, the pattern development using 3D scan data obtained for various postures still remains an interesting subject. In this study, we have developed the 2D pattern using the 3D human body reflecting standing and cycling postures. The 3D scan data of a subject was obtained using Cyberware. 2C-AN program(Triangle simplification and the Runge-Kutta method) was used in the system to reduce the 3D scan data points and to make segmented triangular patches in a plane from 3D data. As results, surface distance and area of each body part of standing and cycling postures were also provided for the future application of the functional clothing construction. The area of center piece on the front (c.front) decreased by $106.45cm^2$(-13.08%) and that of lateral piece(s.back) on the back increased by $144.96cm^2$(18.69%) in the patterns of cycling posture. The girth of neck and waist for the cycling posture increased by 0.88cm (3.92%) and 1.56cm(4.40%) respectively, and the that of thigh decreased by 1.01cm(-2.24%). The differences between the area in the 2D pattern obtained from the 3D scan data and that in the 3D scan surface data for standing and cycling postures were very small($-10.34cm^2$(-0.32%) and $-44.33cm^2$(-1.32%)).

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

A Study on the Use of 3D Human Body Surface Shape Scan Data for Apparel Pattern Making (의류 패턴 설계를 위한 삼차원 인체 체표면 스캔 데이터 활용에 관한 연구)

  • 천종숙;서동애;이관석
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.6
    • /
    • pp.709-717
    • /
    • 2002
  • In the apparel industry, the technology has been advanced rapidly. The use of 3D scanning systems fur the capture and measurement of human body is becoming common place. Three dimensional digital image can be used for design, inspection, reproduction of physical objects. The purpose of this study is to develop a method that drafts men's basic bodice pattern from scanned 3D body surface shape data. In order to pursue this purpose the researchers developed pattern drafting algorithm. The 3D scanner used in this study was Cyberware Whole Body Scanner WB-4. The bodice pattern drafting algorithm from 3D body surface shape data developed in this study is as follows. First, convert geometric 3D body surface data to 3D polygonal mesh data. Second, develop algorithm to lay out 3D polygonal patches onto a plane using Auto Lisp program. The polygon meshes are coplanar, and the individual mesh is continuously in contact with next one The bodice front surface shape data in polygonal patches form was lined up in bust and waist levels. The back bodice was drafted by lining up the polygonal mesh in scapula, chest, and waist levels. in the drafts, gaps between polygons were formed into the darts.

  • PDF

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

A Study of Shirts' Patternmaking Based on 3D Body Surface Changes in Golf Swing Postures (골프 스윙 자세의 체표면 변화 특성을 반영한 셔츠 패턴 설계 연구)

  • Oh, Seol-Young;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.5
    • /
    • pp.1049-1060
    • /
    • 2011
  • The purpose of this study was to develop a shirt pattern that enhances the functionality of golf swing motions. The pattern was made with 3D body surface shape data that changed according to dynamic golf postures. The data were collected from the golf swing motions. The 3D body surface data in golf swing postures piled up on the 3D surface data in a static posture. The results showed that the surface shape data changed more in the address, back swing, and finish postures than the other swing postures. The experimental pattern was developed with 3D surface scan data in those three golf swing motions. The pattern had raglan sleeves and the front-bodied piece was divided into two pieces with a princess line, which comes from armscye line of the address posture. The back bodice piece was divided into three pieces with a yoke line and a back princess line. The yoke line was made by back shoulder shape in the back swing posture. The level of comfort of the experimental garment and commercial golf shirts was evaluated by 38 women golfers. The experimental garment pattern was evaluated to be more comfortable in golf swing postures than commercial golf shirts.

Development of Male Fitted Torso Type Basic Patterns According to the Body Surface Segment Method (체표면분할법에 의한 성인 남성용 피티드 토르소형 원형 설계)

  • Suh, Chu-Yeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.7
    • /
    • pp.1109-1120
    • /
    • 2009
  • This study develops a fitted torso type basic pattern for men by utilizing 3D body scan data. Recent fashion trends are reflected in the development of the pattern. The subjects were 15 men in their 20's, who wear size 95 (M size). Body scan data was obtained through a 3D whole body scanner (WB4, Cyberware, USA), and a body surface development figure for developing male fitted torso type basic pattern was attained through the use of Rapid Form 2006 as well as Auto CAD 2006 programs. The results are as follows: A body surface development figure through body surface segment method showed high exactitude in an error range of 100$\pm$1%. In addition, it occurred in an error range of 100:1:3% because of the hard scanning conditions in the incline of the shoulder and armpit areas. However, the body surface development figure as well as the direct measurement results can be used as basic data for the given patternmaking since the error range falls into 100$\pm$3%. Dart amounts obtained from the average cross section were center back 2.2cm (24.3%), back armpit point 3.8cm (41.8%), front armpit point 3.0cm (33.9%). As shown the jacket pattern, the biggest dart amount was portioned out at the back armpit point. The drafting equations for the development pattern acquired are as follows; Full width=C/2+5cm, back length=height/4-1cm, armhole depth=(C/10+12cm)+3cm, back width=2C/10+2cm, front width=2C/10. The development pattern was a fitted torso basic pattern that was composed of 3 pieces, so it would be very useful in developing shirt or jacket patterns. According to the results of the evaluation of the developed pattern appearance, it obtained higher scores of over 3.5 points in almost items, meaning that the developed pattern is appropriate for a male fitted torso type basic pattern. It suggests a possibility of patternmaking from a body surface development figure in 2-D to prototype.

3D Body Scan Data Analysis for the Slim-fit Dress Shirts Pattern Design -Focused on the 40s Male- (슬림 핏(Slim-fit) 드레스 셔츠 패턴 설계를 위한 3D Body Scan Data 활용에 관한 연구 -40대 남성을 중심으로-)

  • Shin, Kyounghee;Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.1
    • /
    • pp.97-109
    • /
    • 2014
  • This study developed a functional dress shirt for adult males that reflected the body surface variation of a human body section by motion. This study conducted a 3D body scan for 8 subjects in their 40's based on the Size Korea 2010 database. Data recorded the proper posture change value and body surface change value to develop functional dress shirts for adult males. We scanned the subjects with a 3D body scanner for five primarily male wearing dress shirts and operating postures, right standing, arms raised to $90^{\circ}$ horizontal forward position, arms raised $90^{\circ}$ to the horizontal position side, lift up the arm $180^{\circ}$, and arm forward $90^{\circ}$ in a bent posture. We analyzed the 3D scan data from those motions to examine change of length using 3D software Rapidform XOS. The results indicated that the body surface sections with contraction were the front and rear shoulder area, armpit and central length as well the width of arms at more than 10%. The increased body section included the body and armpit back length; in addition, the rear arm vibration girth and under arm girth were more than 10%. In order to reflect the size variation of for each motion, the ease amount of the front and rear shoulder length and width needs to be reduced 20% because it affects the shoulder length during the right standing. The results suggest that the ease amount of the shoulder length should be minimal. The ease amount of the back size needs to be 0.5-2cm bigger and set 0.5-1.5cm longer than the dress shirt length side drooping to compensate for the side length shortage of each motion. The sleeve length needs to be 0-0.5cm shorter, and ease amount of the girth of sleeve bottom needs to be reduced 0-0.7cm due to the size variation of arms. However, the girth of the rear arms is suggested to be 0-0.6cm longer in the ease amount to the rear arm girth as the extension is more than 10% over the width and length of each motion.