• Title/Summary/Keyword: Body segment

Search Result 304, Processing Time 0.027 seconds

(Community Care Preparation) Identification of Musculoskeletal Problems for the Elderly in Rural Areas and Presentation of Regional and Inter-university Health Management Models

  • Sung-hak Cho
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.2
    • /
    • pp.37-42
    • /
    • 2023
  • Purpose: Compared to cities, rural areas are in a medical blind spot and face difficulties in accessing medical services due to inconvenient transportation facilities, lack of medical facilities, and the heavy burden of medical expenses. This study was carried out to identify the problems relating to the musculoskeletal system of the elderly in rural and fishing villages, which are medically vulnerable areas, and sought to present a regionally differentiated healthcare model. Methods: The study was conducted in 80 elderly people in two rural villages and two fishing villages after seeking inputs regarding medically vulnerable groups in the Gyeongnam Province. Postural balance and muscle flexibility were assessed and postural evaluation was conducted to identify musculoskeletal problems and gait stability. Strength and range of motion for each body segment were assessed for evaluating functional motion. Results: The elderly in both rural areas showed forward head posture characteristics. The strength level of the elderly in both rural areas was higher than the average, but their flexibility and balance ability were lower than the average. Conclusion: The musculoskeletal problems of the elderly in rural and fishing villages in this study did not show regional characteristics according to the area of residence. However, overall flexibility and balance ability appeared to be reduced. Therefore, a new management model connecting the region and the university is necessary in preparation for the coming era of community care.

Water Detection in an Open Environment: A Comprehensive Review

  • Muhammad Abdullah, Sandhu;Asjad, Amin;Muhammad Ali, Qureshi
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • Open surface water body extraction is gaining popularity in recent years due to its versatile applications. Multiple techniques are used for water detection based on applications. Different applications of Radar as LADAR, Ground-penetrating, synthetic aperture, and sounding radars are used to detect water. Shortwave infrared, thermal, optical, and multi-spectral sensors are widely used to detect water bodies. A stereo camera is another way to detect water and different methods are applied to the images of stereo cameras such as deep learning, machine learning, polarization, color variations, and descriptors are used to segment water and no water areas. The Satellite is also used at a high level to get water imagery and the captured imagery is processed using various methods such as features extraction, thresholding, entropy-based, and machine learning to find water on the surface. In this paper, we have summarized all the available methods to detect water areas. The main focus of this survey is on water detection especially in small patches or in small areas. The second aim of this survey is to detect water hazards for unmanned vehicles and off-sure navigation.

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Biomechanical Comparative Analysis of Two Goal-kick Motion in Soccer (두 가지 축구 골킥 동작의 운동역학적 비교 분석)

  • Jin, Young-Wan;Shin, Je-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.29-44
    • /
    • 2005
  • The purpose of this study is to reveal the effects of two different kicks, the drop kick and the punt kick, into the kicking motion, through the kinetic comparative analysis of the kicking motion, which is conducted when one kicks a soccer goal. To grasp kinetic changing factors, which is performed by individual's each body segment, I connected kicking motions, which were analyzed by a two dimension co-ordination, into the personal computer to concrete the digits of it and smoothed by 10Hz. Using the smoothed data, I found a needed kinematical data by inputting an analytical program into the computer. The result of comparative analysis of two kicking motions can be summarized as below. 1. There was not a big difference between the time of the loading phase and the time of the swing phase, which can affect the exact impact and the angle of balls aviation direction. 2. The two kicks were not affected the timing and the velocity of the kicking leg's segment. 3. In the goal kick motion, the maximum velocity timing of the kicking leg's lower segment showed the following orders: the thigh(-0.06sec), the lower leg(-0.05sec), the foot(-0.018sec) in the drop kick, and the thigh(-0.06sec), the lower leg(-0.05sec), the foot(-0.015sec) in the punt kick. It showed that whipping motion increases the velocity of the foot at the time of impact. 4. At the time of impact, there was not a significant difference in the supporting leg's knee and ankle. When one does the punt kick, the subject spreads out his hip joint more at the time of impact. 5. When the impact performed, kicking leg's every segment was similar. Because the height of the ball is higher in the punt kick than in the drop kick, the subject has to stretch the knees more when he kicks a ball, so there is a significant affect on the angle and the distance of the ball's flying. 6. When one performs the drop kick, the stride is 0.02m shorter than the punt kick, and the ratio of height of the drop kick is 0.05 smaller than the punt kick. This difference greatly affects the center of the ball, the supporting leg's location, and the location of the center of gravity with the center of the ball at the time of impact. 7. Right before the moment of the impact, the center of gravity was located from the center of the ball, the height of the drop kick was 0.67m ratio of height was 0.37, and the height of the punt kick was 0.65m ratio of height was 0.36. The drop kick was located more to the back 0.21m ratio of height was 0.12, the punt kick was located more to the back 0.28m ratio of height was 0.16. 8. There was not a significant difference in the absolute angle of incidence and the maximum distance, but the absolute velocity of incidence showed a significant difference. This difference is caused from that whether players have the time to perform of not; the drop kick is used when the players have time to perform, and punt kick is used when the players launch a shifting attack. 9. The surface reaction force of the supporting leg had some relation with the approaching angle. Vertical reaction force (Fz) showed some differences in the two movements(p<0.05). The maximum force of the right and left surface reaction force (Fx) didn't have much differences (p<0.05), but it showed the tendency that the maximum force occurs before the peak force of the front and back surface (Fy) occurs.

Study on body measurement of fetuses and neonates in Korean native goats (한국재래산양(韓國在來山羊)의 태아(胎兒) 및 신생자(新生仔)의 체적측정치(體尺測定値)에 관(關)한 연구(硏究))

  • Kim, Chong-sup;Choe, Sang-yong;Chung, Hyon-sik;Kim, Taeg-seog
    • Korean Journal of Veterinary Research
    • /
    • v.28 no.2
    • /
    • pp.213-219
    • /
    • 1988
  • The measurement was investigated with 18 heads of fetus(60, 90, 120 days of gestation) and neonate in Korean native goats. The results were summerized as follows: 1. The crown-rump length of fetuses at 60, 90, 120 days of gestation and neonate was 8.71, 20.83, 31.10 and 34.93 cm, respectively. 2. The length of small intestine at 60, 90, 120 days of gestation and neonate was 32.28, 157.10, 303.52 and 457.06 cm, respectively. 3. The length of large intestine at 60, 90, 120 days of gestation and neonate was 9.20, 37.70, 82.06 and 94.46 cm, respectively. 4. The ratio of intestinal length to crown-rump length at 60, 90, 120 days of gestation and neonate was 4.76, 9.45, 12.40 and 15.79 times, respectively. 5. At 60 days of gestation, the total length of the vertebral column was $7.40{\pm}0.72cm$, The mean length of each segment of the vertebral column was $1.55{\pm}0.20cm$ in cervical, $2.29{\pm}0.21cm$ in thoracic, $1.46{\pm}0.10cm$ in lumbar, $0.51{\pm}0.04cm$ in sacral and $1.59{\pm}0.17cm$ in coccygeal vertebrae. 6. At 90 days of gestation, the total length of the vertebral column was $16.52{\pm}0.80cm$. The mean length of each segment of the vertebral column was $3.72{\pm}0.12cm$ in cervical, $5.09{\pm}0.26cm$ in thoracic, $3.22{\pm}0.04cm$ in lumbar, $1.97{\pm}0.03cm$ in sacral and $2.64{\pm}0.35cm$ in coccygeal vertebrae. 7. At 120 days of gestation, the total length of the vertebral column was $26.35{\pm}0.34cm$. The mean length of each segment of the vertebral column was $6.09{\pm}0.16cm$ in cervical, $7.81{\pm}0.07cm$ in thoracic, $5.08{\pm}0.07cm$ in lumbar, $3.07{\pm}0.02cm$ in and $4.31{\pm}0.02cm$ in coccygeal vertebrae. 8. In the neonate, the total length of the vertebral column was $32.41{\pm}1.57cm$. The mean length of each segment of vertebral was $7.70{\pm}0.25cm$ in cervical, $9.97{\pm}0.68cm$ in thoracic, $5.58{\pm}0.44cm$ in lumbar, $3.85{\pm}0.15cm$ in sacral and $5.05{\pm}0.06cm$ coccygeal vertebrae. 9. The chest girth at 60, 90, 120 days of gestation and neonate was $6.13{\pm}0.51$, $13.45{\pm}0.84$, $20.28{\pm}1.53$ and $22.94{\pm}1.75cm$, respectively. 10. The head length at 60, 90, 120 days of gestation and neonate was $2.93{\pm}0.07$, $6.67{\pm}0.13$, $8.84{\pm}0.51$ and $9.76{\pm}0.44cm$, respectively. 11. The width of the head at 60, 90, 120 days of gestation and neonate was $2.20{\pm}0.13$, $4.45{\pm}0.11$, $5.33{\pm}0.20$ and $5.51{\pm}0.32cm$, respectively.

  • PDF

A Morphologic Study of Sasang Constitution (사상인(四象人)의 형태학적(形態學的) 특징(特徵)에 관(關)한 연구(硏究))

  • Lee, Eui-ju;Kho, Byung-hee;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.181-220
    • /
    • 1998
  • 1. PURPOSE This is a quantitative analysis of Sasang Constitution by measuring human body except face. This study is carried out for the purpose of searching out the theory of Sa-cho and the morphologic theory of Sasang Constitution. 2. METHOD (1) SUBJECTS Subjects are 338 person came to Dept. of Sasang Constitutional Medicine (KyungHee Oriental Medical Center) and Oriental Medicine and Western Medicine Cooperative Health Examination Center (KyungHee Medical Center) from October 1997 to Jauary 1998. The mean age is $41.7{\pm}12.39$. (2) CLASSIFICATION OF SASANG CONSTITUTION QSCCII(Questionnaire for the Sasang Constitution Classification) is used for the Classification of Sasang Constitution. The distributions of Sasang Constitution Classification are Soeumin 83, Soyangin 98, and Taeumin 157. (3) MEASURING INSTRUMENT & ITEMS Length, Breadth, Circomferece, and Skinfold thickness of each body segment are measured by Martin's measuring instrument and Skinfold Caliper. Measured items of this study is based on Lohman's methods and is added new items. (4) DATA ANALYSIS The Volume, Weight, Rate, and Index of each group are calculated by using measuring items. The difference of each group is analyzed by SPSS 7.0 for Win. 3. RESULT (1) THE MORPHOLOGIC CHARACTERISTIC of TAEUMIN First of all, the Taeumin has a emormous morphology. His trunk is huge but head-neck and limbs is small. The volume and weight of head-neck is smaller than other body segments but the volume and weight of upper-abdomen is bigger than ones. (2) THE MORPHOLOGIC CHARACTERISTIC of SOEUMIN The Soeumin has a small morphology. His head-neck rate is bigger than Taeumin's but his trunk rate is smaller than Taeumin's. And his lower limbs rate is bigger than other constitution but it's not a significant difference. His neck is thinest and longgest than others. His chest is thin and narrow. His lower-abdomen rate is bigger than other constitution but it's difference is not significant. (3) THE MORPHOLOGIC CHARACTERISTIC of SOYANGIN Soyangin has a middle size at head-neck and chest part. But the rate of upper limb is higer than other constitution. And the rate of lower-abdomen part is lower than other constitution. but that's not significant.

  • PDF

Load Sharing Mechanism Across Graft-Bone Interface in Static Cervical Locking Plate Fixation

  • Han, In-Ho;Kuh, Sung-Uk;Chin, Dong-Kyu;Jin, Byung-Ho;Cho, Yang-Eun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.213-218
    • /
    • 2009
  • Objective : This study is a retrospective clinical study over more than 4 years of follow up to understand the mechanism of load sharing across the graft-bone interface in the static locking plate (SLP) fixation compared with non-locking plate (NLP). Methods : Orion locking plates and Top non-locking plates were used for SLP fixation in 29 patients and NLP fixation in 24 patients, respectively. Successful interbody fusion was estimated by dynamic X-ray films. The checking parameters were as follows : screw angle (SA) between upper and lower screw, anterior and posterior height of fusion segment between upper and lower endplate (AH & PH), and upper and lower distance from vertebral endplate to the end of plate (UD & LD). Each follow-up value of AH and PH were compared to initial values. Contributions of upper and lower collapse to whole segment collapse were estimated. Results : Successful intervertebral bone fusion rate was 100% in the SLP group and 92% in the NLP group. The follow-up mean value of SA in SLP group was not significantly changed compared with initial value, but follow-up mean value of SA in NLP group decreased more than those in SLP group (p=0.0067). Statistical analysis did not show a significant difference in the change in AH and PH between SLP and NLP groups (p>0.05). Follow-up AH of NLP group showed more collapse than PH of same group (p=0.04). The upper portion of the vertebral body collapsed more than the lower portion in the SLP fixation (p=0.00058). Conclusion : The fused segments with SLP had successful bone fusion without change in initial screw angle, which was not observed in NLP fixation. It suggests that there was enough load sharing across bone-graft interface in SLP fixation.

The Evolution of Flow-Diverting Stents for Cerebral Aneurysms; Historical Review, Modern Application, Complications, and Future Direction

  • Shin, Dong-Seong;Carroll, Christopher P.;Elghareeb, Mohammed;Hoh, Brian L.;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.137-152
    • /
    • 2020
  • In spite of the developing endovascular era, large (15-25 mm) and giant (>25 mm) wide-neck cerebral aneurysms remained technically challenging. Intracranial flow-diverting stents (FDS) were developed to address these challenges by targeting aneurysm hemodynamics to promote aneurysm occlusion. In 2011, the first FDS approved for use in the United States market. Shortly thereafter, the Pipeline of Uncoilable or Failed Aneurysms (PUFS) study was published demonstrating high efficacy and a similar complication profile to other intracranial stents. The initial FDA instructions for use (IFU) limited its use to patients 22 years old or older with wide-necked large or giant aneurysms of the internal carotid artery (ICA) from the petrous segment to superior hypophyseal artery/ophthalmic segment. Expanded IFU was tested in the Prospective Study on Embolization of Intracranial Aneurysms with PipelineTM Embolization Device (PREMIER) trial. With further post-approval clinical data, the United States FDA expanded the IFU to include patients with small or medium, wide-necked saccular or fusiform aneurysms from the petrous ICA to the ICA terminus. However, IFU is more restrictive in South Korea than in United States. Several systematic reviews and meta-analyses have sought to evaluate the overall efficacy of FDS for the treatment of cerebral aneurysms and consistently identify FDS as an effective technique for the treatment of aneurysms broadly with complication rates similar to other traditional techniques. A growing body of literature has demonstrated high efficacy of FDS for small aneurysms; distal artery aneurysms; non-saccular aneurysms posterior circulation aneurysms and complication rates similar to traditional techniques. In the short interval since the Pipeline Embolization Device was first introduced, FDS has been firmly entrenched as a powerful tool in the endovascular armamentarium. As new FDS are developed, established FDS are refined, and delivery systems are improved the uses for FDS will only expand further. Researchers continue to work to optimize the mechanical characteristics of the FDS themselves, aiming to optimize deploy ability and efficacy. With expanded use for small to medium aneurysms and posterior circulation aneurysms, FDS technology is firmly entrenched as a powerful tool to treat challenging aneurysms, both primarily and as an adjunct to coil embolization. With the aforementioned advances, the ease of FDS deployment will improve and complication rates will be further minimized. This will only further establish FDS deployment as a key strategy in the treatment of cerebral aneurysms.

Background Removal and ROI Segmentation Algorithms for Chest X-ray Images (흉부 엑스레이 영상에서 배경 제거 및 관심영역 분할 기법)

  • Park, Jin Woo;Song, Byung Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.105-114
    • /
    • 2015
  • This paper proposes methods to remove background area and segment region of interest (ROI) in chest X-ray images. Conventional algorithms to improve detail or contrast of images normally utilize brightness and frequency information. If we apply such algorithms to the entire images, we cannot obtain reliable visual quality due to unnecessary information such as background area. So, we propose two effective algorithms to remove background and segment ROI from the input X-ray images. First, the background removal algorithm analyzes the histogram distribution of the input X-ray image. Next, the initial background is estimated by a proper thresholding on histogram domain, and it is removed. Finally, the body contour or background area is refined by using a popular guided filter. On the other hand, the ROI, i.e., lung segmentation algorithm first determines an initial bounding box using the lung's inherent location information. Next, the main intensity value of the lung is computed by vertical cumulative sum within the initial bounding box. Then, probable outliers are removed by using a specific labeling and the pre-determined background information. Finally, a bounding box including lung is obtained. Simulation results show that the proposed background removal and ROI segmentation algorithms outperform the previous works.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF