• Title/Summary/Keyword: Body reaction

Search Result 1,202, Processing Time 0.031 seconds

Effect of Muscle Function and Muscular Reaction of Knee Joint in the Twenties on the Whole Body Vibration Exercise (전신진동운동이 20대 성인남녀의 슬관절 근기능과 근반응성에 미치는 영향)

  • Kang, Seung Rok;Jeong, Gu Young;Bae, Jong Jin;Min, Jin Young;Yu, Chang Ho;Kim, Jung Ja;Kwon, Tae Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.7
    • /
    • pp.762-768
    • /
    • 2013
  • This study investigated the effect of whole-body vibration on muscle function and muscular reaction in the knee joint. We recruited thirty healthy subjects and divided them into a training group, who experienced whole-body vibration, and a control group, who did not. The training group performed whole-body vibration exercises for 30 min per day, 3 days a week, for 8 weeks. We measured knee joint torque to estimate muscle strength and reaction, using BIODEX System 3. Knee joint peak torque and total work performed increased significantly in the training group, and muscle acceleration time decreased. These results suggest that stimulation by whole-body vibration can improve muscle strength and reaction by improving muscle tone and increasing blood temperature and flow speed in muscular fiber. Our results also indicate that 4 weeks of exercise with whole-body vibration is required to improve the reaction response, and six weeks to improve strength.

Delayed Foreign Body Reaction around the Absorbable Implants in Facial Bone Fracture: A Case Report (안면부 골절에 사용된 흡수성 보형물의 지연성 이물반응: 증례보고)

  • Suh, Yong-Hoon;Kim, Young-Joon
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.875-878
    • /
    • 2011
  • Purpose: Absorbable implants are frequently used to fix facial bone fractures, because they are radiolucent and compatible with magnetic resonance imaging (MRI). Despite their increasing usage, however, there have been few reports about their long-term side-effects. In this paper, a case in which absorbable implants led to a foreign body reaction 17 months after their insertion is presented. Methods: A previously healthy 19-year-old male fell from a flight of stairs and visited the authors' hospital with right periorbital pain. Zygomaticomaxillary fracture involving right orbital floor was detected via a facial bone computed tomography (CT). Internal fixation with absorbable implants was followed by open reduction. 17 months after the surgery, the patient complained of localized periorbital swelling. Removal of the granulomatous lesion including the absorbable implants along with their biopsy and culture was performed. Results: The granulomatous lesion around the implants was firm and extended into the maxillary sinus. The histologic finding showed a microabscess with a foreign body reaction. Methicillin-sensitive Staphylococcus aureus growth was confirmed in the culture. No definite abnormal symptoms ensued after the complete removal. Conclusion: A microabscess-forming granulomatous lesion around the absorbable implant can cause delayed symptomatic foreign body reaction despite its rare occurrence. Complete removal of the lesion including implants is expected to have a successful outcome if it is encountered.

The Development of Aquatic Health Exercise Program for the Old (노인 건강운동 프로그램 개발)

  • Choi Jae-Cheong;Han Dong-Wook;Lee Jeong-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.11-22
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate the effects of aquatic health exercise program for the old. Methods: 20 healthy female with an average age of 71years($71{\pm}4.2$), were participated in this study. The aquatic health exercise program that include warm-up, stretching, strengthening exercise, WATSU and cool-down was performed in the pool two times a week for eight weeks(40min per one session). Body composition, strength of the both knee flexors and extensors, balance ability(sway area and path), whole body reaction time and flexibility(forward reaching test in long sitting) were measured before and after exercise. The data was analyzed with paired t-test to determine significant differences of all suggested factors between pre and post-exercise by make use of the SPSS(ver 10.0) package program. Results: The strength of the both knee flexors and extensors were increased significantly(right knee; p<0.01, left knee; p<0.05). Anteroposterior sway area (p<0.01), and sway path (p<0.001) of both leg were reduced significantly with eyes closed and opened. Whole body reaction time by optical stimulation was increased significantly (p<0.01) but whole body reaction time by auditory stimulation was no significant difference. The flexibility was increased significantly (p<0.01). Conclusion: Aquatic health exercise program can improve muscle strength, balance, whole body reaction, and flexibility.

  • PDF

Effects of Full Body Massage on Labor Pain and Delivery Stress Reaction for Primipara during Labor (분만 중 전신마사지가 초산부의 분만진통과 분만스트레스 반응에 미치는 효과)

  • Lee, Kun-Ja;Chang, Chun-Ja;Jo, Hyun-Sook
    • Women's Health Nursing
    • /
    • v.9 no.3
    • /
    • pp.224-234
    • /
    • 2003
  • Purpose: This study was to test the effects of a full body massage on labor pain and delivery stress reaction for primipara during labor. Method: This study employed a quasi- experimental method(nonequivalent control group, pre-post test design). The subjects of this study were 57 primipara hospitalized at the U OB & GYN hospital in Inchon from November 1. 2001 to July 31, 2002. 28 women were assigned to the experimental group and 29 to the control group. The experimental group was given 20 minutes full body massage for each of three delivery phases. The control group was given conventional delivery care. The levels of labor pain were measured by the Visual Analogue Scale and the expression scores of the labor pain and the levels of delivery stress reaction were measured by pulse rate, respiration rate, and blood pressure, and State-Anxiety Scale. Data were analyzed using the repeated measures analysis of covariance(ANCOVA), t-test, $X^2$- test, simple ANCOVA with SPSS program. Result: There was no interaction effect between time and group(F=.370, p=.693), but significant time effects were found for subjective labor pain(F=3.840, p=.028). There was no interaction effect between time and group(F=.112, p=.894), but significant group effects were found for objective labor pain(F=12.299, p=.001). There was no interaction effect between time and group for PR(F=.172, p=.843), RR(F=.626, p=.539), SBP(F=.089, p=.915), DBP(F=.748, p=.479), but significant group effects were found for SBP(F=7.547, p=.008). The level of status anxiety of the experimental group was significantly lower than the control group(F=11.787, p=.001). Conclusion: This study showed that the full body massage has partially positive effect on labor pain and delivery stress reaction. Therefore this study suggested that the full body massage might be used clinically to help primipara during labor.

  • PDF

The study of batting characteristics in elite baseball players (엘리트 야구 선수의 타격 특성 연구)

  • Lee, Young-Suk
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.173-184
    • /
    • 2003
  • The purpose of this study was to investigate the batting characteristics in elite baseball players. Seven skilled collegiate players hit the ball which was thrown by a pitching machine linearly and strongly to the center of the field. Time, velocity, angle and pound reaction force variables were measured by using high-speed video cameras and pound reaction force analyzer. The results were as follows: 1. The elite players finished their stride performance in a short time and they stayed longer in a swing phase. The increases in the range of trunk rotation were associated with the delay of the swing phase. 2. The 'take-back' phenomenon in the trunk was showed after the stride phase. 3. The down swing demonstrated powerful line drives. 4. Equivalent body weights were placed on both feet during the ready phase. 95% of the body weights were moved to the rear foot during the stride phase, whereas the body weights were driven to the front foot during the swing phase. 95% of the body weights were placed on the front foot at impact.

Study on The Attitude Stabilization Techniques of Leo Satellites

  • Hwan, Lho-Young;Yong, Jung-Kang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.56.5-56
    • /
    • 2001
  • In the three axis control of satellite by using reaction wheel and gyro, a reaction wheel produces the control torque by the wheel speed or momentum, and a gyro carries out measuring of the attitude angle and the attitude angular velocity In this study, dynamic modelling of the Low Earth Orbit (LEO) is consisted of the one from the rotational motion of the satellite with the basic rigid body and a flexible body model, and the gyro in addition to the reaction wheel model. The results obtained by the robust controller are compared with those of the PI (Proportional and Integration) controller which is commonly used for the stabilizing satellite.

  • PDF

Histopathological Changes of Subcutaneous Exposure to Glass Fibers in Rats (흰쥐에서 유리섬유의 피하삽입에 의한 경시적 병리조직학적 변화)

  • Lee, Min-Jae;Cho, Soo-Hun;Jang, Ja-June
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.69-76
    • /
    • 1997
  • To exanime in vivo tissue reactions of glass fibers, we injected glass fibers to rats subcutaneously. We made fibers of average dimensions of approximately $2{\mu}m$ in diameter and $60{\mu}m$ in length. After instilation of glass fiber we sacrificed rats sequentially at 1, 3 and 6 months. At 1 month after injection of glass fibers, the exposure area turned to yellow color and formed well-demarcated round mass. The average size of the mass was $1\times0.3cm$. Grossly detectable mass was decreased in size at 6 months compared to 1 or 3 months. Microscopically, strong foreign body reaction to glass fibers, inflammation and fibrosis were observed until 6 months. Foreign body reaction was increased up to 3 months, but it was decreased after 6 months. In scanning electron microscope, there was many bundles of glass fibers around the inflammation area, but the size of glass fibers were gradually reduced from 1 month to 6 months. These results suggest that subcutaneous exposure of glass fiber can provoke strong tissue reaction including foreign body granulomas, inflammation and fibrosis. But glass fiber itself did not produce any neoplastic changes.

  • PDF

esearch on Biomechanics of Korean Body Segments (한국인 인체분적의 동특성에 관한 연구)

  • 박수찬;박세진;황민철
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.291-300
    • /
    • 1996
  • This study is to determine the biomechanical characteristics of Korean. Male 58 and Female 54 were participated for the measurement which was performed by immersion method and reaction board method. Body parts were head with neck, trunk, upper arm, forearm, hand, thigh, leg, and foot. Their volumes were measures by immersion method. Their weight were determined by using Dempster(1995), Drills and Contini(1969) density data. Each center of body part weight were determined by specific posture on the reaction board. The postures were asked to the subject forearm- lifted posture, total let- lifted posture, foot-lifted posture. According to each posture, the center of each part were calculated.

  • PDF

Reaction time and EMG pattern analysis of Body guards who have trained martial arts to accidental situations (경호무도를 수련한 경호원의 우발 상황 시 경호자세의 반응시간 및 EMG 패턴 분석)

  • Jung, Sung-Sook
    • Korean Security Journal
    • /
    • no.19
    • /
    • pp.207-223
    • /
    • 2009
  • The main purpose of this study was to analyze the reaction time of body guards in different stances to provide quantification of data for educational use. There were 4 martial art trained body guards participating in this study. The results of the EMG analysis and reaction time are as follows. The average reaction time of the whole body was $1.38{\pm}0.07$ seconds. In the first phase the reaction to the signal was $0.22{\pm}0.02$ seconds while in the second phase the reaction after checking was $0.62{\pm}0.10$ seconds, which produced the largest impulse. the reaction times of the third and fourth phase were gradually reduced, $0.29{\pm}0.02$ seconds and $0.26{\pm}0.02$ seconds consecutively. In the body guard posture the following muscles had a high activity level; phase one the right and left of the tibialis anterior muscle, phase two the right and left of the tibialis anterior muscle and the right of the gastrocnemius, phase three the right side of the tibialis anterior and gastrocnemius, phase four the left and right of the biceps femoris and the right side of the rectus femoris. In the first and second phase the shank muscles were used a lot, whereas in the third and fourth phase the shank and thigh muscles were used a lot showing the overall muscle activation of the lower limbs.

  • PDF

Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

  • Jeon, Hong Bae;Kang, Dong Hee;Gu, Ja Hea;Oh, Sang Ah
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.40-45
    • /
    • 2016
  • Background Bioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws. Methods A total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland) plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA) in 61 patients. Their mean age was 35.2 years (range, 15-84 years). Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla. Results Complications occurred in eight (3.4%) of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction. Conclusions Inadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.