• 제목/요약/키워드: Body phantom

검색결과 344건 처리시간 0.024초

An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom

  • Pak, Minjung;Yoo, Jaeryong;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.274-281
    • /
    • 2016
  • Background: Whole-body counters are widely used to evaluate internal contamination of the internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic requirement that quality control procedures be applied to verify the reliability of the measured results. The implementation of intercomparison programs plays an important role in quality control, and the accuracy of the calibration and the reliability of the results should be verified through intercomparison. In this study, we evaluated the reliability of 2 whole-body counting systems using 2 calibration methods. Materials and Methods: In this study, 2 whole-body counters were calibrated using a reference male bottle manikin absorption (BOMAB) phantom and a Radiation Management Corporation (RMC-II) phantom. The reliability of the whole-body counting systems was evaluated by performing an intercomparison with International Atomic Energy Agencyto assess counting efficiency according to the type of the phantom. Results and Discussion: In the analysis of counting efficiency using the BOMAB phantom, the performance criteria of the counters were satisfied. The relative bias of activity for all radionuclides was -0.16 to 0.01 in the Fastscan and -0.01 to 0.03 in the Accuscan. However, when counting efficiency was analyzed using the RMC- II phantom, the relative bias of $^{241}Am$ activity was -0.49 in the Fastscan and 0.55 in the Accuscan, indicating that its performance criteria was not satisfactory. Conclusion: The intercomparison process demonstrated the reliability of whole-body counting systems calibrated with a BOMAB phantom. However, when the RMC-II phantom was used, the accuracy of measurements decreased for low-energy nuclides. Therefore, it appears that the RMC-II phantom should only be used for efficiency calibration for high-energy nuclides. Moreover, a novel phantom capable of matching the efficiency of the BOMAB phantom in low-energy nuclides should be developed.

컴퓨터 단층촬영시 환자피폭선량에 관한 연구 (A Study on the exposure dose for the computed tomography)

  • 김문찬;임종석;박형로;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권2호
    • /
    • pp.21-27
    • /
    • 2004
  • 본 연구에서는 현재 국내에서 사용되고 있는 여러 기종의 CT장치를 대상으로 하여 CT검사로 인한 방사선피폭 정도를 실험을 통하여 알아보고, 외국의 사례와 비교함으로써 CT장치의 성능관리의 하나인 피폭선량 기준 설정에 필요한 기초 데이터를 제시하고자 서울시 및 경기도에 위치한 병의원 및 종합병원에서 가동 중인 32대의 CT장치를 대상으로 CTDI값을 측정한 결과 다음과 같았다. 1) Head phantom의 100 mAs 당 $CTDI_W$값은 $8.1{\sim}19.1\;mGy$ 범위였고, 평균 $13.5{\pm}3.2\;mGy$였다. 그리고 body phantom의 $CTDI_W$값은 $3.7{\sim}10.9\;mGy$ 범위였고, 평균 $7.1{\pm}2.0\;mGy$였다. 2) Single detector CT와 multi detector CT의 $CTDI_W$값을 비교해 보면, multi detector CT가 single detector CT에 비해 head phantom에서는 평균 3.2 mGy(약 1.26배), body phantom에서는 평균 2.1 mGy(약 1.34배) 높았다. 3) Channel 수에 따른 $CTDI_W$값 비교에서는 head pahantom에서는 4 channel CT가 가장 높았으며, 8 channel CT, 16 channel CT, single detector CT순이었으며, body phantom에서는 역시 4 channel CT와 8 channel CT, 16 channel CT, single detector CT순이었다.

  • PDF

전신방사선조사 시 선속 스포일러에 따른 선량 분포 및 영향 평가 (Beam Spoiler-dependent Total Body Irradiation Dose Assessment)

  • 이동연;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.141-148
    • /
    • 2018
  • This study examined the properties of photons and the dose distribution in a human body via a simulation where the total body irradiation(TBI) is performed on a pediatric anthropomorphic phantom and a child size water phantom. Based on this, we tried to find the optimal photon beam energy and material for beam spoiler. In this study, MCNPX (Ver. 2.5.0), a simulation program based on the Monte Carlo method, was used for the photon beam analysis and TBI simulation. Several different beam spoiler materials (plexiglass, copper, lead, aluminium) were used, and three different electron beam energies were used in the simulated accelerator to produce photon beams (6, 10, and 15 MeV). Moreover, both a water phantom for calculating the depth-dependent dosage and a pediatric anthropomorphic phantom for calculating the organ dosage were used. The homogeneity of photon beam was examined in different depths for the water phantom, which shows the 20%-40% difference for each material. Next, the org an doses on pediatric anthropomorphic phantom were examined, and the results showed that the average dose for each part of the body was skin 17.7 Gy, sexual gland 15.2 Gy, digestion 13.8 Gy, liver 11.8 Gy, kidney 9.2 Gy, lungs 6.2 Gy, and brain 4.6 Gy. Moreover, as for the organ doses according to materials, the highest dose was observed in lead while the lowest was observed in plexiglass. Plexiglass in current use is considered the most suitable material, and a 6 or 10 MV photon energy plan tailored to the patient condition is considered more suitable than a higher energy plan.

Characteristics of Magnetic Resonance-Based Attenuation Correction Map on Phantom Study in Positron Emission Tomography/Magnetic Resonance Imaging System

  • Hong, Cheolpyo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.189-193
    • /
    • 2020
  • An MR-based attenuation correction (MRAC) map plays an important role in quantitative positron emission tomography (PET) image evaluation in PET/magnetic resonance imaging (MRI) systems. However, the MRAC map is affected by the magnetic field inhomogeneity of MRIs. This study aims to evaluate the characteristics of MRAC maps of physical phantoms on PET/MRI images. Phantom measurements were performed using the Siemens Biograph mMR. The modular type physical phantoms that provide assembly versatility for phantom construction were scanned in a four-channel Body Matrix coil. The MRAC map was generated using the two-point Dixon-based segmentation method for whole-body imaging. The modular phantoms were scanned in compact and non-compact assembly configurations. In addition, the phantoms were scanned repeatedly to generate MRAC maps. The acquired MRAC maps show differently assigned values for void areas. An incorrect assignment of a void area was shown on a locally compact space between phantoms. The assigned MRAC values were distorted using a wide field-of-view (FOV). The MRAC values also differed after repeated scans. However, the erroneous MRAC values appeared outside of phantom, except for a large FOV. The MRAC map of the phantom was affected by phantom configuration and the number of scans. A quantitative study using a phantom in a PET/MRI system should be performed after evaluation of the MRAC map characteristics.

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • 제8권2호
    • /
    • pp.52-59
    • /
    • 2012
  • This study uses digital imaging and communications in medicine (DICOM) files acquired after CT scan to obtain the absorbed dose distribution inside the body by using the patient's actual anatomical data; uses geometry and tracking (Geant)4 as a way to obtain the accurate absorbed dose distribution inside the body. This method is easier to establish the radioprotection plan through estimating the absorbed dose distribution inside the body compared to the evaluation of absorbed dose using thermo-luminescence dosimeter (TLD) with inferior reliability and accuracy because many variables act on result values with respect to the evaluation of the patient's absorbed dose distribution in diagnostic imaging and the evaluation of absorbed dose using phantom; can contribute to improving reliability accuracy and reproducibility; it makes significance in that it can implement the actual patient's absorbed dose distribution, not just mere estimation using mathematical phantom or humanoid phantom. When comparing the absorbed dose in polymethly methacrylate (PMMA) phantom measured in metal oxide semiconductor field effect transistor (MOSFET) dosimeter for verification of Geant4 and the result of Geant4 simulation, there was $0.46{\pm}4.69%$ ($15{\times}15cm^2$), and $-0.75{\pm}5.19%$ ($20{\times}20cm^2$) difference according to the depth. This study, through the simulation by means of Geant4, suggests a new way to calculate the actual dose of radiation exposure of patients through DICOM interface.

재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가 (Comparison of PET/MR image quality with and without point spread function algorithm according to reconstruction type)

  • 박찬록;문일상;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.43-45
    • /
    • 2018
  • NEMA IEC body phantom으로 PET/MR 스캐너를 이용해 MR 영상 기반의 감쇠보정 된 PET 영상을 얻고, 반복재구성 기반의 점 확산 함수(PSF)에 적용 유무에 따라 PET 영상을 Contrast recovery 와 SNR 의 평가 인자를 적용해 평가하였다. 또한, 동일한 재구성 방법에 따라 본원의 내원한 환자의 영상도 평가하였다. 데이터는 임상환자 와 팬텀 실험 모두 PSF를 적용해 재구성한 영상이 모두 영상의 질이 향상됨을 확인하였다. MR 기반으로 얻어진 PET 영상 평가가 추후에도 계속해서 필요하다고 사료된다.

전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질 (Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations)

  • 조평곤;김유현;최종학;이기열;김형철;김장섭;신동철;이성현;이준협;신귀순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.453-460
    • /
    • 2009
  • 슬라이스 두께(slice thickness)와 선속시준(beam collimation, BC)의 변화에 따른 CT gantry aperture 내의 선량 분포와 영상의 질을 알아보고자 하였다. CT장치로는 64-slice MDCT 스캐너(Brilliance 64, Philips, Cleveland, USA)를 사용하였다. 피사체가 없는 경우(air scan)의 선량측정을 위해 CT용 전리함을 gantry aperture내의 회전중심점(isocenter)과 12시, 3시, 6시, 9시 방향에서 회전중심점으로부터 5 cm 간격으로 30 cm까지 BC를 변화시키면서 각각 측정 하였다. 또한 5개의 구멍(팬텀의 중심과 12시, 3시, 6시, 9시 방향)으로 구성된 CT head and body dose phantom을 gantry aperture 내에 위치시키고 각 지점에서 선량을 측정하였다. Gantry aperture 내 피사체의 위치변화에 대한 영상의 노이즈를 비교하기 위해서 AAPM CT용 팬텀의 물통을 회전중심점과 12시 방향으로 5 cm와 10 cm 이동시킨 후 BC를 변화시키면서 스캔한 후 팬텀의 중심과 12시, 3시, 6시, 9시 방향의 지점에서 노이즈를 측정하였다. 이 중에서 몇 군데의 위치는 영상 영역에서 벗어나서 측정 할 수가 없었다. 이때 노이즈 측정을 위해서 영상재구성의 슬라이스 두께는 5 mm로 하였다. 측정한 결과 다음과 같은 결론을 얻었다: 첫째, CTDIw는 회전중심점으로부터 멀어질수록, BC가 넓어질수록 감소하였다. 둘째, BC의 넓이가 비슷한 경우의 CTDIw는 거의 유사한 값을 보였다. 즉, CTDIw는 검출기 배열의 수나 화소의 크기 보다는 전체적인 BC의 넓이에 의존하고 있음을 알 수 있었다. 셋째, air scan과 phantom scan 경우 모두에서 CTDIw는 BC가 증가될수록 감소하였다. 그러나 air scan의 경우보다 head phantom scan 시 약 30%, body phantom scan 시 약 52% 정도 CTDIw의 값이 감소하였다. 넷째, BC와 팬텀의 위치 변화에 따른 노이즈 값은 $2{\times}0.5\;mm$의 BC을 제외하고는 head phantom scan한 경우 3.9~5.9, body phantom scan한 경우 5.3~7.4로 나타나, BC와 팬텀의 위치변화에 따라서 큰 차이가 없었다. 따라서 피사체의 위치가 gantry aperture 내 SFOV(scan field of view)에 포함될 경우 회전중심점에 정확하게 위치시키지 않아도 영상의 질에는 많은 영향을 미치지 않는다는 것을 알 수 있었다.

  • PDF

보급형 3D 프린터를 이용한 인체 모형 뼈 팬텀 제작의 기초연구: Femur 대상으로 적층형 출력 방식 이용 (A Fundamental Study on the Fabrication of Human Model Bone Phantom using an Entry-Level 3D Printer: using FDM Method for the Femur Model)

  • 남궁은재;김도희;김소희;박세은;정다빈;박상협;허영철
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.651-660
    • /
    • 2020
  • 본 연구에서는 보급형 3D 프린터를 이용하여 인체 Femur와 유사한 HU 값을 가진 팬텀을 제작하여 기존 돼지 뼈를 대체할 수 있는지 분석하고자 하였다. 인체 Femur의 HU 값을 알아보기 위해 연령별 총 372명의 데이터를 분석하였다. 보급형 3D 프린터를 이용하여 PLA-Cu 20%를 이용하여 인체 뼈 모형 팬텀을 제작하여 CT 검사하였다. 돼지 뼈는 생후 6개월 된 돼지로 도축된 지 2일이 지난 뼈를 이용하였다. 검사결과 내부채움 80%로 제작한 3D 프린팅 팬텀이 인체의 모든 데이터와 유사한 값이 나타났고(p<0.05) 돼지뼈와는 차이가 있었다(p>0.05). 또한 연령대별 Femur의 HU 값의 경우 연령대가 증가할수록 HU의 값은 줄어드는 것으로 확인 되었다(p<0.05). 3D 프린팅과 HU 값은 적층 높이에 대해서는 약한 음의 상관성을 확인 하였지만 내부 채움에서는 182.13±1.290으로 강한 양의 상관성(R2=0.996)을 확인하였다(p<0.05). 결론적으로 3D 프린팅을 이용한 인체 모형 팬텀이 기존 돼지뼈 팬텀에 비해 인체와 유사한 정도의 HU 값을 나타낼 수 있음을 확인할 수 있었으며 이에 본 연구가 3D 프린터를 이용한 인체 모형 팬텀의 제작에 기초자료를 제공할 수 있을 것이라 사료된다.

Mirror Therapy for Phantom Limb Pain

  • Kim, Sae-Young;Kim, Yun-Young
    • The Korean Journal of Pain
    • /
    • 제25권4호
    • /
    • pp.272-274
    • /
    • 2012
  • Phantom limb pain is a painful sensation that is perceived in a body part that no longer exists. To control this pain, many methods have been used such as medication, physical treatment, nerve block, neuromodulation, surgical treatment and mirror therapy. However, until now, there effects have been uncertain. We report the successful reduction of phantom limb pain using mirror therapy when other treatments initially failed to control the pain.

Phantom을 이용한 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가 (Accuracy Evaluation of CyberKnife $Synchrony^{TM}$ Respiratory Tracking System Using Phantom)

  • 김가중;배석환;임창선;김종일
    • Journal of Radiation Protection and Research
    • /
    • 제34권3호
    • /
    • pp.137-143
    • /
    • 2009
  • 본 연구는 호흡에 따라 움직임이 큰 흉부나 복부 장기의 방사선 수술에 적용되는 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성을 평가하였다. $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가를 위해 금침이 삽입된 움직임 Phantom을 이용하였고, Phantom은 아크릴 볼이 들어 있는 정육면체에 Radiochromic 필름을 삽입하여 가상의 치료용적인 아크릴 볼에 21 Gy, 70% 등선량곡선으로 처방하였다. 고정된 Phantom의 금침추적방법과 움직임 Phantom의 $Synchrony^{TM}$ 호흡추적 방법으로 나누어 각각 5회 측정한 정확성 평가는 고정된 Phantom 추적 시 총 에러는 $0.0195{\sim}0.652mm$, 총 에러 평균은 0.3926 mm로 나타났으며, 움직임 Phantom을 이용한 $Synchrony^{TM}$ 호흡 추적 방법의 결과로 총 에러는 $0.4405{\sim}0.7665mm$, 총 에러 평균은 0.5673 mm로 나타나 두 방법에 유의한 차이가 없었다. 본 연구를 통해 사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치의 정확성을 평가하였으며 체부의 방사선 수술 적용 시 그 유용성을 확인할수 있었다.