DOI QR코드

DOI QR Code

전신방사선조사 시 선속 스포일러에 따른 선량 분포 및 영향 평가

Beam Spoiler-dependent Total Body Irradiation Dose Assessment

  • 이동연 (동남권원자력의학원 방사선종양학과) ;
  • 김정훈 (부산가톨릭대학교 방사선학과)
  • Lee, Dong-Yeon (Department of Radiation Oncology, Dongnam Institute of Radiological & Medical Science) ;
  • Kim, Jung-Hoon (Department of Radiology, Catholic University of Pusan)
  • 투고 : 2018.02.27
  • 심사 : 2018.04.21
  • 발행 : 2018.04.30

초록

This study examined the properties of photons and the dose distribution in a human body via a simulation where the total body irradiation(TBI) is performed on a pediatric anthropomorphic phantom and a child size water phantom. Based on this, we tried to find the optimal photon beam energy and material for beam spoiler. In this study, MCNPX (Ver. 2.5.0), a simulation program based on the Monte Carlo method, was used for the photon beam analysis and TBI simulation. Several different beam spoiler materials (plexiglass, copper, lead, aluminium) were used, and three different electron beam energies were used in the simulated accelerator to produce photon beams (6, 10, and 15 MeV). Moreover, both a water phantom for calculating the depth-dependent dosage and a pediatric anthropomorphic phantom for calculating the organ dosage were used. The homogeneity of photon beam was examined in different depths for the water phantom, which shows the 20%-40% difference for each material. Next, the org an doses on pediatric anthropomorphic phantom were examined, and the results showed that the average dose for each part of the body was skin 17.7 Gy, sexual gland 15.2 Gy, digestion 13.8 Gy, liver 11.8 Gy, kidney 9.2 Gy, lungs 6.2 Gy, and brain 4.6 Gy. Moreover, as for the organ doses according to materials, the highest dose was observed in lead while the lowest was observed in plexiglass. Plexiglass in current use is considered the most suitable material, and a 6 or 10 MV photon energy plan tailored to the patient condition is considered more suitable than a higher energy plan.

키워드

참고문헌

  1. Kim SH. Identification of symptoms by treatment phases in children with leukemia. [Master's thesis]. Seoul: Graduate School of Nursing Yonsei University;2009.
  2. Park YK. The impacts of the in-patient' copayment waiver policy on medical services and outcomes for leukemia children. [Master's thesis], Seoul: Graduate School of Public Health Yonsei University; 2008.
  3. Kim SR, Kim HJ, Kim SH. Clinical utility of fluorescence in-situ hybridization profile test in detecting genetic aberrations in acute leukemia. Korean J Lab Med. 2009;29:371-378. https://doi.org/10.3343/kjlm.2009.29.5.371
  4. Beaumais TA, Fakhoury M, Medard Y, Azougagh S, Zhang D, Yakouben K, et al. Determinants of mercaptopurine toxicity in paediatric acute lymphoblastic leukemia maintenance therapy. British Journal of clinical Pharmacology. 2010;71(4): 575-584. https://doi.org/10.1111/j.1365-2125.2010.03867.x
  5. Van Dyk J, Galvin JM, Glasgow GP, Podgorsak EB.. AAPM REPORT NO. 17: The Physical Aspects of Total and Half Body Photon Irradiation. New York:Radiation Therapy Committee American Association of Physics in Medicine; 1986.
  6. Thomas ED, Buckner CD, Banaji M, Clift RA, Fefer A, Flournoy N, et al. One hundred patients with acute leukemia treated by chemotherapy, total body irradiation, and allogeneic marrow transplantation. Blood J. 1977;49(4):511-533.
  7. Kim SJ, Han DK, Baek HJ, Kim DY, Nam TK, Hwang TJ, et al. Comparison of total body irradiation-based or non-total body irradiation-based conditioning regimens for allogeneic stem cell transplantation in pediatric leukemia patients. Korean J Pediat. 2010;53(4):538-547. https://doi.org/10.3345/kjp.2010.53.4.538
  8. Perez CA, Brady LW, Halperin EC, Wazer DE. Principles and Practice of Radiation Oncology. 4th ed. New York: Lippincott Williams & Wilkins; 2004.
  9. Aristei C, Tabilio A. Total-body irradiation in the conditioning regimens for autologous stem cell transplantation in lymphoproliferative diseases. The oncologist. 1999;4:386-397.
  10. Denis B. Pelowits. MCNPXTM User's manual version2.5.0 .LosAlamos National Laboratory, 2005.
  11. Lin JP, Liu WC, Lin CC. Investigation of photoneutron dose equivalent from high-energy photons in radiotherapy. Applied Radiation and Isotopes. 2007;65:599-604. https://doi.org/10.1016/j.apradiso.2007.01.017
  12. Huang WL, Li QF, Lin TZ. Calculation of photoneutrons produced in the targets of electron linear accelerators for radiography and radiotherapy applications. Nucl Instr and Meth in Phy Res. 2005;B229:339-347.
  13. Han EY, Bolch WE, Eckerman KF. Revision to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema. Health Phys. 2006;90:337-356. https://doi.org/10.1097/01.HP.0000192318.13190.c4
  14. Valentin J. ICRP 89: Basic Anatomical and Physiological Data for Use in Radiological Protection Reference Values. Internatioal Commission on Radiological Protection; 2002.
  15. White DR, Griffith RV, Wilson IJ. ICRU Report 46:Photon, electron, proton and neutron interaction data for body tissues. Internatioal Commission on Radiation Units and Measurements; 1992.
  16. Choi JH, Kim JS, Choi JM Shin EH, Song KW, Park YH. Analysis of surface dose refer to distance between beam spoiler and patient in total body irradiation. J Korea Soc Ther Radiol. 2007;19(1):51-54.
  17. Lee MY. The effect of x-ray filter materials in the skin dose & tube loading at x-ray examinations. [Master's thesis]. Seoul: Dept. of Health Science Graduate School Korea University; 2005.
  18. Ravichandran R, Binukumar JP, Davis CA, Sivakumar SS, Krishnamurthy K, Mandhari ZA, et al. Beam configuration and physical parameters of clinical high energy photon beam for total body irradiation (TBI). Phys Med. 2011;27:163-168. https://doi.org/10.1016/j.ejmp.2010.10.003
  19. Mesbahi A, Fix M, Allahverdi M, Grein E, Garaati H. Monte Carlo calculation of Varian 2300C/D Linac photon beam characteristics: a comparison between MCNP4C, GEANT3 and measurements. Appl Radiat Isotopes 2005;62(3):469-477. https://doi.org/10.1016/j.apradiso.2004.07.008
  20. Baumgartner A, Steurer A, Maringer F. Simulation of photon energy spectra from Varian 2100C and 2300C/D Linacs: Simplified estimates with PENELOPE Monte Carlo models. Appl Radiat Isotopes. 2009;67(11):2007-2012. https://doi.org/10.1016/j.apradiso.2009.07.010
  21. Clare Mckay, Kellie A, Caroline Wright. Beyond cancer treatment - a review of total lymphoid irradiation for heart and lung transplant recipients. Journal of medical radiation science. 2014;61:202-209. https://doi.org/10.1002/jmrs.63