• 제목/요약/키워드: Body Temperatures

검색결과 506건 처리시간 0.029초

신생아의 직장체온과 고막 및 액와체온과의 비교 (Comparison of Rectal Temperature with Axillary and Tympanic Temperature)

  • 황진순;송경애
    • 기본간호학회지
    • /
    • 제4권2호
    • /
    • pp.351-358
    • /
    • 1997
  • Body temperature should be measured accurately to assess neonate's condition for proper care. Temperatures measured in rectal, axillary and tympanic site were compared in 129 normal neonates to find out proper nursing time for measuring temperature and the validity of fever detection. The results were as follows : 1. Mean temperatures of axillary and tympanic site($36.85^{\circ}C,\;37.12^{\circ}C$) were significantly lower than those of rectal site($37.19^{\circ}C$). 2. Mean nursing time for measuring body temperature was significantly higher and lower in axillary and tympanic temperatures(159.49 seconds, 11.07 seconds) than in rectal temperature(105.62 seconds). 3. Tympanic and axillary temperatures were significantly correlated with rectal temperature (r=0.85, r=0.78) and the significant correlation was demonstrated between tympanic and axillary temperatures(r=0.76). 4. Sensitivity, specificity, positive and negative predictive values were 0.87, 0.90, 0.72, 0.96 for detecting fever respectively. The above findings indicated that the tympanic thermometer offers a useful alternative to conventional methods.

  • PDF

소의 일중 체온변화 Data Base 구축에 관한 연구 (Establishment of Data Base for Body Temperature Change in Cattle)

  • 정왕용;이원현;이상철;이상락
    • 한국축산시설환경학회지
    • /
    • 제18권2호
    • /
    • pp.95-98
    • /
    • 2012
  • 센서 네트워크 및 무선 주파수 식별 기술을 이용하여 가축의 건강상태를 자동으로 모니터링 하기위한 기술에 활용하기 위하여 정상시 소의 체온 data base를 구축하였다. 체온측정을 위해 거세한 홀스타인 수소 3두를 공시하였다. 동물들은 stanchion barn에서 2주간 적응시킨 후 열전대와 recorder 장치를 이용하여 귀, 목, 머리와 심부 4부위의 온도를 9일간 연속 측정하였다. 측정한 체온의 모든 부위는 하루 중 낮 시간에는 체온이 올라가고 다시 저녁시간에는 체온이 떨어지는 패턴을 보였다. 하루중 심부체온은 $36.1^{\circ}C$에서 $38.2^{\circ}C$의 범위에서 변화하였다. 각 피부 온도는 환경온도 변화에 따라 차이를 보였다. 귀, 목, 머리 온도의 하루중 변화는 각각 $28.5{\sim}36.3^{\circ}C$, $28.0{\sim}36.1^{\circ}C$, $28.2{\sim}35.0^{\circ}C$를 나타내었다.

신체의 부위별 피복이 체온조절 및 주관적인 감각에 미치는 영향(II) (Effects of Covering Parts of Body with Garments on Human Thermoregulation and Sensation(II))

  • 이종민
    • 한국의류학회지
    • /
    • 제18권3호
    • /
    • pp.339-347
    • /
    • 1994
  • In this study the physiological significance of the upper and lower body on thermoregulation and sensation are examined. Experiments were carried out on 4 females in a climatic chamber conditioned at $25\pm1^{circ}C, 50\pm5%$ R.H.. Before the measurements, subjects were exposed to 3 types of enviromental temperature: 1) $25\pm1^{\circ}C$ for 60 min.(ST), 2) $25^{\circ}C$\rightarrow35^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(HT), 3) $25^{\circ}C$\rightarrow15^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(LT) covering the upper body (U) or lower body (L) with garments. 1) $T_{re}$ was significantly higher in L than in U only in 57 condition. $T_{sk}$ and Temp. under the clothing were higher in U than in L in all three conditions. Thermal sensation was warmer in U than in L, and comport sensation was most comfortable in HT condition. 2) When the upper or lower body was covered or exposed, the mean skin temperature of the upper body was higher than that of the lower body. Following covering and uncovering the same area, the changes in skin temperature were greater in the upper body than in lower body, and covering the upper body produced a greater difference of skin temperature between body and lower body than covering the lower body. 3) In all environmental conditions, when the upper body was uncovered, the skin temperatures of the chest, upper arms and forearms dropped to a considerable degree, and when the lower body was uncovered, skin temperatures of the legs showed the same pattern. On the other hand, skin temperature of the thinghs showed only little change in all cases except forehead and back uncovered or covered in two clothing types.

  • PDF

Axillary temperature measurements based on smart wearable thermometers in South Korean children: comparison with tympanic temperature measurements

  • Choi, Younglee;Ahn, Hye Young
    • Child Health Nursing Research
    • /
    • 제28권1호
    • /
    • pp.62-69
    • /
    • 2022
  • Purpose: This study explored the validity of a new type of thermometer and parent satisfaction with the new device. This 24-hour continuous monitoring smart wearable wireless thermometer (TempTraq®) uses a very small semiconductor sensor with a thin patch-like shape. Methods: We obtained 397 sets of TempTraq® axillary temperatures and tympanic temperatures from 44 pediatric patients. Agreement between the axillary and tympanic measurements, as well as the validity of the TempTraq® axillary temperatures, were evaluated. Satisfaction surveys were completed by 41 caregivers after the measurements. Results: The TempTraq® axillary temperatures demonstrated a strong positive correlation with the tympanic temperatures. The Bland-Altman plot and analysis of TempTraq® axillary temperatures and tympanic temperatures showed that the mean difference was +0.45 ℃, the 95% limits of agreement were -0.57 to +1.46 ℃. Based on a tympanic temperature of 38 ℃, the results of validity of fever detection were sensitivity 0.85 and specificity 0.86. Satisfaction scores for TempTraq® temperature measurement were all > 4 points (satisfactory). Conclusion: TempTraq® smart axillary temperature measurement is an appropriate method for measuring children's temperatures since it was highly correlated to tympanic temperatures, had a reliable level of sensitivity and specificity, and could be used safely and conveniently.

Observations on Normal Body Temperatures in Differently Climate Conditions

  • Nguyen, My-Hang;Hiromi Tokura
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.406-408
    • /
    • 2002
  • In order to know the characteristics of circadian rhythms in core temperature in tropical inhabitants, we measured rectal temperatures every 10 min for 24 hrs in 6 Vietnamese, 20 - 22 yrs (5 males and I females) under natural conditions. Average light intensity was 16000 lx. Ambient temperatures ranged from 33 to 36 oC. These data obtained were compared with those in Japanese setters and the Polish inhabitants. The participants were sitting mostly during wakefulness and lying in bed during sleep. The results obtained are summarized as follows: I) The average maximum value was 37.7 oC, which was significantly higher than in the Japanese and Polish as well. 2) The average minimum value was 36.4 oC, which was also lower. 3) A range of oscillation was 1.3 oC, which was clearly greater than in the people living in the temperate areas. The higher maximum value of core temperature, which was actively regulated under warm temperature, seemed of adaptive significance in order to reduce water consumption. A greater rage of oscillation in tropical Vietnamese people might have ecological significance for efficient acclimatization in the environment with strong light intensity and high ambient temperature, suggesting that the setpoint of core temperature could show a greater range of oscillation.

  • PDF

저순도 알루미나 예비소결체 선삭시의 공구 마멸 (Tool Wear in Turning of the Presintered Low Purity Alumina)

  • 이재우
    • 한국정밀공학회지
    • /
    • 제22권1호
    • /
    • pp.39-46
    • /
    • 2005
  • In this study, unsintered, presintered and full-sintered low purity alumina ceramics were machined with various tools to clarify the machinability and the optimum cutting conditions. The main conclusions obtained were as follows. (1) Machined with alloy steel tool, the machinability of the presintered ceramics becomes better with the decrease of presintering temperature, but that of unsintered ceramics(white body) was extremely poor. (2) In the case of carbide, K01, the tool life in machining the white body was the longest, and the machinability of presintered ceramics becomes poorer with the increase of the presintering temperature. (3) The K01 tools exhibit longer life than the P10 tools in machining both the white body and the ceramics presintered at $1450^\circC$ or higher temperatures, but the P10 tools shows longer tool life than the K10 tools in machining of the ceramics presintered at temperatures below $1450^\circC$.

전정맥 전신마취하(下) 복강경 수술환자의 부위별 심부체온의 변화 평가 (Core Temperature Evaluation in Different Body Parts in Patients Undergoing Laparoscope Surgery under Total Intravenous Anesthesia)

  • 함태수;김원호;김남초;유제복
    • 기본간호학회지
    • /
    • 제22권4호
    • /
    • pp.379-386
    • /
    • 2015
  • Purpose: The trend of body temperature change during laparoscopic surgery and the most adequate site for monitoring temperature measurements have not been investigated thoroughly. In this study body temperature change during laparoscopic surgery was measured and measurements of the tympanic, esophageal, and nasopharyngeal core temperatures in surgical patients with total intravenous anesthesia were compared. Methods: From February to October 2013, 28 laparoscopic surgical patients were recruited from a tertiary hospital in Seoul. The patients' core temperature was measured 12 times at ten minute intervals from ten minutes after the beginning of endotracheal intubation. Results: Repeated measure of core temperatures indicated a significant difference according to body part (p=.033), time of measure (p<.001) and the reciprocal interaction between body part and time of measure (p<.027). The core temperatures were highest at tympany location, lowest at nasopharynx. The amount of temperature change was least for the esophagus ($36.10{\sim}36.33^{\circ}C$), followed by nasopharynx and tympany. Conclusion: The esophageal core temperature showed the highest stability followed by nasopharyngeal and tympanic temperature. Therefore, close observations are required between 10~20minutes after the beginning of the operation.

체온측정방법의 정확도와 간호시간 및 발열감별 타당도 비교 (Accuracy of Temperature Measurements, Nursing Time for Measuring Temperature and the Validity of Fever Detection)

  • 송경애;강성실;황진순;김명자
    • 기본간호학회지
    • /
    • 제5권1호
    • /
    • pp.33-45
    • /
    • 1998
  • The aim of this study was to investigate what is the most accurate and quick temperature measurement among rectal, auxiliary and tympanic routes. The body temperatures of 86 preform infants in incubators, a controlled environment, were measured at three different sites. The measurements were taken to examine the accuracy of the temperatures, proper nursing time for measuring the temperatures and the validity of fever detection. The results were as follows : 1. The mean temperature was significantly lower in the auxiliary site($36.71^{\circ}C$) and higher in the tympanic site($37.27^{\circ}C$) than in the rectal site($37.03^{\circ}C$). 2. The mean nursing time for measuring body temperature was significantly longer in the auxiliary site(171.65 seconds) and shorter in the tympanic site(17.70 seconds) than in the rectal site(83.33 seconds). 3. The nursing time for measuring body temperature included the time needed for preparation, measuring, as well as the post-measuring time. It was found that the time required to prepare for measuring the temperature of the rectal site was significantly longer than for other sites. In addition, the time needed to measure the temperature of the auxiliary site was significantly longer than in the other sites. Finally, the nursing time needed for measuring the auxiliary temperature(171.65 seconds) was the longest among the three sites whereas the nursing time for the tympanic site was the shortest(17.70 seconds). 4. Rectal temperature was significantly correlated to the tympanic(r=0.67) and auxiliary temperatures(r=0.69). Tympanic temperature was also significantly correlated to the auxiliary temperature(r=0.74). 5. The sensitivity, specificity, positive and negative predictive values of tympanic temperatures for detecting fever were 1.00, 0.80, 0.24, and 1.00, respectively. Those for the auxiliary temperatures were 0.00, 0.99, 0.00, and 0.94, respectively. Thus the level of fever detection was lower in the auxiliary temperatures than in tympanic temperatures. The above findings indicate that the tympanic method of temperature measurement offers a useful alternative to conventional methods.

  • PDF

고수온(27-33℃)에서 사육한 쏘가리(Siniperca scherzeri) 치어의 성장 및 체조성 변화 (Growth and Body Composition of Mandarin Fish Siniperca scherzeri Reared at High Water Temperatures)

  • 김이오;이상민
    • 한국수산과학회지
    • /
    • 제50권6호
    • /
    • pp.756-761
    • /
    • 2017
  • This study investigated the growth of juvenile mandarin fish Siniperca scherzeri, reared at high water temperatures. Feed-trained juvenile fish were reared at four water temperatures: 27, 29, 31, and $33^{\circ}C$. The fish were fed to apparent satiation twice daily using pelleted diet. After 10 weeks of feeding trial, the survival exceeded 98% in all groups. The weight gain of fish reared at $31^{\circ}C$ was higher than for fish reared at the other temperatures. The feed efficiency and protein efficiency ratio of fish reared at 29 and $31^{\circ}C$ were higher than for the fish reared at 27 and $33^{\circ}C$. The daily feed intake of fish reared at 27 and $33^{\circ}C$ was higher than for the 29 and $31^{\circ}C$ groups. The whole body moisture content of fish reared at $33^{\circ}C$ was higher than in the $27^{\circ}C$ group. The whole body crude protein and lipid contents of fish reared at $27^{\circ}C$ were higher than in the $33^{\circ}C$ group. The results indicate that suitable rearing water temperature was $31^{\circ}C$ for optimal growth and feed efficiency of juvenile mandarin fish under the experimental conditions.

여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색 (Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions)

  • 정재연;강주호;설선홍;이주영
    • 한국의류산업학회지
    • /
    • 제22권2호
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.