• Title/Summary/Keyword: Body Sensor

Search Result 930, Processing Time 0.032 seconds

Cluster Topology Algorithm for Efficient Data Transmission in Wireless Body Area Network based on Mobile Sink (WBAN 환경에서 효율적인 데이터 전송을 위한 모바일 싱크기반의 클러스터 토폴로지 알고리즘)

  • Lee, Jun-Hyuk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.56-63
    • /
    • 2012
  • The WBAN technology means a short distance wireless network which provides each device interactive communication by connecting devices inside and outside of body. Standardization on the physical layer, data link layer, network layer and application layer is in progress by IEEE 802.15.6 TG BAN. Wireless body area network is usually configured in energy efficient using sensor and zigbee device due to the power limitation and the characteristics of human body. Wireless sensor network consist of sensor field and sink node. Sensor field are composed a lot of sensor node and sink node collect sensing data. Wireless sensor network has capacity of the self constitution by protocol where placed in large area without fixed position. Mobile sink node distribute energy consumption therefore network life time was increased than fixed sink node. The energy efficient is important matter in wireless body area network because energy resource was limited on sensor node. In this paper we proposed cluster topology algorithm for efficient data transmission in wireless body area network based mobile sink. The proposed algorithm show good performance under the advantage of grid routing protocol and TDMA scheduling that minimized overlap area on cluster and reduced amount of data on cluster header in error prone wireless sensor network based on mobile sink.

Predict the engine Acceleration by Analyzing the Rigid Body Motion (강체 운동 해석을 통한 엔진의 가속도 예측)

  • Kim, Byung-Hyun;Park, Jong-Ho;Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.351-356
    • /
    • 2011
  • Some materials show the character of rigid body in low frequency spectrum. The rigid body motions are consisted of translational and rotational motions. Especially, we can get the acceleration or displacement of a random point in the rigid body by analyzing rigid body transfer matrix at the car's engine and power train. Actually it is difficult to measure the acceleration by attaching the sensor inside of the engine and power train. So the hard to predict acceleration data can be achieved attaching the sensor on the outside of the engine and power train by analyzing the data of rigid body motion which the engine is operated using dynamo. Also this paper will show the change of predicted data and accuracy variation by not using all the measured data but a few exceptions of the point number.

  • PDF

Effect of P(VDF/TrFE) Film Thickness on the Characteristics of Pyroelectric Passive Infrared Ray Sensor for Human Body Detection (P(VDF/TrFE) 필름의 두께에 따른 인체 감지형 초전형 PIR 적외선 센서의 특성)

  • Kwon, Sung-Yeol
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.114-117
    • /
    • 2011
  • A thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated and then thin 1.6 ${\mu}m$ thickness P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated also. These thick and thin P(VDF/TrFE) film pyroelectric infrared ray sensor was mounted in TO-5 housing to detect infrared light of 5.5 ~ 14 ${\mu}m$ wavelength for human body detecting with each other. The noise output voltage of the thick P(VDF/TrFE) film pyroelectric infrared ray sensor were 380 mV and NEP(noise equivalent power) is $3.95{\times}10^{-7}$ W which is the similar value with the commercial pyroelectric infrared ray sensor using ceramic materials as a sensing material. The NEP and specific detectivity $D^*$ of the thin P(VDF/TrFE) film pyroelectric infrared ray sensor were $2.13{\times}10^{-8}$ W and $9.37{\times}106$ cm/W under emission energy of 13 ${\mu}W/cm^2$ respectively. These result caused by lower thermal diffusion coefficient of a thin 1.6 ${\mu}m$ thickness PVDF/TrFE film than the thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor.

Unconstrained Estimation of Body Postures on Bed Using Polyvinylidene Fluoride Film-based Sensor (PVDF 필름 기반 센서를 이용한 무구속적인 누운 자세 추정)

  • Seo, Sangwon;Hwang, Su Hwan;Yoon, Hee Nam;Jung, Da Woon;Choi, Jae Won;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.169-176
    • /
    • 2014
  • As body postures on bed affects various sleep related diseases, it is considered as important information when monitoring sleeping in daily life. Though there have already been a few approaches to monitor body postures on bed conventionally, the development for simple and unconstrained methods is still needed to realize the long-term daily monitoring. Focusing on the fact that ballistocardiogram changes depending on the body postures on bed, we developed a novel method to estimate body posturesusing extremely simple, film-type ballistocardiogram sensor which is based on polyvinylidene fluoride(PVDF) film. With 10 subjects, we performed two experiments. One was for an estimation test to show that body postures on bed can be estimated by ballistocardiogram, and the other was for a reproducibility test to present the feasibility of ballistocardiogram based body postures monitoring. To estimate body postures on bed, we made an individual template set of body postures by designating one ballistocardiogram (BCG) sample as a template in each postures. Then, we calculated Pearson's correlation coefficients between a sample and each templates and estimated the body posture of the sample by choosing a posture which corresponds to the most significant correlation coefficients. As a result, we estimated body postures on bed with 99.2% accuracy in average and found that the estimation using ballistocardiogram is reproducible.

Black Body Design and Verification for Non-Uniformity Correction of Imaging Sensor and Uncertainty Analysis (영상센서의 비균일 응답특성 보정을 위한 흑체 설계 및 성능검증과 보정오차 분석)

  • Shin, Somin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.240-245
    • /
    • 2013
  • Each pixel of InfraRed(IR) sensor differently responds to IR light as time elapses or the sensor on/off operation is repeated. As a result, the quality of IR sensor image is deteriorated, and therefore NUC(Non-uniformity Correction) is periodically needed for IR sensor. In this paper, in order to perform NUC in the Satellite, on-board V-grooved blackbody is designed with a baffle so that the emissivity of black body is to be higher than 0.995 as well as the temperature deviation is less than $1^{\circ}C$ in the range of the infrared wave length from 3.3 to $5.2{\mu}m$. To check its performance, the emissivity and the surface temperature of the blackbody by TRT(Transfer Reference Thermometer) and IR Micrometer scanner are measured, respectively. From the results, black body design is verified and the uncertainty of NUC is estimated through the measurement results.

A Basic Study on Implementing Optimal Function of Motion Sensor for Bridge Navigational Watch Alarm System

  • Jeong, Tae-Gweon;Bae, Dong-Hyuk
    • Journal of Navigation and Port Research
    • /
    • v.38 no.6
    • /
    • pp.645-653
    • /
    • 2014
  • A Bridge Navigational Watch Alarm System (hereafter 'BNWAS') is to monitor and detect if an officer of watch(hereafter 'OOW') keeps a sharp lookout on the bridge. The careless lookout of an OOW could lead to marine accidents. For this reason on June 5th, 2009, IMO decided that a ship is equipped with a BNWAS. However, an existing BNWAS gives the OOW a lot of inconvenience and stress in its operation. It requires that the OOW should press reset buttons to confirm their alert watch on the bridge at every three to twelve minute. Many OOWs have complained that at some circumstances they cannot focus on their bridge activities including watch-keeping due to a lots of resetting inputs of BNWAS. Accordingly, IMO has allowed the use of a motion sensor as a resetting device. The motion sensor detects the movements of human body on the bridge and subsequently sends reset signals directly to BNWAS automatically. As a result, OOWs can work uninterrupted. However, some of classification societies and flag authorities have a slightly different stance on the use of motion sensor as a resetting method for BNWAS. The reason is that the motion sensor may trigger false reset signals caused by the motion of objects on the bridge, especially a slight movement such as toss and turn of human body which can extend the period of careless watch. As a basic study to minimize the false reset signals, this paper proposes a simple configuration of BNWAS, which consists of only three motion sensors associated with 'AND' and 'OR' logic gates. Additionally, several considerations are also proposed for the implementation of motion sensors. This study found that the proposed configuration which consists of three motion sensors is better than an existing one by reducing false reset signals caused by a slight movement of human body in one's sleep. The proposed configuration in this paper filters false reset signals and is simple to be implemented on existing vessels. In addition, it can be easily installed just by a basic electrical knowledge.

Numerical Investigation of Temperature Uniformity and Estimation Accuracy for MEMS-based Black Body System (MEMS 기반 흑체 시스템의 온도 균일도 및 추정 정확도의 수치 해석적 검토)

  • Chae, Bong-Geon;Kim, Tae-Gyu;Lee, Jong-Kwang;Kang, Suk-joo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.455-462
    • /
    • 2016
  • Output Characteristics of the spaceborn image sensor such as infrared(IR) sensor are varied according to time elapses and sensor repetition on/off operation. As a result, the quality of IR sensor image is decreased. Therefore, spaceborne image sensor require a periodic calibration using a black body system by correcting a non-uniformity of the sensor. In this paper, we proposed a MEMS-based black body system that can implement the high temperature uniformity at various standard temperatures ranging from low to high temperature and easily estimate the representative surface temperature. In addition, it has advantages lightweight, low-power and high accuracy. The feasibility of the proposed MEMS-based black body system was verified through the thermal analysis.

Adjusting the Sensitivity of an Active Pixel Sensor Using a Gate/Body-Tied P-Channel Metal-Oxide Semiconductor Field-Effect Transistor-Type Photodetector With a Transfer Gate (전송 게이트가 내장된 Gate/Body-Tied P-Channel Metal-Oxide Semiconductor Field-Effect Transistor 구조 광 검출기를 이용한 감도 가변형 능동 화소 센서)

  • Jang, Juneyoung;Lee, Jewon;Kwen, Hyeunwoo;Seo, Sang-Ho;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.114-118
    • /
    • 2021
  • In this study, the sensitivity of an active pixel sensor (APS) was adjusted by employing a gate/body-tied (GBT) p-channel metal-oxide semiconductor field-effect transistor (PMOSFET)-type photodetector with a transfer gate. A GBT PMOSFET-type photodetector can amplify the photocurrent generated by light. Consequently, APSs that incorporate GBT PMOSFET-type photodetectors are more sensitive than those APSs that are based on p-n junctions. In this study, a transfer gate was added to the conventional GBT PMOSFET-type photodetector. Such a photodetector can adjust the sensitivity of the APS by controlling the amount of charge transmitted from the drain to the floating diffusion node according to the voltage of the transfer gate. The results obtained from conducted simulations and measurements corroborate that, the sensitivity of an APS, which incorporates a GBT PMOSFET-type photodetector with a built-in transfer gate, can be adjusted according to the voltage of the transfer gate. Furthermore, the chip was fabricated by employing the standard 0.35 ㎛ complementary metal-oxide semiconductor (CMOS) technology, and the variable sensitivity of the APS was thereby experimentally verified.

Zero locus of a beam with varying actuator and sensor locations and dynamical analysis (Actuator와 sensor의 위치 변화에 따른 beam의 zero궤적과 동역학적 해석)

  • 이영재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.474-478
    • /
    • 1992
  • The non-rational transfer function of a Bernoulli-Euler beam, as an important component of a flexible structure, is analyzed. The true pattern of zeros of that transfer function is investigated as a function of sensor and actuator seperation. Translational displacement sensors are used for two cases in which a force input and a moment input are seperately applied. When the displacement sensor is located at a certain point, the first pair of zeros on the real axis of the s-plane arrive at the origin and cancel the rigid-body mode. The location of the translational displacement sensors on the beamat which the rigid-body mode of the beam is unobservable is analyzed as the center of percussion and is uniquely located for each case. If sensor is moved beyond such a point, a pair of zeros appear on the imaginary axis and move away from the origin along the imaginary axis of the s-plane.

  • PDF

Wearable Human Health-monitoring Band using Inkjet-printed Flexible Temperature Sensor

  • Han, Dong Cheul;Shin, Han Jae;Yeom, Se Hyeok;Lee, Wanghoon
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.301-305
    • /
    • 2017
  • This paper presents a wearable human health-monitoring band. The band consists of a body temperature detector (BTD) and a hear rate detector (HRD). The BTD and HRD are realized using an inkjet-printed flexible temperature sensor and a commercial heart rate sensor module, respectively. The sensitivity of the fabricated BTD was found to be $-31/^{\circ}C$ with a linearity of 99.82%. The HRD using the commercial heart rate sensor module has a good performance with a standard deviation of 0.85 between the data of a commercial smart watch and the fabricated HRD.