• 제목/요약/키워드: Body Scan

검색결과 569건 처리시간 0.025초

Side Scan Sonar 실무이론과 현장조사에 적용 (Practical theory and ocean survey application of side scan sonar)

  • 김성렬;이용국;정백훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.201-204
    • /
    • 2006
  • In the side scan sonar method, use is made of the back-scattering, at low grazing angles of incidence to the seabed, of relatively high-frequency acoustic waves radiated in a fan-shaped beam from a transducer contained in a towed body. The fan beam is oriented so that the wider angle is in the vertical plane (scan range) and the narrower angle in the horizontal plane (beam width) with the axis of the beam normal to the ship track. The display of the returns is usually realized as a series of closely spaced intensity-modulated lines on a paper recorder or computer screen display. In this way a two-dimensional picture of the seabed is build up.

  • PDF

3D 인체 스캔 데이터를 활용한 체형별 인대모형 개발에 관한 연구 (Development of Bodice Dress Forms by Body Types for Women in Thirties Applying 3D Body Scan Data)

  • 서동애;오설영
    • 한국콘텐츠학회논문지
    • /
    • 제12권9호
    • /
    • pp.136-145
    • /
    • 2012
  • 다양한 체형을 지니고 있는 소비자들에게 만족스러운 착용감을 주는 기성복 생산을 위해서는 체형 특성이 반영된 원형 제작이 필요하다. 인체는 체형에 따라 곡면의 형태가 달라지므로, 인체의 곡면 형태를 세분화하여 그 특성을 원형 설계에 반영할 필요가 있다. 그러나 기성복에서는 개인의 체형별 특징을 일일이 반영하기 힘드므로, 기성복 원형 제작에 활용 가능한 체형별 인대 모형이 요구되고 있다. 따라서 본 연구에서는 삼차원 인체스캔 데이터를 활용하여 체형을 분석하고 각 체형에 따른 인대모형 개발 방법을 제시하였다. 30대 성인 여성의 상반신 삼차원 인체 형상 자료를 분석한 결과, 체형 특성은 보통체형, 비만체형, 마른체형으로 분류되었다. 상반신을 기준선을 두어 나누어 계측한 결과, 체형에 따라 유의적인 차이가 나타났다. 계측된 각 부위별 삼차원 인체 치수를 기본 원형 설계 시 허리다트 위치 및 분량 설정에 반영하여 체형별 상반신 기본 원형을 제작하였으며, 이를 바탕으로 입체모형을 제작하여 스캔, 모델링 작업을 거쳐 체형에 맞는 원형 인대 모형을 제시하였다. 인대 모형은 인체의 입체 형상을 만들기 위한 다트선을 포함하고 있어 기본 원형 제작 및 원형 활용에 도움이 될 것으로 사료된다.

3D 인체 스캔 데이터를 이용한 11~15세 성장기 여성의 유방형태에 따른 유형 분류 (Classification of Breast Shape of Women Aged 11~15 Using 3D Body Scan Data)

  • 한정정;송화경;이규선
    • 한국의류산업학회지
    • /
    • 제19권6호
    • /
    • pp.786-794
    • /
    • 2017
  • The purpose of this study is to analyze and classify breast shape of women aged 11~15 using 3D body scan data. In this study, 250 women's body scans were selected from the 6th Size Korea dataset, and 30 items from each of the scan were measured using RapidForm XOR 3 program. The principal component analysis and cluster analysis were conducted using statistical program SPSS 17.0. The five principal components were identified; breast drooping and breast capacity, size from chest to under bust area, breast protrusion, breast height, and under breast angle & outer distance of breast. As the results of cluster analysis, woman's breast types were classified into four types. The breast type 1 was protrusion type (25.1%) which is considered as the breast maturity stage. The breast type 2 had the most drooped breast covering a large area (20.2%). The breast type 3 had the least prominent breast with a highest nipple point, which was considered as the early breast development stage (38.9%). The breast type 4 had the obesity of the chest and breast circumferences with the slightly prominent and the least drooped breast (15.8%). This study can provide fundamental information to develop sizing system and brassiere pattern for junior girls.

Application Two-Dimensional Pattern Development of Cycling Tights based on the Three-Dimensional Body Scan Data of High School Male Cyclist

  • Park, Hyunjeong;Do, Wolhee
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.595-606
    • /
    • 2020
  • This study develops an optimal two-dimensional (2D) pattern from three-dimensional human scan data by considering the cycling posture and dermatome of high school male cyclists. By analyzing the body surface change in the cycling posture and considering the dermatome of the lower limbs, the optimal cutting line setting and the development of cycling tights for individual cyclists were presented to provide data that could be used in the clothing industry. We designed three cycling tights to solve the size unsuitability. 3D design 1 is a non-extension design based on the analysis of the 3D human body scan data, in which parts were connected diagonally from the front of the knee to the back of the knee. 3D design 2 removed both the front and back to reduce air resistance during cycling. 3D design 3 did not have a cutting line on the front panel because of the air resistance during cycling in the front area. We analyzed the garment pressure for 8 points of lower body and performed a subjective evaluation of the 3D designed tights and the current cycling tights. The 3D design 1 in this study was well received in the omphalion, thigh, and hip area, while 3D design 3 was well received in the omphalion, thigh, hip, and bottom bands. Therefore, the LoNE of 3D design 1 was applied to the front, and the hip cutting line of 3D design 3 was applied to the back.

고주파요법이 부분비만치료에 미치는 영향 (Effects of High Frequency Therapy on Localized Obesity)

  • 신승우;최영민;심우진;이형철;김길수
    • 한방비만학회지
    • /
    • 제6권2호
    • /
    • pp.75-83
    • /
    • 2006
  • Objectives : This study was performed to identify the effects of high frequency therapy on localized obesity. Methods : This trial was carried out in 12 volunteers. Volunteers were divided into 3 groups; upper arm group (n=4), thigh group (n=4) and abdomen group (n=4) according to local obesity type. Body weight and body fat were measured by Inbody 720 and CT (Computed Tomography) immediately before and following high frequency therapy. Diathermy was performed twice a week for 4 weeks for a total of 8 treatments. Results : In the upper arm group, body weight, body fat mass, fat area by CT scan and circumference were increased after treatment but not significantly (p>0.05). In the thigh group, body weight, body fat mass and circumference were decreased and fat area by CT scan was increased but both not significantly (p>0.05). In the abdomen group, significant differences were not found despite decreases in body weight, body fat mass, visceral fat and subcutaneous fat after diathermy (p>0.05). Conclusions : There was no significant effects of high frequency therapy on localized obesity.

  • PDF

천해역 해저탐사 및 영상분석 기법 소개 (An Introduction to the Underwater Survey Operations using a Side Scan Sonar System)

  • 주영석;우종식
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.156-159
    • /
    • 2001
  • Recently, side scan sonar system has been developed and operated to survey cable laying, sunken bodies, geometry of sea bottom and so on. It uses the acoustic signals, which are emitted from two transducer arrays, left and right sides, to get geometric information of the specified area. This system consists of transceiver board, towed body, deck unit and GPS receiver. The transceiver board, nested in a watertight canister, controls the transmitting and receiving of the acoustic pulses from transducer arrays. After receiving the scattered signals, it processes BP(Band Pass) filtering, AGC(Automatic Gain Control), TVG(Time Varying Gain) and Heterodyne. The deck init has the signal processing part, A/D converter, power supplier, and real-time monitoring part. The towed body has been designed to satisfy the optimal hydrodynamic behavior during towing, In this paper, brief introductions on the design theory of transceiving part and some results from the field which have been operated recently will be introduced.

  • PDF

PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가 (The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT)

  • 김진영;이승재;정석;박민수;강천구;임한상;김재삼
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.63-67
    • /
    • 2015
  • 환자의 호흡에 의해 발생되는 인공물의 감소를 위한 다양한 방법들 중 호흡동조 시스템(이하 Q static scan)과 비교하여 CTAC Shift 보정방법, Additional scan(추가 검사방법)을 평가해보고자 한다. 본 연구는 2015년 2월에서 5월까지 본원을 내원한 환자들 중 영상에서 호흡에 의해 인공물이 발생한 환자 10명을 대상으로 진행하였으며 장비는 PET-CT Discovery 710 (GE Healthcare, MI, USA)과 호흡동조 시스템인 Varian사의 RPM system을 사용하였다. 환자는 24시간동안의 운동금지, 12시간동안 커피와 담배 금지, 8시간동안 금식을 한 후 충분한 수분을 섭취하고 도착시 혈관확보를 한 후 혈당 체크를 진행하며 $^{18}F$-FDG를 kg당 5.18 Mbq을 주사하였다. 그 후 1시간동안 안정을 취하고, 배뇨 후 검사를 진행하였다. CT조건은 관전압 120 kVp와 관전류 60 mAs, DFOV는 70 cm, Matrix size는 $192{\times}192$으로 모두 동일하게 진행하였다. 인공물이 발생한 영상을 기준으로 Additional scan, 호흡동조 시스템을 연동한 Q static scan, CTAC Shift 보정방법을 통해 영상화하였다. 각각의 영상에서 인공물의 감소를 비교하였으며, 육안적 평가와 SUVmax의 변화를 측정하였다. 인공물이 발생한 Whole body scan(WBS)을 통해 얻은 영상 대비 CTAC Shift 보정방법을 통해 얻은 영상의 경우 12~56%, Q static scan 영상은 17~54%, Additional scan 영상은 -27~46%의 변화율을 보였다. Blind Test에서는 CTAC Shift 보정영상이 4점으로 가장 높은 점수를 얻었고 Q static scan 영상이 3.5점, Additional scan 영상이 3.4점의 점수를 얻었다. Oneway ANOVA 검정을 통해 기준이 된 WBS scan 영상과 세 가지 Scan방법간에 유의한 차이를 보였으며(p<0.05) 세 가지 Scan방법간에는 유의한 차이를 보이지 않았다(p>0.05). 그러나 Blind test에서는 세 가지 Scan방법간의 유의한 차이를 보였다. Additional scan과 Q static scan은 CTAC Shift 보정 방법보다 시간이 소요되며 환자에게 CT 재촬영에 의한 과피폭이 우려되며 Q static scan은 호흡의 기복이 심하거나 통증으로 인해 호흡 주기가 불규칙한 환자의 경우 적용하기에 어려움이 있다. CTAC Shift 보정 방법의 경우 제한적으로 보정이 가능하며 그 범위 또한 제한적이다. 이를 보완하기 위해 각 병원의 시스템을 적절히 이용하고 각 방법의 장점의 여러 요소들을 발전시킨다면 진단적 가치를 높이기 위한 방법의 하나로써 유용할 것으로 사료된다.

  • PDF

의류 패턴 설계를 위한 삼차원 인체 체표면 스캔 데이터 활용에 관한 연구 (A Study on the Use of 3D Human Body Surface Shape Scan Data for Apparel Pattern Making)

  • 천종숙;서동애;이관석
    • 복식문화연구
    • /
    • 제10권6호
    • /
    • pp.709-717
    • /
    • 2002
  • In the apparel industry, the technology has been advanced rapidly. The use of 3D scanning systems fur the capture and measurement of human body is becoming common place. Three dimensional digital image can be used for design, inspection, reproduction of physical objects. The purpose of this study is to develop a method that drafts men's basic bodice pattern from scanned 3D body surface shape data. In order to pursue this purpose the researchers developed pattern drafting algorithm. The 3D scanner used in this study was Cyberware Whole Body Scanner WB-4. The bodice pattern drafting algorithm from 3D body surface shape data developed in this study is as follows. First, convert geometric 3D body surface data to 3D polygonal mesh data. Second, develop algorithm to lay out 3D polygonal patches onto a plane using Auto Lisp program. The polygon meshes are coplanar, and the individual mesh is continuously in contact with next one The bodice front surface shape data in polygonal patches form was lined up in bust and waist levels. The back bodice was drafted by lining up the polygonal mesh in scapula, chest, and waist levels. in the drafts, gaps between polygons were formed into the darts.

  • PDF

3차원 하반신 스캔데이터를 이용한 승마바지의 맞음새 분석 (An analysis on the Fit Preferences of Breeches using 3D Lower Body Scan data)

  • 강미정;권영아
    • 한국의류산업학회지
    • /
    • 제15권6호
    • /
    • pp.1000-1009
    • /
    • 2013
  • Well-fitting riding breeches provide a comfortable ride. Horse-riding breeches should fit the lower body with patches located on the inside of hip and knees to prevent tears and slips. This study provides information about the fit of women's breeches using 3D human body scan data wearing commercially available two breeches according to posture. To get information about breeches fit, we measured the angle of waist line, the length, and the area of the breeches fit on four 20's women. This research showed the problem which was down for waist back line in the case of the horseback riding pose. The back waistline of the riding breeches should be raised compared to the front waistline; subsequently, an increased waistline angle results in less back waistline decrease. The breeches have plenty of length from back waist to crotch so the breech fit can be improved. The thigh circumference increased when riding in the front; therefore, good elasticity of the weft direction of the fabric is recommended. The length increase and the peripheral increase of the front knee significantly increased the surface area of the knee; consequently, knee patch material should be a two-way elastic fabric in all directions to enhance comfort according to riding motion.

Triangle Simplification에 의한 3D 인체형상분할과 삼각조합방법에 의한 2D 패턴구성 (Method of 3D Body Surface Segmentation and 2D Pattern Development Using Triangle Simplification and Triangle Patch Arrangement)

  • 정연희;홍경희;김시조
    • 한국의류학회지
    • /
    • 제29권9_10호
    • /
    • pp.1359-1368
    • /
    • 2005
  • When we develop the tight-fit 2D pattern from the 3D scan data, segmentation of the 3D scan data into several parts is necessary to make a curved surface into a flat plane. In this study, Garland's method of triangle simplification was adopted to reduce the number of data point without distorting the original shape. The Runge-Kutta method was applied to make triangular patch from the 3D surface in a 2D plane. We also explored the detailed arrangement method of small 2D patches to make a tight-fit pattern for a male body. As results, minimum triangle numbers in the simplification process and efficient arrangement methods of many pieces were suggested for the optimal 2D pattern development. Among four arrangement methods, a block method is faster and easier when dealing with the triangle patches of male's upper body. Anchoring neighboring vertices of blocks to make 2D pattern was observed to be a reasonable arrangement method to get even distribution of stress in a 2D plane.