• Title/Summary/Keyword: Body Scan

Search Result 569, Processing Time 0.028 seconds

A Study on Development of Men's Formal Jacket Pattern by 3D Human Body Scan Data -A Focus on Men's in their Late 30s- (3D 인체데이터를 활용한 남성 정장재킷 패턴개발 연구 -30대 후반 남성을 중심으로-)

  • Shin, Kyung-hee;Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.3
    • /
    • pp.440-458
    • /
    • 2019
  • Based on a 3D body data and pattern comparison analysis, this study developed a formal jacket pattern for men in their late 30s. In order to select the representative type of men in their late 30s, factor analysis and cluster analysis were conducted on data form 319 men, 35 to 39 years old using the anthropometric data from The 7th Size Korea (2015) as the representative body type. The surface of the body surface was developed using a 3D human shape of a male in his 30s in The 6th Size Korea (2010). Then the shape was changed to a flat pattern that confirmed the necessary elements for setting the shape and dimension. Cluster analysis revealed type B as the representative type because it showed the best shape characteristics for men in the late 30s. The drafting method of the final research pattern is as follows. Jacket length: stature/2.5cm, back length: stature/5+8.5cm (constant)], armhole depth: [stature/ 7-1.5cm (constant)], back width: [C/9+9.5cm (constant)]+1cm (ease), front width: [C/9+8.5cm (constant)]+1cm (ease), armscye depth: C/8, front waist darts: 1cm, front closure amount: 2cm.

Analysis on the Effects and Influences of Mindfulness Based Breathing and Body Scan for Elderly Women's Attentive Concentration (마음챙김 호흡과 신체이완이 여성노인의 주의집중력에 미치는 영향 분석)

  • Kim, Yun-Keum;Yi, Seon-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.173-179
    • /
    • 2015
  • This study is analized with how Mindfulness Based Breathing and Body Scan influences to elderly women's attentive concentration measured by 2-channel system EEG(Electroencephalogram) which method is objectively and determinately. The subjects in this study are 60 aged over 65years of elderly women in K city, who were divided into two groups; such as 30 of the experimental group and 30 of the control group checked by EEG before and after the treatment. The study started from March to July in 2013. The treatment was conducted by ones a week, 60minutes a time for 16 weeks. The result in experimental group is indicated as followed. The Attention Quotient Lt(69.61/70.85, p<.024) showed higher score after treatment, and Attention Quotient Rate Lt(4.22/3.75, p<.037), Attention Quotient Rate Rt(4.29/3.70, p<.019) did show statistically lower score after treatment. Attention Quotient is shown attentive concentration and awareness in the brain. Therefore, Mindfulness Based Breathing and Body Scan is proved the value and efficiency for activating elderly women's attentive concentration by a way of practical using in neuroscience.

A Study of Bone Uptake According to Renal Function in the Whole Body Bone Scan (전신 뼈 검사에서 신장 기능에 따른 뼈 섭취율에 대한 고찰)

  • Cho, Yong-In;Jang, Dong-Gun;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.299-304
    • /
    • 2013
  • Whole body bone scan has been used to confirm bone metastasis and follow-up study with radio isotope. However, if the factors related to $^{99m}Tc$ uptake and waiting time for study are inappropriate, it would be image of low quality. The purpose of present study was to investigate correlation between the evaluation index of renal function and uptake of radiopharmaceuticals. The population for this retrospective study consisted of 387 patients who underwent whole body bone scan between June 2012 and December 2012. As a result of quantitative and qualitative analysis, we were able to confirm that GFR of less than normal range and creatinine levels in blood of more than average are more likely to be under the mean uptake rate. As a result of analysis on the indicator affecting soft-tissue and bone uptake, the correlation of all elements was somewhat low. Also there are no statistically significances due to the other parameters we did not deal with. Therefore, further research on additional factors is needed for exact study and improvement of the image quality.

Discrepancy of Bone Metastases between F-18 FDG PET/CT and Bone Scan in a Patient with Prostate Cancer (전립선암에서 골전이 진단에 대한 F-18 FDG PET/CT와 골스캔의 불일치)

  • Choi, Seung-Jin;Kim, Chul-Soo;Byun, Sung-Su;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.275-278
    • /
    • 2006
  • We report the case of a 73-year-old man who had prostate cancer with bone metastases. Tc-99m HDP Whole body bone scan revealed multiple areas of increased bony uptake consistent with widespread bone metastases. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) demonstrated mild F-18 FDG uptake in the lymph nodes of neck, abdomen, and pelvis. However, abnormal F-18 FDG uptake was not seen in the skeletal system. Biopsy and immunohistochemical stains of left supraclavicular mass showed metastatic prostate adenocarcinoma. Currently, there are a few reported cases of F-18 FDG PET/CT evaluation of bone metastases in prostate cancer. We discuss the discrepancy between F-18 FDG PET/CT and bone scan in the detection of osseous metastases of prostate cancer.

Camurati-Engelmann's Disease on $^{99m}Tc$-MDP Bone Scan (Camurati-Engelmann 병의 뼈스캔 소견)

  • Yoon, Hai-Jeon;Oh, So-Won;Paeng, Jin-Chul;Lee, You-Kyung;Choi, In-Ho;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.596-599
    • /
    • 2009
  • A 24 year-old female presented for a $^{99m}Tc$-methylene diphosphonatae (MDP) whole body bone scan due to chronic pain in the bilateral lower extremities that has aggravated since 2002. She was diagnosed with Camurati-Engelmann disease (CED) based on the clinical and radiological findings in 2002, and she re-visited our institute to evaluate disease status at this time. CED is a rare autosomal dominant type of bone dysplasia characterized by progressive cortical thickening of long bones, and narrowing of medullary cavity, and thus presents with typical clinical symptoms and signs such as chronic pain in the extremities, muscle weakness, and waddling gait. On the $^{99m}Tc$-MDP bone scan performed to evaluate disease status, intense increased uptake was seen in the skull, facial bones, bilateral scapulae, bilateral long bones, and bilateral pelvic bones, which clearly demonstrated the extent of CED involvement.

Quantitative Evaluation on Optimal Scan Time of PET/CT Studies Using TOF PET (TOF 기법을 이용한 PET/CT 검사에서 적정 스캔 시간에 대한 정량적 평가)

  • Moon, Il-Sang;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2012
  • Purpose: To verify the optimal scan time per bed for clinical application, we evaluated the quality of $^{18}F$-FDG images with varying scan times in a phantom and 20 patients with 38 lesions using a Philips (TOF) PET/CT scanner. Materials and Methods: The PET/CT images of a NEMA IEC body phantom and 20 patients (16 males, 4 females) were acquired for 5 different scan times of 20-100 sec per bed with intervals of 20 sec. The activity ratio of hot spheres (diameter of 17 [H1], 22 [H2] and 28 [H3] mm) to the background region in the IEC body phantom was 8-to-1. The contrast recovery coefficient (CRC) and standard uptake value (SUV) based on ROIs of hot spheres and background region were calculated. The noise in each background region was estimated as the ratio of SD of counts to the mean counts in the background region. On the patient image, the injected dose of $^{18}F$-FDG was $444{\pm}74$ MBq and the SUVs in the 38 hot lesions were measured. Results: The two scan time groups (LT-60 [<60 sec] and GT-60 [${\geq}60$ sec]) were compared. In the phantom study, the coefficient of deviations (CVs, %) of CRC and SUV in LT-60 (H1: 14.2 and 7.3, H2: 11.4 and 7.8, H3: 4.9 and 3.2) were higher than GT-60 (H1: 8.9 and 2.8, H1: 8.2 and 5.0, H3: 2.0 and 1.6). In the patient study, the mean CV of CRC and SUV in LT-60 (4.0) was higher than GT-60 (1.2). Conclusion: This study showed that noise increased as the scan time decreased. High noise for the scan time <60 sec per bed yielded high variation of SUV and CRC. Therefore, considering PET/CT image quality, the scan time per bed in the TOF PET/CT scanner should be at least ${\geq}60$ sec.

  • PDF

Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application (Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가)

  • Kim, Jung-Soo;Kim, Byung-Jin;Kim, Jin-Eui;Woo, Jae-Ryong;Kim, Hyun-Joo;Shin, Heui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Purpose: The image processing method due to the algorism which is various portion nuclear medical image decision is important it makes holds. The purpose of this study is it applies hereupon new image processing method SIEMENS (made by Pixon co.) Onco. flash processing reconstruction and the comparison which use the image control technique of existing the clinical usefulness it analyzes with it evaluates. Materials & Methods: 1. Whole body bone scan-scan speed 20 cm/min, 30 cm/min & 40 cm/min blinding test 2. Bone static spot scan-regional view 200 kcts, 400 kcts for chest, pelvis, foot blinding test 3. 4 quadrant-bar phantom-20000 kcts visual evaluation 4. LSF-FWHM resolution comparison ananysis. Results: 1. Raw data (20 cm/min) & processing data (30 cm/min)-similar level image quality 2. Low count static image-image quality clearly improved at visual evaluation result. 3. Visual evaluation by quadrant bar phantom-rising image quality level 4. Resolution comparison evaluation (FWHM)-same difference from resolution comparison evaluation Conclusion: The study which applies a new method Onco. flash processing reconstruction, it will be able to confirm the image quality improvement which until high level is clearer the case which applies the method of existing better than. The new reconstruction improves the resolution & reduces the noise. This enhances the diagnostic capabilities of such imagery for radiologists and physicians and allows a reduction in radiation dosage for the same image quality. Like this fact, rising of equipment availability & shortening the patient waiting move & from viewpoint of the active defense against radiation currently becomes feed with the fact that it will be the useful result propriety which is sufficient in clinical NM.

  • PDF

Gamma Ray Detection Processing in PET/CT scanner (PET/CT 장치의 감마선 검출과정)

  • Park, Soung-Ock;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.125-132
    • /
    • 2006
  • The PET/CT scanner is an evolution in image technology. The two modalities are complementary with CT and PET images. The PET scan images are well known as low resolution anatomic landmak, but such problems may help with interpretation detailed anatomic framework such as that provided by CT scan. PET/CT offers some advantages-improved lesion localization and identification, more accurate tumor staging. etc. Conventional PET employs tranmission scan require around 4 min./bed position and 30 min. for whole body scan. But PET/CT scanner can reduced by 50% in whole body scan. Especially nowadays PET scanner LSO scintillator-based from BGO without septa and operate in 3-D acquisition mode with multidetectors CT. PET/CT scanner fusion problems solved through hardware rather than software. Such device provides with the capability to acquire accurately aligned anatomic and functional images from single scan. It is very important to effective detection from gamma ray source in PETdetector. And can be offer high quality diagnostic images. So we have study about detection processing of PET detector and high quality imaging process.

  • PDF

Evaluation of Image Quality by Parameter Change in Onco Flash (Onco Flash에서 매개변수 변화에 따른 영상의 질 평가)

  • Cha, Eun-Sun;Noh, Ik-Sang;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.30-34
    • /
    • 2009
  • Purpose: Many companies developed a lot of programs with continuous effort for program upgrading. With this acquire superior image quality for the purpose of quick examination and progress in spatial resolution. This study was to obtained clinical usefulness on a appropriate parameter of FWHM for speed and alpha value for superior image quality. Materials and Methods: Gamma camera by Siemens (e.cam) and spatial resolution phantom and four quadrant bar phantom used. Compared for FWHM by changed scan speed 15, 20, 25, 30, 35, 40 cm/min in scatter and non scatter in Onco Flash of spatial resolution phantom. Visual evaluation of count rate and bar phantom image for increased of alpha value of 10% in 0~100%. Results: FWHM by the scan speed was 9.37, 9.40, 9.28, 9.30, 9.31, 9.53 mm in the scatter. Count rate increased alpha value 10% increased. Visual evaluation was suitable to below 30%, Therefore spatial resolution improved on FWHM at the scan speed 25~35 cm/min applying for alpha value 30% in Onco Flash was average 9.3 mm less than FWHM of below 15 cm/min and above 40 cm/min. Conclusion: We found on appropriate parameter to progress of image quality. And there be a useful guideline for you that appropriate scan speed on vary in parameters of reduction on examination time and advancing image quality.

  • PDF

Characteristics and Classification of Armscye Circumference using 3D Scan Data (3차원 인체형상자료를 이용한 겨드랑둘레선의 형태특성 및 유형)

  • Choi, Kueng-Mi;Park, Sun-Mi;Nam, Yun-Ja;Jun, Jung-Ill;Ryu, Young-Sil
    • Fashion & Textile Research Journal
    • /
    • v.12 no.1
    • /
    • pp.80-85
    • /
    • 2010
  • The purpose of this study was to examine the characteristics of armscye circumference which will be used to develop total contents for the apparel industry. The subjects of this study were 16- to 49-year-old women whose 3D body shape data were analyzed. 72 length and length-ratio measurements were taken to each subject' armscye circumference. The used analysis methods are descriptive statistics, principal component analysis, and cluster analysis. The results are follows; 1. Considering the Length of armscye circumference, the result of principal component analysis were extracted 3 factors and those factors comprised 95% of total variance. As the result of the cluster analysis of factor scores, subjects were classified into 4 cluster by their size characteristic. 2. Considering the length-ratio of armscye circumference, the result of principal component analysis were extracted 5 factors and those factors comprised 96.45% of total variance. As the result of the cluster analysis of factor scores, subjects were classified into 5 cluster by their shape characteristic. So that, this research could be useful to manufacture garment which reflected 3D body figure and improved fitting.