• Title/Summary/Keyword: Body Resonance

Search Result 522, Processing Time 0.029 seconds

Magnetic Resonance Enhancement Pattern as a Predictor of Cement Volume in Vertebroplasty Procedures for Osteoporotic Fractures

  • Lee, Kye Ho;Yoo, Dong Soo;Kim, Yoon Ha
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.148-153
    • /
    • 2017
  • Purpose: To identify the differences between injected cement volumes during vertebroplasty procedures according to the enhancement pattern of pre-procedure magnetic resonance imaging (MRI) findings. Materials and Methods: Thirty-two patients who underwent 52 vertebroplasty procedures as well as pre-procedure contrast-enhanced spine MRI in the authors' institution were reviewed retrospectively. The 52 procedures were divided into two groups according to different enhancement patterns shown by pre-procedure MR imaging [E(+) and E(-)]. The volumes of the enhancing/non-enhancing portions of the fractured vertebral body shown by pre-procedural MR imaging were calculated and compared to the volumes of the injected cement during the vertebroplasty procedures. Results: The 52 injections included 28 (56%) in Group E(+) and 24 (44%) in Group E(-). The actual volume ratio of the injected cement to the volume of the non-enhanced or enhanced region calculated based on the contrast-enhanced MRI was $0.22{\pm}0.11(cc/cm^3)$ in the E(+) group and $0.93{\pm}0.62(cc/cm^3)$ in the E(-) group. The average amount of injected cement was significantly different between Group E(+) and Group E(-) (P < 0.001). In addition, the ratio of the injected cement amount to the volume of the enhanced or non-enhanced portion based on the contrast-enhanced MRI in Group E(-) was significantly higher than that of Group E(+) (P < 0.001). Conclusion: Different enhancement patterns shown by pre-procedure MRI can predictors of the injected cement volume during vertebroplasty procedures for osteoporotic fractures.

A Study on the Architectural Planning of the Magnet Resonance Imaging Unit in General Hospital (종합병원 자기공명단층촬영유니트에 관한 건축계획적 연구)

  • Yun Woo-Yong;Chai Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.89-96
    • /
    • 2006
  • Magnetic Resonance Imaging (MRI) scanner is the device to draw an image of conditions and the spread of various tissue in the body. It is used by making the patient into rounded superconductor and using high frequency which cause resonances. It uses superconduction magnet and high frequency that is non-ionizing radiation so can acquire biochemical, physical, and functional information of tissue. It is also very useful because it can scan tomography from many different angles to diagnose disease of a nervous system, the heart, and a skeletal structure. It also has advantages of that there is no risk of radiation exposure and the ability of observation on organizations such as brains, livers and the spinal cord of people. Since these features, the rate of use has been increased accordingly more considerations of the security are required when it plans. The weight of devices and the cover problem of the strong magnetic field which is occurred by magnetic resonance at the time of diagnosis can cause very important structure problems and architectural condition. That also the recent tendency which needs stronger equipment means that planning of the MRI unit should generally aim at purposing of the proximity for the device maintenance and up-grade and of further expansion. However there are not enough studies and data on the magnet resonance imaging in domestic hospitals. According to these reasons, this study has an object of indicating basic data on MRI unit plan standard and alternative proposals.

Design of a Variable Resonator for the Sacred Bell of the Great King Seongdeok (성덕대왕신종을 위한 가변형 명동의 설계)

  • Kim, Seock-Hyun;Jeong, Won-Tae;Kang, Yun-June
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.288-297
    • /
    • 2012
  • This study proposes a design model of the variable type resonator which corrects the temperature variance according to the season, in order to maximize the resonance effect in the Sacred bell of the Great King Seongdeok. In the bell, the 1st natural frequency (64 Hz) and the 2nd natural frequency (168 Hz) are the most important partial tones. Resonance conditions of the two components are determined for the internal acoustic cavity system, which consists of bell body cavity, gap and the resonator. Acoustic frequency response characteristics of the internal cavity are determined by the boundary element analysis using SYSNOISE. As an external factor, temperature variance according to the season largely influences the resonance condition and the length of the resonator should be controlled to maximize the resonance effect. As a measure, this study proposes a design model of the variable type resonator for the Sacred Bell of the Great King Seongdeok, which can control the length at the belfry according to the season.

Multiple Rice Body Formation in Subacromial and Subdeltoid Bursal Spaces

  • Shin, John Junghun;Lee, Jun-Pyo;Kim, Doo-Sup
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.2
    • /
    • pp.96-100
    • /
    • 2016
  • We encountered a rare condition of rice body in subacromial and subdeltoid spaces in a patient with unremarkable medical history. Although it is uncommon, there have been continued reports on its formation in certain type of infective and inflammatory arthritis. However, except for a traumatic event, evaluation yielded no known and conceivable cause for his chronic inflammatory bursitis. Relatively typical findings for rice body on magnetic resonance imaging have been described, and in our case the imaging prompted us to schedule early removal, which is generally accepted as the management of choice to prevent further progression of symptoms. The symptoms of the shoulder showed significant improvement, and a close follow-up schedule has been recommended for observation of recurrence and development of any foreseeable underlying cause.

Disseminated Cysticercosis

  • Park, Soo-Yong;Kong, Min-Ho;Kim, Jung-Hee;Song, Kwan-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.3
    • /
    • pp.190-193
    • /
    • 2011
  • Disseminated cysticercosis is a rare form of cysticercosis in which the cysticerci spread out through the whole body. We report the first case of a 39-year-old Mongolian with disseminated cysticercosis. He visited our hospital with generalized tonic-clonic seizure. After extensive investigation from brain computed tomography (CT), spine magnetic resonance imaging (MRI), whole body MRI and pathologic biopsy, he was diagnosed as having cysticercosis involving the brain, subcutaneous tissue, and skeletal muscles through the whole body. We treated him with the albendazole in which case the followed MRI showed that numbers of cystic lesions were copiously decreased. We report an unsual case of disseminated cysticercosis treated with medical therapy.

An Experimental Study on the Dynamic Characteristics of Onboard Machinery with Resilient Mounts (선내 탑재 마운팅 장비의 동특성에 관한 실험적 연구)

  • 김극수;최수현
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.2
    • /
    • pp.28-33
    • /
    • 2003
  • This study is performed to evaluate and design the dynamic characteristics of the onboard machinery with resilient mounts. To avoid resonance with onboard machinery and external force, it is necessary to calculate natural frequencies of the resilient mounting system more accurately. Natural frequencies of on board machinery are determined by rigid body properties(mass, moment of inertia, center of mass) of machinery and stiffness of mounts. But it is very difficult to calculate rigid body properties theoretically. And stiffness properties of rubber mounts vary with dynamic displacement, pre load, frequency and temperature, and so on. In this study, we have identified rigid body properties using experimental modal analysis and estimated dynamic stiffness of rubber mount for onboard machinery using measured vibration response during seatrial. We measured displacement excitation through deck under mounts and evaluated relationship between modes of resilient mounting system and main excitation sources of a ship.

Development of electric surgical machine by LC series resonance (LC 직렬공진에 의한 전기 수술기 개발)

  • Lee, Oh-Keol;Kim, Tae-Woo;Song, Ho-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.153-157
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows, Therefore, this treatise developed electricity living body formation operation appliance by home production, Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

Development of skin surgical machine by series resonance method (직렬공진에 의한 피부 수술기 개발)

  • Lee, Oh-Keol;Kim, Sang-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.127-132
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore, this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit. and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

Perilesional Steatosis in Ectopic Pancreas Mimicking Exogastric Mass : A Case Report (주변부 지방침윤으로 인해 외위장 종괴로 보이는 이소성 췌장: 증례 보고)

  • Nam, Mi Yeon;Kim, Mi Young;Kim, Yeo Ju;Suh, Chang Hae;Choi, Suk Jin;Cho, Jae Sung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.154-157
    • /
    • 2013
  • We report an unusual case of ectopic pancreas that appeared on radiologic images as a lobulated, submucosal mass enclosed by fat component in the gastric lower body. Although, ectopic pancreas including fat component is extremely rare, in the setting of gastric submucosal mass with containing perilesional fat, these findings should be considered in ectopic pancreas as part of the differential diagnosis.

Metabolic profiling study of ketoprofen-induced toxicity using 1H NMR spectroscopy coupled with multivariate analysis

  • Jung, Jee-Youn;Hwang, Geum-Sook
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.15 no.1
    • /
    • pp.54-68
    • /
    • 2011
  • $^1H$ nuclear magnetic resonance (NMR) spectroscopy of biological samples has been proven to be an effective and nondestructive approach to probe drug toxicity within an organism. In this study, ketoprofen toxicity was investigated using $^1H$-NMR spectroscopy coupled with multivariate statistical analysis. Histopathologic test of ketoprofen-induced acute gastrointestinal damage in rats demonstrated a significant dose-dependent effect. Furthermore, principal component analysis (PCA) derived from $^1H$-NMR spectra of urinary samples showed clear separation between the vehicle-treated control and ketoprofen-treated groups. Moreover, PCA derived from endogenous metabolite concentrations through targeted profiling revealed a dose-dependent metabolic shift between the vehicle-treated control, low-dose ketoprofen-treated (10 mg/kg body weight), and high-dose ketoprofen-treated (50 mg/kg) groups coinciding with their gastric damage scores after ketoprofen administration. The resultant metabolic profiles demonstrated that the ketoprofen-induced gastric damage exhibited energy metabolism perturbations that increased urinary levels of citrate, cis-aconitate, succinate, and phosphocreatine. In addition, ketoprofen administration induced an enhancement of xenobiotic activity in fatty oxidation, which caused increase levels of N-isovalerylglycine, adipate, phenylacetylglycine, dimethylamine, betaine, hippurate, 3-indoxylsulfate, N,N-dimethylglycine, trimethyl-N-oxide, and glycine. These findings demonstrate that $^1H$-NMR-based urinary metabolic profiling can be used for noninvasive and rapid way to diagnose adverse drug effects and is suitable for explaining the possible biological pathways perturbed by nonsteroidal anti-inflammatory drug toxicity.