• 제목/요약/키워드: Body Feature

검색결과 490건 처리시간 0.025초

가상 의복 코디네이션을 위한 개인 3D캐릭터의 구성 (Construction of the Personal 3D Characters for Virtual Clothing Coordination)

  • 최창석;김효숙
    • 한국의류학회지
    • /
    • 제27권9_10호
    • /
    • pp.1015-1025
    • /
    • 2003
  • This paper proposes a method for constructing the virtual characters adopting the personal body types for the clothing coordination. At first, the method produces the 38 kinds of the Korean 3D body models considering sex, ages and body types, and constructs model DB. We select a model similar to the personal body size from DB and deform the selected model according to body size. The method deforms the model linearly for height 12 items, width 6 items, depth 5 items and round 13 items, and constructs the personal character fitted to the personal body size. The preprocess for model deformation consists of grouping for body part and establishing the feature points. Linear deformation for each group leads us to easy construction of the virtual personal characters. This method has two advantages as follows: 1. Large reduction of man power, cost and time for DB construction of the body 3D models, since the preprocess permits us to effectively use the various body models whose geometrical structures are different, 2 Suitability to Web-based clothing coordination, since the body deformation method is simple and its speed is very high.

AR 전신 상호작용을 위한 이종 센서 간 좌표계 보정 기법 (Heterogeneous Sensor Coordinate System Calibration Technique for AR Whole Body Interaction)

  • 김항기;김대환;이동춘;이기석;백낙훈
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제12권7호
    • /
    • pp.315-324
    • /
    • 2023
  • 꾸준히 증가하는 노인성 질환 환자 대상으로 몰입형 디지털 콘텐츠를 이용한 쉽고 정확한 전신 재활 상호작용 기술이 필요하며, 본 연구에서는 이를 위해 홀로렌즈와 키넥트를 사용한 전신 상호작용 기술을 소개한다. 이를 위해 메쉬 특징점 기반 변환, AR 마커 기반 변환, 신체 인식 기반 변환 방법의 3가지 좌표 변환 방식을 제안한다. 메쉬 특징점 기반 변환은 공간 메쉬에 3개의 특징점을 지정하고 변환 행렬을 이용하여 좌표계를 일치시킨다. 이 방법은 수작업이 필요하여 사용성이 떨어지지만 정확도가 8.5mm로 상대적으로 높다. AR 마커 기반 방식은 홀로렌즈s와 키넥트가 동시에 인식하는 AR, QR마커를 사용하여 평균오차 11.2mm로 준수한 정확도를 달성했다. 신체 인식 기반 변환 방법은 두 기기가 동시에 인식하는 머리 혹은 HMD위치와 양 손 혹은 컨트롤러 위치를 이용하여 좌표계를 일치시킨다. 이 방법은 정확도가 떨어지지만 부가적인 도구나 수작업이 필요 없으므로 사용성이 좋다. 또한 후처리 기술로 RANSAC을 적용함으로써 오차를 10% 이상 줄였다. 이러한 3가지 방식은 콘텐츠가 필요한 사용 편의성과 정확도에 따라서 선택적으로 적용할 수 있다. 본 연구에서는 이 기술을 이용해서 '썬더펀치'와 재활 치료 콘텐츠에 적용하여 검증하였다.

Wind-induced vibration characteristics and parametric analysis of large hyperbolic cooling towers with different feature sizes

  • Ke, Shitang;Ge, Yaojun;Zhao, Lin;Tamura, Yukio
    • Structural Engineering and Mechanics
    • /
    • 제54권5호
    • /
    • pp.891-908
    • /
    • 2015
  • For a systematic study on wind-induced vibration characteristics of large hyperbolic cooling towers with different feature sizes, the pressure measurement tests are finished on the rigid body models of three representative cooling towers with the height of 155 m, 177 m and 215 m respectively. Combining the refined frequency-domain algorithm of wind-induced responses, the wind-induced average response, resonant response, background response, coupling response and wind vibration coefficients of large cooling towers with different feature sizes are obtained. Based on the calculating results, the parametric analysis on wind-induced vibration of cooling towers is carried out, e.g. the feature sizes, damping ratio and the interference effect of surrounding buildings. The discussion shows that the increase of feature sizes makes wind-induced average response and fluctuating response larger correspondingly, and the proportion of resonant response also gradually increased, but it has little effect on the wind vibration coefficient. The increase of damping ratio makes resonant response and the wind vibration coefficient decreases obviously, which brings about no effect on average response and background response. The interference effect of surrounding buildings makes the fluctuating response and wind vibration coefficient increased significantly, furthermore, the increase ranges of resonant response is greater than background response.

현대패션에 나타난 점프 슈트(Jump Suit)의 조형성과 특성 (A Study on the Plasticity and Characteristics on Jump Suit Shown in the Modern Fashion)

  • 김선영
    • 한국생활과학회지
    • /
    • 제23권3호
    • /
    • pp.515-527
    • /
    • 2014
  • This study is intended to develop the creative and high value-added products as well as the development of diversity for jump suit for the future by analyzing the trend and feature shown in jump suit in the modern fashion. In the research methodology, the analysis was carried out over a total of 351 work pieces on jump suit among those presented in the collection of Paris, Milan, New York and London from 2006S/S to 2013F/W as well as literature review. The aesthetic features on suit jump design introduced in the modern fashion could be characterized as the following. First, both upper and lower garments are composed with a simple array of items and the stress was put on modernity feature through minimal expression technique. The feature of solid simplicity was also given with achromatic color or neutral monochrome. Second, the feminity image was emphasized with adoption of such highlighting items as detailed add-ons, tops, camisoles and blouses that stress the organically curved streamline including silhouette, material itself, crease and drape that enable the direct and indirect exposition of human body and the expression of smooth curve in human body. Third, jump suit revealed the multipurpose feature as item available for the diverse wear such as working habiliment, sports wear, uniform, office wear and evening wear, depending on the terms and conditions. Fourth, the deconstructive characteristic appeared through integration with various items, destruction of formative structure, non-structural shape, and ambiguity in wearing method.

수잔-로리 팍스의 "비너스": 흑인여성의 몸에 나타난 식민주의적 억압과 폭력 (Suzan-Lori Parks' Venus: Colonized oppression and violence in a black woman's body)

  • 박진숙
    • 영어어문교육
    • /
    • 제13권4호
    • /
    • pp.253-270
    • /
    • 2007
  • The purpose of this paper is to illuminate how Suzan-Lori Parks reveals colonized oppression and violence in a black woman's body in Venus. The body of Hottentot Venus is an 'object' of white male spectators' gazes and a dissection from a medical study. The report on her pathologic anatomy gives the audience the illusion that the body of a black woman is inferior to those of others. Not only 'subjective' aesthetics, but also 'objective' medicine makes us confuse 'fact' with 'truth' about black women. By publicly exhibiting her erotic body, Venus is represented as a singular emblem for nineteenth-century colonial discourse on race and sexuality. Her body stands for the powerful signifier of raped Africa. A distinctive feature of black Venus is her raciality. The ownership of her body is only transferred from Mother-Showman to Doctor Baron. She had no right to her ownership. Her body is an object of hatred and curiosity and at the same time a site which is represented by conflicting desires. Parks' eventual goal in Venus is to investigate 'hindsight' of Venus Hottentot, 'the past' and 'the posterior'. As the meaning of original chocolate can be regained, the insulted and damaged body of Venus should also be recovered and resurrected.

  • PDF

구속표면을 가지는 반무한체에 대한 평저펀치의 압입의 연구 (Study of flat punch indentation to semi-infinite body with lpartially constrained free surface by moire method)

  • 김동원
    • 대한기계학회논문집
    • /
    • 제3권4호
    • /
    • pp.164-172
    • /
    • 1979
  • Experimental and numerical results concerning the flat punch indentation to semi-infinite body with partially constrained free surface are presented The distributions of slip line directions are predicted by Moire fringe analysis using Vinckier's method. A mumerical study is made of the same problem by finite element method and the results are compared with the experimental results. It is shown that the contour feature of possible slip line field is similar to that of well-known Prandtl indentation sloution.

3차원 스캔 데이터를 이용하여 임의의 신체 치수에 대응하는 인체 형상 모델 생성 방법 (Synthesis of Human Body Shape for Given Body Sizes using 3D Body Scan Data)

  • 장태호;백승엽;이건우
    • 한국CDE학회논문집
    • /
    • 제14권6호
    • /
    • pp.364-373
    • /
    • 2009
  • In this paper, we suggest the method for constructing parameterized human body model which has any required body sizes from 3D scan data. Because of well developed 3D scan technology, we can get more detailed human body model data which allow to generate precise human model. In this field, there are a lot of research is performed with 3D scan data. But previous researches have some limitations to make human body model. They need too much time to perform hole-filling process or calculate parameterization of model. Even more they missed out verification process. To solve these problems, we used several methods. We first choose proper 125 3D scan data from 5th Korean body size survey of Size Korea according to age, height and weight. We also did post process, feature point setting, RBF interpolation and align, to parameterize human model. Then principal component analysis is adapted to the result of post processed data to obtain dominant shape parameters. These steps allow to reduce process time without loss of accuracy. Finally, we compare these results and statistical data of Size Korea to verify our parameterized human model.

A Study on the Automatic Pattern Development of Adult Male Basic Pattern Using 3D Body Scan Data

  • Jeong, Mi-E;Nam, Yun-Ja
    • 패션비즈니스
    • /
    • 제11권3호
    • /
    • pp.35-45
    • /
    • 2007
  • This study examined how to create 2D basic pattern of individuals by means of 3-D body figure, which is to develop a flat of individual basic pattern directly from the 3-D body scan data of each subject using that of the upper body of a male adult. In terms of methodology, this study adopted 3D body scan data on system and body to make examinations in the following steps: 1. Standard point and line were set on human body, along with 3-D definition points(feature points). 2. PB was created by modifying horizontal and longitudinal section of scan data. 3. Ways to set reserve were established in the findings of PB planar development. Respective developed flat patterns were compared with pattern findings in previous studies by means of sensory evaluation. As a result, it was found that both system and body model are basic pattern and belong to appropriate pattern as semi-tight-fit basic pattern with overall appropriate tolerances. Thus, this study came to a conclusion that it is feasible and valid to develop theories for flat development as considered herein.

가중치를 고려한 자동차 서브프레임의 인증 알고리즘 구현 (Development of Registration Algorithm considering Coordinate Weights for Automobile Sub-Frame Assembly)

  • 이광일;양승한;이영문
    • 한국기계가공학회지
    • /
    • 제3권4호
    • /
    • pp.7-12
    • /
    • 2004
  • Inspection and analysis are essential process to determine whether a completed product is in given specification or not. Analysis of products with very complicated shape is difficult to carry out direct comparison between inspected coordinate and designed coordinates. So process called as matching or registrations is needed to solve this problem. By defining error between two coordinates and minimizing the error, registration is done. Registration consists of translation, rotation and scale transformations. Error must be defined to express feature of inspected product. In this paper, registration algorithm is developed to determine pose of sub-frame at assembly with body of automobile by defining error between two coordinates considering geometric feature of sub-frame.

  • PDF

A Wrist-Type Fall Detector with Statistical Classifier for the Elderly Care

  • Park, Chan-Kyu;Kim, Jae-Hong;Sohn, Joo-Chan;Choi, Ho-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권10호
    • /
    • pp.1751-1768
    • /
    • 2011
  • Falls are one of the most concerned accidents for elderly people and often result in serious physical and psychological consequences. Many researchers have studied fall detection techniques in various domain, however none released to a commercial product satisfying user requirements. We present a systematic modeling and evaluating procedure for best classification performance and then do experiments for comparing the performance of six procedures to get a statistical classifier based wrist-type fall detector to prevent dangerous consequences from falls. Even though the wrist may be the most difficult measurement location on the body to discern a fall event, the proposed feature deduction process and fall classification procedures shows positive results by using data sets of fall and general activity as two classes.