• Title/Summary/Keyword: Blow-down wind tunnel

Search Result 16, Processing Time 0.02 seconds

Starting Characteristics Study of Scramjet Engine Test Facility(SETF) (스크램제트 엔진 시험설비의 시동특성 연구)

  • Lee, Yang-Ji;Kang, Sang-Hun;Oh, Joong-Hwan;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.451-458
    • /
    • 2010
  • Unlike most aerodynamic wind-tunnel, Scramjet Engine Test Facility(SETF) of Korea Aerospace Research Institute should simulate enthalpy condition at a flight condition. SETF is a blow-down type, high-enthalpy wind tunnel. To attain a flight condition, a highly stagnated air comes into the test cell through a supersonic nozzle. Also, an air ejector of the SETF is used for simulating altitude conditions of the engine, and facility starting. SETF has a free-jet type test cell and this free-jet type test cell can simulate a boundary layer effect between an airplane and engine using facility nozzle, but it is too difficult to predict the nature of the facility. Therefore it is required to understand the starting characteristics of the facility by experiments. In this paper, the starting characteristics of the SETF and modifications of the ejector are described.

  • PDF

Study of the Thrust Vector Control using a Secondary Flow Injection (2차 유동 분사에 의한 제트 유동의 추력 제어에 관한 연구)

  • Jung Sung-Jae;Szwaba Ryszard;Kim Heuy-Dong;Ahn Jae-Mun;Jung Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.119-122
    • /
    • 2002
  • In general, Liquid Injection Thrust Vector Control(LITVC) is accomplished by injecting a liquid into the supersonic exhaust flow through holes in the wall of the propulsion nozzle. This injection flow field is highly complicated and detailed flow physics associated with the secondary flow injection should be known far the practical design and use of the LITVC system. The present study aims at understanding the LTTVC flow field and obtaining fundamental design parameters for LITVC. The experimentations were performed in a supersonic blow-down wind tunnel. Compressed, dry air was used for both the main exhaust and injection flows but the pressures of these two flows were controlled independently. The location of the injection holes was changed and the pressures of the two streams were also changed between 2.0 and 15.0 bar. The effectiveness of LITVC was discussed in details using the results of the pressure measurements and flow visualizations

  • PDF

Transitional Behavior of a Supersonic Flow in a Two-dimensional Diffuser

  • Kim, Sehoon;Kim, Hyungjun;Sejin Kwon
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1816-1821
    • /
    • 2001
  • Two-dimensional blow-down type supersonic wind tunnel was designed and built to investigate the transient behavior of the startup of a supersonic flow from rest. The contour of the divergent part of the nozzle was determined by the MOC calculation. The converging part of the nozzle, upstream of fille throat was contoured to make the flow uniform at the throat. The flow characteristics of the steady supersonic condition were visualized using the high-speed schlieren photography. The Mach number was evaluated from the oblique shock wave angle on a sharp wedge with halt angle of 5 degree. The measured Mach number was 2.4 and was slightly less than the value predicted by the design calculation. The initial transient behavior of the nozzle was recorded by a high-speed digital video camera with schlieren technique. The measured transition time from standstill to a steady supersonic flow was estimated by analyzing the serial images. Typical transition time was approximately 0.1sec.

  • PDF

Mach 5 Performance Verification of Free-jet Type Ground Propulsion Test Facility for Scramjet Engine Intake Test (스크램제트 엔진 흡입구 시험을 위한 자유제트형 지상추진시험설비의 마하 5 성능 검증)

  • Lee, Yang Ji;Yang, Inyoung;Lee, Kyung Jae;Oh, Jung Hwan;Choi, Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.1
    • /
    • pp.77-87
    • /
    • 2022
  • In order to perform the scramejt engine intake ground test using the Scramjet Engine Test Facility(SETF) of the Korea Aerospace Research Institute. we introduced the test availability check procedure that is generally conducted. The design process of the newly manufactured Mach 5 nozzle for the scramjet intake test was summarized, a device for checking the core flow distribution of the nozzle was explained, and the core flow test analysis results were written. Through a series of test results, it was confirmed that the intake was located in the new Mach 5 nozzle core.

Heat transfer characteristics around a circular combustion chamber of kerosene fan heater (석유 팬 히터의 연소실 주변 열전달 특성)

  • Kim, Jang-Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.551-561
    • /
    • 1998
  • This paper was studied to understand the characteristics of heat transfer coefficients and surface temperature distributions around a circular combustion chamber within the heat-intercept duct of kerosene fan heater. The experiment was carried out in the heat-intercept duct of kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of 240 mm * 240 mm * 1200 mm. The purpose of this paper was to obtain the basic data related with normal combustion for new design from conventional kerosene fan heater, and to investigate the effect of surface temperature, local and mean heat transfer coefficients versus flow-rate of convection axial fan according to the variations of heat release conditions from kerosene fan heater during normal combustion. Consequently it was found that (i) the revolution of convection axial fan during combustion had a smaller value than that of non-combustion because of the thermal resistance due to the high temperature in the heat-intercept duct, (ii) the pressure ratio P$_{2}$/P$_{1}$ had a comparatively constant value of 0.844 according to the revolution increase of turbo fan and the heating performance of kerosene fan heater had a range of 1,494 ~ 3,852 kcal/hr, (iii) the local heat transfer coefficient around a circular combustion chamber had a comparatively larger scale in the range of 315 deg. < .theta. < 45 deg. than that in the range of 90 deg. < .theta. < 270 deg. as a result of heat transfer difference between front and back of a circular combustion chamber, and (iv) the mean heat transfer coefficient around a circular combustion chamber increased linearly like a H$_{m}$=95.196Q+104.019 in condition of high heat release according to the increase of flow-rate of axial fan.n.

Measurement of Aerodynamic Heating over a Protuberance in Hypersonic Flow of Mach 7 (Mach 7 극초음속 유동 내의 돌출물 공력가열 계측)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Jeung, In-Seuck;Kim, Seong-Lyong;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.6
    • /
    • pp.562-570
    • /
    • 2009
  • An Experimental study was conducted on the flow characteristics and interference heating caused by a two-dimensional object protruding from a flat plate using a blow-down type of hypersonic wind tunnel. Inflow condition was a free-stream Mach number of 7.0 and a unit Reynolds number of $2.0{\times}10^6/m$. Experimental conditions were varied with three heights of protuberance for two flat plate models which have different lengths. Experimental data were obtained from Schlieren visualization images and heat flux measurements. Also, this paper suggests hypersonic experimental techniques such as boundary-layer detection method in detail. A Large separation region was observed in front of the protuberance and that region was very sensitive to the height of protuberance and the length of the flat plate. For only the highest protuberance, a severe jump of heat flux was observed at the top station among the measuring points. Measured heat flux is large when the height of protuberance is large and the length of flat plate is long.