• Title/Summary/Keyword: Blood transfusion

Search Result 405, Processing Time 0.024 seconds

Development of the Standard Blood Inventory Level Decision Rule in Hospitals (병원의 표준 혈액재고량 산출식 개발)

  • Kim, Byoung-Yik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.195-206
    • /
    • 1988
  • Two major issues of the blood bank management are quality assurance and inventory control. Recently, in Korea blood donation has gained popularity increasingly to allow considerable improvement of the quality assurance with respect to blood collection, transportation, storage, component preparation skills and hematological tests. Nevertheless the inventory control, the other issue of blood bank management, has been neglected so far. For the supply of blood by donation barely meets the demand, the blood bank policy on the inventory control has been 'the more the better.' The shortage itself by no means unnecessitate inventory control. In fact, in spite of shortage, no small amount of blood is outdated. The efficient blood inventory control makes it possible to economize the blood usage in the practice of state-of-the-art medical care. For the efficient blood inventory control in Korean hospitals, this tudy is to develop formulae forecasting the standard blood inventory level and suggest a set of policies improving the blood inventory control. For this study informations of $A^+$ whole bloods and packed cells inventory control were collected from a University Hospital and the Central Blood Bank of the Korean Red Cross. Using this informations, 1,461 daily blood inventory records were formulated.48 varieties of blood inventory control environment were identified on the basis of selected combinations of 4 inventory control variables-crossmatch, transfusion, inhospital donation and age of bloods from external supply. In order to decide the optimal blood inventory level for each environment, simulation models were designed to calculate the measures of performance of each environment. After the decision of 48 optimal blood inventory levels, stepwise multiple regression analysis was started where the independent variables were 4 inventory control variables and the dependent variable was optimal inventory level of each environment. Finally the standard blood inventory level decision rule was developed using the backward elimination procedure to select the best regression equation. And the effective alternatives of the issuing policy and crossmatch release period were suggested according to the measures of performance under the condition of the standard blood inventory level. The results of this study' were as follows ; 1. The formulae to calculate the standard blood inventory level($S^*$)was $S^*=2.8617X(d)^{0.9342}$ where d is the mean daily crossmatch(demand) for a blood type. 2. The measures of performace - outdate rate, average period of storage, mean age of transfused bloods, and mean daily available inventory level - were improved after maintenance of the standard inventory level in comparison with the present system. 3. Issuing policy of First In-First Out(FIFO) decreased the outdate rate, while Last In-First Out(LIFO) decreased the mean age of transfused bloods. The decrease of the crossmatch release period reduced the outdate rate and the mean age of transfused bloods.

  • PDF

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

A Successful Transplant of HLA-3 Loci Mismatched Umbilical Cord Blood into a Patient with Acute Myeloid Leukemia from an Unrelated Donor (급성 골수구성 백혈병 환아에서 비혈연간 주조직 적합 항원 3부위 불일치 제대혈 조혈모세포 이식 성공 1례)

  • Kwon, Byoung Chul;Shin, Kyung Mi;Won, Sung Chul;Lyu, Chuhl Joo;Yang, Chang Hyun;Kim, Hyun Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.912-916
    • /
    • 2002
  • Cord blood is a useful source of allogeneic hematopoietic stem cells for bone marrow reconstitution. The number of umbilical cord blood transplants is increasing worldwide. In this a case 15-month-old boy with acute myeloid leukemia was treated with umbilical cord blood transplant from an HLA-3 loci mismatched unrelated donor. Granulocyte recovery greater than $500/mm^3$ occurred at day 49, and the platelet recovered greater than $20,000/mm^3$ independent of transfusion at day 81 after stem cell infusion.

Hemolysis of irradiated leukoreduced red blood cells during rapid warming: An in vitro experimental study

  • Lee, Sukyung;Lee, Sooho;Oh, Jong Eun;Shin, Won-Jung;Min, Won-Ki;Gwak, Mijeung
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.4
    • /
    • pp.229-233
    • /
    • 2015
  • Background: Although water chambers are often used as surrogate blood-warming devices to facilitate rapid warming of red blood cells (RBCs), these cells may be damaged if overheated. Moreover, filtered and irradiated RBCs may be damaged during the warming process, resulting in excessive hemolysis and extracellular potassium release. Methods: Using hand-held syringes, each unit of irradiated and leukocyte-filtered RBCs was rapidly passed through a water chamber set to different temperatures (baseline before blood warming, $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$). The resulting plasma potassium and free hemoglobin levels were then measured. Results: Warming RBCs to $60^{\circ}C$ and $70^{\circ}C$ induced significant increases in free hemoglobin (median [interquartile ranges] = 60.5 mg/dl [34.9-101.4] and 570.2 mg/dl [115.6-2289.7], respectively). Potassium levels after warming to $70^{\circ}C$ ($31.4{\pm}7.6mEq/L$) were significantly higher compared with baseline ($29.7{\pm}7.1mEq/L$; P = 0.029). Potassium levels were significantly correlated with storage duration after warming to $50^{\circ}C$ and $60^{\circ}C$ (r = 0.450 and P = 0.001; r = 0.351 and P = 0.015, respectively). Conclusions: Rapid warming of irradiated leukoreduced RBCs to $50^{\circ}C$ may not further increase the extracellular release of hemoglobin or potassium. However, irradiated leukoreduced RBCs that have been in storage for long periods of time and contain higher levels of potassium should be infused with caution.

Does Additional Aortic Procedure Carry a Higher Risk in Patients Undergoing Aortic Valve Replacement?

  • Kim, Tae-Hun;Park, Kay-Hyun;Yoo, Jae Suk;Lee, Jae Hang;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.295-300
    • /
    • 2012
  • Background: With growing attention to the aortopathy associated with aortic valve diseases, the number of candidates for accompanying ascending aorta and/or root replacement is increasing among the patients who require aortic valve replacement (AVR). However, such procedures have been considered more risky than AVR alone. This study aimed to compare the surgical outcome of isolated AVR and AVR combined with aortic procedures. Materials and Methods: A total of 86 patients who underwent elective AVR between 2004 and June 2010 were divided into two groups: complex AVR (n=50, AVR with ascending aorta replacement in 24 and the Bentall procedure in 26) and simple AVR (n=36). Preoperative characteristics, surgical data, intra- and postoperative allogenic blood transfusion requirement, the postoperative clinical course, and major complications were retrospectively reviewed and compared. Results: The preoperative mean logistic European System for Cardiac Operative Risk Evaluation (%) did not differ between the groups: $11.0{\pm}7.8%$ in the complex AVR group and $12.3{\pm}8.0%$ in the simple AVR group. Although complex AVR required longer cardiopulmonary bypass ($152.4{\pm}52.6$ minutes vs. $109.7{\pm}22.7$ minutes, p=0.001), the quantity of allogenic blood products did not differ ($13.4{\pm}14.7$ units vs. $13.9{\pm}11.2$ units). There was no mortality, mechanical circulatory support, stroke, or renal failure requiring hemodialysis/filtration. No difference was found in the incidence of bleeding (40% vs. 33.3%) which was defined as red blood cell transfusion ${\geq}5$ units, reoperation, or intentional delayed closure. The incidence of mediastinitis (2.0% vs. 0%), ventilator ${\geq}24$ hours (4.0% vs. 2.8%), atrial fibrillation (18.0% vs. 25.0%), mean intensive care unit stay (34.5 hours vs. 38.8 hours), and median hospital stay (8 days vs. 7 days) did not differ, either. Conclusion: AVR combined with additional aortic or root replacement showed an excellent outcome and recovery course equivalent to that after isolated AVR.

Detection of Anti-Lua in an Unexpected Antibody Screening Test: A Case Report and Literature Review (비예기항체 선별검사에서 항-Lua의 검출: 증례보고 및 문헌고찰)

  • Song, Sae Am;Oh, Seung Hwan;Park, Tae Sung;Son, Hye Soo;Sung, Sung Kyung;Lee, Ja Young;Jun, Kyung Ran;Shin, Jeong Hwan;Kim, Hye Ran;Lee, Jeong Nyeo
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.169-172
    • /
    • 2012
  • Lutheran a antigen ($Lu^a$) is detected in 6 to 8% of Caucasians and Africans. In Korean and other Asian populations, it is very rare or nearly absent. Therefore, although $Lu^a$ has a considerable immunizing capacity, sensitization to $Lu^a$ is a rare event. Here we report on a rare case of anti-$Lu^a$ in a 70 year-old female patient with Lu (a-/b+) phenotype and review the relevant literature. Due to the paucity of $Lu^a$ positive panel cells in antibody screening and identification tests, detection of this rare antibody to $Lu^a$ antigen is not feasible. Therefore, we should keep in mind the possibility of the misleading false negative result in detection of antibody to this low incidence antigen.

Development of HLA-A, -B and -DR Typing Method Using Next-Generation Sequencing (차세대염기서열분석법을 이용한 HLA-A, -B 그리고 -DR 형별 분석법 개발)

  • Seo, Dong Hee;Lee, Jeong Min;Park, Mi Ok;Lee, Hyun Ju;Moon, Seo Yoon;Oh, Mijin;Kim, So Young;Lee, Sang-Heon;Hyeong, Ki-Eun;Hu, Hae-Jin;Cho, Dae-Yeon
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.310-319
    • /
    • 2018
  • Background: Research on next-generation sequencing (NGS)-based HLA typing is active. To resolve the phase ambiguity and long turn-around-time of conventional high resolution HLA typing, this study developed a NGS-based high resolution HLA typing method that can handle large-scale samples within an efficient testing time. Methods: For HLA NGS, the condition of nucleic acid extraction, library construction, PCR mechanism, and HLA typing with bioinformatics were developed. To confirm the accuracy of the NGS-based HLA typing method, the results of 192 samples HLA typed by SSOP and 28 samples typed by SBT compared to NGS-based HLA-A, -B and -DR typing. Results: DNA library construction through two-step PCR, NGS sequencing with MiSeq (Illumina Inc., San Diego, USA), and the data analysis platform were established. NGS-based HLA typing results were compatible with known HLA types from 220 blood samples. Conclusion: The NSG-based HLA typing method could handle large volume samples with high-throughput. Therefore, it would be useful for HLA typing of bone marrow donation volunteers.

Direct Open Venous Drainage: An Alternative Choice for Flap Congestion Salvage

  • Park, Su Han;Choi, Woo Young;Son, Kyung Min;Cheon, Ji Seon;Yang, Jeong Yeol
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.143-146
    • /
    • 2015
  • In this report, we present a scalp defect reconstruction with lateral arm free flap. We highlight the difficulty in obtaining a recipient vein and the venous drainage managed through an open end of the donor vein. A 52-year-old woman presented with a pressure sore on the left scalp. A lateral arm free flap was transferred to cover this $8{\times}6cm$ defect. The arterial anastomosis was successful, but no recipient vein could be identified within the wound bed. Instead, we used a donor venous end for the direct open venous drainage. In order to keep this exposed venous end patent, we applied heparin-soaked gauze dressing to the wound. Also, the vein end was mechanically dilated and irrigated with heparin solution at two hour intervals. Along with fluid management and blood transfusion, this management was continued for the five days after the operation. The flap survived well without any complication. Through this case, we were able to demonstrate that venous congestion can be avoided by drainage of the venous blood through an open vessel without the use of leeches.

Early Clinical Result of Coronary Artery Bypass Surgery for Ischemic Heart Diaseas (허혈성심장질환의 치료에서 관상동맥 우회술의 조기성적;53례의 임상적 결과)

  • 최종범
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.271-275
    • /
    • 1993
  • In this country, the number of patients with coronary artery disease is progressively increasing with the change of life style and improvement of the diagnostic procedures. In addition, the medically invasive procedure for treating ischemic heart disease was rapidly developed and the surgical patients have more complex and multiple lesions and more surgical risks. Fifty three patients with ischemic heart disease underwent coronary bypass grafting [CABG] for recent 24 months. Twenty patients had three-vessel disease, 17 patients two-vessel disease, and 2 patients single-vessel disease. The average number of distal anastomoses was 3.3 per patient with the range of I to 6 grafts. Forty-one patients [77.4 %] had preoperative left ventricular ejection fraction of 50 % or more and 14 patients[26.4%] had a significant left main coronary lesion. Saphenous vein grafts were employed in 52/53 patients [98.1%] and internal mammary grafts, which were anastomosed to left anterior descending artery, in 38/53 patients[71.7%]. Two patients, whom percutaneous transluminal coronary angioplasty failed for, underwent emergency CABG with only saphenous vein grafts and both patients survived.The hospital mortality was 1.9 % and there was no late death. Perioperative myocardial infarction occurred in 1.9%. All survivors were asymptomatic[in 83% of the patients] and/or improved over their preoperative status. Twenty-nine patients were included in blood conservation group and 21 patients [72.4 %] underwent CABG without any homologous blood transfusion. Our early result of coronary bypass grafting was comparable to that which was reported in other coronary surgery units.

  • PDF

Alveolar rhabdomyosarcoma with massive disseminated intravascular coagulopathy treated with systemic chemotherapy

  • Yoon, Byung Gyu;Baek, Hee Jo;Oh, Burm Seok;Han, Dong Kyun;Choi, Yoo Duk;Kook, Hoon
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.12
    • /
    • pp.505-508
    • /
    • 2015
  • It is uncommon for pediatric patients with rhabdomyosarcoma to present with clinical and/or laboratory features of disseminated intravascular coagulation (DIC). We report a case of metastatic alveolar rhabdomyosarcoma with severe bleeding because of DIC in a 13-year-old boy. He experienced persistent oozing at the site of a previous operation, gross hematuria, and massive epistaxis. Two weeks after initiating combination chemotherapy consisting of vincristine, doxorubicin, and cyclophosphamide, the patients' laboratory indications of DIC began to resolve. During this period, the patient received massive blood transfusion of a total of 311 units (26 units of red blood cells, 26 units of fresh frozen plasma, 74 units of platelet concentrates, 17 units of single donor platelets, and 168 units of cryoprecipitate), antithrombin-III and a synthetic protease inhibitor. Despite chemotherapy and radiation therapy, he died 1 year later because of disease progression. In children with metastatic rhabdomyosarcoma and massive DIC, prompt chemotherapy and aggressive supportive care is important to decrease malignancy-triggered procoagulant activities.