• Title/Summary/Keyword: Blood pressure measurement system

Search Result 100, Processing Time 0.025 seconds

Development of u-Healthcare Agent System using of 3-Axis Accelerometer Sensor (3축 가속도 센서를 이용한 u-헬스케어 에이전트 시스템 개발)

  • Choi, Dong-Oun;Kim, Jin-Sung;Song, Haeng-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.4
    • /
    • pp.98-105
    • /
    • 2010
  • Health of the people involved in blood sugar, blood pressure, activity, and using bio-sensors to obtain biometric information, the system for monitoring health research for development is a lot. This paper analyzes the bio information by monitoring the u-health care agent system was developed. Activity measurement technology that uses 3-axis accelerometer sensor. 3-axis acceleration sensors, using information obtained from activity to activity analysis to calculate the exact algorithm was developed. More accurate than the existing system to calculate the calorie consumption, it is stored in the database management. and you can check your health status using of activity and bio-information.

Design of A Downlink Power Control Scheme in Unequal Error Protection Multi-Code CDMA Mobile Medicine System

  • Lin, Chin-Feng;Lee, Hsin-Wang;Hung, Shih-Ii;Li, Ching-Yi
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.335-338
    • /
    • 2005
  • In this paper, we propose a downlink power control scheme to apply in the unequal error protection multi-code CDMA mobile medicine system. The mobile medicine system contains (i) blood pressure and body temperature measurement value, (ii) ECG medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal, MPEG-4 CCD sensor video signal, and JPEG2000 medical image. By the help of the multi-code CDMA spread spectrum communication system with downlink power control scheme and unequal error protection strategy, it is possible to transmit mobile medicine media and meet the quality of service. Numerical analysis and simulation results show that the system is a well transmission platform in mobile medicine.

  • PDF

A Study of Medicinal Plants for Applications in Functional Foods 1. Effects of Schizandrae fructus on the Regional Cerebral Blood Flow and Blood Pressure in Rats (기능성 식품으로의 활용을 위한 한약자원에 관한 연구 1. 오미자 열수추출물이 흰쥐의 국소 뇌혈류량과 혈압에 미치는 영향)

  • 박성혜;한종현
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.1
    • /
    • pp.34-40
    • /
    • 2004
  • The purpose of this study was to measure the changes of regional cerebral blood flow (rCBF) and blood pressure (BP) in rats, following the intravenous injection of Schizandrae fructus water extract. The measurement was continually monitored by laser-doppler flowmeter and pressure tranducer in anesthetized adult Sprague-Dawley rats for 2 hours to 2 hours and a half through the data acquisition system composed of MacLab and Macintosh computer. The result of this experiment was as followed. Schizandrae fructus increased the changes of rCBF in rats significantly. The rCBF of Schizandrae fructus did not change by pretreated propranolol, atropine, L-NNA and indomethacin. But the rCBF of Schizandrae fructus was increased by pretreated methylene blue. Schizandrae fructus decreased the changes of BP, significantly. The BP of Schizandrae fructus did not change by pretreated propranolol, atropine, L-NNA and indomethacin. But the BP of Schizandrae fructus was decreased by pretreated methylene blue. There results indicated that Schizandrae fructus can increase the rCBF and decrease the BP, that is related to guanylyl cyclase activity.

Long-term measurement of physiological cardiovascular parameters using telemetry system in dosgs.

  • Kim, Eun-Joo;Seo, Joung-Wook;Choi, Gyu-Kap;Park, Eun-Kyung;Kim, Ki-Suk;Shin, Won-Ho;Han, Sang-Seop
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.87.1-87.1
    • /
    • 2003
  • With the issuance of the ICH “Guidance for industry S7A Safety Pharmacology Studies For Human Pharmaceuticals” in July 2001 came the preference for the use of unanesthetized animals when evaluation the safety profile of new pharmaceutical agents. Telemetry provides a means of obtaining measurements of physiological functions in conscious animals without the problems associated with classical cardiovascular measuring methods. The Korea Institute of Toxicology (KIT) established the telemetric measurement of cardiovascular parameters, such as Blood pressure, Heart rate, ECG (PR, RR, QRS, QT and QTcB interval) under GLP conditions. (omitted)

  • PDF

Biological Signal Measurements in SiMACS (SiMACS에서의 생체신호 수집)

  • Lim, J.J.;Choi, Y.S.;Kim, D.H.;Kim, E.J.;Lee, H.J.;Woo, E.J.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.53-56
    • /
    • 1994
  • We have developed biological signal measurement modules and data acquisition and control card for a biological signal measurement, archiving, and communication system (SiMACS). Biological signals included in this system are ECG, EEG, EMG, invasive blood pressure, respiration, and temperature. Parameters of each module can be controlled by PC-base IDPU (intelligent data processing unit) through a data acquisition and control card. The data acquisition and control card can collect up to 16 channels of biological signals with sampling rate of $50\;{\sim}\;2,000Hz$ and 12-bit resolution. All measurement moduls and data acquisition functions are controlled by microcontroller which receives commands from PC. All data transfers among PC, microcontroller, and ADC are done through a shared RAM access by polling method for real rime operation.

  • PDF

A Simulation Study of Impedance Plethysmography for Diagnosing Deep Vein Thrombosis (Deep Vein Thrombosis 진단을 위한 Impedance Plethysmography의 시뮬레이션 연구)

  • Lee, Jeon;Lee, Kyoung-Joung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.10
    • /
    • pp.494-501
    • /
    • 2001
  • In this study, the effects of vascular parameter changes and electrodes on VOP measurement based on IPG were simulated mathematically. For the evaluation of the effects of hemodynamic changes on VOP, a mathematical model, which consists of cardiovascular system model and venous occlusion model, was developed and the model solution representing the blood flow and pressure in measuring point was found by 2nd order Runge-Kutta method. And, with sensitivity coefficients obtained from finite element solution of electric field in measuring point, the effects of electrode system on measurement were evaluated. As increasing the resistance, the venous capacitance was not changed but the venous outflows were decreased and the decreased compliance reduced the venous capacitance. And, for several configurations of round electrodes and band electrodes, the sensitivity coefficients were computed using the electric field distribution along deep vein. In conclusion, the proposed mathematical cardiovascular model could be applied to the simulation study on the effects of hemodynamic parameters on DVT diagnosis with IPG. And, also the sensitivity coefficients could provide effective electrode configuration for exact measurement of VOP.

  • PDF

Evaluation of Significance & Development of Quantitative Measurement System for Acupoint Pigmentation by Cupping Therapy (부항요법에 의한 배수혈 혈색소 변화의 정량적 측정 시스템 개발 및 유의성 평가)

  • Kim, Soo-Byeong;Lee, Na-Ra;Jung, Byung-Jo;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • Objectives : The aim of this study is to develop the system and evaluate the optical analytical technique that reflects acupoint pigmentation and extravasated blood by cupping. Methods : We designed the system able to express XYZ coordinate on local skin color. To evaluate measurement-accuracy, we compared with 24 Color Checker Chart by standardized Commission Internationale de l'Eclairage. After confirming the performance of system, we experimented with cupping which was 80 kPa negative pressure for 1 minute on left/right BL13. The X, Y and Z values were converted to R, G and B, $L^*$, $a^*$ and $b^*$, Erythema Index (E.I.), and Melanin Index (M.I). We compared and analyzed two cases on before/after cupping. Results : The R, G and B values which were converted by X, Y and Z values had high linearity as a high level of R-square (R: 0.969, G: 0.996, and B: 0.992). Moreover, we confirmed that it was possible to quantitatively analyzed the change in skin color by cupping using R, G, B, $L^*$, $a^*$, $b^*$, E.I., and M.I. Conclusions : Therefore, we proposed the new analytical technique for objectifying the oriental medical diagnostic method using cupping and optical sensing technique.

Atrial Natriuretic Peptide Attenuates the Development of Hypertension in 2-Kidney, 1-Clip Goldblatt Rats (2-Kidney, 1-Clip Goldblatt 흰쥐에 있어서 고혈압 발생에 미치는 Atrial Natriuretic Peptide 의 영향)

  • Lee, Jong-Eun
    • The Korean Journal of Physiology
    • /
    • v.23 no.1
    • /
    • pp.43-49
    • /
    • 1989
  • Effects of atrial natriuretic peptide (ANP) on the development of hypertension in 2-kidney, 1-clip (2-K, 1-C) rats were examined. In one group of rats, ANP infusion (500 ng/hr, iv) started immediately after clipping the renal artery. Another group of rats with one kidney-clipped was without ANP infusion and served as a control. Blood pressure was measured on days 4, 7, and 10 following clipping the renal artery. Upon the last blood pressure measurement finished, blood sample was collected by decapitation to measure plasma renin activity (PRA), and both kidneys were taken to weigh and to measure renin content. The ANP-infused group showed an attenuation of increases in blood pressure compared to the non-infused control group. PRA was lower in the ANP-infused group than in the non-infused group. Cortical renal renin content (RRC) of the clipped kidneys was not different between ANP-infused and non-infused groups. The clipped kidneys showed a higher RRC and weighed less than the non-clipped contralateral kidneys within each group. In contrast, sham-clipped rats did not show significant changes in any of the parameters examined regardless of whether ANP was infused or not. These results demonstrate that chronic ANP infusion does not prevent but does attenuate the development of hypertension in 2-K, 1-C rats. It is suggested that ANP plays a role in the long-term regulation of blood pressure, at least in part, by antagonizing the renin-angiotensin-system.

  • PDF

Algorithm for reduction of motion artifact generated in SpO2 measurement (산소포화도(SpO2) 측정시에 발생되는 motion artifact를 reduction하는 algorithm)

  • 한승헌;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.860-863
    • /
    • 2003
  • Pulse oximetry has gained wide spread clinical acceptance in the latter part of the 21st century. The principle of pulse oximetry is based on the red and infrared light absorption features and uses a light emitter with red and infrared LEDs that shines through a reasonably translucent site with good blood flow. There are two methods of sending light through the measuring site : transmission and reflectance. After the transmitted red and infrared signals pass through the measuring site and received at the photodetector, the red/infrared ratio is calculated. But, pulse of oximeters are so sensitive that they may detect pulses when pressure is too low to provide adequate tissue blood flow, that is, SpO2 may decrease due to O2 consumption by the finger of the pulsing but stagnant arterial blood at low pressure or with vasoconstriction. This project has the limitations of pulse oximetry. Therefore, this paper is focused on the resuction of motion artifact that caused by moving when someone measures with SpO2 system.

  • PDF

Effects of bee venom acupuncture on heart rate variability, pulse wave, and cerebral blood flow for types of Sasang Constitution (봉약침 자극이 사상체질별 건강인의 심박변이도, 맥파, 뇌혈류에 미치는 영향)

  • Lee, Sang-Min;Kim, Koo;Oh, Seung-Yun;Kwon, Young-Mi;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • 1. Objectives To evaluate effects of bee venom acupuncture on cardiovascular system and differences according to each constitution. 2. Methods Heart rate variability, pulse wave and the velocity of cerebral blood flow were measured before bee venom acupuncture(BVA), right after and after 30 minuets, had been applied to 20 subjects. 3. Results 1. BVA did not have effects on measurement variables of heart rate variability. 2. BVA had effects on pulse wave, showing total time, radial augmentation index up and height of percussion wave, time to percussion wave, sum of pulse pressure down. 3. BVA did not have effects on the cerebral blood flow velocity when considering not Sasang Constitution. 4. Considering Sasang Constitution, BVA demonstrates different responses in time to preincisura wave, mean blood flow velocity, peak systolic velocity and end diastolic velocity. 4.Conclusion From those results, the following conclusions are obtained. Cause BVA alters pulse wave and makes differences in the cerebral blood flow velocity according to Sasang Constitution. Various methods of BVA treatment are needed considering Sasang Constitution.