• Title/Summary/Keyword: Blood Simple

Search Result 509, Processing Time 0.024 seconds

Needs Assessment for Web-based Self-management Program by the Nutrition Knowledge Levels of Diabetic Patients (당뇨환자의 영양지식수준에 따른 자가관리 현황 및 웹베이스 영양관리 프로그램 개발에 관한 요구도 조사)

  • Ahn, Yun;Bae, Jea-Hurn;Youn, Jung-Eun;Kim, Hee-Seon
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.1
    • /
    • pp.155-168
    • /
    • 2011
  • This study was conducted to assess needs of self-management nutrition program for diabetic patients. The survey was conducted among 100 diabetic patients, and the mean age of the subjects was 54.2 years old. Thirty three percent of the subjects were diagnosed diabetes less than 2 years ago. The average nutrition knowledge score about diabetes was 10.2 point, and percentages of correct answers were very high in 'foods rich in fiber' (97.0%), 'relevance of exercise and insulin' (97.0%), 'quantity of insulin injection' (91.0%), and 'diabetes menu' (91.0%). The sources of nutrition information were hospitals/healthcare centers (56.1%), TV/radio (19.2%), and internet (13.1%). Sixty nine percent of the subjects have experienced nutrition education on subjects as 'menu planning skills'(22.4%), 'selecting foods' (22.4%), 'relevance of blood glucose and eating foods' (21.5%) by personal counseling (54.4%). The total score of eating behavior was higher after diagnosed diabetes (35.3) than before (30.0) (p < 0.001). The preferred topics in developing diabetes nutrition information websites were 'diabetes mellitus', 'relevance of blood glucose and foods', and 'selecting foods for diabetes'. The subjects wanted the websites developed by 'using mainly illustrations, pictures, tables' (22.8%) and 'using simple design' (19.6%). The preferred contents in developing diabetes self-management nutrition program were 'dietary life diagnosis', 'chronic disease risk diagnosis', 'calorie control by selecting foods and cooking skills', and 'dietary assessment'. In designing the program, the subjects' most wanted designs were 'be handy and simple in using' (29.3%), 'using simple design' (17.9%), and 'using mainly illustrations, pictures, tables' (15.7%).

Successful Removal of Endobronchial Blood Clots Using Bronchoscopic Cryotherapy at Bedside in the Intensive Care Unit

  • Lee, Hongyeul;Leem, Cho Sun;Lee, Jae Ho;Lee, Choon-Taek;Cho, Young-Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.77 no.4
    • /
    • pp.193-196
    • /
    • 2014
  • Acute airway obstruction after hemoptysis occurs due to the presence of blood clots. These conditions may result in lifethreatening ventilation impairment. We report a case of obstruction of the large airway by endobronchial blood clots which were removed using bronchoscopic cryotherapy at the bedside of intensive care unit. A 66-year-old female with endometrial cancer who had undergone chemotherapy, was admitted to the intensive care unit due to neutropenic fever. During mechanical ventilation, the minute ventilation dropped to inadequately low levels and chest radiography showed complete opacification of the left hemithorax. Flexible bronchoscopy revealed large blood clots obstructing the proximal left main bronchus. After unsuccessful attempts to remove the clots with bronchial lavage and forceps extraction, blood clots were removed using bronchoscopic cryotherapy. This report shows that cryotherapy via flexible bronchoscopy at the bedside in the intensive of intensive care unit is a simple and effective alternative for the removal of endobronchial blood clots.

Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements (실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.

A Study on the Significance of the Colloidal Radiogold Disappearance Rate as a Simple Clinical Liver Function Test (임상간기능검사법(臨床肝機能檢査法)으로서의 교질형방사성금(膠質形放射性金)의 혈중소실율(血中消失率)의 의의(意義)에 관(關)한 연구(硏究))

  • Hong, Chang-Gi
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 1969
  • Liver functions in diffuse parenchymal liver disease such as cirrhosis of the liver depend largely on the effective hepatic blood flow rather than on the individual cell functions. Clinical methods of measuring the hepatic blood flow were developed recently by the application of colloidal disappearance rate. In order to correlate the radiogold disappearance rate to conventional biochemical liver function tests, 21 normal subjects and 80 cases of cirrhosis of the liver were studied with both methods. The results are summarized as following: 1. The validity of external counting method to measure the blood disappearance rate of colloidal radiogold was confirmed by in vitro counting of the serial blood samples. 2. The blood disappearance rate of collidal radiogold was essentially the same. as the liver uptake rate of colloidal radiogold in normal and cirrhotic subjects with various degrees of functional disturbance. And it seemed there was no serious extrahepatic removal of the colloidal radiogold. 3. The disappearance rate of colloidal radiogold was not significantly changed by the posture change, but was enhanced by ingestion of 500 ml of water. 4. The disappearance rate of colloidal radiogold was not influenced by single dose of Telepaque, while BSP retention was increased after Telepaque. 5. The mean disappearance half time of colloidal radiogold in normal subjects was $2.49{\pm}0.391$(S.D.) minutes. The mean normal disappearance rate constant (K value) was $0.285{\pm}0.0428$(S.D.)/minute. 6. The colloidal radiogold disappearance half time was abnormally prolonged (over 3.2 min.) in $87.7{\pm}3.68$(S.D.) % of cirrhotic subjects. 7. In patients of liver cirrhosis the blood disappearance rate of colloidal radiogold correlated well to serum albumin and globulin levels and BSP retention which were considered to reflect functions of hepatic parenchymal cells. There was, however, no correlation between colloidal disappearance rate and thymol turbidity test, serum glutamic pyruvic transaminase, and serm alkaline phosphatase activities. The latters were considered to be associated with the activity of liver disease.

  • PDF

Single use Automatic Lancet to Minimize Pain During Skin Puncture (피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구)

  • 김현식;김경아;전명희;김태임;정용현;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.323-327
    • /
    • 2002
  • Chronic diabetic patients need to sample capillary blood for monitoring and controlling the blood sugar level. Frequent sampling requires to minimize pain during skin puncture. The present study developed mechanisms to minimize pain with effective sampling procedure. which consisted of tapered spring, guiding tunnel, and 30G needle Penetration depth was limited to within 2mm for pain reduction as well as for safety. Simple no-reuse mechanism also prevented the cross-patient and secondary infection possibility. Clinical experiments demonstrated the best convenience and safety with minimal pain in the diabetes, normal, and nursing students groups. Sing1e blood sampling was enough for successful blood sugar test by portable analyzer. The present sing1e use auto-lancet should be of great convenience in frequent capillary blood sampling for the diabetes.

Association between oxidative stress and blood pressure in Korean subclinical hypertensive patients (경계성 고혈압 환자에서 혈압과 산화 스트레스 관련 지표 간의 상관성에 관한 연구)

  • Han, Jeong-Hwa;Lee, Hye-Jin;Choi, Hee Jeong;Yun, Kyung Eun;Kang, Myung-Hee
    • Journal of Nutrition and Health
    • /
    • v.46 no.2
    • /
    • pp.126-136
    • /
    • 2013
  • This study was conducted in order to investigate the association between hypertension and oxidative stress-related parameters and to evaluate these parameters in subclinical hypertensive patients and normotensive subjects living in Korea. We attempted to determine whether oxidative stress-related parameters would differ between two groups of 227 newly-diagnosed, untreated (systolic blood pressure (BP) ${\geq}$ 130 mmHg and diastolic BP ${\geq}$ 85 mmHg) and 130 normotensive subjects (systolic BP < 120 mmHg and diastolic BP < 80 mmHg). General characteristics of the subjects were collected using a simple questionnaire. From subjects' blood, degree of DNA damage in lymphocytes, the activities of erythrocyte superoxide dismutase, catalase, and glutathione peroxidase, level of plasma total radical-trapping antioxidant potential (TRAP), glutathione, and anti-oxidative vitamins, as well as plasma lipid profiles and conjugated diene (CD) were analyzed. Evaluation of the associations of oxidative stress-related parameters with blood pressure of the subjects was performed using Pearson partial correlation and multivariate logistic regression analysis after adjusting for confounding factors. Several oxidative stress-related parameters were higher in subclinical hypertensive patients than in normotensive subjects. Plasma levels of ${\alpha}$-tocopherol, ${\beta}$-carotene, TRAP, and activity of GSH-px were significantly lower in subclinical hypertensive patients than in normotensive subjects. Increased levels of DNA damage, lipid peroxidation, triglyceride, total cholesterol, and LDL-cholesterol were observed in subclinical hypertensive patients. These results confirm an association between blood pressure and oxidative stress-related parameters and suggest that the pathogenic role of oxidative stress in hypertension might be significant.

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

A standardized method to study immune responses using porcine whole blood

  • Sameer-ul-Salam Mattoo;Ram Prasad Aganja;Seung-Chai Kim;Chang-Gi Jeong;Salik Nazki;Amina Khatun;Won-Il Kim;Sang-Myeong Lee
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.11.1-11.14
    • /
    • 2023
  • Background: Peripheral blood mononuclear cells (PBMCs) are commonly used to assess in vitro immune responses. However, PBMC isolation is a time-consuming procedure, introduces technical variability, and requires a relatively large volume of blood. By contrast, whole blood assay (WBA) is faster, cheaper, maintains more physiological conditions, and requires less sample volume, laboratory training, and equipment. Objectives: Herein, this study aimed to develop a porcine WBA for in vitro evaluation of immune responses. Methods: Heparinized whole blood (WB) was diluted (non-diluted, 1/2, 1/8, and 1/16) in RPMI-1640 media, followed by phorbol myristate acetate and ionomycin. After 24 h, cells were stained for interferon (IFN)-γ secreting T-cells followed by flow cytometry, and the supernatant was analyzed for tumor necrosis factor (TNF)-α. In addition, diluted WB was stimulated by lipopolysaccharide (LPS) and polyinosinic:polycytidylic acid (poly I:C), reference strain KCTC3557 (RS), field isolate (FI), of heat-killed (HK) Streptococcus suis, and porcine reproductive and respiratory syndrome virus (PRRSV). Results: The frequency of IFN-γ+CD3+ T-cells and concentration of TNF-α in the supernatant of WB increased with increasing dilution factor and were optimal at 1/8. WB TNF-α and interleukin (IL)-10 cytokine levels increased significantly following stimulation with LPS or poly I:C. Further, FI and RS induced IL-10 production in WB. Additionally, PRRSV strains increased the frequency of IFN-γ+ CD4-CD8+ cells, and IFN-γ was non-significantly induced in the supernatant of re-stimulated samples. Conclusions: We propose that the WBA is a rapid, reliable, and simple method to evaluate immune responses and WB should be diluted to trigger immune cells.

A Simple and Rapid Gene Amplification from Arabidopsis Leaves Using AnyDirect System

  • Yang, Young-Geun;Kim, Jong-Yeol;Soh, Moon-Soo;Kim, Doo-Sik
    • BMB Reports
    • /
    • v.40 no.3
    • /
    • pp.444-447
    • /
    • 2007
  • Polymerase chain reaction (PCR) is a powerful technique in molecular biology and is widely used in various fields. By amplifying DNA fragments, PCR has facilitated gene cloning procedures, as well as molecular genotyping. However, the extraction of DNA from samples often acts as a limiting step of these reactions. In particular, the extraction of PCR-compatible genomic DNA from higher plants requires complicated processes and tedious work because plant cells have rigid cell walls and contain various endogenous PCR inhibitors, including polyphenolic compounds. We recently developed a novel solution, referred to as AnyDirect, which can amplify target DNA fragments directly from whole blood without the need for DNA extraction. Here, we developed a simple lysis system that could produce an appropriate template for direct PCR with AnyDirect PCR buffer, making possible the direct amplification of DNA fragments from plant leaves. Thus, our experimental procedure provides a simple, convenient, non-hazardous, inexpensive, and rapid process for the amplification of DNA from plant tissue.

A Study on the Estimation of Regional Myocardial Blood Flow in Experimental Canine Model with Coronary Thrombosis using Rb-82 Dynamic Myocardial Positron Emission Tomography (실험 개에서 Rb-82 심근 Dynamic PET 영상을 이용한 국소 심근 혈류 예측의 기본 모델 연구)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Keon-Wook;Hwang, Eun-Kyung;Jeong, Jae-Min;Chang, Kee-Hyun;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.48-53
    • /
    • 1995
  • This study investigates a simple mathematical model for the quantitative estimation of regional myocardial blood flow in experimental canine coronary artery thrombosis using Rb-82 dynamic myocardial positron emission tomography. The coronary thrombosis was induced using the new catheter technique by narrowing the lumen of coronary vessel gradually, which finally led to partial obstruction of coronary artery. Ten Rb-82 dynamic myocardial PET scans were performed sequentially for each experiment using our 5, 10 and 20 second acquisition protocol, respectively, and three regions of interest were drawn on the transaxial slices, one on left ventricular chamber for input function and the other two on normal and decreased perfusion segments for the flow estimation in those regions. Single compartment model has been applied to the measured sets of regional PET data, and the rate constants of influx to myocardial tissue were calculated for regional myocardial flow estimates with the three parameter fits of raw data by the Levenberg-Marquardt method. The results showed that, (1) single compartment model suggested by Kety-Schmidt could be used for the simple estimation of regional myocardial blood flow, (2) the calculated regional myocardial blood flow estimates were dependent on the selection of input function, which reflected partial volume effect and left ventricular wall motion, and (3) mathematically fitted input and tissue time activity curves were more suitable than the direct application of the measured data in terms of convergence.

  • PDF