Park, Hye-Jeong;Jeon, Tae-Eun;Kim, Yong-Seob;Jin, Hyun-Soek;Park, Sangjung
Biomedical Science Letters
/
v.26
no.1
/
pp.28-36
/
2020
High blood pressure (HTN) is a condition in which blood pressure is kept higher than normal. Blood pressure trait measures systolic blood pressure (SBP) which is the highest pressure and diastolic blood pressure (DBP) which is the lowest blood pressure. Pulse pressure (PP) is the difference between systolic and diastolic blood pressure. Hypertension is known as a disease caused by the interaction of the environment and genetic factors. To date, studies have been conducted to find genes associated with hypertension. Genome-Wide Association Study (GWAS) analysis using European data from the UK Biobank reported new 535 loci were associated with blood pressure trait. Among them, 12 genes have been reported to have a significant correlation with SBP, DBP and PP. In the study, 12 genes polymorphisms were extracted based on KARE (Korean association resource) and then we performed linear regression of blood pressure trait. As a result, 6 SNPs of the 3 genes (rs12355413 and rs11006736 of ARMC4, rs2290883, rs2290884 and rs11039014 of LRP4, rs7234941 of BCL2) showed statistically significant correlation (P<0.05) with blood pressure trait. Of the 3 genes, 6 SNPs in 2 genes (rs9651357, rs12355413, rs11006736, rs1889522 of ARMC4 and rs4987774, rs7234941 of BCL2) showed significant correlation with hypertension. These results suggest that genetic polymorphisms of ARMC4, LRP4 and BCL2 genes are associated with blood pressure traits and hypertension in Korean population. Moreover, we expected to help understand the pathogenesis of hypertension.
The literature suggested that a small reduction in overall blood pressure can have a large effect on overall prevalence of hypertension, and therefore, the affect of taste preferences of the population on salt intake should be considered for long-term blood pressure intervention programs. The purpose of this study is to investigate the influence of salt taste preference and salt taste sensitivity on salt intake behavior as risk factors for high blood pressure. We collected information on blood pressure, diet and lifestyle behaviors, salt taste preference and salt taste sensitivity from 540 respondents from Suseo-dong, Seoul. Salt taste sensitivity was assessed by administering a 1% NaCl solution to the subject's tongue and measuring the perceived intensity on 10 level scale. Salt intake behavior was classified into 3 categories: frequency of high-sodium foods, practice of salt-reducing behavior and frequency of vegetable and fruit intake. Salt taste preference showed a significant relation to the subjects' blood pressure, i.e. subjects with a higher salt preference had higher blood pressure. Salt taste sensitivity did not show a significant relation to blood pressure. However, there was a positive correlation between salt taste preference and salt taste sensitivity. Among the 3 indicators used to measure salt intake behavior, the practice of salt-reducing behavior remained significantly correlated to blood pressure. Moreover, salt-reducing behavior and salt taste preference showed a significant correlation, i.e. people who do not like salty foods tend to practice more salt-reducing behavior, leading to reduced levels in blood pressure. In a population, a small reduction in overall blood pressure can have large effects in overall prevalence of hypertension, in contrast to clinical studies where achievement of an individual's normal blood pressure is emphasized. Therefore, taste preference of the population should be considered for long-term blood pressure intervention programs.
Journal of The Korean Society of Integrative Medicine
/
v.7
no.1
/
pp.75-80
/
2019
Purpose : This study investigated the effect of bamboo stepping exercises on the blood pressure of the elderly. This study was performed for 8 weeks. Methods : The study participants included 25 people aged 65 and over. Of the participants, 16 were in the hypertensive elderly group and 9 were in the normal blood pressure elderly group. The participants stepped on semicircular bamboo for 20 minutes 3 times a week for 8 weeks. The participants' blood pressure was measured 3 times before and after 8 weeks of exercise. The mean values of the 3 before and after measurements were compared and analyzed statistically. Results : The systolic blood pressure of the hypertensive elderly group decreased significantly from $134.6{\pm}21.1mmHg$ to $119.9{\pm}18.1mmHg$ (p<.05). The diastolic blood pressure of the hypertensive elderly group decreased from $70.2{\pm}10.5mmHg$ to $66.1{\pm}9.8mmHg$, but the difference was not significant. The systolic blood pressure of the normal blood pressure elderly group decreased significantly from $127.2{\pm}18.7mmHg$ to $115.5{\pm}19mmHg$ (p<.05). The diastolic blood pressure of the normal blood pressure elderly group decreased from $72.6{\pm}11.3mmHg$ to $68.2{\pm}12mmHg$, but the decrease was not significant. Conclusion : After completing 8 weeks of the bamboo stepping exercises, the elderly participants' systolic blood pressure was effectively reduced. Today, lifestyle modifications, such as daily exercise, are necessary to control the blood pressure of the elderly. We hope that the bamboo stepping exercises, which are easy to perform and are not restricted by place and time, will become part of the elderly health policy.
The present study compared two indirect blood pressure methods at thoracic limb, pelvic limb, and coccygeal sites. For measurement of blood pressure, 48 client-owned dogs in a clinical setting were used. When comparing the results obtained by doppler and oscillometric methods, there were significant differences in blood pressure of the thoracic and pelvic limbs. The Doppler machine produced significantly higher blood pressure value than oscillometry measured at thoracic and pelvic limbs. The difference in blood pressure between the two methods was not significant when measured in the tail. Comparison of blood pressure measured at three different sites by doppler, blood pressure measured at pelvic limb was higher than at thoracic limb and tail. In case of oscillometry, there were no significant differences between the three sites. The results of this study indicate that mechanical and positional differences were existed in blood pressure measurements at the canine thoracic limb, pelvic limb and tail.
KSII Transactions on Internet and Information Systems (TIIS)
/
v.16
no.4
/
pp.1209-1223
/
2022
Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.
International journal of advanced smart convergence
/
v.1
no.2
/
pp.20-25
/
2012
The oscillometric method and Korotkoff sound method are the most common ways to measure the blood pressure. A new automatic blood pressure measurement device, which uses both oscillometric method and Korotkoff method, was developed. A pressure sensor was used to obtain cuff pressure and oscillation signal, and a microphone was used to detect Korotkoff sounds. Forty-five measurements from fifteen subjects were used for analysis. Correlation coefficients between the traditional auscultatory method and Korotkoff sound method were 0.9820 and 0.9721 for the systolic and diastolic blood pressure values, respectively. Standard deviations of differences for the systolic and diastolic blood pressure values were 1.3019 and 1.4495, respectively. Correspondingly, correlation coefficients between the traditional auscultatory method and oscillometric method using newly developed algorithm were 0.9651 and 0.9136 for the systolic and diastolic blood pressure values, with the standard deviations of 1.42 and 1.73, respectively. The results showed that the newly developed algorithm for oscillometirc method provide accurate blood pressure values, moreover, Korotkoff sound method using microphone provides even higher accuracy. Therefore, a new automatic device which utilizes both oscillometric method and Korotkoff sound method would provide the accurate and reliable blood pressure values.
Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
Journal of Korean Academy of Fundamentals of Nursing
/
v.8
no.3
/
pp.366-378
/
2001
Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.
Lee K. W.;Kim C. H.;Han K. B.;Kim H. J.;Jeon G. R.
Proceedings of the Korea Society for Simulation Conference
/
2005.05a
/
pp.149-153
/
2005
In the cardiovascular system, the waveform of the pulsatory blood pressure appears variously due to the cardiac impulse and compliance of blood vessels and arm tissue. We have constructed a blood pressure simulator to investigate effects of mechanical properties of artery walls and tissue on blood pressure measurements. The blood pressure simulator is designed to reproduce wave forms of blood pressure in human arteries. To minimize tracking error, we use a linear control valve, and adapt a hybrid control scheme which consists of a feedback controller and a feedforward controller. Any form of the pressure wave can be reproduced, changing function of the wave form in the computer connected to the simulator for control. From experiments, it has been shown that the simulator reproduces wave forms very well, and that the hybrid scheme adapted is superior to the feedback controller.
By far, studies on the effect of oral administration of peppermint essential oil on blood pressure are not consistent, increasing or decreasing. And the effect of inhalation of peppermint essential oil on blood pressure was not reported. This study was designed to clarify the effect of peppermint essential oil inhalation on the blood pressure and autonomic nervous system. Blood pressure and heart rate variability (HRV) as an indicator of autonomic nervous system activity were measured. The systolic and diastolic blood pressure was not changed significantly by inhalation of peppermint essential oil. Standard deviation of normal to normal (SDNN), a parameter of total activity of autonomic nervous system also was not changed significantly. High frequency (HF) power level, an indicator of parasympathetic nervous system activity was not changed by peppermint. These results indicate that action mechanism of peppermint essential oil on blood pressure is different by the method of administration, oral or inhalation.
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2000.10a
/
pp.451-454
/
2000
Invasive methode and Non-invasive methode are used in blood pressure measurement. The Invasive methode can Set the correct measured blood pressure but, it has patient feels uncomfortable. So most of cases use Non-invasive methode. The Oscillometric method is commonly apply to modem electric sphygmomanometer and using various algorithm. In this paper describe about a algorithm it control and to determinate the cuff pressure, and filtering that data for measure the blood pressure. The communicating with personal computer can pressure deflation is by Solenoid valve and it uses RS-232 system in packet communication. The main using algorithm for blood pressure measurements are maximum amplitude algorithm and oscillometric algorithm. MAA(maximum amplitude algorithm) has various measured oscillation it depend on patient's age, height, weight and arm circumference size. In this paper, 1 studied the various measured oscillation apply to characteristic ratio and can get the result of systolic blood pressure, diastolic blood pressure, mean blood pressure. It was not used same ratio to measuring oscillation. In the MAA(maximum amplitude algorithm), we hope for reduce the difference with the real blood pressure and the measured blood pressure, when it applied with various specific ratio.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.