• Title/Summary/Keyword: Blood Characteristics

Search Result 1,952, Processing Time 0.028 seconds

Comparison among diagnostic tools used for differential diagnosis of blood stasis pattern in Korea, China and Japan (한중일 어혈증 감별진단을 위한 도구의 비교)

  • Kim, Jiwon;Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Objectives The purpose of this study is to compare the representative differential diagnosis methods of blood stasis pattern used in Korea, China and Japan, and then to characterize each diagnostic method. Methods Through the journal databases, we have selected representative tools that were developed for differential diagnosis of blood stasis pattern in Korea, China and Japan. In order to characterize the selected check-lists or questionnaires, we investigated the number of items, contents, score calculation method, internal consistency, and accuracy of each selected tool. Results A total of four diagnostic tools were finally selected; quantitative diagnosis scale of blood stasis syndrome (QDSBSS), diagnostic criteria for blood stasis (DCBS), blood stasis questionnaire (BSQ), and blood stasis syndrome questionnaire (BSSQ). The key points in the differential diagnosis for blood stasis were different for each of the diagnostic tool. The key point was oral mucosa (including tongue) status in the QDSBSS. Meanwhile it was abdominal pain/resistance in the DCBS, and general pain in the BSQ. Accuracy of the QDSBSS, the BSQ and the BSSQ were powerful but all of them was not generalized. Conclusions Therefore, it is desirable to select and apply a plurality of appropriate tools according to the characteristics of the blood stasis patients.

  • PDF

A Study on the Shear Stress Distribution of the Steady and Physiological Blood Flows (정상 및 박동성 혈류의 전단응력분포에 관한 연구)

  • Suh, S.H.;Yoo, S.S.;Roh, H.W.;Shim, J.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.113-116
    • /
    • 1995
  • Steady and physiological flows of a Newtonian fluid and blood in the bifurcated arterial vessel are numerically simulated. Distributions of velocity, pressure and wall shear stress in the bifurcated arterial vessel are calculated to investigate the differences between steady and physiological flows. For the given Reynolds number physiological flow characteristics of a Newtonian fluid and blood in the bifurcated arterial vessel are quite different from those of steady flows. No flow separation or flow reversal in the bifurcated region in the downstream after stenosis appears during the acceleration phase. Also, no recirculation region is seen for steady flows. However, during the deceleration phase the flow began to exhibit flow reversal, which is eventually extended to the entire wall region.

  • PDF

Blood Biochemical Characteristics, Dietary Intake, and Risk Factors Related to Poor HbA1c Control in Elderly Korean Diabetes Patients: Comparison between the 4th(2007-2009) and the 7th(2016-2018) Korea National Health and Nutrition Examination Surveys (한국 당뇨병 노인의 혈액생화학적 특성, 식이 섭취, 당화혈색소 관련 위험 요인 및 위험도: 국민건강영양조사 제4기(2007-2009)와 제7기(2016-2018) 비교)

  • Oh, Sung-Won;Kim, Sook-Bae
    • Korean Journal of Community Nutrition
    • /
    • v.27 no.5
    • /
    • pp.406-421
    • /
    • 2022
  • Objectives: The purpose of this study was to investigate the blood biochemical characteristics, comorbidities, dietary intake, and other risk factors leading to poor glycated hemoglobin (HbA1c) control in elderly Korean diabetes patients over 65 years of age. Methods: Data from the 4th (2007-2009) and the 7th (2016-2018) Korea National Health and Nutrition Examination Surveys (KNHANES) were used. Socio-demographic characteristics (age, gender, region, household income, education level, marital status, nutrition education, diabetes duration and diabetes treatment), lifestyle characteristics (drinking, smoking, regular walking, and subjective health perception), anthropometric characteristics (height, weight, and waist circumference), blood biochemical characteristics (HbA1c, high- density lipoprotein cholesterol, triglycerides, total cholesterol, blood urea nitrogen, and blood creatinine), co-morbidities (obesity, hypertension, hypercholesterolemia, hypertriglyceridemia, and anemia), energy and nutrients intake, food group intake, and HbA1c control-related risk factors were compared. Results: Compared to the 4th survey, the 7th survey showed an increase in diabetes prevalence among men, an increase in the prevalence of diabetes in the older patients, and an increase in the duration of diabetes. The energy ratio from carbohydrate consumption in the 7th survey was lower than in the 4th. Compared to the 4th survey, thiamine and riboflavin intake had improved, and the intakes of vitamin A, vitamin C, and niacin had worsened in the 7th. A comparison of food group intakes showed that there was a decrease in the consumption of whole grains, potatoes, and milk and an increase in the intake of beverages and alcoholic beverages. The risk factors for poor control of HbA1c were the duration of diabetes and co-morbid hypertriglyceridemia in the 4th survey, whereas subjective health perception, obesity, and hypercholesterolemia as co-morbidities were found to be risk factors in the 7th in addition to the risk factors highlighted in the 4th survey. Conclusions: For the future management of elderly Korean diabetes patients, greater care is indicated for men over 75 years, and those with low levels of education. It is necessary to increase the intake of milk and vegetables, and reduce the intake of beverages and alcoholic beverages. In addition, it is necessary to reduce the incidence of obesity, hypercholesterolemia, and hypertriglyceridemia for proper control of blood sugar.

NUMERICAL STUDY ON THE BLOOD FLOW CHARACTERISTICS OF STENOSED AND BIFURCATED BLOOD VESSELS WITH A PHASE ANGLE CHANGE OF A PERIODIC ACCELERATION (주기 가속도 위상변화에 따른 협착 및 분지 혈관의 혈류 특성에 대한 수치해석적 연구)

  • Ro, K.C.;Cho, S.W.;Lee, S.H.;Ryou, H.S.
    • Journal of computational fluids engineering
    • /
    • v.13 no.3
    • /
    • pp.44-50
    • /
    • 2008
  • The present study is carried out in order to investigate the effect of the periodic acceleration in the stenosed and bifurcated blood vessels. The blood flow and wall shear stress are changed under body movement or acceleration variation. Numerical studies are performed for various periodic acceleration phase angles, bifurcation angles and section area ratios of inlet and outlet. It is found that blood flow and wall shear stress are changed about ${\pm}20%$ and ${\pm}24%$ as acceleration phase angle variation with the same periodic frequency. also wall shear stress and blood flow rate are decreased as bifurcation angle increased.

A study on Blood pigments removal of butchery wastewater by heat processed Eggshell (Heat processed Eggshell에 의한 도축폐수의 혈색소 제거에 관한 연구)

  • 박경식
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.37-43
    • /
    • 2000
  • The purpose of this experimental study examine characteristics of blood pigments removal of butchery wastewater by heat processed eggshell, compare activated carbon with its efficiency. Calcined eggshell were classified into four kinds of mesh as HPES-32(Heat Processed Eggshell 32 $mesh=500{\mu}m$), HPES-48($300{\mu}m$), HPES-150($180{\mu}m$) and HPES-150($106{\mu}m$). And two contacting process of CMFA(Complete Mixing Float Adsorption) and FLFA(Fixing layer Flow Adsorption) Were used for getting removal efficiency of blood pigments. In case of using CMFA process, the removal efficiency of blood pigments was occurred as HPES-80>HPES-150>HPES-32, but in case of using FLFA process was occurred as HPES-150>HPES-80>HPES-48>HPES-32. The two results between CMFA and FLFA were differ in strength of removal efficiency of blood pigments.

  • PDF

Methods of The Promoting Blood Circulation and Removing Blood Stasis by Wang Cheong-Im (왕청임(王淸任)의 활혈거어법(活血祛瘀法))

  • Kim Hya-Sung;Jung Seung-Woo;Lee Jong-Il;Kwon Dong-Yeul
    • Herbal Formula Science
    • /
    • v.12 no.2
    • /
    • pp.47-55
    • /
    • 2004
  • Wang Cheong-Im(1768-1831) in the Ching dynasty conducted the therapy of blood statis syndrome using the methods for promoting blood circulation and removing blood statis in accordance with the description in the book Uirimgaechak(醫林改錯). Thus, this study examined his methods for promoting blood circulation and removing blood statis, therapy of blood statis syndrome and mechanism of function. Since the blood statis symptoms varied on the parts where the blood statis were occurred, the therapy for promoting blood circulation and removing blood statis applied different treatments and drugs depending on the symptoms. The therapy also valued much of qi and blood. Qi is important to the human body so that the therapy replenished qi and simultaneously promoted the blood circulation as mainly focusing on the regulation of the qi flow. Moreover, the therapy adjusted the level of removing blood circulation and rate of replenishing qi. The degree of prescription and drug was differentiated in treating a variety of blood statis because of the difference in the seriousness and characteristics of blood circulation, amount and application of drug and combination of drugs. The therapy was careful about the regulation of qi for the replenishment of qi and the nurishment of blood for the promotion of blood circulation. If the blood circulation was blocked, the blood statis was formed. Accordingly, the phlegm and the blood statis were closely related. Then, the phlegm and blood statis were simultaneously treated. The therapy divided the properties of blood statis into the stagnant excess syndrome, the stagnant deficiency syndrome, the stagnant cold syndrome and the stagnant heat syndrome and treated the patients suitable for each symptom. The function of mechanism in the treatment using the methods for promoting blood circulation and removing blood statis was divided into the stagnation of blood and interruption in blood circulation. The therapy laid stress on promoting blood circulation and removing blood circulation. With such emphasis, the therapy facilitated the circulation in the bloood vessel, prevented the coagulation of blood, removed the blood statis and promoted the metabolism. Then, the physiological function and pathological change internal organs were improved. Furthermore, the therapy strengtened the heart and promoted the blood circulation by improving the systemic blood circulation. Moreover, the therapy facilitated the micro-circulation by adjusting the balance of body.

  • PDF

Microsystems for Whole Blood Purification and Electrophysiological Analysis

  • Han, Arum;Han, Ki-Ho;Mohanty Swomitra K.;Frazier A. Bruno
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • This paper presents the development of a microsystem for whole blood purification and electrophysiological analysis of the purified cells. Magnetophoresis using continuous diamagnetic capture (DMC) was utilized for whole cell purification and electrical impedance spectroscopy (EIS) was utilized for electrophysiological analysis of the purified cells. The system was developed on silicon and plastic substrates utilizing conventional microfabrication technologies and plastic microfabrication technologies. Using the magnetophoretic microseparator, white blood cells were purified from a sample of whole blood. The experimental results of the DMC microseparator show that 89.7% of the red blood cells (RBCs) and 72.7% of the white blood cells (WBCs) could be continuously separated out from a whole blood using an external magnetic flux of 0.2 T. EIS was used as a downstream whole cell analysis tool to study the electrophysiological characteristics of purified cells. In this work, primary cultured bovine chromaffin cells and human red blood cells were characterized using EIS. Further analysis capabilities of the EIS were demonstrated by successfully obtaining unique impedance signatures for chromaffin cells based on the whole cell ion channel activity.

An Experimental Setup for Measuring the Performance of Blood Pumps (혈액펌프 성능평가를 위한 실험장치 구성)

  • Kim, Sung-Gil;Hong, Seokbin;Kim, Taehong;Kim, Wonjung;Kang, Seongwon;Kang, Shin-Hyoung;Hur, Nahmkeon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.55-60
    • /
    • 2016
  • We present an experimental setup for measuring the mechanical performance of centrifugal blood pumps. Using a 3D printer to construct supporting parts and magnetic couplings, we developed the measurement setup that can be used for various types of blood pumps. The experimental setup is equipped with sensors to measure a variety of mechanical characteristics of blood pumps including pressure, flow rate, torque, temperature, and rotating speed. Our experimental measurements for two commercial blood pumps are consistent with data provided by manufacturers, which indicates that the our setup offers the accurate measurements of blood pump performance. Utilizing the experimental setup, we tested aqueous glycerin solutions mimicking the density and viscosity of blood, which enabled us to predict the difference in operations using water and blood.

Blood pressure simulator using hybrid controller (합성제어기를 이용한 혈압 시뮬레이터의 구현)

  • Kim, C.H.;SaGong, G.;Nam, Gi-Gon;Jeon, R.
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.44-51
    • /
    • 2007
  • A hybridized simulator for generating blood pressure waveform is proposed to study the remedy and/or evaluation of the conventional sphygmomanometer utilizing the oscillometric method which is widely applied. The blood pressure of a flowing fluid was controlled for the blood vessel's condition caused by a rhythmical and periodical contraction/relaxation because of the special excitatory and conductive system of the heart. In this study, a hybridized controller composed of the PI feedback controller and the feedforward controller. The inverse dynamics function is proposed to operating the control valve while the pressure is applied in an oil pressure tank. The proposed hybrid simulator reproducing the blood pressure waveform in an artificial blood vessel has kept the control performance consistent over all range. Based on these results, the proposed simulators could be applied to the development and compensation of the non invasive sphygmomanometer type as well as to study the characteristics of the blood pressure and blood vessel.

Hydraulic Design Optimization and Performance Analysis of a Centrifugal Blood Pump (원심형 혈액펌프의 최적화 수력설계 및 성능해석)

  • Park Moo Ryong;Yoo Seong Yeon;Oh Hyoung Woo;Yoon Eui Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.87-94
    • /
    • 2006
  • This paper presents the hydrodynamic design and performance analysis method for a miniaturized centrifugal blood pump using three-dimensional computational fluid dynamics (CFD) code. In order to obtain the hydraulically high efficient configuration of a miniaturized centrifugal blood pump for cardiopulmonary circulation, a well-established commercial CFD code was incorporated considering detailed flow dynamic phenomena in the blood pump system. A prototype of centrifugal blood pump developed by the present design and analysis method has been tested in the mock circulatory system. Predicted results by the CFD code agree very well with in vitro hydraulic performance data for a centrifugal blood pump over the entire operating conditions. Preliminary in vivo animal testing has also been conducted to demonstrate the hemodynamic feasibility for use of centrifugal blood pump as a mechanical circulatory support. A miniaturized centrifugal blood pump developed by the hydraulic design optimization and performance prediction method presented herein shows the possibility of a good candidate for intra and extracorporeal cardiopulmonary circulation pump in the near future.