• Title/Summary/Keyword: Block

Search Result 14,792, Processing Time 0.034 seconds

SHIP BLOCK ARRANGEMENT SYSTEM BASED ON IMAGE PROCESSING

  • Park, Jeong-Ho;Choi, Wan-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.104-106
    • /
    • 2008
  • This paper proposes an image based method for arranging ship blocks in a dockyard. The problem of appropriately arranging numerous blocks has to be carefully planned because it has close relation to the effectiveness of the whole working process. To implement the system, the block shape and feature points have to be obtained from block image. The block arrangement system can be implemented by the fusion of the block shape extraction and image matching technology.

  • PDF

Development of Polymer Mortar Guide Block for the Blind Handicapped People (폴리머 복합재료를 이용한 유도 블럭의 개발)

  • 이기원;연규석;이윤수;지경용
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.330-335
    • /
    • 1999
  • The objective of this stu요 was to develop a polymer mortar guide block for the blind handicapped people. A high strength and a long durability polymer concrete using unsaturated polyester resin was used to developed the block and to improve the exiting cement mortar guide bloc. Physical and mechanical properties of the polymer mortar guide block were investigated with respect to absorptivity, impact strength, bending strength compared to those of the conventional cement guide block. The polymer mortar guide block was proven to have properties , indication that the block have better industrial applications.

  • PDF

A Numerical Simulation of Heat and Fluid Flow in the Motor Block Room of a Motorized Car (동력객차 동력실 내부의 열유체 유동의 수치 시뮬레이션)

  • 김학범;허재경;이기열
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.589-594
    • /
    • 1998
  • Heat and fluid flow in the motor block room of a motorized car is numerically simulated. The motorized car, composed of a motor block room and a passenger room, supplies additional Power to achieve the design speed. A motor block, a transformer, and a fan are equipped in the motor block room. Flow phenomena in the ducts on the motor block and power transformer are investigated. Also, the three dimensional heat and fluid flow in the motor block room is simulated to give a qualitative information of the flow characteristics.

  • PDF

A Clinical Evaluation of Splanchnic Nerve Block with Absolute Ethanol (무수 알코올에 의한 내장신경차단에 관한 임상적 연구)

  • Lee, Hyo-Keun;Yoon, Duck-Mi;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.111-121
    • /
    • 1991
  • It has been well known that the splanchnic nerve block is effective for patients who suffer from intractable upper abdominal pain. However, it is unclear whether the effect of the splanchnic nerve block depends on varied alcoholic concentration. In this study, an attempt was made to use absolute ethanol on patients who recieved a splanchnic nerve block at Severance Hospital during the period from September l990 to April l991. The results are as follows; 1) Among the 33 patients, including 22 males and 1l females, the fifties and sixties were the major age groups. 2) Stomach cancer was the most common underlying disease(13 cases), with pancreatic can- cer next(9 cases). 3) The main locations of pain were the upper abdomen, epigastrium, and entire abdomen in decreasing order. 4) There were 17 cases who had had chemotherapy, and 1l cases of whom had had surgery before the splanchnic nerve block. 5) The volume of alcohol used was 12 ml bilaterally. 6) Among the 33 patients, 15.2% required a second block within two weeks of the first block. One case required a third block. 7) The most common complications of splanchnic nerve block were hypotension(33.3%), occasional transient sharp burning pain, flushing of face, pain on injection site, nausea, vomiting, dyspnea, chest discomfort and diarrhea. 8) The supplemental block most commonly used was a continuous epidural block. It was used both as a diagnostic block and to afford relief from pain before the splanchnic nerve block was done. 9) The interval between the receiving the absolute ethanol block and discharge was within 2 weeks in l5 cases. But, in the patients with poor general health, the interval between the splanchnic nerve block and discharge prolonged. The above results suggest that bilateral splanchnic nerve block done with absolute ethanol after an effective test block with 1% lidocaine under C-arm fluroscopic control is satisfactory and reliable. Still, 26.6% of the patients received a repeat block within 2 weeks. Insufficient spread of ethanol due to its small volume seems to be a major factor in the repeat block. Minimizing the incidence of repeat block remains a problem to be solved.

  • PDF

Design of An Amplifier using DGS Block (DGS 방식 DC Block을 이용한 증폭기의 설계)

  • 이경희;정용채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.432-438
    • /
    • 2001
  • In this paper, after applying Defected Ground Structure(DGS) to DC block, changes of gap and length of λ/4 coupled line are investigated by EM simulation and fabrication. As a result, on condition of the same output with the case using typical DC block, the gap between λ/4 coupled line is widen from 0.1 mm to 0.46 mm by 0.36 mm and the length of λ/4 coupled line gets shorter from 17.7 mm to 13.2 mm by 4.5 mm. Also three type power amplifiers using blocking capacitor, typical DC block and DGS DC block are fabricated and investigated. At first, when S parameter characteristics of each amplifier are considered at frequency band of 3.2 +-0.O5 GHz, every amplifier has similar characteristics of gain and S parameter. Second when the output power of amplifiers is 25 dBm after putting CW signal of 3.2 GHz into three type amplifiers, the difference of dominant signal and 2nd harmonic signal using blocking capacitor, typical DC block and DGS DC block is each -44.83 dBc, -66.84 dBc and -64.33 dBc. Therefore harmonic characteristics of amplifiers using typical DC block and DGS DC block is almost same.

  • PDF

A Pathway to Microdomain Alignment in Block Copolymer/Nanoparticle Thin Films under Electric Field

  • Bae, Joonwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2689-2693
    • /
    • 2014
  • The control over microstructure in block copolymer thin films using external electric fields has become an interesting research topic. In this article, the effect of nanoparticle on the microdomain alignments in block copolymer (polystyrene-b-poly(2-vinylpyridine)/nanoparticle (Au) thin films under electric fields has been examined with transmission electron microscopy. The homogeneous dispersion of Au nanoparticles into the block copolymer matrix was achieved by surface modification of nanoparticles with compatible ligands. Compared with the phenomenon seen in the pristine block copolymer thin films, a peculiar alignment behavior was observed in the block copolymer/nanoparticle hybrid thin films under electric fields. In addition, the different pathways observed in the pristine and nanoparticle incorporated block copolymer thin films were also monitored as a function of exposure time. This work can provide the fundamental information for understanding microdomain alignment in block copolymer/nanoparticle thin films under external electric fields.

IP Design of Corrected Block TEA Cipher with Variable-Length Message for Smart IoT

  • Yeo, Hyeopgoo;Sonh, Seungil;Kang, Mingoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.724-737
    • /
    • 2020
  • Corrected Block TEA(or XXTEA) is a block cipher designed to correct security weakness in the original block TEA in 1998. In this paper, XXTEA cipher hardware which can encrypt or decrypt between 64-bit and 256-bit messages using 128-bit master key is implemented. Minimum message block size is 64-bit wide and maximal message block size is 256-bit wide. The designed XXTEA can encrypt and decrypt variable-length message blocks which are some arbitrary multiple of 32 bits in message block sizes. XXTEA core of this paper is described using Verilog-HDL and downloaded on Vertex4. The operation frequency is 177MHz. The maximum throughput for 64-bit message blocks is 174Mbps and that of 256-bit message blocks is 467Mbps. The cryptographic IP of this paper is applicable as security module of the mobile areas such as smart card, internet banking, e-commerce and IoT.

Block Designs for Partial Diallel Crosses (부분이면교배에서의 블록계획)

  • 손영남;최규정
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.2
    • /
    • pp.367-379
    • /
    • 2002
  • In this paper, the method of constructing incomplete block designs for comparing general combining abilities of p inbred lines for partial diallel crosses is proposed. These partial diallel crosses block designs are constructed by using m-associate class partially balanced incomplete block designs with block size 2 and balanced incomplete block designs. Also, the efficiencies of block designs obtained through this method are tabulated for number of lines 24 or less.

Psoas Compartment Block for the Relief of Lumbar and Left Thigh Pain after Operation of Second Lumbar Compression Fracture -A case report- (척추 수술 후 발생된 요부 및 좌측 대퇴전부 통증 치료를 위한 대요근 근구 차단술의 효과 -증례 보고-)

  • So, Keum-Young;Park, You-Jin;Koog, Jong-Soo
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.314-316
    • /
    • 1998
  • Psoas compartment block has been used to provide anesthesia and analgesia of hip joint. This block is advocated for relief of pain of various origins in the thigh, leg and lumbar area. A-40-year-old women complained of pain in the left thigh and lumbar area after operation of the second lumbar vertebral compression fracture. To relieve pain, caudal block was performed. This block reduced in lumbar pain but left thigh pain persisted. So, we were performed psoas compartment block using mepivacaine and dexamethasone, which relieved the pain in the left thigh and lumbar area. We recommend psoas compartment block as useful and simple method for patients with thigh and lumbar area pain, especially when the epidural block is not feasible.

  • PDF

The variable-sized block matching motion estimation using quadtree (Quadtree를 이용한 가변 block 움직임 추정)

  • 이원희;김상기;김재영;정진현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.20-23
    • /
    • 1996
  • The block matching algorithm for the motion estimation is relatively simple to implement, and thus widely applied in image sequence coding such as H.261, MPEG- I and MPEG-2. Most techniques of the block matching method use fixed-size blocks for the motion estimation. And their success relies on the assumption that the motion within each block is uniform. But if the block size is increased to reduce the number of motion vectors for high data compression, the estimated image brings about many errors. In this paper, the variable-sized blocks are used to solve this problem. And the top down method is used to select the block size.

  • PDF