• Title/Summary/Keyword: Bipolar-type DC distribution

Search Result 8, Processing Time 0.02 seconds

Complementary Power Control of the Bipolar-type Low Voltage DC Distribution System

  • Byeon, Gilsung;Hwang, Chul-Sang;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Jong-Yul;Kim, Kisuk;Ko, Bokyung;Kim, Eung-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.786-794
    • /
    • 2015
  • In this paper, a new power control strategy for the bipolar-type low voltage direct current (LVDC) distribution system is being proposed. The dc distribution system is considered as an innovative system according to the increase of dc loads and dc output type distribution energy resources (DERs) such as photovoltaic (PV) systems and energy storage systems (ESS). Since the dc distribution system has many advantages such as feasible connection of DERs, reduction of conversion losses between dc output sources and loads, no reactive power issues, it is very suitable solution for new type buildings and residences interfaced with DERs and ESSs. In the bipolar-type, if it has each grid-interfaced converter, both sides (upper, lower-side) can be operated individually or collectively. A complementary power control strategy using two ESSs in both sides for effective and reliable operation is proposed in this paper. Detailed power control methods of the host controller and local controllers are described. To verify the performances of the proposed control strategy, simulation analysis using PSCAD/EMTDC is being performed where the results show that the proposed strategy provides efficient operations and can be applied to the bipolar-type dc distribution system.

Power Flow Study of Low-Voltage DC Micro-Grid and Control of Energy Storage System in the Grid

  • Kim, Dong-Eok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.549-558
    • /
    • 2017
  • DC distribution has several differences compared to AC distribution. DC distribution has a higher efficiency than AC distribution when distributing electricity at the same voltage level. Accordingly, power can be transferred further with low-voltage DC. In addition, power flow in a DC grid system is produced by only a voltage difference in magnitude. Owing to these differences, operation of a DC grid system significantly differs from that of an AC system. In this paper, the power flow problem in a bipolar-type DC grid with unbalanced load conditions is organized and solved. Control strategy of energy storage system on a slow time scale with power references obtained by solving an optimization problem regarding the DC grid is then proposed. The proposed strategy is verified with computer simulations.

A Study on SFCL with IGBT Based DC Circuit Breaker in Electric Power Grid

  • Bae, SunHo;Kim, Hongrae;Park, Jung-Wook;Lee, Soo Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1805-1811
    • /
    • 2017
  • Recently, DC systems are considered as efficient electric power systems for renewable energy based clean power generators. This discloses several critical issues that are required to be considered before the installation of the DC systems. First of all, voltage/current switching stress, which is aggravated by large fault current, might damage DC circuit breakers. This problem can be simply solved by applying a superconducting fault current limiter (SFCL) as proposed in this study. It allows a simple use of insulated-gate bipolar transistors (IGBTs) as a DC circuit breaker. To evaluate the proposed resistive type SFCL application to the DC circuit breaker, a DC distribution system is composed of the practical line impedances from the real distribution system in Do-gok area, Korea. Also, to reflect the distributed generation (DG) effects, several DC-to-DC converters are applied. The locations and sizes of the DGs are optimally selected according to the results of previous studies on DG optimization. The performance of the resistive type SFCL applied DC circuit breaker is verified by a time-domain simulation based case study using the power systems computer aided design/electromagnetic transients including DC (PSCAD/ EMTDC(R)).

Study on the Voltage Stabilization Technology Using Photovoltaic Generation Simulator in Three-Level Bipolar Type DC Microgrid

  • Kim, Taehoon;Kim, Juyong;Cho, Jintae;Jung, Jae-Seung
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1123-1130
    • /
    • 2018
  • Voltage stabilization is an essential component of power quality in low voltage DC (LVDC) microgrid. The microgrid demands the interconnection of a number of small distributed power resources, including variable renewable generators. Therefore, the voltage can be maintained in a stable manner through the control of these distributed generators. In this study, we did research on the new advanced operating method for a photovoltaic (PV) simulator in order to achieve interconnection to a bipolar LVDC microgrid. The validity of this voltage stabilization method, using the distributed generators, is experimentally verified. The test LVDC microgrid is configured by connecting the developed PV simulator and DC load, DC line, and AC/DC rectifier for connecting the main AC grid. The new advanced control method is applied to the developed PV simulator for the bipolar LVDC grid in order to stabilize the gird voltage. Using simulation results, the stabilization of the grid voltage by PV simulator using the proposed control method is confirmed the through the simulation results in various operation scenarios.

Observation of Plasma Shape by Continuous dc and Pulsed dc (직류 방전과 펄스 직류 방전에 의한 플라즈마 형상 관찰)

  • Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.3
    • /
    • pp.133-138
    • /
    • 2009
  • Effects of bipolar pulse driving frequency between 50 kHz and 250 kHz on the discharge shapes were analyzed by measuring plasma characteristics by OES (Optical Emission Spectroscopy) and Langmuir probe. Plasma characteristics were modeled by a simple electric field analysis and fluid plasma modeling. Discharge shapes by a continuous dc and bipolar pulsed dc were different as a dome-type and a vertical column-type at the cathode. From OES, the intensity of 811.5 nm wavelength, the one of the main peaks of Ar, decreased to about 43% from a continuous dc to 100 kHz. For increasing from 100 kHz to 250 kHz, the intensity of 811.5 nm wavelength also decreased by 46%. The electron density decreased by 74% and the electron temperature increased by 36% at the specific position due to the smaller and denser discharge shape for increasing pulse frequency. Through the numerical analysis, the negative glow shape of a continuous dc were similar to the electric potential distribution by FEM (Finite Element Method). For the bipolar pulsed dc, we found that the electron temperature increased to maximum 10 eV due to the voltage spikes by the fast electron acceleration generated in pre-sheath. This may induce the electrons and ions from plasma to increase the energetic substrate bombardment for the dense thin film growth.

Effect by Temperature Distribution of Target Surface during Sputtering by Bipolar Pulsed Dc and Continuous Dc (직류와 양극성 펄스직류에 의한 스퍼터링시 타겟 표면의 온도 분포와 그 영향)

  • Yang, Won-Kyun;Joo, Jung-Hoon;Kim, Young-Woo;Lee, Bong-Ju
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.45-51
    • /
    • 2010
  • We measured the temperature of target surface inducing by various physical phenomenon on magnetron sputtering target and confirmed the possibilities if the temperature distribution could affect plasma and deposited thin film. The target of magnetron sputtering has two types: round type and rectangular type. In a rectangular target, the concentrated discharge area by corner effect by magnetic field and non-uniform erosion of target are generated. And we found the generation of non-uniform temperature distribution on the target surface from this. This area was $10{\sim}20^{\circ}C$ higher than non-sputtering area. And if particles are generated during sputtering process, they were $20^{\circ}C$ higher than the area where is higher than non-sputtering area. These effects result in non-uniformity of thin films, crack of ceramic target, and shortening target life by non-uniform erosion.

Advanced IGBT structure for improved reliability (신뢰성 개선된 IGBT 소자 신구조)

  • Lee, Myoung Jin
    • Journal of Digital Contents Society
    • /
    • v.18 no.6
    • /
    • pp.1193-1198
    • /
    • 2017
  • The IGBT structure developed in this paper is used as a high power switch semiconductor for DC transmission and distribution and it is expected that it will be used as an important electronic device for new and long distance DC transmission in the future by securing fast switching speed and improved breakdown voltage characteristic. As a new type of next generation power semiconductors, it is designed to improve the switching speed while at the same time improving the breakdown voltage characteristics, reducing power loss characteristics, and achieving high current density advantages at the same time. These improved properties were obtained by further introducing SiO2 into the N-drift region of the Planar IGBT and were compared and analyzed using the Sentaurus TCAD simulation tool.

Experimental Study on Electrical Agglomeration of Liquid Particles in an Alternating Electric Field (AC 전기장내 하전 액체 입자의 응집에 관한 실험적 연구)

  • Ji, Jun-Ho;Hwang, Jung-Ho;Bae, Gwi-Nam;Kim, Yong-Gin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.442-450
    • /
    • 2001
  • Experiments were carried out on agglomeration of bipolarly charged particles in an alternating current electric field. Laboratory-scale setup was built and experiments were conducted at atmospheric condition. DOS(Di-octyl Sebacate) particles with 100% purity were generated by an atomizer. The particles were branched into two, each of which passed through a wire-to-plate type charging section where a positive or a negative DC high voltage was applied and was charged positively or negatively. These bipolarly charged particles together passed through an agglomeration section where an $\pm$20kV AC power was applied between two plates. The resident time in the agglomeration section was adjusted as l sec. Particle sampling was made by a cascade impactor (MOUDI). The effect of agglomeration system on the reduction ratio of particles below l ㎛ was 42∼45%. Effect of AC frequency on the particle size distribution was found insignificant.