• Title/Summary/Keyword: Biosensor

Search Result 688, Processing Time 0.023 seconds

Development of Cyanide Sensor Using S. cerevisiae (S. cerevisiae를 이용한 시안센서의 개발)

  • 김종민;이현우
    • KSBB Journal
    • /
    • v.11 no.6
    • /
    • pp.669-675
    • /
    • 1996
  • Two types of cyanide sensor system were constructed for monitoring river water simply. One is membrane type flow system composed of S. cerevisiae coated membrane and oxygen electrode, the other is reactor type flow system composed of S. cevevisiae immobilized reactor and two oxygen electrode. S. cerevisiae and oxygen electrode were used for detecting cyanide compounds. These sensors are based on the inhibition of cyanides on the respiration activity of S. cerevisiae. Membrane type sensor system could detect cyanides ranging 0.10∼1.00ppm, and the respiration activity of S. cerevisiae continued for a day. Reactor type sensor system composed of immobilized chitopearl HP-5020 with S. cerevisiae could detect cyanides in the range of 0.10∼1.00ppm, and maintained 90% respiration activity for sixteen days. It was found that the optimum reactor size exist for the reactor type biosensor when respirating activity inhibition is used for detection of cyanides.

  • PDF

Study of Enzyme Immobilization on Composite of CTA and PCL Membrane for Biosensor (바이오센서용 CTA와 PCL 혼합막에의 효소고정화 기법의 개발)

  • 홍성현;김태진
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.468-474
    • /
    • 1995
  • The disposable glucose bio-sensor using composite of CTA and PCL membrane was developed for measurement of glucose. The most effective membrane was composed of CTA/PCL(80/20, w/w) and glutaraldehyde one-step immobilization method ($10{\mu}m$ thickness) for glucose sensor gave the best result among various methods, considering oxygen permeability and electronic sensitivity. A scanning electron micrograph of the cross-section of a typical asymmetric CTA/PCL composite membrane showed that the membrane fused with a dense layer covered with a GOD-glutaraldehyde. Glucose oxidase immoblilized on the membrane showed the linearity between difference of absolute amperometric values and glucose concentrations within 7mM when the GOD immobilized electrode was used. About 35% of activity was remained after 8 days when the tyrosinase was immobilized on CTA/PCL (80/20) membrane.

  • PDF

Development and Assessment of New RT-qPCR Assay for Detection of HIV-1 Subtypes

  • Lim, Kwanhun;Park, Min;Lee, Min Ho;Woo, Hyun Jun;Kim, Jong-Bae
    • Biomedical Science Letters
    • /
    • v.22 no.3
    • /
    • pp.83-97
    • /
    • 2016
  • The measurement of viral load in HIV-1 infected patients is essential for the establishment of a therapeutic strategy. Several commercial assays have shown shortcomings in quantifying rare genotypes of HIV-1 such as minor groups of N and O. In this study, the HIV-1 RT-qPCR assay was developed. The primers and probe of HIV-1 were designed to target the pol gene and to increase the detection efficiency of various subtypes including group N and O. The HIV-1 quantitative RT-qPCR assay was assessed for its analytical performance and clinical evaluation. The LoD was determined to 33.9 IU/ml. The LoD of several subtypes including A, C, D, CRF_01AE, F, CRF_02AG, G and H, were determined to less than 40 IU/ml. The HIV-1 quantitative RT-qPCR assay was evaluated using the China National Reference Panel of HIV-1 RNA to determine the analytical performance. The results were all within the acceptable range. The clinical evaluation was performed at Hunan CDC in China. The clinical evaluation results were compared with those of the China domestic commercial kit. A significant correlation (fresh samples; $R^2=0.84$, P<0.001, frozen samples; $R^2=0.76$, P<0.001) between the two systems was observed for 64 fresh samples and 76 frozen samples with viral loads, and the Bland-Altman plot showed good agreement (98.4%, 96.1%, respectively). In conclusion, the HIV-1 quantitative RT-qPCR assay had comparable analytical performance with several commercial kits. The study provides basic data for the research of HIV-1 diagnosis and the development of P < HIV-1 molecular diagnostic assay.

Smart Elderly-care System using Smart-phone (스마트폰을 이용한 고령자용 스마트 간병 시스템)

  • Cho, Myeon-gyun
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.129-135
    • /
    • 2017
  • In this paper, we propose a system to monitor the condition of elderly people who are uncomfortable by using smart-phone and biometric sensor at any time and for care-givers to provide with the best medical service anytime and anywhere. The proposed system monitors the status of the elderly through various bionic sensors installed in the hospital ward based on the Arduino system and not only provides the physiological and medical services required by the elderly, but also informs the guardian so that he can cope with the emergency. In conclusion, this paper suggests that a reading light used by elderly people can operate as a home server with a biosensor using Arduino and Android applications (Apps.), and the smart-phone of care-givers is configured as a remote management and a emergency call system. Therefore, this study suggests important ways to improve the satisfaction of medical service for the both elderly people and care-givers of chronic diseases in the future.

Electrochemistry of Hemoglobin in the Chitosan and TiO2 Nanoparticles Composite Film Modified Carbon Ionic Liquid Electrode and Its Electrocatalysis

  • Sun, Wei;Li, Xiaoqing;Liu, Shufeng;Jiao, Kui
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.582-588
    • /
    • 2009
  • Direct electron transfer of hemoglobin (Hb) in the chitosan (CTS) and $TiO_2$ nanoparticles (nano-$TiO_2$) composite films was achieved by using a room temperature ionic liquid of 1-butyl-3-methylimidazolium hexafluorophosphate ($BMIMPF_6$) modified carbon paste electrode (CILE) as the basal electrode. UV-Vis and FT-IR spectroscopy indicated that Hb in the film retained the native structure. Electrochemical investigation indicated that a pair of well-defined quasi-reversible redox peaks of Hb heme Fe(III)/Fe(II) was obtained with the formal potential located at -0.340 V (νs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical parameters such as the electron transfer coefficient (α), the electron transfer number (n) and the standard electron transfer rate constant ($k_s$) were got as 0.422, 0.93 and 0.117 $s^{-1}$, respectively. The fabricated CTS/nano-$TiO_2$/Hb/CILE showed good electrocatalytic ability to the reduction of trichloroacetic acid (TCA) and hydrogen peroxide ($H_2O_2$), which exhibited a potential application in fabricating a new kind of third generation biosensor.

Biochip System for Environmental Monitoring using Nanobio Technology (나노바이오기술을 이용한 환경모니터링용 바이오칩 시스템)

  • Kim, Young-Kee;Min, Jun-Hong;Oh, Byung-Keun;Choi, Jeong-Woo
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.378-386
    • /
    • 2007
  • Bio-sensing devices, which are basically integrated and miniaturized assay systems consisted of bioreceptor and signal transducer, are advantageous in several ways. In addition to their high sensitivity, selectivity, simplicity, multi-detection capability, and real time detection abilities, they are both very small and require relatively inexpensive equipments. Two core technologies are required to develop bio-sensing devices; the fabrication of biological receptor module (both of receptor development and immobilisation of them) and the development of signal transducing instruments containing signal generation technique. Various biological receptors, such as enzymes, DNA/RNA, protein, and cell were tried to develop bio-sensing devices. And, the signal transducing instruments have also been extensively studied, especially with regard to electrochemical, optical, and mass sensitive transducers. This article addresses bio-sensing devices that have been developed in the past few years, and also discusses possible future major trends in these devices.

A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism (Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서)

  • Yun, Sung-Sik;Lee, Soo-Hyun;Ahn, Chong-H.;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

Organic Memory Device Using Self-Assembled Monolayer of Nanoparticles (나노입자 자기조립 단일층을 이용한 유기메모리 소자)

  • Jung, Hunsang;Oh, Sewook;Kim, Yejin;Kim, Minkeun;Lee, Hyun Ho
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.515-520
    • /
    • 2012
  • In this review, the fabrication of silicon based memory capacitor and organic memory thin film transistors (TFTs) was discussed for their potential identification tag applications and biosensor applications. Metal or non-metal nanoparticles (NPs) could be capped with chemicals or biomolecules such as protein and oligo-DNA, and also be self-assembly monolayered on corresponding target biomolecules conjugated dielectric layers. The monolayered NPs were formed to be charging elements of a nano floating gate layer as forming organic memody deivces. In particular, the strong and selective binding events of the NPs through biomolecular interactions exhibited effective electrostatic phenomena in memory capacitors and TFTs formats. In addition, memory devices fabricated as organic thin film transistors (OTFTs) have been intensively introduced to facilitate organic electronics era on flexible substrates. The memory OTFTs could be applicable eventually to the development of new conceptual devices.

Real-time FRET imaging of cytosolic FAK signal on microwavy patterned-extracellular matrix (ECM) (미세파상 패턴 ECM 에서 세포질 FAK 신호의 실시간 FRET 이미징)

  • Suh, Jung-Soo;Jang, Yoon-Kwan;Kim, Tae-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Human mesenchymal stem cells (hMSC) are multipotent stromal cells that have great potential to differentiate into a variety of cell types such as osteocytes, chondrocytes, and myocytes. Although there have been many studies on their clinical availability, little is known about how intracellular signals can be modulated by topographic features of the extracellular matrix (ECM). In this study, we investigated whether and how microwavy-patterned extracellular matrix (ECM) could affect the signaling activity of focal adhesion kinase (FAK), a key cellular adhesion protein. The fluorescence resonance energy transfer (FRET)-based FAK biosensor-transfected cells are incubated on microwavy-patterned surfaces and then platelet derived growth factor (PDGF) are treated to trigger FAK signals, followed by monitoring through live-cell FRET imaging in real time. As a result, we report that PDGF-induced FAK was highly activated in cells cultured on microwavy-patterned surface with L or M type, while inhibited by H type-patterned surface. In further studies, PDGF-induced FAK signals are regulated by functional support of actin filaments, microtubules, myosin-related proteins, suggesting that PDGF-induced FAK signals in hMSC upon microwavy surfaces are dependent on cytoskeleton (CSK)-actomyosin networks. Thus, our findings not only provide new insight on molecular mechanisms on how FAK signals can be regulated by distinct topographical cues of the ECM, but also may offer advantages in potential applications for regenerative medicine and tissue engineering.

Dielectrophoresis for Control of Particle Transport: Theory, Electrode Designs and Applications (입자 이동 제어를 위한 유전영동: 이론, 전극 구조 및 응용분야)

  • Lee, Minji;Kim, Ji-Hye;Koo, Hyung-Jun
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.149-163
    • /
    • 2019
  • Under non-uniform electric field, a directional force along the electric field gradient is applied to matter having permanent or induced dipoles. The transport of particles by the directional force is called dielectrophoresis (DEP). Since the strength and direction of the DEP force depend on parameters, such as permittivity and conductivity of particles and surrounding media, and frequency of the applied AC electric field, particle can be precisely manipulated by controlling the parameters. Moreover, unlike electrophoresis, DEP can be applied to any particles where dipole is effectively induced by electric field. Such a DEP technique has been used in various fields, ranging from microfluidic engineering to biosensor and microchip research. This paper first describes the fundamentals of DEP, and discusses representative microelectrode designs used for DEP study. Then, exemplary applications of DEP, such as separation, capture and self-assembly of particles, are introduced.