• 제목/요약/키워드: Biomedical optics

검색결과 128건 처리시간 0.022초

Microfluidic Flow Cytometry: Principles of Cell Analysis and Applications

  • Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2006
  • Microsystems create new opportunities for conventional cell analysis by combining microfluidics and flow cytometry. This article describes recent developments in conventional flow cytometers and related microfluidic flow cytometers to detect, analyze, and sort cells or particles. Flow cytometry strongly consisted of fluidics, optics and electronics requires a large space to equip various components, which are mostly the fluidic components such as compressor, fluid handling system. Adopting microfluidics into flow cytometry enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this paper, we review various efforts that take advantage of novel techniques to build microfluidic cell analysis systems with high-speed analytical capability. Highly integrated microfluidic cytometry shows great promise for basic biomedical and pharmaceutical research, and robust and portable point-of-care devices could be used in clinical settings.

  • PDF

Image Plate로서의 X선 조사에 대한 Amorphous Selenium Plate 표면 Potential 특성 연구 (The Study for Characteristics between Amorphous Selenium Plate Surface Potential and X-ray Exposure by Image Plate)

  • 최준영;조승열;김명수;임종덕;김덕훈;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.41-44
    • /
    • 1996
  • There are studied for filmness methods due to disadvantage of conventional X-ray system. Have high DQE, high SNR, amorphous selenium was investigated with image plate. In this point, characteristics of all amorphous selenium image plate was investigated to understand the relationship between the amount of the X-ray exposure and the superficial charge potential in this study. Specially, changes in charge at the surface of the amorphous selenium plate with respect to change of X-ray energy(KeV) was investigated. It was found that the surface charge potential at the amorphous selenium inclosed with respect to the increse in X-ray exposure and that the changed surface potential was a semilinearity in 12.5KeV - 22.5KeV range. Therefore, which suggests that these results call be applied to the development of X-ray image plate.

  • PDF

주시점의 위치에 따른 시 표적이 시피질의 뇌파에 미치는 영향 (Effect of EEG Wave Type on Visual Cortex of Visual Target according to Position of Fixation Point)

  • 김덕훈;조진욱;남상희
    • 한국안광학회지
    • /
    • 제5권1호
    • /
    • pp.101-105
    • /
    • 2000
  • 본 연구는 한국인을 대상으로 주시점의 위치에 따른 시 표적이 뇌파에 미치는 영향을 조사한 것이다. 시유발 전위 장치는 BIO-Pag를 이용하였으며, 검사 결과는 586 컴퓨터에 입력하여 분석하였다. 조도는 500lux이여 시표는 직경이 3 cm인 붉은 광점을 사용하였다. 수렴과 개산에 따른 결과는 다음과 같다. 1. 시자극에 관계하는 시피질의 뇌파의 출현 빈도는 델타파, 베타파, 세타파, 그리고 알파파의 순으로 나타났다. 2. 수렴 상태는 개산에 비해서 속파 성분이 많이 출현되었다. 3. 수렴은 개산에 비해서 베타파와 알파파가 많아 나타났다. 4. 수렴과 개산에서 진폭에 대한 히스토 그램은 비가우시안 모양이다. 5. 뇌파의 진폭에 대한 위상 분석은 거의 선상을 나타내었다.

  • PDF

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Biphasic Tumor Oxygenation during Respiratory Challenge may Predict Tumor Response during Chemotherapy

  • Lee, Songhyun;Jeong, Hyeryun;Anguluan, Eloise;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.1-6
    • /
    • 2018
  • Our previous study showed that switching the inhaled gas from hypoxic gas to hyperoxic gas for 10 minutes increased tumor oxygenation and that the magnitude of oxyhemoglobin increase responded earlier than tumor volume change after chemotherapy. During 10 minutes of inhaled-oxygen modulation, oxyhemoglobin concentration first shows a rapid increase and then a slow but gradual increase, which has been fitted with a double-exponential equation in this study. Two amplitude values, amplitudes 1 and 2, respectively represent the magnitudes of rapid and slow increase of oxyhemoglobin. The trends of changes in amplitudes 1 and 2 were different, depending on tumor volume when chemotherapy started. However, both amplitudes 1 and 2 changed earlier than tumor volume, regardless of when chemotherapy was initiated. These results imply that by observing amplitude 1 changes post chemotherapy, we can reduce the time of a respiratory challenge from 10 minutes to less than 2 minutes, to see the chemotherapy response. We believe that by reducing the time of the respiratory challenge, we have taken a step forward to translating our previous study into clinical application.

Enhancement of Speckle Contrast in vivo by Combining Linearly Polarized Laser Light and an Analyzer

  • Qureshi, Muhammad Mohsin;Mac, Khuong Duy;Kim, Andrew Hyunjin;Kim, Young Ro;Chung, Euiheon
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.351-361
    • /
    • 2021
  • Speckle imaging is capable of dynamic data acquisition at high spatiotemporal resolution, and has played a vital role in the functional study of biological specimens. The presence of various optical scatterers within the tissue causes alteration of speckle contrast. Thus structures like blood vessels can be delineated and quantified. Although laser speckle imaging is frequently used, an optimization process to ensure the maximum speckle contrast has not been available. In this respect, we here report an experimental procedure to optimize speckle contrast via applying different combinations of varying polarization of the illuminating laser light and multiple analyzer angles. Specifically, samples were illuminated by the p-polarization, 45°-polarization, and s-polarization of the incident laser, and speckle images were recorded without and with the analyzer rotated from 0° to 180° (Δ = 30°). Following the baseline imaging of a solid diffuser and a fixed brain sample, laser speckle contrast imaging (LSCI) was successfully performed to visualize in vivo mouse-brain blood flow. For oblique laser illumination, the maximum contrast achieved with p-polarized and s-polarized light was perpendicular to the analyzer's axis. This study demonstrates the optimization process for maximizing the speckle contrast, which can improve blood-flow estimation in vivo.

칼라콘택트렌즈의 물성적 특성 평가 (The Evaluation of Property of Colored Contact Lenses)

  • 박현주
    • 한국안광학회지
    • /
    • 제10권2호
    • /
    • pp.119-126
    • /
    • 2005
  • 2개사 칼라콘택트렌즈에 대한 물성적 특성을 평가 비교하였다. 제조된 인공누액을 사용하여 단백질 침착율과 습윤성, 주사전자현미경과 원자간력현미경을 이용하여 렌즈의 표면 거칠기를 관찰하였다. 결과는 다른 특성들은 일반 소프트콘택트렌즈와 비교해서 큰 차이를 보이지 않았으나 주사전자현미경적 관찰에서 건조시 심한 균열을 보였다. 원자간력현미경적 관찰에서 렌즈 표면요철은 발견되지 않아 표면거칠기는 일반 소프트콘택트렌즈와 차이가 없었다. 렌즈 앞면과 뒷면에 대한 염료 침착을 확인한 결과 염료는 렌즈내부에 존재함을 알 수 있었다.

  • PDF

칼라콘택트렌즈의 제조 - 제조방법과 특성에 대해 - (Review on the fabrication method and characteristics of colored contact lens)

  • 박현주
    • 한국안광학회지
    • /
    • 제10권2호
    • /
    • pp.127-132
    • /
    • 2005
  • 칼라콘택트렌즈는 의료용으로 사용되기 시작하여 최근 들어 미용의 목적으로 그 수요가 급격히 증가하고 있는 추세이다. 칼라콘택트렌즈의 제조방법으로는 pigment application method, pigment inlay method, sandwich method, binding method 등이 있는데 현재 국내에서는 binding method가 주로 사용된다. 칼라 콘택트렌즈의 용도와 제조 방법 면에서 채색(tinted)과 착색(cosmetic)으로 크게 분류되는데 채색은 염색방식으로 널리 알려진 방법이며, 착색은 박막공법에 의해 제조된다. 이에 따라 본 해설의 목적은 칼라콘택트렌즈의 제조방법 및 방법에 따른 특성을 비교하고, 칼라콘택트렌즈의 특성을 이해하는데 도움을 주기 위함이다.

  • PDF

Optical Coherence Tomography Based on a Continuous-wave Supercontinuum Seeded by Erbium-doped Fiber's Amplified Spontaneous Emission

  • Lee, Ju-Han;Jung, Eun-Joo;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.49-54
    • /
    • 2010
  • In this study, the use of a continuous-wave (CW) supercontinuum (SC) seeded by an erbium-doped fiber's amplified spontaneous emission (ASE) for optical-coherence tomography imaging is experimentally demonstrated. It was shown, by taking an in-depth image of a human tooth sample, that due to the smooth, flat spectrum and long-term stability of the proposed CW SC, it can be readily applied to the spectral-domain optical-coherence tomography system. The relative-intensity noise level and spectral bandwidth of the CW SC are also experimentally analyzed as a function of the ASE beam power.

Hepatic Cell Membrane Changes of Rats in the Early Postmortem Period

  • Yoon, Hyung-Won;Yoon, Chong-Guk;Cho, Hyun-Gug
    • 대한의생명과학회지
    • /
    • 제8권2호
    • /
    • pp.89-93
    • /
    • 2002
  • To investigate the postmortem changes in hepatic cell membrane, the rats were sacrificed with cervical dislocation and kept in an incubator at $25^{\circ}C$, 70% of humidity for 12 hours. The biochemical experiments in postmortem were done at 2, 4, 8 and 12 hours. The degree of rigor mortis and algor mortis were increased with the time during 12 hours. The contents of hepatic malondialdehyde were rapidly increased ai 2 hours, and gradually decreased afterward. In histological findings, after 8 hours, the clotted blood was seen in central vein and sinusoids, and especially portal veins were dilated a1though the structure of hepatic lobules was preserved well. Furthermore, both in the histochemical and enzymatic examinations, membrane bounding alkaline phosphatase activities were gradually decreased with the time. In conclusion, the activity of membrane bounding alkaline phosphatase was linearly decreased with time in the early postmortem period and so it might be referred to the possibility fur the estimation of death time in the early postmortem period.

  • PDF