• Title/Summary/Keyword: Biomedical monitoring

Search Result 454, Processing Time 0.022 seconds

Development of Noncontact Temperature Sensor Using Silver Halide Optical Fiber for Medical Usages (Silver Halide 광섬유를 이용한 의료용 비접촉식 온도 센서 개발)

  • Yoo, Wook-Jae;Cho, Dong-Hyun;Jang, Kyoung-Won;Chung, Soon-Cheol;Tack, Gye-Rae;Lee, Bong-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.337-342
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halide optical fiber. The infrared collimator and focus head are connected both ends of a silver halide optical fiber with SMA connectors and used to collimate radiations of a heat source and to focus them to infrared sensors such as a pyroelectric sensor and a thermopile sensor, respectively. The relation ships between the temperatures of a heat source and the output signals of the infrared sensors are determined to measure the surface temperature of a heat source. The measurable temperature range is from 25 to $60^{\circ}C$. It is expected that a noncontact temperature sensor using a silver halide optical fiber can be developed for medical usages such as temperature monitoring during hyperthermia, cryosurgery, laser surgery and diagnostic procedure based on the results of this study.

Development of a Monitoring System for Water-borne Bacteria by a Molecular Technique, PCR-RFLP-sequence Analysis

  • Lee, Ji-Young;Jeong, Eun-Young;Lee, Kyu-sang;Seul-Ju;Kim, Jong-Bae;Kang, Joon-Wun;Lee, Hye-Young
    • Biomedical Science Letters
    • /
    • v.9 no.3
    • /
    • pp.139-144
    • /
    • 2003
  • Since water borne infection causes acute diseases and results in spread of diseases by secondary infection, the prevention is very important. Therefore, it is necessary to have a method that is rapid and effective to monitor pathogenic bacteria in drinking water. In this study, we employed a systematic method, Polymerase Chain Reaction-Restriction Fragment Length Polymorphism (PCR-RFLP) analysis, to develop an effective monitoring system for possible bacterial contaminants in drinking water. For this purpose, PCR primers were derived from 992 bp region of the 16s rRNA gene that is highly conserved through the different species of prokaryotes. To test whether the PCR primers designed are indeed useful for detecting all the possible microbial contaminants in the water, the primers were used to amplify 16s rRNA regions of different microbial water-borne pathogens such as E. coli, Salmonella, Yersinia, Listeria, and Staphylococcus. As expected, all of tested microorganisms amplified expected size of PCR products indicating designed PCR primers for 16s rRNA indeed can be useful to amplify all different microbial water-borne pathogens in the water. Furthermore, to test whether these 16s rRNA based PCR primers can detect bacterial populations present in the water, water samples taken from diverse sources, such as river, tap, and sewage, were used for amplification. PCR products were for then subjected for cloning into a T-vector to generate a library containing 16s rRNA sequences from various bacteria. With cloned PCR products, RFLP analysis was done using PCR products digested with restriction enzyme such as Hae III to obtain species-specific RFLP profiles. After PCR-RFLP, the bacterial clones which showed the same RFLP profiles were regarded as the same ones, and the clones which showed distinctive RFLP profiles were subsequently subjected for sequence analysis for species identification. By this PCR-RFLP analysis, we were able to reveal diverse populations of bacteria living in water. In brief, in unsterilized natural river water, over 60 different species of bacteria were found. On the other hand, no PCR products were detected in drinking tap-water. The results from this study clearly indicate that the PCR-RFLP-sequence analysis can be a useful method for monitoring diverse, perhaps pathogenic bacteria contaminated in water in a rapid fashion.

  • PDF

Development of Peripheral Devices on the Endoscopic Surgery System (내시경 수술시스템의 주변장치 개발)

  • Lee, Young-Mook;Song, Chul-Gyu;Lee, Sang-Min;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

A Study on the Estimation of Continuous Blood Pressure using PIT and Biometric Parameters

  • Park Eun-Kyoung;Cho Baek-Hwan;Park Sang-Hae;Lee Jong-Youn;Hwang Hwan-Sik;Park Hun-Ki;Lee Jong-Shill;Kim In-Young;Kim Sun-I
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • In this paper, we propose a subject-independent regression model to estimate systolic blood pressures (SBP) conveniently and continuously. There have been several researches on estimating SBP with pulse transit time (PTT) and they showed promising results. However, previous studies used only PTT as the estimation parameter, and their models were generated with just one person's PTT data which is not applicable to estimating other person's SBP. Therefore, we collected several additional biometric parameters with 202 healthy subjects. After statistical analysis of measured biometric parameters with SBP, we chose final estimating parameters including PTT to generate a multiple linear regression model for estimating SBP. Comparing the results of our study with approvable standards of automated sphygmomanometers developed by Association for the Advancement of Medical Instrumentation and approved by American National Standards Institute (ANSI/AAMI) indicates that our proposed method for continuously blood pressures monitoring gives an acceptable error.

HRV Evaluation under Stress Condition by Using Patch Type Bipolar Heart Activity Monitoring System (패치형 바이폴라 심장활동 모니터링 시스템을 이용한 스트레스 상태의 HRV 평가)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Lee, Kang-Hwi;Choi, Hee-Jung
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • In this study, we have developed the patch type HAMS (Heart Activity Monitoring System) which is non-restricted, non-awarable and non-invasive. The module using wireless telecommunication to receive the ECG (electrocardiogram) signal at the computer has mobility which it easily monitors the heart activity of subjects in no time for long term at any time and places. We developed the small patch type electrode which can be attached on the chest. Also the reliability and moving artifact of ECG signal measured by this electrode have been verified. Using HAMS, we measured the HRV (Heart Rate Variability) parameters, the questionnaire evaluation for anxiety and stress and the amount of stress hormone (cotisol) to evaluate the stress effect in HRV on the same subject. As a result of comparing the values under non stressed and stressed condition, there was significant difference on many parameters. And the parameter highly related with stress on Pearson's Correlation Coefficient has been examined. These show that using HAMS is able to evaluate the function of autonomic nervous system. Therefore, we can predict heart problem in daily life by using HAMS. Also we expect that this module can be applied for more application as health monitoring system.

  • PDF

Smart Health Monitoring System (SHMS) An Enabling Technology for patient Care

  • Irfan Ali Kandhro;Asif Ali Wagan;Muhammad Abdul Aleem;Rasheeda Ali Hassan;Ali Abbas
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.3
    • /
    • pp.43-52
    • /
    • 2024
  • Health Monitoring System is a sophisticating technology and another way to the normal/regular management of the health of the patient. This Health Monitoring Mobile Application is a contribution from our side to the public and to the overall health industry in Pakistan. With the help of Health mobile application, the users will be able to store their medical records, prescriptions and retrieve them later. The users can store and keep track of their vital readings (heart rate, blood pressure, fasting glucose, random glucose). The mobile application also shows hospitals that are nearby in case the user wants to avail of any medical help. An important feature of the application is the symptoms-based disease prediction, the user selects the symptoms which he has and then the application will name certain diseases that match those symptoms based on relevant algorithms. The major advances and issues have been discussed, and as well as potential tasks to health monitoring will be identified and evaluated.

Estimation of Respiration Using Photoplethysmograph During Sleep (광용적맥파 신호를 이용한 수면 중 호흡 추정)

  • Park, Jong-Uk;Lee, Jeon;Lee, Hyo-Ki;Kim, Hojoong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.105-110
    • /
    • 2013
  • Respiratory signal is one of the important physiological information indicating the status and function of the body. Recent studies have provided the possibility of being able to estimate the respiratory signal by using a change of PWV(pulse width variability), PRV(pulse rate variability) and PAV(pulse amplitude variability) in the PPG (photoplethysmography) signal during daily life. But, it is not clear whether the respiratory monitoring is possible even during sleep. Therefore, in this paper, we estimated the respiration from PWV, PRV and PAV of PPG signals during sleep. In addition, respiration rates of the estimated respiration signal were calculated through a time-frequency analysis, and errors between respiration rates calculated from each parameter and from reference signal were evaluated in terms of 1 sec, 10 sec and 1 min. As a result, it showed the errors in PWV(1s: $36.38{\pm}37.69$ mHz, 10s: $36.53{\pm}38.16$ mHz, 60s: $30.35{\pm}38.72$ mHz), in PRV(1s: $1.45{\pm}1.38$ mHz, 10s: $1.44{\pm}1.37$ mHz, 60s: $0.45{\pm}0.56$ mHz), and in PAV(1s: $1.05{\pm}0.81$ mHz, 10s: $1.05{\pm}0.79$ mHz, 60s: $0.56{\pm}0.93$ mHz). The errors in PRV and PAV are lower than that of PWV. Finally, we concluded that PRV and PAV are more effective than PWV in monitoring the respiration in daily life as well as during sleep.

CDMA-Based Ubiquitous $SaO_2$ Monitoring System for Oxygen Therapy Patients

  • Lee, Seung-Yup;Kang, Jae-Min;Shin, Il-Hyeung;Lee, Jae-Ho;Lee, Choon-Taek;Kim, Hee-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.274-281
    • /
    • 2006
  • In this paper, we propose a ubiquitous $SaO_2$ monitoring system for patients using oxygen therapy. For these patients, the ability to monitor oxygen saturation ubiquitously is very important fur accurate adjustment of ventilator's flow rate to match the patient's time-varying requirements with the shortest lag time possible. We have developed a portable device to measure $SaO_2$ and transmit it to hospital in real-time or in store-and-forward mode through the integration of $Bluetooth^{TM}$ technology and the code division multiple access (CDMA) cellular network. We also developed software for doctors to receive and manage the patients' $SaO_2$ information. Performance of the developed system was evaluated as acceptable by assessing the accuracy of the measured oxygen saturation value and the stability of communication network. Test results in real clinical setting demonstrate that our system is feasible for immediate use in home oxygen therapy.

Development of Respiratory Monitoring System by Inductive Plethysmography (인덕턴스 호흡감시 시스템의 개발)

  • Kim, Deok-Won;Yeon, Dong-Su;Kim, Su-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.353-358
    • /
    • 1995
  • The impedance pneumography which is widely used in monitoring respiration is simple to use and noninvasive, but it is sensitive to motion artifacts and insensitive to detect obstructive apnea. A 3-channel respiratory inductive plethysmography (RIP) developed in this study detects inductance change of the inductance band induced by cross-sectional area change of thorax or abdomen as one breathes. It was confirmed that RIP was less sensitive to various motion artifacts but more sensitive to detection of obstructive apnea than impedance pneumography.

  • PDF

Design of Apnea Monitoring System by impedance technique (임피던스를 이용한 무호흡감시 시스템 설계)

  • Park, S.B.;Jeon, D.K.;Yoon, H.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.232-235
    • /
    • 1997
  • Apnea refers to episode of apnea (or not breathing) lasting more than 10 seconds that occur while sleeping. These episodes, whitch can occur hundreds of times per night, may transiently awaken resulting in fragmentation of sleep. Although the precise cause of Sudden Infant Death Syndrome(SIDS) are still unclear, there is evidence to suggest that hypoxaemia may be a contributory actor. Transcutaneous oxygen monitor can be used, but it is very difficult to use or baby stayed at home. In this reason, monitors whitch is easy or deal with are reqiured. In 1972, Steinschieder reported that two of the five infants noted to have apnea lasting or more than 20 seconds later died of SIDS episode, he also suggested that home monitoring or neonates should be used or managing apnea at home. Transthoracic electrical impedance technique is used or acquiring respiration waveform and detecting episode of apnea state. Transthoracic electrical impedance measurements have been made from the human trunk over the frequency range 9.6KHz to 614KHz. We conclude that application of impedance technique or detecting apnea state is proper or neonates.

  • PDF