• Title/Summary/Keyword: Biomedical application

Search Result 855, Processing Time 0.026 seconds

Biphasic Tumor Oxygenation during Respiratory Challenge may Predict Tumor Response during Chemotherapy

  • Lee, Songhyun;Jeong, Hyeryun;Anguluan, Eloise;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • Our previous study showed that switching the inhaled gas from hypoxic gas to hyperoxic gas for 10 minutes increased tumor oxygenation and that the magnitude of oxyhemoglobin increase responded earlier than tumor volume change after chemotherapy. During 10 minutes of inhaled-oxygen modulation, oxyhemoglobin concentration first shows a rapid increase and then a slow but gradual increase, which has been fitted with a double-exponential equation in this study. Two amplitude values, amplitudes 1 and 2, respectively represent the magnitudes of rapid and slow increase of oxyhemoglobin. The trends of changes in amplitudes 1 and 2 were different, depending on tumor volume when chemotherapy started. However, both amplitudes 1 and 2 changed earlier than tumor volume, regardless of when chemotherapy was initiated. These results imply that by observing amplitude 1 changes post chemotherapy, we can reduce the time of a respiratory challenge from 10 minutes to less than 2 minutes, to see the chemotherapy response. We believe that by reducing the time of the respiratory challenge, we have taken a step forward to translating our previous study into clinical application.

Small Molecules that Potentiate Neuroectodermal Differentiation of Mouse Embryonic Stem Cells

  • Lee, Jonghwan;Rhee, Ki-Jong;Jung, Dongju
    • Biomedical Science Letters
    • /
    • v.19 no.1
    • /
    • pp.32-40
    • /
    • 2013
  • Pluripotent stem cells (PSCs) have enormous potential in the biomedical sciences because they can grow continuously and differentiate into any kind of cell in the body. However, for future application in regenerative medicine, it is still a challenge to control the differentiation of PSCs without using genetic materials. To control the differentiation of PSCs, small molecules might be the best substitute for genetic materials considering the following advantages: small size, which enables penetration of plasma membrane; easy-to-modify structure; and low chance of genetic recombination in treated cells. Herein, we introduce small molecules that induce the neuroectodermal differentiation of mouse embryonic stem cells (ESCs). The small molecules were identified via ESC-based consecutive screenings of small-molecule libraries composed of 324 natural compounds or 93 selected drugs. The natural compounds discovered in the first screening were used to select 93 structurally similar drugs out of 1,200 approved drugs. In the second screening, among the 93 compounds, we found 4 drugs that induced the neuroectodermal differentiation of ESCs. These drugs were progesteroneor corticoid-derivatives. Our results suggest that small molecules targeting the progesterone receptor or glucocorticoid receptor could be used as chemical tools to induce the differentiation of PSCs into a specific germ lineage.

Electrodeposition of Gold on Fluorine-Doped Tin Oxide: Characterization and Application for Catalytic Oxidation of Nitrite

  • Rahman, Md. Mahbubur;Li, Xiao-Bo;Lopa, Nasrin Siraj;Lee, Jae-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.7
    • /
    • pp.2072-2076
    • /
    • 2014
  • Sub-micrometer size gold particles were electrodeposited on a transparent fluorine-doped tin oxide (FTO) from acetonitrile solution containing $AuCl_4{^-}$ and tetramethylammonium tetraflouroborate (TMATFB) for detecting $NO_2{^-}$. A series of two-electron ($2e^-$) and one-electron ($1e^-$) reductions of the $AuCl_4{^-}-AuCl_2{^-}-Au$ redox systems were observed at FTO and a highly stable and homogeneous distribution of Au on FTO (Au/FTO) was obtained by stepping the potential from 0 to -0.55 V (vs. Ag/$Ag^+$). The Au/FTO electrode exhibited sufficiently high catalytic activity toward the oxidation of $NO_2{^-}$ with a detection limit (S/N = 3) and sensitivity of 2.95 ${\mu}M$ and 223.4 ${\mu}A{\cdot}cm^{-2}{\cdot}mM^{-1}$, respectively, under optimal conditions. It exhibited an interference-free signal for $NO_2{^-}$ detection with excellent recoveries from real samples.

Researches of the Real-time Medical Imaging Precessing Board using ASIC architecture (ASIC을 이용한 고속의료영상처리보드의 개발을 위한 기초연구)

  • Seo, J.H.;Park, H.M.;Ha, T.H.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.299-300
    • /
    • 1998
  • Recently the development of medical modality like as MRI, 3D US, DR etc is very active. Therefore it is more required not only the enhancement of quality in medical service but the improvement of medical system based on quantization, minimization, and optimization of high speed. Especially, as the changing into the digital modality system, it gets to start using ASIC(Application Specific Integrated Circuit) to realize one board system. It requires the implementation of hardware debugging and effective speedy algorithm with more speed and accuracy in order to support and replace existing device. If objected image could be linked to high speed process board with special interface and pre-processed using FPGA, it can be used in real time image processing and protocol of HIS(Hospital Information System). This study can support the basic circuit design of medical image board which is able to realize image processing basically using digitalized medical image, and to interface between existing device and image board containing image processing algorithm.

  • PDF

Implementation of Urinary Incontinence Therapy Device with Wireless Bluetooth Communication (무선 요실금 치료기의 구현)

  • Lee, Seung-Jik;Kim, Kyung-Ah;Lee, Tae-Soo;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.197-202
    • /
    • 2006
  • Devices in current market to perform electrical stimulation therapy of the urinary incontinence frequent in aging women are very much impractical to us ε due to the wired configuration. The present study implemented new wireless device to enhance self as well as in-hospital therapy with the easiest and the most convenient application. The therapy system consisted of two modules, called 'master' and 'slave', communicating with each other by the wireless Bluetooth protocol. The patient controls therapy processes on the master module in hand, transmitting the required informations to operate the slave module placed within her pants with the viginal electrode connected, delivering appropriate electrical stimulation. Wireless communication enabled self therapy with clothes on, leading to a great convenience for the patient. The stimulation output signal was comparable to commercialized products in both waveform and stimulation capacity.

The Effect of Thoracic Joint Mobilization on the Changes of the Thoracic Kyphosis Angle and Static and Dynamic Balance

  • Jeong, Hae-Jin;Kim, Byeong-Jo
    • Biomedical Science Letters
    • /
    • v.25 no.2
    • /
    • pp.149-158
    • /
    • 2019
  • The objective of this study was to evaluate the effects of thoracic mobilization (TM) on the angle of thoracic kyphosis, and static and dynamic balances by application period. The subjects of this study were 18 adult males and females (${\geq}20years\; old$) who had the angle of thoracic kyphosis equal to or higher than $40^{\circ}$. A pre-test was conducted for all subjects and TM was carried out. Data were collected before the intervention, 3 weeks after the intervention, and 6 weeks after the intervention. It was measured three times per measurement and mean values were used for the analysis. The results of this study showed that the angle of thoracic kyphosis significantly (P<.05) decreased after applying TM. However, the migration area ($mm^2$) of the center of pressure (COP) in the static balance did not vary significantly. In the case of the dynamic balance, when eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks. When eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks and 6 weeks. Therefore, an intervention for improving the human body alignment and balance should be applied for a long-term, rather than a short-term, in order to be effective.

Force Analysis on the Nano/Micro Particle in a Flow using Immersed Boundary-Lattice Boltzmann Method (가상경계-격자 볼츠만 방법을 이용한 유동장내 나노/마이크로 입자에 작용하는 힘의 해석)

  • Jo, Hong Ju;Lee, Sei Young
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.35-44
    • /
    • 2022
  • Immersed boundary-Lattice Boltzmann Method (IB-LBM) is used for the analysis of flow over the circular cylinder in the concept of fluid-structure interaction analysis (FSI). Recently, IB-LBM has shown the enormous possibility for the application of various biomedical engineering fields, such as the movement of a human body or the behavior of the blood cells and/or particle-based drug delivery system in blood vessels. In order for the numerical analysis of the interaction between fluid and solid object, immersed boundary method and lattice Boltzmann method are coupled to analyze the flow over a cylinder for low Reynolds laminar flow (Re=10, 20, 40 and 100) with Zhu-He boundary condition at the boundary. With the developed IB-LBM, the flow around the cylinder in the uniform flow is analyzed for the laminar flow and the drag and lift coefficients and recirculation length are compared to the previous results.

Imipramine enhances neuroprotective effect of PEP-1-Catalase against ischemic neuronal damage

  • Kim, Dae-Won;Kim, Duk-Soo;Kim, Mi-Jin;Kwon, Soon-Won;Ahn, Eun-Hee;Jeong, Hoon-Jae;Sohn, Eun-Jeong;Dutta, Suman;Lim, Soon-Sung;Cho, Sung-Woo;Lee, Kil-Soo;Park, Jin-Seu;Eum, Won-Sik;Hwang, Hyun-Sook;Choi, Soo-Young
    • BMB Reports
    • /
    • v.44 no.10
    • /
    • pp.647-652
    • /
    • 2011
  • The protein transduction domains have been reported to have potential to deliver the exogenous molecules, including proteins, to living cells. However, poor transduction of proteins limits therapeutic application. In this study, we examined whether imipramine could stimulate the transduction efficiency of PEP-1 fused proteins into astrocytes. PEP-1-catalase (PEP-1-CAT) was transduced into astrocytes in a time- and dose-dependent manner, reducing cellular toxicity induced by $H_2O_2$. Additionally, the group of PEP-1-CAT + imipramine showed enhancement of transduction efficiency and therefore increased cellular viability than that of PEP-1-CAT alone. In the gerbil ischemia models, PEP-1-CAT displayed significant neuroprotection in the CA1 region of the hippocampus. Interestingly, PEP-1-CAT + imipramine prevented neuronal cell death and lipid peroxidation more markedly than PEP-1-CAT alone. Therefore, our results suggest that imipramine can be used as a drug to enhance the transduction of PEP-1 fusion proteins to cells or animals and their efficacies against various disorders.

A Pressure Applied Low-Level Laser Probe to Enhance Laser Photon Density in Soft Tissue (생체조직내 레이저 광 밀도 향상을 위한 압력 인가형 저출력 레이저 프로브)

  • Yeo, Chang-Min;Park, Jung-Hwan;Son, Tae-Yoon;Lee, Yong-Heum;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • Laser has been widely used in various fields of medicine. Recently, noninvasive low-level laser therapeutic medical devices have been introduced in market. However, low-level laser cannot deliver enough photon density to expect positive therapeutic results in deep tissue layer due to the light scattering property in tissue. In order to overcome the limitation, this study was aimed to develop a negative pressure applied low-level laser probe to optimize laser transmission pattern and therefore, to improve photon density in soft tissue. In order to evaluate the possibility of clinical application of the developed laser probe, ex-vivo experiments were performed with porcine skin samples and laser transmissions were quantitatively measured as a function of tissue compression. The laser probe has an air suction hole to apply negative pressure to skin, a transparent plastic body to observe variations of tissue, and a small metallic optical fiber guide to support the optical fiber when negative pressure was applied. By applying negative pressure to the laser probe, the porcine skin under the metallic optical fiber guide is compressed down and, at the same time, low-level laser is emitted into the skin. Finally, the diffusion images of laser in the sample were acquired by a CCD camera and analyzed. Compared to the peak intensity without the compression, the peak intensity of laser increased about $2{\sim}2.5$ times and FWHM decreased about $1.67{\sim}2.85$ times. In addition, the laser peak intensity was positively and linearly increased as a function of compression. In conclusion, we verified that the developed low-level laser probe can control the photon density in tissue by applying compression, and therefore, its potential for clinical applications.

Event Transmission of Respiratory rate and Heart rate Measured on Wheelchair (휠체어에서 호흡수와 심박수 측정 및 이벤트 전송)

  • Han, Dong-Kyoon;Kim, Jong-Myoung;Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.443-450
    • /
    • 2008
  • The purpose of this study is to measure both ECG and BCG(Ballistocariograph) signal of a subject on moving or resting wheelchair and detect the heart rate and respiratory rate and transmit an event message to remote server on emergent situation. To acquire ECG and BCG data, amplifier circuits were composed to be suitable for their characteristics. The output signals were converted to digital data and stored in bio-signal archiving media(SD card). CDMA module was used to transmit the event data on ECG electrode detachment and the received data was monitored by the developed C# application program. 5 volunteers participated in the experiment to evaluate the validity of the developed device. When the event occurs in each subject, 48 Kbyte data, stored for 32 seconds from that point, was transmitted to remote server through CDMA cellular phone network correctly. The received data of ECG, BCG, and 3-axial acceleration could be archived in server and the heart rate and respiratory rate could be measured and analyzed. The developed device in this study could acquire the ECG and BCG data of subjects on wheelchair simultaneously and measure their heart rate and respiratory rate. In addition, event data was verified to be transmitted to remote server without any errors.