• Title/Summary/Keyword: Biomedical Engineering

Search Result 7,033, Processing Time 0.031 seconds

Characterization studies of digital x-ray detector based on mercuric iodide (Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구)

  • Cho, Sung-Ho;Park, Ji-Koon;Choi, Jang-Yong;Suck, Dae-Woo;Cha, Byung-Yul;Nam, Sang-Hee;Lee, Byum-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

Combination Therapy of the Active KRAS-Targeting Antibody inRas37 and a PI3K Inhibitor in Pancreatic Cancer

  • Lee, Ji Eun;Woo, Min Gyu;Jung, Kyung Hee;Kang, Yeo Wool;Shin, Seung-Min;Son, Mi Kwon;Fang, Zhenghuan;Yan, Hong Hua;Park, Jung Hee;Yoon, Young-Chan;Kim, Yong-Sung;Hong, Soon-Sun
    • Biomolecules & Therapeutics
    • /
    • v.30 no.3
    • /
    • pp.274-283
    • /
    • 2022
  • KRAS activating mutations, which are present in more than 90% of pancreatic cancers, drive tumor dependency on the RAS/mitogen-activated protein kinase (MAPK) and phosphoinositide 3-kinase (PI3K)/AKT signaling pathways. Therefore, combined targeting of RAS/MAPK and PI3K/AKT signaling pathways may be required for optimal therapeutic effect in pancreatic cancer. However, the therapeutic efficacy of combined MAPK and PI3K/AKT signaling target inhibitors is unsatisfactory in pancreatic cancer treatment, because it is often accompanied by MAPK pathway reactivation by PI3K/AKT inhibitor. Therefore, we developed an inRas37 antibody, which directly targets the intra-cellularly activated GTP-bound form of oncogenic RAS mutation and investigated its synergistic effect in the presence of the PI3K inhibitor BEZ-235 in pancreatic cancer. In this study, inRas37 remarkably increased the drug response of BEZ-235 to pancreatic cancer cells by inhibiting MAPK reactivation. Moreover, the co-treatment synergistically inhibited cell proliferation, migration, and invasion and exhibited synergistic anticancer activity by inhibiting the MAPK and PI3K pathways. The combined administration of inRas37and BEZ-235 significantly inhibited tumor growth in mouse models. Our results demonstrated that inRas37 synergistically increased the antitumor activity of BEZ-235 by inhibiting MAPK reactivation, suggesting that inRas37 and BEZ-235 co-treatment could be a potential treatment approach for pancreatic cancer patients with KRAS mutations.

Fabrication and Characterization of a Fiber-optic Radiation Sensor for Detection of Tritium (삼중수소 검출용 광섬유 방사선 센서의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Lee, Bong-Soo;Moon, Joo-Hyun;Park, Byung-Gi;Cho, Young-Ho;Kim, Sin
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.4
    • /
    • pp.201-206
    • /
    • 2009
  • In this study, we have fabricated a fiber-optic radiation sensor for detection of tritium using inorganic scintillators and optical fibers. We have tested various kinds of inorganic scintillators such as $Gd_2O_2S$ : Tb, $Y_3Al_5O_{12}$ : Ce, and CsI : Tl to select the most effective sensor tip. In addition, we have measured the scintillating lights using a photomultiplier tube as a function of distance between sensor tips to the source with the different activities of hydride tritium. The final results are compared with those which are obtained using a surface activity monitor.

Evaluating Correlation between Geometrical Relationship and Dose Difference Caused by Respiratory Motion Using Statistical Analysis

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Cho, Min-Seok;Noh, Yu-Yoon;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.203-212
    • /
    • 2016
  • Dose differences between three-dimensional (3D) and four-dimensional (4D) doses could be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The purpose of this study is to evaluate the correlation between the overlap volume histogram (OVH), which quantitatively shows the geometrical relationship between the PTV and OAR, and the dose differences. 4D computed tomography (4DCT) images were acquired for 10 liver cancer patients. Internal target volume-based treatment planning was performed. A 3D dose was calculated on a reference phase (end-exhalation). A 4D dose was accumulated using deformation vector fields between the reference and other phase images of 4DCT from deformable image registration, and dose differences between the 3D and 4D doses were calculated. An OVH between the PTV and selected OAR (duodenum) was calculated and quantified on the basis of specific overlap volumes that corresponded to 10%, 20%, 30%, 40%, and 50% of the OAR volume overlapped with the expanded PTV. Statistical analysis was performed to verify the correlation with the OVH and dose difference for the OAR. The minimum mean dose difference was 0.50 Gy from case 3, and the maximum mean dose difference was 4.96 Gy from case 2. The calculated range of the correlation coefficients between the OVH and dose difference was from -0.720 to -0.712, and the R-square range for regression analysis was from 0.506 to 0.518 (p-value <0.05). However, when the 10% overlap volume was applied in the six cases that had OVH value ${\leq}2$, the average percent mean dose differences were $34.80{\pm}12.42%$. Cases with quantified OVH values of 2 or more had mean dose differences of $29.16{\pm}11.36%$. In conclusion, no significant statistical correlation was found between the OVH and dose differences. However, it was confirmed that a higher difference between the 3D and 4D doses could occur in cases that have smaller OVH value.

A Study on the Development of Telephone for Improvement of the Hearing Impaired's Listening (난청인의 통화 청취도 향상을 위한 전화기 개발연구)

  • Lee, S.M.;Woo, B.C.;Kim, D.W.;Song, C.G.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.111-113
    • /
    • 1996
  • The impaired person and the elderly who has hearing loss have been continuously increased and these people's desire for participating society as a producer has been increased also. So they strongly request the aid device which can compensate their handicap. The healing aid telephone is one of the basic aid devices that helps the hearing impaired to communicate with other people and to acquire useful information. We design the new model of the hearing aid telephone and test it's efficiency in three fields - electrical, speech perception, user test. From the result of the test we certify that the new model is better for the hearing impaired to understand the meaning of telephone speech than the old general models. We expect that the advanced healing aid telephone can be developed by the research about speech perception characteristics of the hearing impaired in engineering and clinical side.

  • PDF

A Study on the MPEG-2 Coding Performance of 3D Endoscopic Image Sequence (3D 내시경 영상시컨스의 MPEG-2 코딩 효율에 관한 연구)

  • Song, C.G.;Lee, Y.M.;Lee, S.M.;Kim, W.K.;Lee, J.H.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.84-87
    • /
    • 1997
  • In this study, for the coding of stereoscopic video sequence, two approaches are presented based on simulcast mathod and sidefield image format. The field sequential method for stereoscopic visualization have been specified. Also, camera parameter and shooting conditions for each test sequence are studied. Coding method based on sidefield format structure revealed better performance over simulcast in PSNR.

  • PDF

Estimation of the Light Intensity by Using Bright-Chip LED Sensory System (고휘도 발광 Chip 소자를 이용한 빛의 명암도 분석)

  • Choi, Ju-Hyeon;Kim, Ji-Sun;Jung, Gu-In;Lee, Tae-Hee;Kim, A-Hee;Oh, Han-Byeol;Park, Hee-Jung;Kim, Kyung-Seop;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1290-1296
    • /
    • 2013
  • The light intensity which represents the relative amount of brightness and darkness is very important feature to discern the color hue and its relevant information. With this aim, we devise a new optical system and method to analyze the light intensity. Our suggested system including a phototransistor and white-high-brightness chip light-emitting diode intend estimate the contrast value utilizing Image Research Institute(I.R.I.) Hue & Tone samples which includes 120 color sheets arranged by the color hue and tone. As a result, we confirmed that the brightness of the color checker can be accurately estimated by a high-brightness light-emitting-diode optical system.

Cue exposure system using Virtual Reality for nicotine craving (니코틴 중독의 단서노출치료를 위한 가상환경의 제작 및 욕구 유발 실험)

  • Kim, Kwang-Uk;Cho, Won-Geun;Ku, Jeong-Hun;Kim, Hun;Kim, Byoung-Nyun;Lee, Jang-Han;Kim, In-Y.;Lee, Jong-Min;Kim, Sun-I.
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.187-192
    • /
    • 2002
  • Research has shown that many smokers experience an increase in the desire to smoke when exposed to smoking-related cues. Cue exposure treatment (CET) refers to the manualized, repeated exposure to smoking-related cues, aimed at the reducing cue reactivity by extinction. In this study, we constructed a virtual reality system for evoking a desire of nicotine, which was based on the results of a Questionnaire of Nicotine-craving. And we investigated the effectiveness of the virtual reality system as compared to classical device (pictures). As a result, we reached the conclusion that virtual reality elicits more craving symptoms than the classical devices.

  • PDF

Polymer Nanofibers for Biomedical Engineering

  • Shin, Min-Kyoon;Kim, Seon-Jeong;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.173-178
    • /
    • 2008
  • Recent advancements in the electrospinning method enable the production of ultrafine solid and continuous fibers with diameters ranging from a few nanometers to a few hundred nanometers with controlled surface and morphological features. A wide range of biopolymers can be electrospun into mats with a specific fiber arrangement and structural integrity. These features of nanofiber mats are morphologically similar to the extracellular matrix of natural tissues, which are characterized by a wide pore diameter distribution, a high porosity, effective mechanical properties, and specific biochemical properties. This has resulted in various kinds of applications for polymer nanofibers in the field of biomedicine and biotechnology. The current emphasis of research is on exploiting these properties and focusing on determining the appropriate conditions for electrospinning various biopolymers for biomedical applications, including scaffolds used in tissue engineering, wound dressing, drug delivery, artificial organs, and vascular grafts, and for protective shields in specialty fabrics. This paper reviews the research on biomedical applications of electrospun nanofibers.